期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Indispensable gutter layers in thin-film composite membranes for carbon capture
1
作者 Gengyi Zhang Haiqing Lin 《Green Energy & Environment》 SCIE EI CAS CSCD 2024年第8期1220-1238,共19页
Industrial thin-film composite(TFC)membranes achieve superior gas separation properties from high-performance selective layer materials,while the success of membrane technology relies on high-performance gutter layers... Industrial thin-film composite(TFC)membranes achieve superior gas separation properties from high-performance selective layer materials,while the success of membrane technology relies on high-performance gutter layers to achieve production scalability and low-cost manufacturing.However,the current literature predominantly focuses on the design of polymer architectures to obtain high permeability and selectivity,while the art of fabricating gutter layers is usually safeguarded by industrial manufacturers and appears lackluster to academic researchers.This is the first report aiming to provide a comprehensive and critical review of state-of-the-art gutter layer materials and their design and modification to enable TFC membranes with superior separation performance.We first elucidate the importance of the gutter layer on membrane performance through modeling and experimental results.Then various gutter layer materials used to obtain high-performance composite membranes are critically reviewed,and the strategies to improve their compatibility with the selective layer are highlighted,such as oxygen plasma treatment,polydopamine deposition,and surface grafting.Finally,we present the opportunities of the gutter layer design for practical applications. 展开更多
关键词 Thin-film composite membranes Gutter layer Gas separation Carbon capture
下载PDF
Comparing the reinforcement capacity of welded steel mesh and a thin spray-on liner using large scale laboratory tests 被引量:7
2
作者 Zhenjun Shan Porter Ian +1 位作者 Nemcik Jan Baafi Ernest 《International Journal of Mining Science and Technology》 SCIE EI 2014年第3期373-377,共5页
Steel mesh is used as a passive skin confinement medium to supplement the active support provided by rock bolts for roof and rib control in underground coal mines. Thin spray-on liners(TSL) are believed to have the po... Steel mesh is used as a passive skin confinement medium to supplement the active support provided by rock bolts for roof and rib control in underground coal mines. Thin spray-on liners(TSL) are believed to have the potential to take the place of steel mesh as the skin confinement medium in underground mines.To confirm this belief, large scale laboratory experiments were conducted to compare the behaviour of welded steel mesh and a TSL, when used in conjunction with rock bolts, in reinforcing strata with weak bedding planes and strata prone to guttering, two common rock conditions which exist in coal mines. It was found that while the peak load taken by the simulated rock mass with weak bedding planes acting as the control sample(no skin confinement) was 2494 kN, the corresponding value of the sample with 5 mm thick TSL reinforcement reached 2856 kN. The peak load of the steel mesh reinforced sample was only2321 kN, but this was attributed to the fact that one of the rock bolts broke during the test. The TSL reinforced sample had a similar post-yield behaviour as the steel mesh reinforced one. The results of the large scale guttering test indicated that a TSL is better than steel mesh in restricting rock movement and thus inhibiting the formation of gutters in the roof. 展开更多
关键词 Steel mesh Thin spray-on liners Large scale laboratory experiments Strata with weak bedding planes Strata prone to guttering
下载PDF
Preparation of composite poly(ether block amide)membrane for CO_2 capture 被引量:4
3
作者 Lianjun Wang Yang Li +2 位作者 Shuguang Li Pengfei Ji Chengzhang Jiang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2014年第6期717-725,共9页
In this study, a poly(ether block amide) (Pebax 1657) composite membrane applied for COa capture was prepared by coating Pebax 1657 solution on polyacrylonitrile (PAN) ultrafiltration membrane. Ethanol/water mix... In this study, a poly(ether block amide) (Pebax 1657) composite membrane applied for COa capture was prepared by coating Pebax 1657 solution on polyacrylonitrile (PAN) ultrafiltration membrane. Ethanol/water mixture was used as the solvent of Pebax and the effects of ethanol/water mass ratios and Pebax concentration on the permeation properties of composite membrane were studied. To enhance the com- posite membrane permeance, the gutter layer, made from reactive amino silicone crosslinking with potydimethylsiloxane (PDMS), was de- signed. The influence of crosslinldng degree of the gutter layer on membrane performance was investigated. As a result, a Pebardamino- PDMS/PAN multilayer membrane with hexane resistance was developed, showing CO2 permeance of 350 GPU and CO2/N2 selectivity over 50. The blend of polyethylene glycol dimethyl ether (PEG-DME) with Pebax as coating material was studied to further improve the membrane performance. After being combined with PEG-DME additive, CO2 permeance of the final Pebax-PEG-DME/amino-PDMS/PAN composite membrane reached 400 GPU above with CO2/Na selectivity over 65. 展开更多
