Flame Thermal Spray (FTS) coatings frequently show some porosity and reduced adherence to substrate, which affect its properties, especially its corrosion resistance. In this work, the corrosion resistance of AISI 101...Flame Thermal Spray (FTS) coatings frequently show some porosity and reduced adherence to substrate, which affect its properties, especially its corrosion resistance. In this work, the corrosion resistance of AISI 1018 carbon steel coated by different methods is compared: electroless nickel (EN) coating, NiCrFeBSi obtained by FTS, duplex coatings of an EN deposit on a layer of NiCrFeBSi obtained by FTS and a layer of NiCrFeBSi on an EN deposit. The coatings were characterized using optical microscopy and scanning electron microscopy techniques, EDS microprobe microanalysis, roughness as well as electrochemical polarization tests to obtain the corrosion rate. The results show the enhancement in the corrosion resistance in saline medium of the duplex coatings, especially of the EN coating on FTS layer.展开更多
This study was to develop the flame retardant (FR) protective clothing which had multifunction such anti-bacterial, UV cut, FR function with water repellent and water vapor permeable laminating textiles for industrial...This study was to develop the flame retardant (FR) protective clothing which had multifunction such anti-bacterial, UV cut, FR function with water repellent and water vapor permeable laminating textiles for industrial workers. First of all, the FR yarn and FR textiles were developed for this purpose. Second, the comparison analysis between the halogen laminating textiles and halogen-free laminating textiles were tested to figure out the eco-friendly laminating method. Third, the flame retardant ability was compared the halogen laminated textiles to halogen-free laminated textiles. LOI, UV protection ratio, antibiosis after 50 laundry test, water proof pressure, and moisture permeability of developed textiles were tested. GC-HR-TOF-MS was used for analysis of laminating film (halogen and halogen-free). 4.1 wt% TiO2 yarn showed antibacterial function (Pneumococcus & Staphylococcus aureus: 99.9%), UV Protection (UVA: 90.8, UVB: 92.1), and LOI (33.6). The chosen optimal compounding ratio for PU compound of HRF and HFFR were as followed: PU resin 58.3%, DMF (Dimethyl formamide, δ = 12.2) 8.3%, MEK (Methylethylketone) 8.3% and FR (flame retardants) 25.0%. Binder for laminating should not be included over 10% of FRs because of adhesion between textiles and FR laminating film. There were detected phosphorus compounds in the textiles treated by halogenated type flame retardants and halogenated-free type flame retardants. There were not any detected harmful compounds from all textile samples.展开更多
The fibred magnesium hydroxide from the bracite was treated with a surface active agent. The modified fibred magnesium hydroxide as flame-retardant, boric acid, barium stearate, polydimethyl siloxane fluid, vinyltrie...The fibred magnesium hydroxide from the bracite was treated with a surface active agent. The modified fibred magnesium hydroxide as flame-retardant, boric acid, barium stearate, polydimethyl siloxane fluid, vinyltriethoxysilane as synergists of the flame-retardant were added to polyene resin. The flame-resistance polyene material prepared meets the requirements of EWCZ-6287-1. (Author abstract) 2 Refs.展开更多
Organic dust flames deal with a field of science in which many complicated phenomena like pyrolysis or devolatization of solid particles and combustion of volatile particles take place. One-dimensional flame propagati...Organic dust flames deal with a field of science in which many complicated phenomena like pyrolysis or devolatization of solid particles and combustion of volatile particles take place. One-dimensional flame propagation in cloud of fuel mixture is analyzed in which flame structure is divided into three zones. The first zone is preheat zone in which rate of the chemical reaction is small and transfer phenomena play significant role in temperature and mass distributions. In this model, it is assumed that particles pyrolyze first to yield a gaseous fuel mixture. The second zone is reaction zone where convection and vaporization rates of the particles are small. The third zone is convection zone where diffusive terms are negligible in comparison of other terms. Non-zero Biot number is used in order to study effect of particles thermal resistance on flame characteristics. Also, effect of particle size on combustion of micro organic dust is investigated. According to obtained results, it is understood that both flame temperature and burning velocity decrease with rise in the Biot number and particle size.展开更多
