Based on the optimal estimation method, a satellite XCO2 retrieval algorithm was constructed by combining LBLRTM with VLIDORT. One-year GOSAT/TANSO observations over four TCCON stations were tested by our algorithm, a...Based on the optimal estimation method, a satellite XCO2 retrieval algorithm was constructed by combining LBLRTM with VLIDORT. One-year GOSAT/TANSO observations over four TCCON stations were tested by our algorithm, and retrieval results were compared with GOSAT L2 B products and ground-based FTS measurements. Meanwhile, the influence of CO2 line mixing effect on retrieval was estimated, and the research showed that neglecting CO2 line mixing effect could result in approximately 0.25% XCO2 underestimation. The accuracy of XCO2 retrievals was similar to GOSAT L2 B products at cloud-free footprints with aerosol optical depth less than 0.3, and 1% accuracy of XCO2 retrievals can be reached based on the validation result with TCCON measurements.展开更多
The joint European Space Agency and Chinese Academy of Sciences Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will explore global dynamics of the magnetosphere under varying solar wind and interplane...The joint European Space Agency and Chinese Academy of Sciences Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will explore global dynamics of the magnetosphere under varying solar wind and interplanetary magnetic field conditions,and simultaneously monitor the auroral response of the Northern Hemisphere ionosphere.Combining these large-scale responses with medium and fine-scale measurements at a variety of cadences by additional ground-based and space-based instruments will enable a much greater scientific impact beyond the original goals of the SMILE mission.Here,we describe current community efforts to prepare for SMILE,and the benefits and context various experiments that have explicitly expressed support for SMILE can offer.A dedicated group of international scientists representing many different experiment types and geographical locations,the Ground-based and Additional Science Working Group,is facilitating these efforts.Preparations include constructing an online SMILE Data Fusion Facility,the discussion of particular or special modes for experiments such as coherent and incoherent scatter radar,and the consideration of particular observing strategies and spacecraft conjunctions.We anticipate growing interest and community engagement with the SMILE mission,and we welcome novel ideas and insights from the solar-terrestrial community.展开更多
A novel, simple, and sensitive Ultra Performance Liquid Chromatography (UPLC) method was developed and validated for the quantification of process-related impurities and degradants, as well as the assay of Docetaxel. ...A novel, simple, and sensitive Ultra Performance Liquid Chromatography (UPLC) method was developed and validated for the quantification of process-related impurities and degradants, as well as the assay of Docetaxel. The stability-indicating capability of the method was demonstrated through forced degradation studies and a comprehensive mass balance evaluation. Chromatographic separation was achieved using an ACQUITY UPLC BEH C18 column (100 × 2.1 mm, 1.7 µm), with gradient elution. The mobile phase A comprised a mixture of water, methanol, and acetonitrile (500:300:200, v/v/v), while mobile phase B was acetonitrile and water (800:200, v/v). The flow rate was set at 0.4 mL/min, with detection at 232 nm using a photodiode array detector. The method exhibited excellent performance, with a tailing factor of 1.10 for Docetaxel. The method was rigorously validated for precision, accuracy, linearity, LOD, LOQ, ruggedness, specificity, and robustness. Forced degradation studies confirmed the method’s suitability for stability analysis. Stability testing on the drug substance was conducted following ICH guidelines.展开更多
Cloud base height(CBH) is a crucial parameter for cloud radiative effect estimates, climate change simulations, and aviation guidance. However, due to the limited information on cloud vertical structures included in p...Cloud base height(CBH) is a crucial parameter for cloud radiative effect estimates, climate change simulations, and aviation guidance. However, due to the limited information on cloud vertical structures included in passive satellite radiometer observations, few operational satellite CBH products are currently available. This study presents a new method for retrieving CBH from satellite radiometers. The method first uses the combined measurements of satellite radiometers and ground-based cloud radars to develop a lookup table(LUT) of effective cloud water content(ECWC), representing the vertically varying cloud water content. This LUT allows for the conversion of cloud water path to cloud geometric thickness(CGT), enabling the estimation of CBH as the difference between cloud top height and CGT. Detailed comparative analysis of CBH estimates from the state-of-the-art ECWC LUT are conducted against four ground-based millimeter-wave cloud radar(MMCR) measurements, and results show that the mean bias(correlation coefficient) is0.18±1.79 km(0.73), which is lower(higher) than 0.23±2.11 km(0.67) as derived from the combined measurements of satellite radiometers and satellite radar-lidar(i.e., Cloud Sat and CALIPSO). Furthermore, the percentages of the CBH biases within 250 m increase by 5% to 10%, which varies by location. This indicates that the CBH estimates from our algorithm are more consistent with ground-based MMCR measurements. Therefore, this algorithm shows great potential for further improvement of the CBH retrievals as ground-based MMCR are being increasingly included in global surface meteorological observing networks, and the improved CBH retrievals will contribute to better cloud radiative effect estimates.展开更多
A method of analysis for the simultaneous determination of methylisothiazolinone (MI), methylchloroisothiazolinone (CMI), benzisothiazolinone (BIT) and Bronopol (BNP) in washing-up liquid was established. The method c...A method of analysis for the simultaneous determination of methylisothiazolinone (MI), methylchloroisothiazolinone (CMI), benzisothiazolinone (BIT) and Bronopol (BNP) in washing-up liquid was established. The method consisted of a gradient HPLC analysis at three different wavelengths. The four compounds could be analyzed with good precision and accuracy.展开更多
As an innovative,low-power consuming,and low-stiffness suspension approach,the diamagnetic levitation technique has attracted considerable interest because of its potential applicability in miniaturized mechanical sys...As an innovative,low-power consuming,and low-stiffness suspension approach,the diamagnetic levitation technique has attracted considerable interest because of its potential applicability in miniaturized mechanical systems.The foundation of a diamagnetic levitation system is mathematical modeling,which is essential for operating performance optimization and stability prediction.However,few studies on systematic mathematical modeling have been reported.In this study,a systematic mathematical model for a disc-shaped diamagnetically levitated rotor on a permanent magnet array is proposed.Based on the proposed model,the magnetic field distribution characteristics,diamagnetic levitation force characteristics(i.e.,levitation height and stiffness),and optimized theoretical conditions for realizing stable levitation are determined.Experiments are conducted to verify the feasibility of the proposed mathematical model.Theoretical predictions and experimental results indicate that increasing the levitation height enlarges the stable region.Moreover,with a further increase in the rotor radius,the stable regions of the rotor gradually diminish and even vanish.Thus,when the levitation height is fixed,a moderate rotor radius permits stable levitation.This study proposes a mathematical modeling method for a diamagnetic levitation system that has potential applications in miniaturized mechanical systems.展开更多