关键词 CO2 capture composite membrane gutter layer COATING
下载PDF
Numerical Analysis of Tilted Cutting and F128 Brushes
4
作者 Libardo V.Vanegas-Useche Magd M.Abdel-Wahab Graham A.Parker 《Computer Modeling in Engineering & Sciences》 SCIE EI 2019年第10期23-47,共25页
Road sweeping is an essential service that has to be conducted for public health,as well as aesthetic purposes.In many countries,sweeping vehicles are used for this activity.They usually comprise a gutter brush that s... Road sweeping is an essential service that has to be conducted for public health,as well as aesthetic purposes.In many countries,sweeping vehicles are used for this activity.They usually comprise a gutter brush that sweeps the debris that is located in the road gutter.This work studies the performance of two kinds of gutter brushes:a cutting brush and a flicking(F128)brush.This is carried out by means of a 3-D dynamic,nonlinear Finite Element(FE)brush model developed by the authors.In this model,inertia forces are applied to the bristle,and its clamped end is fixed.Consequently,the surface(road)is rotated,translated,and raised.Bristle-road interaction is modelled as flexible-to-rigid contact.In particular,the aim of this article is to compare the performance of a conventional brush and a brush rotating at variable speed.As brushes normally work tilted,FE analyses are carried out for tilted cutting and F128 brushes,rotating at speeds that fluctuate at different frequencies.It is concluded that brush oscillations have a significant effect on bristle tip velocities and bristle-road forces.Also,at certain frequencies,oscillations seem to improve sweeping performance of the F128 brush.However,they do not appear to improve significantly the performance of the cutting brush. 展开更多
关键词 GUTTER BRUSHES CUTTING BRUSH flicking BRUSH FEM variable speed BRUSHING
下载PDF
Characterization and Application of the Makoua Clay in the Chemical and Bacteriological Depollution of Gutter and Well Waters of Brazzaville
5
作者 Ferland Ngoro-Elenga Atipo Itoua Ngopoh +3 位作者 Hilaire Elenga Jean-Romuald Mambou Jude Novelgi Ngakosso Ngolo Timothée Nsongo 《Materials Sciences and Applications》 2021年第6期263-275,共13页
In this work, the authors made aquatic filters according to the formulation “clay stabilized at 4% of cement mixed with 4% of kambala sawdust and 10% of white sand” then heated to 1050°C to decontaminate the wa... In this work, the authors made aquatic filters according to the formulation “clay stabilized at 4% of cement mixed with 4% of kambala sawdust and 10% of white sand” then heated to 1050°C to decontaminate the waters of gutters and wells. The authors carried out geotechnical, geochemical, thermal, infrared spectroscopy, and scanning electron microscopy that analyzed the clay material. Geotechnical analyzes have shown that this material is made up of 22% thin sand, 22% of silt, and 56% of clay with 26 plasticity index. The geochemical analysis showed the presence of trace elements shared out as follows: 3% of alkaline metals, 24% of alkaline earth metals, 46% of transition metals, 10% of metal, 16% of lanthanides, 1% of actinides. The most abundant trace elements are barium (19%), vanadium (12%), chromium (11%) and zinc (9%). The thermal and microscopic analyzes revealed the kaolinitic nature of materials. The chemical depollution studies have shown elimination yields of 50% - 52.38% of sulphates;77.33% - 85.19% of phosphates;34.85% - 88.49% nitrates;91.3 - 100 of sulphides;The removal of bacteriological pollution are 92.8% - 98% of total germs;94% - 97% of total coliform and 95% - 98% of <em>E. coli</em>. 展开更多
关键词 Clay Characterization Chemical Depollution Bacteriological Depollution Gutter and Well Water Makoua
下载PDF
Total Peritoneal Gutter Removal versus Random Peritoneal Biopsy in Cases of Ovarian Cancer
6
作者 Ahmed Abdel-Azeem Essmat Mahmoud El-Sayed Meleis +2 位作者 Helmy Abdel-Sattar Rady Inass Ibrahim Ahmed Zaki Ahmed Shaaban Ali Ragab Khattab 《Open Journal of Obstetrics and Gynecology》 2021年第10期1342-1350,共9页
