Distributed photovoltaic power (PV) is the main development model of distributed generation. It is necessary to research on dispatching and operation management with large-scale distributed PV connected. This paper an...Distributed photovoltaic power (PV) is the main development model of distributed generation. It is necessary to research on dispatching and operation management with large-scale distributed PV connected. This paper analyzes development status, technical requirement and dispatching and operation management situation of distributed PV in Germany and China. Then introduce the preparation of distributed PV dispatching and operation management criterion. Through summarizing the experiences and lessons of large-scale distributed PV development in Germany, it gives advice to the development of distributed PV dispatching and operation management in China.展开更多
Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected...Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected PV systems are coincided with gray theory application conditions. A gray theory model has been applied in short-term forecast of grid-connected photovoltaic system. The verification model of the probability of small error will help to check the accuracy of the gray forecast results. The calculated result shows that the ?model accuracy has been greatly enhanced.展开更多
This paper addresses a new composite controller for a boost-buck inverter to interface the photovoltaic array with the power grid. Based on dynamically tracking the maximum power point, two novel control methodologies...This paper addresses a new composite controller for a boost-buck inverter to interface the photovoltaic array with the power grid. Based on dynamically tracking the maximum power point, two novel control methodologies are proposed to control the DC-bus and the output current for the inverter. First, a new linear cycle discrete control algorithm is introduced to realize linear control of the DC-bus voltage and synchronously get the reference current for the inner current loop with a little calculation. Then, to assure a good adaptability to noise and model uncertainty, an auto-disturbance rejection controller is chosen as the output current controller, which does not depend on precise mathematics model. Thus, output current of PV system to the grid is with low harmonic distortion and unity power factor. Simulations and experiments are performed, and the results show that the system is of excellent robustness and effective.展开更多
This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-...This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results.展开更多
文摘Distributed photovoltaic power (PV) is the main development model of distributed generation. It is necessary to research on dispatching and operation management with large-scale distributed PV connected. This paper analyzes development status, technical requirement and dispatching and operation management situation of distributed PV in Germany and China. Then introduce the preparation of distributed PV dispatching and operation management criterion. Through summarizing the experiences and lessons of large-scale distributed PV development in Germany, it gives advice to the development of distributed PV dispatching and operation management in China.
文摘Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected PV systems are coincided with gray theory application conditions. A gray theory model has been applied in short-term forecast of grid-connected photovoltaic system. The verification model of the probability of small error will help to check the accuracy of the gray forecast results. The calculated result shows that the ?model accuracy has been greatly enhanced.
基金the National Nature Science Foundation of China(60474041)National Innovation Fundation of China(05C26224301154).
文摘This paper addresses a new composite controller for a boost-buck inverter to interface the photovoltaic array with the power grid. Based on dynamically tracking the maximum power point, two novel control methodologies are proposed to control the DC-bus and the output current for the inverter. First, a new linear cycle discrete control algorithm is introduced to realize linear control of the DC-bus voltage and synchronously get the reference current for the inner current loop with a little calculation. Then, to assure a good adaptability to noise and model uncertainty, an auto-disturbance rejection controller is chosen as the output current controller, which does not depend on precise mathematics model. Thus, output current of PV system to the grid is with low harmonic distortion and unity power factor. Simulations and experiments are performed, and the results show that the system is of excellent robustness and effective.
文摘This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results.