Background: The robustness is a measurement of an analytical chemical method and its ability to contain unaffected by little with deliberate variation of analytical chemical method parameters. The analytical chemical ...Background: The robustness is a measurement of an analytical chemical method and its ability to contain unaffected by little with deliberate variation of analytical chemical method parameters. The analytical chemical method variation parameters are based on pH variability of buffer solution of mobile phase, organic ratio composition changes, stationary phase (column) manufacture, brand name and lot number variation;flow rate variation and temperature variation of chromatographic system. The analytical chemical method for assay of Atropine Sulfate conducted for robustness evaluation. The typical variation considered for mobile phase organic ratio change, change of pH, change of temperature, change of flow rate, change of column etc. Purpose: The aim of this study is to develop a cost effective, short run time and robust analytical chemical method for the assay quantification of Atropine in Pharmaceutical Ophthalmic Solution. This will help to make analytical decisions quickly for research and development scientists as well as will help with quality control product release for patient consumption. This analytical method will help to meet the market demand through quick quality control test of Atropine Ophthalmic Solution and it is very easy for maintaining (GDP) good documentation practices within the shortest period of time. Method: HPLC method has been selected for developing superior method to Compendial method. Both the compendial HPLC method and developed HPLC method was run into the same HPLC system to prove the superiority of developed method. Sensitivity, precision, reproducibility, accuracy parameters were considered for superiority of method. Mobile phase ratio change, pH of buffer solution, change of stationary phase temperature, change of flow rate and change of column were taken into consideration for robustness study of the developed method. Results: The limit of quantitation (LOQ) of developed method was much low than the compendial method. The % RSD for the six sample assay of developed method was 0.4% where the % RSD of the compendial method was 1.2%. The reproducibility between two analysts was 100.4% for developed method on the contrary the compendial method was 98.4%.展开更多
AIM:To develop and evaluate the validity and reliability of a knowledge,attitude,and practice questionnaire related to vision screening(KAP-VST)among preschool teachers in Malaysia.METHODS:The questionnaire was develo...AIM:To develop and evaluate the validity and reliability of a knowledge,attitude,and practice questionnaire related to vision screening(KAP-VST)among preschool teachers in Malaysia.METHODS:The questionnaire was developed through a literature review and discussions with experts.Content and face validation were conducted by a panel of experts(n=10)and preschool teachers(n=10),respectively.A pilot study was conducted for construct validation(n=161)and test-retest reliability(n=60)of the newly developed questionnaire.RESULTS:Based on the content and face validation,71 items were generated,and 68 items were selected after exploratory factor analysis.The content validity index for items(I-CVI)score ranged from 0.8-1.0,and the content validity index for scale(S-CVI)/Ave was 0.99.Internal consistency was KR^(2)0=0.93 for knowledge,Cronbach’s alpha=0.758 for attitude,and Cronbach’s alpha=0.856 for practice.CONCLUSION:The KAP-VST is a valid and reliable instrument for assessing knowledge,attitude,and practice in relation to vision screening among preschool teachers in Malaysia.展开更多
The determination of the ethanol content in food products is of fundamental importance for HALAL certification. In this work, an analytical method for the determination of ethanol in water by headspace gas chromatogra...The determination of the ethanol content in food products is of fundamental importance for HALAL certification. In this work, an analytical method for the determination of ethanol in water by headspace gas chromatography with flame ionization detector (HS-GC-FID) has been developed and validated for the use in characterization of ethanol reference materials. The validation study was carried out in the linear calibration range 100 - 1500 mg/kg using the NIST SRM 2900, nominal 95.6%. The studied performance characteristics of the method were the limit of detection, LOD, the limit of quantification LOQ, selectivity, linearity, precision, recovery and bias. The validation results showed that the method is selective, precise, accurate and free from any significant bias. The LOD and LOQ were 1.27 and 3.86 mg/kg respectively and the estimated expanded uncertainty was 2% indicating that the method is fit for the purpose of certification of ethanol in water reference materials.展开更多
In order to provide relay communication supports for future Chinese lunar exploration program,Queqiao-2 relay communication satellite was developed.Queqiao-2 can perform scientific observations with three kinds of sci...In order to provide relay communication supports for future Chinese lunar exploration program,Queqiao-2 relay communication satellite was developed.Queqiao-2 can perform scientific observations with three kinds of scientific instruments on board.The system design of Queqiao-2,including mission orbit and transfer orbit design,configuration and layout design,housekeeping and information flow design,power supply and distribution design,GNC and propulsion system design,communication links design,etc.,was accomplished through comprehensive tradeoff and evaluation on technical maturity,availability,schedule,cost,and so on.With a view to reducing development risk,both the platform and relay communication payloads were developed based on significant heritage from previous Queqiao relay satellite and other relevant spacecraft.Queqiao-2 features flexible system architecture to support multiple frequencies,modulations,data rates and software reconfigurations to meet new user requirements.Subsequent to a successful launch on March 20,2024,by means of 5 orbit maneuvers,Queqiao-2 was inserted into a highly elliptical frozen mission orbit around the moon with a 24h period on schedule.Following on-orbit tests and calibrations,Queqiao-2 has possessed the capacity to provide reliable relay communication services to multiple lunar exploration missions,as well as the capacity to perform scientific observations.Under the support of Queqiao-2,Chang′e-6 achieved its ambitious mission goal to collect and return samples from the moon′s mysterious far side.In the meanwhile,Queqiao-2 has also paved the way for the following Chinese lunar exploration missions including Chang′e-7 and Chang′e-8.The design life time of Queqiao-2 is more than 8 years.Benefit from flexibility and extensibility of relay communication system design,it is convenient to provide relay communication services for future lunar exploration missions of both China and other countries.In addition,innovative scientific observations would be performed during the period that no relay communication task is arranged.The system design of Queqiao-2 reflects the development philosophy of technical innovations and inheritance integration.Based on highly flexible and extensible system architecture,multiple and concurrent relay communication mission requirements can be met.It can provide strong supports for future lunar exploration missions.Successful launching,orbit entering and on-orbit tests of Queqiao-2 verified the correct design principle and versatility.By means of Queqiao-2,more innovative scientific outcomes are anticipated and lunar exploration activities can be facilitated.展开更多
The new method proposed is based on the formation of hydralazine-Bromophenol blue ion pair simply and without further extraction or heating. The ion pair was prepared in the presence of pH 3 citrate buffer forming a y...The new method proposed is based on the formation of hydralazine-Bromophenol blue ion pair simply and without further extraction or heating. The ion pair was prepared in the presence of pH 3 citrate buffer forming a yellow-colored chromogen. A new maximum UV-visible band formed at 416 nm. The color was stable for more than 10 hours and obeyed Beer’s Law over the concentration range of 10 - 50 µg/mL. The calculated molar absorptivity and Sandell’s sensitivity were 1.01 × 104 L∙mol−1∙cm−1 and 0.0514 µg/mL, respectively. The elements of method validation stipulated by The International Conference on Harmonization [Q2 (R1)] were applied for hydralazine hydrochloride assay in pure and pharmaceutical tablet formulation. The average recoveries of the pure solution and the pharmaceutical formulation were 98.94% and 99.50%, respectively. The results were statistically compared by F-test, which indicates that the method can be precise and repeatable for both pure and pharmaceutical solutions. The method was found to be accurate, reproducible, and cost-effective, and validated for the assay of hydralazine in terms of the routine quality control.展开更多
