Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave pr...Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line.展开更多
Ultrasonic guided wave becomes one of promising tool for monitoring various types of structures such as large steel plates, vessels, and pipes in oil, chemical or nuclear industry, because guided waves have ability to...Ultrasonic guided wave becomes one of promising tool for monitoring various types of structures such as large steel plates, vessels, and pipes in oil, chemical or nuclear industry, because guided waves have ability to travel wide range of the target structure in a single position. However, analysis of guided wave signals acquired from structure is difficult on account of low S/N ratio and its dispersive nature. To improve S/N ratio and overcome dispersion effect, focusing techniques for guided waves are needed. Thus, in this study, focusing techniques for guided waves were developed in order to improve long range inspection ability, and performance of the developed techniques was verified by experiments.展开更多
基金Supported by National Natural Science Foundation of China(Grant No51605229)Natural Science Foundation of Higher Education Institutions of Jiangsu Province,China(Grant No.16KJB460016)+1 种基金the“333”Project of Jiangsu Province,China(Grant No.BRA2015310)China Postdoctora Science Foundation(Grant No.2016M601844)
文摘Due to the merits of high inspection speed and long detecting distance, Ultrasonic Guided Wave(UGW) method has been commonly applied to the on-line maintenance of power transmission line. However, the guided wave propagation in this structure is very complicated, leading to the unfavorable defect localization accuracy. Aiming at this situation, a high precision UGW technique for inspection of local surface defect in power transmission line is proposed. The technique is realized by adopting a novel segmental piezoelectric ring transducer and transducer mounting scheme, combining with the comprehensive characterization of wave propagation and circumferential defect positioning with multiple piezoelectric elements. Firstly, the propagation path of guided waves in the multi-wires of transmission line under the proposed technique condition is investigated experimentally. Next, the wave velocities are calculated by dispersion curves and experiment test respectively, and from comparing of the two results, the guided wave mode propagated in transmission line is confirmed to be F(1,1) mode. Finally, the axial and circumferential positioning of local defective wires in transmission line are both achieved, by using multiple piezoelectric elements to surround the stands and send elastic waves into every single wire. The proposed research can play a role of guiding the development of highly effective UGW method and detecting system for multi-wire transmission line.
基金the National Research Foundation of Korea Grant funded by the Korean Government(MEST)(NRF-2009-0076791) by the National Natural Science Foundation of China(NSFC)
文摘Ultrasonic guided wave becomes one of promising tool for monitoring various types of structures such as large steel plates, vessels, and pipes in oil, chemical or nuclear industry, because guided waves have ability to travel wide range of the target structure in a single position. However, analysis of guided wave signals acquired from structure is difficult on account of low S/N ratio and its dispersive nature. To improve S/N ratio and overcome dispersion effect, focusing techniques for guided waves are needed. Thus, in this study, focusing techniques for guided waves were developed in order to improve long range inspection ability, and performance of the developed techniques was verified by experiments.