The efficiency of different intumescent flame-retardant (IFR) formulations designed to improve the flame resistance of fluoroelastomer ( FKM ) composites was studied. The proportion of ammonium polyphosphate (APP...The efficiency of different intumescent flame-retardant (IFR) formulations designed to improve the flame resistance of fluoroelastomer ( FKM ) composites was studied. The proportion of ammonium polyphosphate (APP) with charring-foaming agent (CFA) in IFR systems, and the addi- tion of synergists zinc borate (ZB) and ketonealdehyde resin ( KR120 ) were investigated to show their effect on flame resistance of FKM. According to flame resistance tests, when the mass ratio of APP to CFA was 4:1 as well as the loadings of IFR, ZB, KR120 were 83 parts per hundred resin (phr), 13phr, 25phr, respectively, the FKM-KR120/IFR-ZB composites had good synergetic flame resistant effect. TGA data showed that IFR and synergists could obviously lower the maximum weight loss rate of FKM composites and effectively increase the char residue at high temperature. The morphological structures of the composites observed by scanning electron microscopy (SEM) demonstrated that the addition of ZB and KR120 could clearly reduce the cracks in char residue and make the char layer structure more integrated and compact.展开更多
The thermal protective performance (TPP) is important for heat and flame resistant fabrics. In this study, fabrics which are made of flame resistant cotton, Nomex, polybenzimidazole (PBI), polysulfonamide (PSA), kerme...The thermal protective performance (TPP) is important for heat and flame resistant fabrics. In this study, fabrics which are made of flame resistant cotton, Nomex, polybenzimidazole (PBI), polysulfonamide (PSA), kermel, and blend of kermel with rayon fiber are investigated on high intensity of different radiant and convective heat source. The mechanism of heat transfer in different situations is discussed. It is identified that exposed condition has an important effect on thermal protective performance. TPP rating increases with the increasing percentage of convective heat.展开更多
An improved numerical heat transfer model considering pyrolysis effect is proposed to predict thermal performance of heat-resistant fabric subjected to radiant heat flux. The model incorporates the heat-induced change...An improved numerical heat transfer model considering pyrolysis effect is proposed to predict thermal performance of heat-resistant fabric subjected to radiant heat flux. The model incorporates the heat-induced changes in fabric thermophysical properties. The new model has been validated with data from modified Radiant Protective Performance (RPP) tests of flame-resistant cotton fabrics. Comparison with experimental data shows that the predictions of mass loss rates and temperature profiles within the charring material and skin simulant are in reasonably good agreement with the experiments. Results from the numerical model contribute to a better understanding of the heat transfer process within flame-resistant fabrics under high heat flux conditions, and also to establish a systematic method for analyzing heat transfer in other fibrous materials applications.展开更多
文摘Flame Thermal Spray (FTS) coatings frequently show some porosity and reduced adherence to substrate, which affect its properties, especially its corrosion resistance. In this work, the corrosion resistance of AISI 1018 carbon steel coated by different methods is compared: electroless nickel (EN) coating, NiCrFeBSi obtained by FTS, duplex coatings of an EN deposit on a layer of NiCrFeBSi obtained by FTS and a layer of NiCrFeBSi on an EN deposit. The coatings were characterized using optical microscopy and scanning electron microscopy techniques, EDS microprobe microanalysis, roughness as well as electrochemical polarization tests to obtain the corrosion rate. The results show the enhancement in the corrosion resistance in saline medium of the duplex coatings, especially of the EN coating on FTS layer.
文摘This study was to develop the flame retardant (FR) protective clothing which had multifunction such anti-bacterial, UV cut, FR function with water repellent and water vapor permeable laminating textiles for industrial workers. First of all, the FR yarn and FR textiles were developed for this purpose. Second, the comparison analysis between the halogen laminating textiles and halogen-free laminating textiles were tested to figure out the eco-friendly laminating method. Third, the flame retardant ability was compared the halogen laminated textiles to halogen-free laminated textiles. LOI, UV protection ratio, antibiosis after 50 laundry test, water proof pressure, and moisture permeability of developed textiles were tested. GC-HR-TOF-MS was used for analysis of laminating film (halogen and halogen-free). 4.1 wt% TiO2 yarn showed antibacterial function (Pneumococcus & Staphylococcus aureus: 99.9%), UV Protection (UVA: 90.8, UVB: 92.1), and LOI (33.6). The chosen optimal compounding ratio for PU compound of HRF and HFFR were as followed: PU resin 58.3%, DMF (Dimethyl formamide, δ = 12.2) 8.3%, MEK (Methylethylketone) 8.3% and FR (flame retardants) 25.0%. Binder for laminating should not be included over 10% of FRs because of adhesion between textiles and FR laminating film. There were detected phosphorus compounds in the textiles treated by halogenated type flame retardants and halogenated-free type flame retardants. There were not any detected harmful compounds from all textile samples.