Background:Coping self-efficacy can help individuals mitigate the adverse emotional impacts of stress,anxiety,and other negative emotions,and it also influences individuals’academic performance,including school adjus...Background:Coping self-efficacy can help individuals mitigate the adverse emotional impacts of stress,anxiety,and other negative emotions,and it also influences individuals’academic performance,including school adjustment and academic burnout.It is an important factor affecting the mental health of adolescents.However,there is no measurement tool specifically designed for adolescent populations in China.Therefore,the purpose of this study is to assess the applicability of the Coping Self-Efficacy Scale(CSES)among Chinese adolescents.Methods:In September 2023,this study collected data through online questionnaires and ultimately conducted item analysis,exploratory factor analysis,confirmatory factor analysis(CFA),measurement invariance analysis,reliability analysis,and criterion-related validity analysis on a sample of 1157 adolescents.Results:The results of item analysis showed that the items of CSES were significantly different between the high and low groups.Further factor analysis results showed the existence of a factor solution that explained 59.09%of the total variation,with factor loadings ranging from 0.52–0.78.CFA supported the three-factor model of Chinese adolescent version of the CSES(CFI=0.923,TLI=0.914,IFI=0.923,RMSEA=0.068).Measurement invariance analysis indicates that the scale satisfies gender measurement invariance(ΔCFI=-0.002,-0.001>-0.01,ΔRMSEA=-0.001,0<0.02,ΔSRMR=0.005,0.007<0.01).The Chinese adolescent version of the CSES was positively correlated with the Social Support Appraisal Scale(SS-A)and the Life Orientation Test-Revised(LOT-R,r=0.670,0.673,both p<0.01),and negatively correlated with the Chinese Perceived Stress Scale(CPSS),the State-Trait Anxiety Inventory(STAI)and the Adolescent Student Burnout Inventory(ASBI,r=-0.694,-0.233,-0.680,both p<0.01).The Cronbach’sα,McDonald’sω,split-half reliability and test-retest reliability of the Chinese adolescent version of the CSES were 0.953,0.955,0.933 and 0.894,respectively.Conclusion:The results indicate that the three-factor model of the Chinese adolescent version of the CSES is acceptable and demonstrates high reliability and validity,establishing it as a precise tool for measuring and assessing coping self-efficacy among Chinese adolescents.展开更多
To accelerate the practicality of electromagnetic railguns,it is necessary to use a combination of threedimensional numerical simulation and experiments to study the mechanism of bore damage.In this paper,a three-dime...To accelerate the practicality of electromagnetic railguns,it is necessary to use a combination of threedimensional numerical simulation and experiments to study the mechanism of bore damage.In this paper,a three-dimensional numerical model of the augmented railgun with four parallel unconventional rails is introduced to simulate the internal ballistic process and realize the multi-physics field coupling calculation of the rail gun,and a test experiment of a medium-caliber electromagnetic launcher powered by pulse formation network(PFN)is carried out.Various test methods such as spectrometer,fiber grating and high-speed camera are used to test several parameters such as muzzle initial velocity,transient magnetic field strength and stress-strain of rail.Combining the simulation results and experimental data,the damage condition of the contact surface is analyzed.展开更多
Gastric cancer(GC)remains a formidable global health concern with significant morbidity and mortality rates,despite the fact that numerous advances have been made to improve conventional therapies.Xiaojianzhong decoct...Gastric cancer(GC)remains a formidable global health concern with significant morbidity and mortality rates,despite the fact that numerous advances have been made to improve conventional therapies.Xiaojianzhong decoction(XJZ),a traditional Chinese medicine,has garnered academic attention as a multicomponent,multitarget approach to managing GC.The present editorial explores the potential of XJZ in the treatment of GC through a comprehensive analysis of network pharmacology and experimental validation.Network pharmacology was used to identify key molecular targets of XJZ,including interleukin 6,prostaglandin-endoperoxide synthase 2,and matrix metalloproteinase 9,and in vitro experiments were used to confirm the efficacy of XJZ in inhibiting cell proliferation,inducing apoptosis,and modulating gene expression associated with GC progression.This editorial highlights XJZ as a promising therapeutic strategy for GC and indicates a need for further clinical exploration and validation of its efficacy.展开更多
A tracking stability control problem for the vertical electric stabilization system of moving tank based on adaptive robust servo control is addressed.This paper mainly focuses on two types of possibly fast timevaryin...A tracking stability control problem for the vertical electric stabilization system of moving tank based on adaptive robust servo control is addressed.This paper mainly focuses on two types of possibly fast timevarying but bounded uncertainty within the vertical electric stabilization system:model parameter uncertainty and uncertain nonlinearity.First,the vertical electric stabilization system is constructed as an uncertain nonlinear dynamic system that can reflect the practical mechanics transfer process of the system.Second,the dynamical equation in the form of state space is established by designing the angular tracking error.Third,the comprehensive parameter of system uncertainty is designed to estimate the most conservative effects of uncertainty.Finally,an adaptive robust servo control which can effectively handle the combined effects of complex nonlinearity and uncertainty is proposed.The feasibility of the proposed control strategy under the practical physical condition is validated through the tests on the experimental platform.This paper pioneers the introduction of the internal nonlinearity and uncertainty of the vertical electric stabilization system into the settlement of the tracking stability control problem,and validates the advanced servo control strategy through experiment for the first time.展开更多
BACKGROUND Endometrial cancer(EC)is a common gynecological malignancy that typically requires prompt surgical intervention;however,the advantage of surgical management is limited by the high postoperative recurrence r...BACKGROUND Endometrial cancer(EC)is a common gynecological malignancy that typically requires prompt surgical intervention;however,the advantage of surgical management is limited by the high postoperative recurrence rates and adverse outcomes.Previous studies have highlighted the prognostic potential of circulating tumor DNA(ctDNA)monitoring for minimal residual disease in patients with EC.AIM To develop and validate an optimized ctDNA-based model for predicting shortterm postoperative EC recurrence.METHODS We retrospectively analyzed 294 EC patients treated surgically from 2015-2019 to devise a short-term recurrence prediction model,which was validated on 143 EC patients operated between 2020 and 2021.Prognostic factors were identified using univariate Cox,Lasso,and multivariate Cox regressions.A nomogram was created to predict the 1,1.5,and 2-year recurrence-free survival(RFS).Model performance was assessed via receiver operating characteristic(ROC),calibration,and decision curve analyses(DCA),leading to a recurrence risk stratification system.RESULTS Based on the regression analysis and the nomogram created,patients with postoperative ctDNA-negativity,postoperative carcinoembryonic antigen 125(CA125)levels of<19 U/mL,and grade G1 tumors had improved RFS after surgery.The nomogram’s efficacy for recurrence prediction was confirmed through ROC analysis,calibration curves,and DCA methods,highlighting its high accuracy and clinical utility.Furthermore,using the nomogram,the patients were successfully classified into three risk subgroups.CONCLUSION The nomogram accurately predicted RFS after EC surgery at 1,1.5,and 2 years.This model will help clinicians personalize treatments,stratify risks,and enhance clinical outcomes for patients with EC.展开更多
