期刊文献+
共找到13,545篇文章
< 1 2 250 >
每页显示 20 50 100
Experimental Investigation on System with Combination of Ground-Source Heat Pump and Solar Collector 被引量:4
1
作者 胡涛 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2013年第3期157-167,共11页
This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calcu... This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively. 展开更多
关键词 ground-source heat pump solar energy heating performance BOREHOLE heat EXCHANGER
下载PDF
Research on Performance of Ground-Source Heat Pump Double U Underground Pipe Heat Exchange 被引量:1
2
作者 Youyin Jing Jing Hou Peng Yang 《Open Journal of Modelling and Simulation》 2013年第1期1-6,共6页
This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the conditi... This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the condition of unsteady state long-term continuous running, analyzes the change of soil temperature filed around underground pipe and performance of underground pipe heat exchange between single U and double U pipe system. The results show that double U pipe system is better than single U system, which can improve unit depth heat exchange efficiency, reduce the number of wells and reduce the initial investment. 展开更多
关键词 ground-source heat pump DOUBLE U UNDERGROUND PIPE heat Exchange Soil Temperature Field
下载PDF
Optimized design and integration of energy storage in Solar-Assisted Ground-Source Heat Pump systems
3
作者 Maria Ferrara Enrico Fabrizio 《Building Simulation》 SCIE EI CSCD 2023年第10期1933-1948,共16页
The integrated use of multiple renewable energy sources to increase the efficiency of heat pump systems,such as in Solar Assisted Geothermal Heat Pumps(SAGHP),may lead to significant benefits in terms of increased eff... The integrated use of multiple renewable energy sources to increase the efficiency of heat pump systems,such as in Solar Assisted Geothermal Heat Pumps(SAGHP),may lead to significant benefits in terms of increased efficiency and overall system performance especially in extreme climate contexts,but requires careful integrated optimization of the different system components.In particular,thermal storages take a fundamental role in optimizing the integration of renewable energy sources and the system operation.This work investigates the potential design optimization of a SAGHP system in a mountain site by exploring many different alternatives to optimize the mutual relationship between the solar field,the geothermal field and the water thermal storages.This is done through an original simulation-based multi-objective optimization framework considering energy efficiency and economic feasibility,which allows appraising the impact of the different design alternatives on the overall system performance and on the dynamics of the different system components.Results identify a set of optimized system configurations that optimize the integrated exploitation of the different thermal sources showing a potential increase of the overall system performance leading to 34%lower global cost compared to the initial design.High robustness of the optimal design solutions is reported with respect to the current context of high economic uncertainty. 展开更多
关键词 thermal storage geothermal energy heat pumps building simulation artificial intelligence cost optimization energy flexibility
原文传递
Novel Radiation-Adjustable Heating Terminal Based on Flat Heat Pipe Combined with Air Source Heat Pump
4
作者 Yifan Wu Hongli Sun +3 位作者 Mengfan Duan Borong Lin Hengxin Zhao Chaohung Liu 《Engineering》 SCIE EI CAS CSCD 2023年第1期192-207,共16页
The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking c... The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking central heating. However, as a major component of space heating, heating terminals might not fit well with ASHP in order to achieve both intermittency and comfort. Therefore, this study proposes a novel radiation-adjustable heating terminal combined with an ASHP to achieve electrification, intermittency, and better thermal comfort. Radiant terminals currently suffer from three major problems: limited maximum heating capacity, inability to freely adapt, and difficulty with combining them with ASHPs. These problems were solved by improving the structural design of the novel terminal (Improvement A–E). Results showed that the maximum heating capacity increased by 23.6% and radiation heat transfer ratio from 10.1% to 30.9% was provided for users with the novel terminal. Further, new flat heat pipe (FHP) design improved stability (compressor oil return), intermittency (refrigerant thermal inertia), and safety (refrigerant leakage risk) by reducing the length of exposed refrigerant pipes. Furthermore, a new phased operation strategy was proposed for the novel terminal, and the adjustability of the terminal was improved. The results can be used as reference information for decarbonizing buildings by electrifying heating terminals. 展开更多
关键词 Novel heating terminal Air-source heat pump Structural impr ovement design Maximum heating capacity Rapid adjustability Room temperature distribution
下载PDF
Investigation of energy-efficient heat pump assisted heterogeneous azeotropic distillation for separating of acetonitrile/ethyl acetate/n-hexane mixture
5
作者 Xinhao Li Qing Ye +4 位作者 Jinlong Li Lingqiang Yan Xue Jian Licheng Xie Jianyu Zhang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第3期20-33,共14页