<strong>Introduction:</strong><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> Ovarian cancer is the... <strong>Introduction:</strong><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> Ovarian cancer is the fourth most prevalent cancer among </span></span></span><span><span><span style="font-family:""><span style="font-family:Verdana;">women and the seventh most common cancer overall. Every year, an estimated 200,000 cases and 125,000 deaths related to ovarian cancer are reported around the world. It is most common in high-resource countries, with an incidence rate of 9.3 per 100,000 women.</span><sup> </sup><span style="font-family:Verdana;">Ovarian cancer is detected at an advanced stage in about 70% of instances, and only 30% of women with such cancers live for more than 5 years. Although only around 20% of ovarian cancers are limited to the ovaries at diagnosis, patients with localized disease have a 5-year survival rate of more than 90%.</span><sup> </sup><span style="font-family:Verdana;">Peritonectomy is a crucial part of the surgical treatment for ovarian cancer. Visual inspection and palpation are not reliable methods for determining the extent of tumour involvement. The majority of gynecologic oncologists are suspicious about the benefits of a full peritonectomy, concerned about the benefits and hazards. They believe that the tumor’s fundamental biology, not surgical aggressiveness, dictates the tumor’s resectability. The aim of this work was primarily to compare the differences between total peritoneal gutter removal and random peritoneal biopsy in cases of early ovarian cancer. A secondary aim of this work is to show ability of total peritoneal gutter removal in relation to that of random peritoneal biopsy to detect positivity of metastasis in the histopathological specimens. </span><b><span style="font-family:Verdana;">Patients and Methods: </span></b><span style="font-family:Verdana;">This prospective cohort study was conducted on 130 patients with early ovarian cancer in El-Shatby hospital, Faculty of Medicine, Alexandria University. For each patient, we took random and total peritoneal biopsy and compared between them regarding technique, timing, post-operative complications, and histopathological results. Inclusion criteria:</span><b> </b><span style="font-family:Verdana;">all age group, suspected ovarian cancer using IOTA score, absence of nodules in the peritoneal gutter using CT and any case that needs staging laparotomy for ovarian cancer.</span><b> </b><span style="font-family:Verdana;">Exclusion criteria:</span><b> </b><span style="font-family:Verdana;">presence of gross peritoneal disease in </span><span style="font-family:Verdana;">the gutter and CT features of advanced ovarian cancer (peritoneal deposits,</span> <span style="font-family:Verdana;">omental cakes, pelvic and para-aortic lymphadenopathy). All cases will be</span><span style="font-family:Verdana;"> subjected to the followings: history taking, clinical examination, suspicious ovarian mass using IOTA score, tumor markers, CT staging, staging laparotomy and random and total peritoneal biopsies will be collected from the same case and sent to the lab of pathology for histopathological examination and the results will be compred regarding positivity of metastasis. </span><b><span style="font-family:Verdana;">Results: </span></b><span style="font-family:Verdana;">Random peritoneal biopsy showed positive metastasis in 6 (4.6%) cases and free in 124 (95.4%) cases while total peritoneal gutter removal showed positive metastasis </span><span style="font-family:Verdana;">in 19 (14.6%) cases and free in 111 (85.4%) with Chi-square test was 7.479</span><span style="font-family:Verdana;"> and P value was 0.004 which is statistically significant. 108 (97.3%) cases had negative random peritoneal biopsy and negative total peritoneal gutter removal, 3 (2.7%) cases had positive random peritoneal biopsy and negative total peritoneal gutter removal, 16 (84.2%) cases had positive total peritoneal gutter removal and negative random peritoneal biopsy & 3 (15.8%) cases had positive total peritoneal gutter removal and positive random peritoneal biopsy with Chi-square test 6.311, </span><sup><span style="font-family:Verdana;">FE</span></sup><span style="font-family:Verdana;">p 0.04 and Kappa test 0.183 (0.012) which is statistically significant with poor strength of agreement. </span><b><span style="font-family:Verdana;">Conclusions: </span></b><span style="font-family:Verdana;">Modified total peritoneal gutter removal is a safe, fast and easy technique com</span><span style="font-family:Verdana;">pared to random peritoneal biopsy and even to traditional peritonectomy</span><span style="font-family:Verdana;"> procedure with high detection rates of peritoneal involvement with sensitivity of 50% and specificity of 87.5% and it is recommended to be done as a routine alternative to random peritoneal biopsy and even to traditional total gutter removal in all cases of ovarian malignancies for diagnostic and therapeutic values</span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">.</span></span></span> 展开更多
关键词 Pelvic Peritonectomy Gutter Resection Ovarian Cancer
下载PDF
网站推荐
7
《计算机光盘软件与应用(COMPUTER ARTS数码艺术)》 2004年第10期10-10,共1页
关键词 The Running FISH GUTTER Togge MAGAZINE Barttomie Rozbicki 网站
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部