The pharmaceutical industry’s increasing adoption of cloud-based technologies has introduced new challenges in computerized systems validation (CSV). This paper explores the evolving landscape of cloud validation in ...The pharmaceutical industry’s increasing adoption of cloud-based technologies has introduced new challenges in computerized systems validation (CSV). This paper explores the evolving landscape of cloud validation in pharmaceutical manufacturing, focusing on ensuring data integrity and regulatory compliance in the digital era. We examine the unique characteristics of cloud-based systems and their implications for traditional validation approaches. A comprehensive review of current regulatory frameworks, including FDA and EMA guidelines, provides context for discussing cloud-specific validation challenges. The paper introduces a risk-based approach to cloud CSV, detailing methodologies for assessing and mitigating risks associated with cloud adoption in pharmaceutical environments. Key considerations for maintaining data integrity in cloud systems are analyzed, particularly when applying ALCOA+ principles in distributed computing environments. The article presents strategies for adapting traditional Installation Qualification (IQ), Operational Qualification (OQ), and Performance Qualification (PQ) models to cloud-based systems, highlighting the importance of continuous validation in dynamic cloud environments. The paper also explores emerging trends, including integrating artificial intelligence and edge computing in pharmaceutical manufacturing and their implications for future validation strategies. This research contributes to the evolving body of knowledge on cloud validation in pharmaceuticals by proposing a framework that balances regulatory compliance with the agility offered by cloud technologies. The findings suggest that while cloud adoption presents unique challenges, a well-structured, risk-based approach to validation can ensure the integrity and compliance of cloud-based systems in pharmaceutical manufacturing.展开更多
In this study, the simple DPPH UV-spectrophotometric analytical procedures were optimized and validated for the estimation of antioxidant properties in aerated, semi-aerated and non-aerated tea products as per the AOA...In this study, the simple DPPH UV-spectrophotometric analytical procedures were optimized and validated for the estimation of antioxidant properties in aerated, semi-aerated and non-aerated tea products as per the AOAC guidelines. The method was found to be simple, rapid, accurate and economical in estimating antioxidant properties in the different tea products. A (0.0100 ± 0.0001) g well ground tea sample was extracted directly in 80% v/v methanol in distilled water. The precision of the method had an RSD% of 1.695 with a linear relation equation of Y = 200.7X + 5.25 (r2 = 0.997). The method proved to be a reliable and effective tool in analysis of anti-oxidant properties in varied tea cultivars and their processed products.展开更多
To compare finite element analysis(FEA)predictions and stereovision digital image correlation(StereoDIC)strain measurements at the same spatial positions throughout a region of interest,a field comparison procedure is...To compare finite element analysis(FEA)predictions and stereovision digital image correlation(StereoDIC)strain measurements at the same spatial positions throughout a region of interest,a field comparison procedure is developed.The procedure includes(a)conversion of the finite element data into a triangular mesh,(b)selection of a common coordinate system,(c)determination of the rigid body transformation to place both measurements and FEA data in the same system and(d)interpolation of the FEA nodal information to the same spatial locations as the StereoDIC measurements using barycentric coordinates.For an aluminum Al-6061 double edge notched tensile specimen,FEA results are obtained using both the von Mises isotropic yield criterion and Hill’s quadratic anisotropic yield criterion,with the unknown Hill model parameters determined using full-field specimen strain measurements for the nominally plane stress specimen.Using Hill’s quadratic anisotropic yield criterion,the point-by-point comparison of experimentally based full-field strains and stresses to finite element predictions are shown to be in excellent agreement,confirming the effectiveness of the field comparison process.展开更多
Objective:Validation is an important aspect of an instrument,and it ensures the confidence of researchers to employ the instrument in their studies.This study was conducted to develop and validate an instrument to ass...Objective:Validation is an important aspect of an instrument,and it ensures the confidence of researchers to employ the instrument in their studies.This study was conducted to develop and validate an instrument to assess knowledge,attitudes,and practices(KAP) on digital health among nurses since digital health capacity is a major concern in health care that needs to be assessed.Methods:We conducted a methodological study to assess the content validity and reliability of the instrument.First,items were generated through a comprehensive literature review and by obtaining an expert opinion.Second,content and face validity were assessed by a panel of 7 experts.Both the item-level content validity index(I-CVI) and the scale-level content validity index(S-CVI) were established.Moreover,test–retest reliability and internal consistency of the instrument were assessed.Data were analyzed using SPSS version 25.Results:The initial pool consisted of 60 items and after obtaining content,face,and construct validity,51 items remained.Items with an I-CVI <0.78 were considered relevant.The S-CVI for relevancy,clarity,ambiguity,and simplicity were 0.93,0.91,0.94,and 0.92,respectively.Five subcomponents were constructed in each knowledge and attitudes domain,and the test–retest reliability test revealed that the instrument has good reliability,showing correlation coefficient values for the KAP domains and the total questionnaire of 0.76,0.98,0.99,and 0.99,respectively.The independent Cronbach's α for all items was 0.76,indicating good internal consistency.Conclusions:The present study established the acceptable validity and ensured the good reliability and internal consistency of the instrument,which can serve as an assessment tool of KAP on digital health among healthcare professionals.展开更多
基金supported by the National High Technology Research and Development Program of China(Grant No.2011AA12A104-3)the Strategic Priority Research Program(Grant No.XDA05100300)+4 种基金the European Commission’s Seventh Framework Program"PANDA"(Grant No.FP7-SPACE-2013-1)the Public Industry-specific Fund for Meteorology(Grant No.GYHY201106045)the 4th and 5th GOSAT/TANSO Joint Research Project,National Basic Research Program of China(Grant No.2013CB955801)National Natural Science Foundation of China(Grant No.41175030)China Earth Observation Project(Grant No.E310/1112)
文摘Based on the optimal estimation method, a satellite XCO2 retrieval algorithm was constructed by combining LBLRTM with VLIDORT. One-year GOSAT/TANSO observations over four TCCON stations were tested by our algorithm, and retrieval results were compared with GOSAT L2 B products and ground-based FTS measurements. Meanwhile, the influence of CO2 line mixing effect on retrieval was estimated, and the research showed that neglecting CO2 line mixing effect could result in approximately 0.25% XCO2 underestimation. The accuracy of XCO2 retrievals was similar to GOSAT L2 B products at cloud-free footprints with aerosol optical depth less than 0.3, and 1% accuracy of XCO2 retrievals can be reached based on the validation result with TCCON measurements.