The conventional distillation is hard to accomplish the separation of acetonitrile/ethyl acetate/n-hexane mixture. Herein, a heterogeneous azeotropic distillation(HAD) without adding entrainer is proposed to separate ... The conventional distillation is hard to accomplish the separation of acetonitrile/ethyl acetate/n-hexane mixture. Herein, a heterogeneous azeotropic distillation(HAD) without adding entrainer is proposed to separate ternary mixture. The proposed scheme is optimized via the simulated annealing algorithm and minimum total annual cost(TAC) is used as objective functions. To minimize energy consumption,heat pump is added on the basis of optimal heterogeneous azeotropic distillation and heat integration technology is used to further improve the energy recovery. The TAC, gas emission, energy consumption and exergy destruction are used to discuss the economy and environmental protection of processes.Among all the processes, the heat pump with higher preheating temperature(HPT) assisted HAD process by combining with heat integration(HAD-HPT-HI) has best performances on economic, environment,energy and exergy. Compared with conventional HAD process, the HAD-HPT-HI achieves the reductions of 52.17%, 68.86%, 65.87% and 65.46% on TAC, total energy consumption, gas emissions and exergy destruction, respectively. 展开更多
关键词 Heterogeneous azeotropic distillation ENERGY-SAVING SA algorithm heat pump
下载PDF
Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
6
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
7
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
Synthesis and Design of Distillation Columns for Wide-Boiling Binary Mixtures with Vapor Recompression Heat Pumps
8
作者 Shi Li 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS CSCD 2023年第4期127-138,共12页
The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column... The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column. However, the separation of wide-boiling binary mixtures leads to substantial temperature differences between the top and bottom of the column. This limits the applicability of conventional VRHP due to high capital costs and strict performance requirements of the compressor. To overcome these challenges and to accommodate compressor operating conditions, a novel synthesis and design method is introduced to integrate VRHPs with wide-boiling binary mixture distillation columns(WBMDCs). This method enables quick determination of an initial configuration for the integrated WBMDC-VRHP system and helps identify the optimum configuration with the minimum total annual cost. Two examples, namely the separation of benzene/toluene and isopropanol/chlorobenzene, are employed to derive optimum configurations of the WBMDC-VRHP and compare them with the WBMDC. A systematic comparison between the WBMDC-VRHP and WBMDC demonstrates the superior steady-state performance and economic efficiency of the WBMDC-VRHP. 展开更多
关键词 vapor recompression heat pump wide-boiling binary mixtures distillation column energy saving synthesis and design
下载PDF
Exergo-Environmental Study of a Recent Organic Solar Hybrid Heat Pump
9
作者 Rabeb Toujani Nahla Bouaziz 《Fluid Dynamics & Materials Processing》 EI 2023年第4期991-1001,共11页
A hybrid heat pump(compression/absorption)with an integrated thermal photovoltaic unit is studied.The considered working fluids are organic mixtures:R245fa/DMAC and R236fa/DMAC,chosen for their low Global Warming Pote... A hybrid heat pump(compression/absorption)with an integrated thermal photovoltaic unit is studied.The considered working fluids are organic mixtures:R245fa/DMAC and R236fa/DMAC,chosen for their low Global Warming Potential.The main objective is the optimization of energy efficiency in order to minimize the environmental impact through the implementation of a sustainable strategy.It is shown that Exergy Analysis itself is a valuable tool in energy integration.Within the imposed framework of minimizing total annual costs,entropy analysis can be instrumental in determining the optimal plant concept,optimizing energy conversion and use,and improving profitability.The present results are discussed under the optimistic hope that they may help to define new energy and environmental policies. 展开更多
关键词 Impact environmental exergy analysis CO_(2)emissions solar hybrid heat pump
下载PDF
Thermo-Economic Performance of Geothermal Driven High-Temperature Flash Tank Vapor Injection Heat Pump System:A Comparison Study
10
作者 Huashan Li Xiaoshuang Zhao +2 位作者 Sihao Huang Lingbao Wang Jiongcong Chen 《Energy Engineering》 EI 2023年第8期1817-1835,共19页
Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is... Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price. 展开更多
关键词 Geothermal water high-temperature heat pump flash tank vapor injection thermo-economic performance
下载PDF
Impact of the Heat Pump on the Environment
11
作者 Jovan Mitrović 《Journal of Power and Energy Engineering》 2023年第6期26-33,共8页
The paper deals with the impact of a mechanical compression heat pump, operated by electrical energy, on the environment. Irrespective of its origin and the history of its production, this energy pollutes the environm... The paper deals with the impact of a mechanical compression heat pump, operated by electrical energy, on the environment. Irrespective of its origin and the history of its production, this energy pollutes the environment as waste heat. The operational energy, obtained from the so-called alternative energy sources (wind, water energy), also burdens the environment as waste heat. This is not the case with the solar energy. A direct conversion of the Sun’s rays into electricity does not additionally affect the environment, compared to their direct conversion into heat without our intervention. 展开更多
