Bonding stress—slip constitutive behavior between bars and grout concrete 被引量:1
1
作者 郑怡 刘明 +1 位作者 周静海 王冰 《Journal of Central South University》 SCIE EI CAS 2009年第5期841-844,共4页
To establish bonding stress—slip constitutive model between bars and grout concrete,13 test specimens were employed to study the bonding behavior and the force transfer of bars adhered to grout concrete. The bonding ... To establish bonding stress—slip constitutive model between bars and grout concrete,13 test specimens were employed to study the bonding behavior and the force transfer of bars adhered to grout concrete. The bonding stress development of bars adhered to grout concrete was analyzed. The local bonding stress—slip curve was obtained. Based on the test results,a new bonding stress— slip constitutive model between bars and grout concrete was proposed. The results show that the maximum bonding stress is not influenced by the bar bond length,but it is strengthened when the splitting strength of grout concrete is increased. The model matches the experimental results well,and the regressing coefficient equals 1.7. 展开更多
关键词 grout concrete reinforced masonry constitutive model splitting strength bonding stress SLIP
下载PDF
Experimental study on the compressive strength of grouted concrete block masonry based on nondestructive detection methods 被引量:1
2
作者 姜洪斌 李龙飞 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2009年第2期189-193,共5页
Existing nondestructive detection methods were adopted to test the compressive strength of grouted concrete block masonry,i.e.the rebound method,pulling-out method and core drilling method were employed to test the st... Existing nondestructive detection methods were adopted to test the compressive strength of grouted concrete block masonry,i.e.the rebound method,pulling-out method and core drilling method were employed to test the strength of block,mortar and grouted concrete,respectively.The suitability of these methods for the testing of strength of grouted concrete block masonry was discussed,and the comprehensive strength of block masonry was appraised by combining existing nondestructive or micro-destructive detection methods.The nondestructive detection test on 25 grouted concrete block masonry specimens was carried out.Experimental results show that these methods mentioned above are applicable for the strength detection of grouted concrete block masonry.Moreover,the formulas of compressive strength,detection methods and proposals are given as well. 展开更多
关键词 grouted concrete block masonry compressive strength nondestructive detection
下载PDF
Effect of bolt rib spacing on load transfer mechanism 被引量:4
3
作者 Wu Tao Cao Chen +1 位作者 Han Jun Ren Ting 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2017年第3期431-434,共4页
Rock bolting has firmly used as the coal mine roof reinforcement in underground coal mine. The bolting effect of fully grouted rebar bolt is closely related to the bolt surface profile. This paper provides an experime... Rock bolting has firmly used as the coal mine roof reinforcement in underground coal mine. The bolting effect of fully grouted rebar bolt is closely related to the bolt surface profile. This paper provides an experimental study to confirm that bolt rib internal length has great influence on bolting effect. Pull-out tests were conducted using rebar bolt with different rib spacings of 12, 24, 36 and 48 mm representatively from steel tube and from concrete. Results show that peak load increases 25.3% for bolt with large rib spacing. For pull out using concrete block, the increment of peak load between large and small rib spacing is not significant, but the bolt with large rib spacing has great absorption of deformational energy than small rib spacing bolt. This study provides experimental evidence towards optimum design of rock bolt for understand coal mining industry. 展开更多
关键词 Fully grouted bolt Profile study Rib spacing Pullout from concrete