基金supported by Royal Society grant DHFR1211068funded by UKSA+14 种基金STFCSTFC grant ST/M001083/1funded by STFC grant ST/W00089X/1supported by NERC grant NE/W003309/1(E3d)funded by NERC grant NE/V000748/1support from NERC grants NE/V015133/1,NE/R016038/1(BAS magnetometers),and grants NE/R01700X/1 and NE/R015848/1(EISCAT)supported by NERC grant NE/T000937/1NSFC grants 42174208 and 41821003supported by the Research Council of Norway grant 223252PRODEX arrangement 4000123238 from the European Space Agencysupport of the AUTUMN East-West magnetometer network by the Canadian Space Agencysupported by NASA’s Heliophysics U.S.Participating Investigator Programsupport from grant NSF AGS 2027210supported by grant Dnr:2020-00106 from the Swedish National Space Agencysupported by the German Research Foundation(DFG)under number KR 4375/2-1 within SPP"Dynamic Earth"。
文摘The joint European Space Agency and Chinese Academy of Sciences Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)mission will explore global dynamics of the magnetosphere under varying solar wind and interplanetary magnetic field conditions,and simultaneously monitor the auroral response of the Northern Hemisphere ionosphere.Combining these large-scale responses with medium and fine-scale measurements at a variety of cadences by additional ground-based and space-based instruments will enable a much greater scientific impact beyond the original goals of the SMILE mission.Here,we describe current community efforts to prepare for SMILE,and the benefits and context various experiments that have explicitly expressed support for SMILE can offer.A dedicated group of international scientists representing many different experiment types and geographical locations,the Ground-based and Additional Science Working Group,is facilitating these efforts.Preparations include constructing an online SMILE Data Fusion Facility,the discussion of particular or special modes for experiments such as coherent and incoherent scatter radar,and the consideration of particular observing strategies and spacecraft conjunctions.We anticipate growing interest and community engagement with the SMILE mission,and we welcome novel ideas and insights from the solar-terrestrial community.
文摘A novel, simple, and sensitive Ultra Performance Liquid Chromatography (UPLC) method was developed and validated for the quantification of process-related impurities and degradants, as well as the assay of Docetaxel. The stability-indicating capability of the method was demonstrated through forced degradation studies and a comprehensive mass balance evaluation. Chromatographic separation was achieved using an ACQUITY UPLC BEH C18 column (100 × 2.1 mm, 1.7 µm), with gradient elution. The mobile phase A comprised a mixture of water, methanol, and acetonitrile (500:300:200, v/v/v), while mobile phase B was acetonitrile and water (800:200, v/v). The flow rate was set at 0.4 mL/min, with detection at 232 nm using a photodiode array detector. The method exhibited excellent performance, with a tailing factor of 1.10 for Docetaxel. The method was rigorously validated for precision, accuracy, linearity, LOD, LOQ, ruggedness, specificity, and robustness. Forced degradation studies confirmed the method’s suitability for stability analysis. Stability testing on the drug substance was conducted following ICH guidelines.
基金funded by the National Natural Science Foundation of China (Grant Nos. 42305150 and 42325501)the China Postdoctoral Science Foundation (Grant No. 2023M741774)。
文摘Cloud base height(CBH) is a crucial parameter for cloud radiative effect estimates, climate change simulations, and aviation guidance. However, due to the limited information on cloud vertical structures included in passive satellite radiometer observations, few operational satellite CBH products are currently available. This study presents a new method for retrieving CBH from satellite radiometers. The method first uses the combined measurements of satellite radiometers and ground-based cloud radars to develop a lookup table(LUT) of effective cloud water content(ECWC), representing the vertically varying cloud water content. This LUT allows for the conversion of cloud water path to cloud geometric thickness(CGT), enabling the estimation of CBH as the difference between cloud top height and CGT. Detailed comparative analysis of CBH estimates from the state-of-the-art ECWC LUT are conducted against four ground-based millimeter-wave cloud radar(MMCR) measurements, and results show that the mean bias(correlation coefficient) is0.18±1.79 km(0.73), which is lower(higher) than 0.23±2.11 km(0.67) as derived from the combined measurements of satellite radiometers and satellite radar-lidar(i.e., Cloud Sat and CALIPSO). Furthermore, the percentages of the CBH biases within 250 m increase by 5% to 10%, which varies by location. This indicates that the CBH estimates from our algorithm are more consistent with ground-based MMCR measurements. Therefore, this algorithm shows great potential for further improvement of the CBH retrievals as ground-based MMCR are being increasingly included in global surface meteorological observing networks, and the improved CBH retrievals will contribute to better cloud radiative effect estimates.