关键词 heat pump ENVIRONMENT
下载PDF
Simulation Study of the Control Strategy of a DC Inverter Heat Pump Using a DC Distribution Network
12
作者 Siwei Han Xianglong Li +3 位作者 Wei Zhao Linyu Wang Anqi Liang Shuang Zeng 《Energy Engineering》 EI 2023年第6期1421-1444,共24页
Photovoltaics,energy storage,direct current and flexibility(PEDF)are important pillars of achievement on the path to manufacturing nearly zero energy buildings(NZEBs).HVAC systems,which are an important part of public... Photovoltaics,energy storage,direct current and flexibility(PEDF)are important pillars of achievement on the path to manufacturing nearly zero energy buildings(NZEBs).HVAC systems,which are an important part of public buildings,play a key role in adapting to PDEF systems.This research studied the basic principles and operational control strategies of a DC inverter heat pump using a DC distribution network with the aim of contributing to the development and application of small DC distribution systems.Along with the characteristics of a DC distribution network and different operating conditions,a DC inverter heat pump has the ability to adapt to changes in the DC bus voltage and adds flexibility to the system.Theoretical models of the DC inverter heat pump integrated with an ice storage unit were developed.The control strategies of the DC inverter heat pump system considered the influence of both room temperature and varied bus voltage.A simulation study was conducted using MATLAB&Simulink software with simulation results validated by experimental data.The results showed that:(1)The bus fluctuation under the rated working voltage had little effect on the operation of the unit;(2)When the bus voltage was fluctuating from 80%-90%or 105%-107%,the heat pump could still operate normally by reducing the frequency;(3)When the bus voltage was less than 80%or more than 107%,the unit needed to be shut down for the sake of equipment safety,so that the energy storage device could adjust to the sharp decrease or rise of voltage. 展开更多
关键词 Photovoltaics energy storage direct current and flexibility DC inverter heat pump MATLAB&Simulink control strategy
下载PDF
Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens 被引量:4
13
作者 LIU Zhong-bing,ZHANG Ling,YANG Zhang,XU Ming,HAN Tian-he(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期131-135,共5页
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff... A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient. 展开更多
关键词 THERMOELECTRIC heat pump KITCHENS EXHAUST water heatER COEFFICIENT of performance
下载PDF
Multi-Effect Evaporation Coupled with MVR Heat Pump Thermal Integration Distillation for Separating Salt Containing Methanol Wastewater 被引量:3
14
作者 Deming Yang Yifan Yin +2 位作者 Zhengguang Wang Biyun Zhu Qiang Gu 《Energy and Power Engineering》 2017年第12期772-785,共14页
Due to the high energy consumption for separation of salt containing methanol wastewater, in this work, the multi-effect evaporation coupled with mechanical vapor recompression (MVR) heat pump and thermal integration ... Due to the high energy consumption for separation of salt containing methanol wastewater, in this work, the multi-effect evaporation coupled with mechanical vapor recompression (MVR) heat pump and thermal integration technologies were raised for the first time. The ELECNRTL thermodynamic model is used to simulate and optimize the evaporation rectification process. Energy consumption and total annual cost (TAC) are taken as objective functions. The results show that multi-effect evaporation coupled with conventional distillation process can save energy consumption and TAC by 44.12% and 39.14%. The multi-effect evaporation coupled with distillation process based on MVR heat pump technology can save energy consumption and TAC by 55.27% and 47.49%, which is super to three-effect evaporation coupled with conventional distillation process. The three-effect evaporation coupled with MVR heat integration process can save energy consumption and TAC by 81.32% and 58.55%, which is more economical than other processes. It can be clearly seen that three-effect evaporation coupled with MVR heat integration process is more competitive to deal with the salt containing methanol wastewater. 展开更多
关键词 Salt Containing METHANOL Wastewater MVR heat pump heat Integration Energy SAVING
下载PDF
Simulation of embedded heat exchangers of solar aided ground source heat pump system 被引量:1
15
作者 王芳 郑茂余 +1 位作者 邵俊鹏 李忠建 《Journal of Central South University》 SCIE EI CAS 2008年第S2期261-266,共6页
Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar ene... Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar energy collected in three seasons was stored in the soil by vertical U type soil exchangers. The heat abstracted by the ground-source heat pump and collected by the solar collector was employed to heating. Some of the soil heat exchangers were used to store solar energy in the soil so as to be used in next winter after this heating period; and the others were used to extract cooling energy directly in the soil by circulation pump for air conditioning in summer. After that solar energy began to be stored in the soil and ended before heating period. Three dimensional dynamic numerical simulations were built for soil and soil heat exchanger through finite element method. Simulation was done in different strata month by month. Variation and restoration of soil temperature were studied. Economy and reliability of long term SAGSHP system were revealed. It can be seen that soil temperature is about 3 ℃ higher than the original one after one year's running. It is beneficial for the system to operate for long period. 展开更多
关键词 SOLAR assisted ground source heat pump (ASGSHP) soil storage three DIMENSIONAL simulations heatING and COOLING
下载PDF
Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System 被引量:1
16
作者 SU Shun-yu,ZHANG Chun-zhi,CHEN Jian(College of Urban Construction,Wuhan University of Science and Technology,Wuhan,Hubei 430070,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期91-95,共5页
This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.... This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary. 展开更多
关键词 air-source heat pump control strategy distributed PARAMETER model CHARGE INVENTORY
下载PDF
Research on single hole heat transfer power of ground source heat pump system 被引量:1
17
作者 ZHAO Fang-hua 《Journal of Groundwater Science and Engineering》 2018年第1期65-70,共6页
In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfe... In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfer power per meter in summer is 97.1% of the test data,and the average value accounts for 81.8%.The per meter heat power data through on-site thermal response test can provide references for designing engineering project and optimizing ground source heat pump system as these data do not vary greatly from the actual monitoring data. 展开更多
关键词 GROUND source heat pump Monitoring heat TRANSFER POWER Thermal response test
下载PDF
Study on ground source heat pump system zoning and methods in the Northwest of Shandong Province 被引量:1
18
作者 YU Yi-qiang 《Journal of Groundwater Science and Engineering》 2018年第3期171-177,共7页
Based on the basic geology, hydrogeology, engineering geology, geothermal geology and ground source heat pump(GSHP) engineering of the work space, the thesis studies the local shallow geothermal energy. Three conditio... Based on the basic geology, hydrogeology, engineering geology, geothermal geology and ground source heat pump(GSHP) engineering of the work space, the thesis studies the local shallow geothermal energy. Three conditions of the attribute index for the suitability zoning of the northwest of Shandong are determined, namely, hydrodynamic condition, geological and hydrogeological condition and geological environment condition. The assessment result is that the total area of the suitable zone is 205.88 km^2, that of relative suitable zone, 1 407.76 km^2, and that of unsuitable zone, 286.8 km^2. The result conforms to the real development situation and provides experience for similar regions needed for selecting and assigning a value to suitability zoning of GSHP. 展开更多
关键词 Ground source heat pump NORTHWEST of SHANDONG Province Engineering GEOLOGY SUITABILITY ZONING
下载PDF
Reaction Rate Characteristics of SrBr2 Hydration System for Chemical Heat Pump Cooling Mode 被引量:2
19
作者 Takehiro Esaki Noriyuki Kobayashi 《Journal of Materials Science and Chemical Engineering》 2016年第2期106-115,共10页
Here, we propose a chemical heat pump chiller with a SrBr<sub>2</sub> hydration reaction system for utilization of waste heat. The SrBr<sub>2</sub> hydration reaction could recover waste heat i... Here, we propose a chemical heat pump chiller with a SrBr<sub>2</sub> hydration reaction system for utilization of waste heat. The SrBr<sub>2</sub> hydration reaction could recover waste heat in low temperatures ranging from 373 K to 353 K, and the system showed good potential in terms of the high cooling thermal-storage density. Previous studies have given little information on the reaction characteristics of the SrBr<sub>2</sub> hydration reaction. In this paper, we developed a measuring method for the hydration reaction equilibrium and reaction rate based on the volumetric method. We analyzed the hydration reaction rate with an unreacted-core shell model. In the experiments, the SrBr<sub>2</sub> equilibrium temperature observed was equal to the theoretical equilibrium temperature obtained from thermodynamic databases. In addition, the hysteresis gap between the hydration and dehydration values was 2.0 K. Thus, the hysteresis effect was negligible for the chemical heat pump cooling operation. The reaction fraction of the SrBr<sub>2</sub> hydration reached 0.7 within 20 s. By analyzing the hydration reaction rate with the unreacted-core shell model, the activation energy value was calculated to be56.6 kJ/mol. The calculation results showed good agreement with those of the experiment as the reaction fraction reached 0.7. 展开更多
关键词 Chemical heat pump SrBr2 Hydration HYSTERESIS Unreacted-Core Shell Model
下载PDF
The Efficiency Analysis of the Exhaust Air Heat Pump System 被引量:1
20
作者 Alo Mikola Teet-Andrus Koiv 《Engineering(科研)》 2014年第13期1037-1045,共9页
This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air h... This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5. 展开更多
关键词 heat pump Exhaust Air heat pump heat Recovery heat Requirement COP The Coefficient of Performance