文摘The fibred magnesium hydroxide from the bracite was treated with a surface active agent. The modified fibred magnesium hydroxide as flame-retardant, boric acid, barium stearate, polydimethyl siloxane fluid, vinyltriethoxysilane as synergists of the flame-retardant were added to polyene resin. The flame-resistance polyene material prepared meets the requirements of EWCZ-6287-1. (Author abstract) 2 Refs.
文摘Organic dust flames deal with a field of science in which many complicated phenomena like pyrolysis or devolatization of solid particles and combustion of volatile particles take place. One-dimensional flame propagation in cloud of fuel mixture is analyzed in which flame structure is divided into three zones. The first zone is preheat zone in which rate of the chemical reaction is small and transfer phenomena play significant role in temperature and mass distributions. In this model, it is assumed that particles pyrolyze first to yield a gaseous fuel mixture. The second zone is reaction zone where convection and vaporization rates of the particles are small. The third zone is convection zone where diffusive terms are negligible in comparison of other terms. Non-zero Biot number is used in order to study effect of particles thermal resistance on flame characteristics. Also, effect of particle size on combustion of micro organic dust is investigated. According to obtained results, it is understood that both flame temperature and burning velocity decrease with rise in the Biot number and particle size.
基金Supported by the National Key Technology R & D Program (2006BAE03B05-2)
文摘The efficiency of different intumescent flame-retardant (IFR) formulations designed to improve the flame resistance of fluoroelastomer ( FKM ) composites was studied. The proportion of ammonium polyphosphate (APP) with charring-foaming agent (CFA) in IFR systems, and the addi- tion of synergists zinc borate (ZB) and ketonealdehyde resin ( KR120 ) were investigated to show their effect on flame resistance of FKM. According to flame resistance tests, when the mass ratio of APP to CFA was 4:1 as well as the loadings of IFR, ZB, KR120 were 83 parts per hundred resin (phr), 13phr, 25phr, respectively, the FKM-KR120/IFR-ZB composites had good synergetic flame resistant effect. TGA data showed that IFR and synergists could obviously lower the maximum weight loss rate of FKM composites and effectively increase the char residue at high temperature. The morphological structures of the composites observed by scanning electron microscopy (SEM) demonstrated that the addition of ZB and KR120 could clearly reduce the cracks in char residue and make the char layer structure more integrated and compact.
文摘The thermal protective performance (TPP) is important for heat and flame resistant fabrics. In this study, fabrics which are made of flame resistant cotton, Nomex, polybenzimidazole (PBI), polysulfonamide (PSA), kermel, and blend of kermel with rayon fiber are investigated on high intensity of different radiant and convective heat source. The mechanism of heat transfer in different situations is discussed. It is identified that exposed condition has an important effect on thermal protective performance. TPP rating increases with the increasing percentage of convective heat.
文摘An improved numerical heat transfer model considering pyrolysis effect is proposed to predict thermal performance of heat-resistant fabric subjected to radiant heat flux. The model incorporates the heat-induced changes in fabric thermophysical properties. The new model has been validated with data from modified Radiant Protective Performance (RPP) tests of flame-resistant cotton fabrics. Comparison with experimental data shows that the predictions of mass loss rates and temperature profiles within the charring material and skin simulant are in reasonably good agreement with the experiments. Results from the numerical model contribute to a better understanding of the heat transfer process within flame-resistant fabrics under high heat flux conditions, and also to establish a systematic method for analyzing heat transfer in other fibrous materials applications.
基金supported by the National Key Research and Development Program of China(No.2021YFB3501002)the National Science and Technology Major Project of China(No.J2019-Ⅷ-0003-0165)Qinghai Salt Lake Industry Co.,Ltd.financially by the Science and Technology Project,China(No.21-ZC0609-0003)。