文摘A method of analysis for the simultaneous determination of methylisothiazolinone (MI), methylchloroisothiazolinone (CMI), benzisothiazolinone (BIT) and Bronopol (BNP) in washing-up liquid was established. The method consisted of a gradient HPLC analysis at three different wavelengths. The four compounds could be analyzed with good precision and accuracy.
基金Supported by National Natural Science Foundation of China (Grant No.52275537)Nanjing Major Scientific and Technological Project of China (Grant No.202209011)。
文摘As an innovative,low-power consuming,and low-stiffness suspension approach,the diamagnetic levitation technique has attracted considerable interest because of its potential applicability in miniaturized mechanical systems.The foundation of a diamagnetic levitation system is mathematical modeling,which is essential for operating performance optimization and stability prediction.However,few studies on systematic mathematical modeling have been reported.In this study,a systematic mathematical model for a disc-shaped diamagnetically levitated rotor on a permanent magnet array is proposed.Based on the proposed model,the magnetic field distribution characteristics,diamagnetic levitation force characteristics(i.e.,levitation height and stiffness),and optimized theoretical conditions for realizing stable levitation are determined.Experiments are conducted to verify the feasibility of the proposed mathematical model.Theoretical predictions and experimental results indicate that increasing the levitation height enlarges the stable region.Moreover,with a further increase in the rotor radius,the stable regions of the rotor gradually diminish and even vanish.Thus,when the levitation height is fixed,a moderate rotor radius permits stable levitation.This study proposes a mathematical modeling method for a diamagnetic levitation system that has potential applications in miniaturized mechanical systems.
文摘Background: The robustness is a measurement of an analytical chemical method and its ability to contain unaffected by little with deliberate variation of analytical chemical method parameters. The analytical chemical method variation parameters are based on pH variability of buffer solution of mobile phase, organic ratio composition changes, stationary phase (column) manufacture, brand name and lot number variation;flow rate variation and temperature variation of chromatographic system. The analytical chemical method for assay of Atropine Sulfate conducted for robustness evaluation. The typical variation considered for mobile phase organic ratio change, change of pH, change of temperature, change of flow rate, change of column etc. Purpose: The aim of this study is to develop a cost effective, short run time and robust analytical chemical method for the assay quantification of Atropine in Pharmaceutical Ophthalmic Solution. This will help to make analytical decisions quickly for research and development scientists as well as will help with quality control product release for patient consumption. This analytical method will help to meet the market demand through quick quality control test of Atropine Ophthalmic Solution and it is very easy for maintaining (GDP) good documentation practices within the shortest period of time. Method: HPLC method has been selected for developing superior method to Compendial method. Both the compendial HPLC method and developed HPLC method was run into the same HPLC system to prove the superiority of developed method. Sensitivity, precision, reproducibility, accuracy parameters were considered for superiority of method. Mobile phase ratio change, pH of buffer solution, change of stationary phase temperature, change of flow rate and change of column were taken into consideration for robustness study of the developed method. Results: The limit of quantitation (LOQ) of developed method was much low than the compendial method. The % RSD for the six sample assay of developed method was 0.4% where the % RSD of the compendial method was 1.2%. The reproducibility between two analysts was 100.4% for developed method on the contrary the compendial method was 98.4%.
文摘AIM:To develop and evaluate the validity and reliability of a knowledge,attitude,and practice questionnaire related to vision screening(KAP-VST)among preschool teachers in Malaysia.METHODS:The questionnaire was developed through a literature review and discussions with experts.Content and face validation were conducted by a panel of experts(n=10)and preschool teachers(n=10),respectively.A pilot study was conducted for construct validation(n=161)and test-retest reliability(n=60)of the newly developed questionnaire.RESULTS:Based on the content and face validation,71 items were generated,and 68 items were selected after exploratory factor analysis.The content validity index for items(I-CVI)score ranged from 0.8-1.0,and the content validity index for scale(S-CVI)/Ave was 0.99.Internal consistency was KR^(2)0=0.93 for knowledge,Cronbach’s alpha=0.758 for attitude,and Cronbach’s alpha=0.856 for practice.CONCLUSION:The KAP-VST is a valid and reliable instrument for assessing knowledge,attitude,and practice in relation to vision screening among preschool teachers in Malaysia.
文摘The determination of the ethanol content in food products is of fundamental importance for HALAL certification. In this work, an analytical method for the determination of ethanol in water by headspace gas chromatography with flame ionization detector (HS-GC-FID) has been developed and validated for the use in characterization of ethanol reference materials. The validation study was carried out in the linear calibration range 100 - 1500 mg/kg using the NIST SRM 2900, nominal 95.6%. The studied performance characteristics of the method were the limit of detection, LOD, the limit of quantification LOQ, selectivity, linearity, precision, recovery and bias. The validation results showed that the method is selective, precise, accurate and free from any significant bias. The LOD and LOQ were 1.27 and 3.86 mg/kg respectively and the estimated expanded uncertainty was 2% indicating that the method is fit for the purpose of certification of ethanol in water reference materials.
文摘In order to provide relay communication supports for future Chinese lunar exploration program,Queqiao-2 relay communication satellite was developed.Queqiao-2 can perform scientific observations with three kinds of scientific instruments on board.The system design of Queqiao-2,including mission orbit and transfer orbit design,configuration and layout design,housekeeping and information flow design,power supply and distribution design,GNC and propulsion system design,communication links design,etc.,was accomplished through comprehensive tradeoff and evaluation on technical maturity,availability,schedule,cost,and so on.With a view to reducing development risk,both the platform and relay communication payloads were developed based on significant heritage from previous Queqiao relay satellite and other relevant spacecraft.Queqiao-2 features flexible system architecture to support multiple frequencies,modulations,data rates and software reconfigurations to meet new user requirements.Subsequent to a successful launch on March 20,2024,by means of 5 orbit maneuvers,Queqiao-2 was inserted into a highly elliptical frozen mission orbit around the moon with a 24h period on schedule.Following on-orbit tests and calibrations,Queqiao-2 has possessed the capacity to provide reliable relay communication services to multiple lunar exploration missions,as well as the capacity to perform scientific observations.Under the support of Queqiao-2,Chang′e-6 achieved its ambitious mission goal to collect and return samples from the moon′s mysterious far side.In the meanwhile,Queqiao-2 has also paved the way for the following Chinese lunar exploration missions including Chang′e-7 and Chang′e-8.The design life time of Queqiao-2 is more than 8 years.Benefit from flexibility and extensibility of relay communication system design,it is convenient to provide relay communication services for future lunar exploration missions of both China and other countries.In addition,innovative scientific observations would be performed during the period that no relay communication task is arranged.The system design of Queqiao-2 reflects the development philosophy of technical innovations and inheritance integration.Based on highly flexible and extensible system architecture,multiple and concurrent relay communication mission requirements can be met.It can provide strong supports for future lunar exploration missions.Successful launching,orbit entering and on-orbit tests of Queqiao-2 verified the correct design principle and versatility.By means of Queqiao-2,more innovative scientific outcomes are anticipated and lunar exploration activities can be facilitated.
文摘The new method proposed is based on the formation of hydralazine-Bromophenol blue ion pair simply and without further extraction or heating. The ion pair was prepared in the presence of pH 3 citrate buffer forming a yellow-colored chromogen. A new maximum UV-visible band formed at 416 nm. The color was stable for more than 10 hours and obeyed Beer’s Law over the concentration range of 10 - 50 µg/mL. The calculated molar absorptivity and Sandell’s sensitivity were 1.01 × 104 L∙mol−1∙cm−1 and 0.0514 µg/mL, respectively. The elements of method validation stipulated by The International Conference on Harmonization [Q2 (R1)] were applied for hydralazine hydrochloride assay in pure and pharmaceutical tablet formulation. The average recoveries of the pure solution and the pharmaceutical formulation were 98.94% and 99.50%, respectively. The results were statistically compared by F-test, which indicates that the method can be precise and repeatable for both pure and pharmaceutical solutions. The method was found to be accurate, reproducible, and cost-effective, and validated for the assay of hydralazine in terms of the routine quality control.
基金supported by the National Natural Science Foundation of China,Grant No.31800913(to Kaiyun Li),Grant No.32100856(to Fanlu Jia)Youth Innovation Team of Shandong Provincial Higher Education Institutions,Grant No.2022RW019(to Fanlu Jia).
文摘Background:Coping self-efficacy can help individuals mitigate the adverse emotional impacts of stress,anxiety,and other negative emotions,and it also influences individuals’academic performance,including school adjustment and academic burnout.It is an important factor affecting the mental health of adolescents.However,there is no measurement tool specifically designed for adolescent populations in China.Therefore,the purpose of this study is to assess the applicability of the Coping Self-Efficacy Scale(CSES)among Chinese adolescents.Methods:In September 2023,this study collected data through online questionnaires and ultimately conducted item analysis,exploratory factor analysis,confirmatory factor analysis(CFA),measurement invariance analysis,reliability analysis,and criterion-related validity analysis on a sample of 1157 adolescents.Results:The results of item analysis showed that the items of CSES were significantly different between the high and low groups.Further factor analysis results showed the existence of a factor solution that explained 59.09%of the total variation,with factor loadings ranging from 0.52–0.78.CFA supported the three-factor model of Chinese adolescent version of the CSES(CFI=0.923,TLI=0.914,IFI=0.923,RMSEA=0.068).Measurement invariance analysis indicates that the scale satisfies gender measurement invariance(ΔCFI=-0.002,-0.001>-0.01,ΔRMSEA=-0.001,0<0.02,ΔSRMR=0.005,0.007<0.01).The Chinese adolescent version of the CSES was positively correlated with the Social Support Appraisal Scale(SS-A)and the Life Orientation Test-Revised(LOT-R,r=0.670,0.673,both p<0.01),and negatively correlated with the Chinese Perceived Stress Scale(CPSS),the State-Trait Anxiety Inventory(STAI)and the Adolescent Student Burnout Inventory(ASBI,r=-0.694,-0.233,-0.680,both p<0.01).The Cronbach’sα,McDonald’sω,split-half reliability and test-retest reliability of the Chinese adolescent version of the CSES were 0.953,0.955,0.933 and 0.894,respectively.Conclusion:The results indicate that the three-factor model of the Chinese adolescent version of the CSES is acceptable and demonstrates high reliability and validity,establishing it as a precise tool for measuring and assessing coping self-efficacy among Chinese adolescents.
文摘To accelerate the practicality of electromagnetic railguns,it is necessary to use a combination of threedimensional numerical simulation and experiments to study the mechanism of bore damage.In this paper,a three-dimensional numerical model of the augmented railgun with four parallel unconventional rails is introduced to simulate the internal ballistic process and realize the multi-physics field coupling calculation of the rail gun,and a test experiment of a medium-caliber electromagnetic launcher powered by pulse formation network(PFN)is carried out.Various test methods such as spectrometer,fiber grating and high-speed camera are used to test several parameters such as muzzle initial velocity,transient magnetic field strength and stress-strain of rail.Combining the simulation results and experimental data,the damage condition of the contact surface is analyzed.
文摘Gastric cancer(GC)remains a formidable global health concern with significant morbidity and mortality rates,despite the fact that numerous advances have been made to improve conventional therapies.Xiaojianzhong decoction(XJZ),a traditional Chinese medicine,has garnered academic attention as a multicomponent,multitarget approach to managing GC.The present editorial explores the potential of XJZ in the treatment of GC through a comprehensive analysis of network pharmacology and experimental validation.Network pharmacology was used to identify key molecular targets of XJZ,including interleukin 6,prostaglandin-endoperoxide synthase 2,and matrix metalloproteinase 9,and in vitro experiments were used to confirm the efficacy of XJZ in inhibiting cell proliferation,inducing apoptosis,and modulating gene expression associated with GC progression.This editorial highlights XJZ as a promising therapeutic strategy for GC and indicates a need for further clinical exploration and validation of its efficacy.
基金supported in part by the Nation Natural Science Foundation of China under Grant No.52175099China Postdoctoral Science Foundation under Grant No.2020M671494Jiangsu Planned Projects for Postdoctoral Research Funds under Grant No.2020Z179。
文摘A tracking stability control problem for the vertical electric stabilization system of moving tank based on adaptive robust servo control is addressed.This paper mainly focuses on two types of possibly fast timevarying but bounded uncertainty within the vertical electric stabilization system:model parameter uncertainty and uncertain nonlinearity.First,the vertical electric stabilization system is constructed as an uncertain nonlinear dynamic system that can reflect the practical mechanics transfer process of the system.Second,the dynamical equation in the form of state space is established by designing the angular tracking error.Third,the comprehensive parameter of system uncertainty is designed to estimate the most conservative effects of uncertainty.Finally,an adaptive robust servo control which can effectively handle the combined effects of complex nonlinearity and uncertainty is proposed.The feasibility of the proposed control strategy under the practical physical condition is validated through the tests on the experimental platform.This paper pioneers the introduction of the internal nonlinearity and uncertainty of the vertical electric stabilization system into the settlement of the tracking stability control problem,and validates the advanced servo control strategy through experiment for the first time.
文摘BACKGROUND Endometrial cancer(EC)is a common gynecological malignancy that typically requires prompt surgical intervention;however,the advantage of surgical management is limited by the high postoperative recurrence rates and adverse outcomes.Previous studies have highlighted the prognostic potential of circulating tumor DNA(ctDNA)monitoring for minimal residual disease in patients with EC.AIM To develop and validate an optimized ctDNA-based model for predicting shortterm postoperative EC recurrence.METHODS We retrospectively analyzed 294 EC patients treated surgically from 2015-2019 to devise a short-term recurrence prediction model,which was validated on 143 EC patients operated between 2020 and 2021.Prognostic factors were identified using univariate Cox,Lasso,and multivariate Cox regressions.A nomogram was created to predict the 1,1.5,and 2-year recurrence-free survival(RFS).Model performance was assessed via receiver operating characteristic(ROC),calibration,and decision curve analyses(DCA),leading to a recurrence risk stratification system.RESULTS Based on the regression analysis and the nomogram created,patients with postoperative ctDNA-negativity,postoperative carcinoembryonic antigen 125(CA125)levels of<19 U/mL,and grade G1 tumors had improved RFS after surgery.The nomogram’s efficacy for recurrence prediction was confirmed through ROC analysis,calibration curves,and DCA methods,highlighting its high accuracy and clinical utility.Furthermore,using the nomogram,the patients were successfully classified into three risk subgroups.CONCLUSION The nomogram accurately predicted RFS after EC surgery at 1,1.5,and 2 years.This model will help clinicians personalize treatments,stratify risks,and enhance clinical outcomes for patients with EC.
文摘The pharmaceutical industry’s increasing adoption of cloud-based technologies has introduced new challenges in computerized systems validation (CSV). This paper explores the evolving landscape of cloud validation in pharmaceutical manufacturing, focusing on ensuring data integrity and regulatory compliance in the digital era. We examine the unique characteristics of cloud-based systems and their implications for traditional validation approaches. A comprehensive review of current regulatory frameworks, including FDA and EMA guidelines, provides context for discussing cloud-specific validation challenges. The paper introduces a risk-based approach to cloud CSV, detailing methodologies for assessing and mitigating risks associated with cloud adoption in pharmaceutical environments. Key considerations for maintaining data integrity in cloud systems are analyzed, particularly when applying ALCOA+ principles in distributed computing environments. The article presents strategies for adapting traditional Installation Qualification (IQ), Operational Qualification (OQ), and Performance Qualification (PQ) models to cloud-based systems, highlighting the importance of continuous validation in dynamic cloud environments. The paper also explores emerging trends, including integrating artificial intelligence and edge computing in pharmaceutical manufacturing and their implications for future validation strategies. This research contributes to the evolving body of knowledge on cloud validation in pharmaceuticals by proposing a framework that balances regulatory compliance with the agility offered by cloud technologies. The findings suggest that while cloud adoption presents unique challenges, a well-structured, risk-based approach to validation can ensure the integrity and compliance of cloud-based systems in pharmaceutical manufacturing.
文摘In this study, the simple DPPH UV-spectrophotometric analytical procedures were optimized and validated for the estimation of antioxidant properties in aerated, semi-aerated and non-aerated tea products as per the AOAC guidelines. The method was found to be simple, rapid, accurate and economical in estimating antioxidant properties in the different tea products. A (0.0100 ± 0.0001) g well ground tea sample was extracted directly in 80% v/v methanol in distilled water. The precision of the method had an RSD% of 1.695 with a linear relation equation of Y = 200.7X + 5.25 (r2 = 0.997). The method proved to be a reliable and effective tool in analysis of anti-oxidant properties in varied tea cultivars and their processed products.
基金Financial support provided by Correlated Solutions Incorporated to perform StereoDIC experimentsthe Department of Mechanical Engineering at the University of South Carolina for simulation studies is deeply appreciated.
文摘To compare finite element analysis(FEA)predictions and stereovision digital image correlation(StereoDIC)strain measurements at the same spatial positions throughout a region of interest,a field comparison procedure is developed.The procedure includes(a)conversion of the finite element data into a triangular mesh,(b)selection of a common coordinate system,(c)determination of the rigid body transformation to place both measurements and FEA data in the same system and(d)interpolation of the FEA nodal information to the same spatial locations as the StereoDIC measurements using barycentric coordinates.For an aluminum Al-6061 double edge notched tensile specimen,FEA results are obtained using both the von Mises isotropic yield criterion and Hill’s quadratic anisotropic yield criterion,with the unknown Hill model parameters determined using full-field specimen strain measurements for the nominally plane stress specimen.Using Hill’s quadratic anisotropic yield criterion,the point-by-point comparison of experimentally based full-field strains and stresses to finite element predictions are shown to be in excellent agreement,confirming the effectiveness of the field comparison process.
基金supported by the University of Sri Jayewardenepura(No. ASP/01/RE/AHS/2021/91)。
文摘Objective:Validation is an important aspect of an instrument,and it ensures the confidence of researchers to employ the instrument in their studies.This study was conducted to develop and validate an instrument to assess knowledge,attitudes,and practices(KAP) on digital health among nurses since digital health capacity is a major concern in health care that needs to be assessed.Methods:We conducted a methodological study to assess the content validity and reliability of the instrument.First,items were generated through a comprehensive literature review and by obtaining an expert opinion.Second,content and face validity were assessed by a panel of 7 experts.Both the item-level content validity index(I-CVI) and the scale-level content validity index(S-CVI) were established.Moreover,test–retest reliability and internal consistency of the instrument were assessed.Data were analyzed using SPSS version 25.Results:The initial pool consisted of 60 items and after obtaining content,face,and construct validity,51 items remained.Items with an I-CVI <0.78 were considered relevant.The S-CVI for relevancy,clarity,ambiguity,and simplicity were 0.93,0.91,0.94,and 0.92,respectively.Five subcomponents were constructed in each knowledge and attitudes domain,and the test–retest reliability test revealed that the instrument has good reliability,showing correlation coefficient values for the KAP domains and the total questionnaire of 0.76,0.98,0.99,and 0.99,respectively.The independent Cronbach's α for all items was 0.76,indicating good internal consistency.Conclusions:The present study established the acceptable validity and ensured the good reliability and internal consistency of the instrument,which can serve as an assessment tool of KAP on digital health among healthcare professionals.