A learning algorithm based on a hard limiter for feedforward neural networks (NN) is presented,and is applied in solving classification problems on separable convex sets and disjoint sets.It has been proved that the a...A learning algorithm based on a hard limiter for feedforward neural networks (NN) is presented,and is applied in solving classification problems on separable convex sets and disjoint sets.It has been proved that the algorithm has stronger classification ability than that of the back propagation (BP) algorithm for the feedforward NN using sigmoid function by simulation.What is more,the models can be implemented with lower cost hardware than that of the BP NN.LEARNIN展开更多
In recent years, sub-synchronous oscillation accidents caused by wind power integration have received extensive attention. The recorded constant-amplitude waveforms can be induced by either linear or nonlinear oscilla...In recent years, sub-synchronous oscillation accidents caused by wind power integration have received extensive attention. The recorded constant-amplitude waveforms can be induced by either linear or nonlinear oscillation mechanisms. Hence, the nonlinear behavior needs to be distinguished prior to choosing the analysis method. Since the 1960s, the higher-order statistics(HOS) theory has become a powerful tool for the detection of nonlinear behavior(DNB) in production quality control wherein it has mainly been applied to mechanical condition monitoring and fault diagnosis. This study focuses on the hard limiters of the voltage source converter(VSC) control systems in the wind farms and attempts to detect the nonlinear behavior caused by bi-or uni-lateral saturation hard limiting using the HOS analysis. First, the conventional describing function is extended to obtain the detailed frequency domain information on the bi-and uni-lateral saturation hard limiting. Furthermore, the bi-and tri-spectra are introduced as the HOS, which are extended into bi-and tri-coherence spectra to eliminate the effects of the linear parts on the harmonic characteristics of hard limiting in the VSC control system, respectively. The effectiveness of the HOS in the DNB and the classification of the hard-limiting types is proven, and its detailed derivation and estimation procedure is presented. Finally, the quadratic and cubic phase coupling in the signals is illustrated, and the performance of the proposed method is evaluated and discussed.展开更多
A new performance analysis method of Optical Code Division Multiple Access ( OCDMA ) systems with an optical hard limiter is studied. The bit error probability of the OCDMA system is derived, and the numerical ...A new performance analysis method of Optical Code Division Multiple Access ( OCDMA ) systems with an optical hard limiter is studied. The bit error probability of the OCDMA system is derived, and the numerical results of the system with and without an ideal optical hard limiter are analyzed respectively. The results show that although the derived expression is different from the one derived by J A Salehi , the numerical results are the same as those analyzed by J A Salehi, and the numerical result can be easily achieved in this expression.展开更多
文摘A learning algorithm based on a hard limiter for feedforward neural networks (NN) is presented,and is applied in solving classification problems on separable convex sets and disjoint sets.It has been proved that the algorithm has stronger classification ability than that of the back propagation (BP) algorithm for the feedforward NN using sigmoid function by simulation.What is more,the models can be implemented with lower cost hardware than that of the BP NN.LEARNIN
基金supported by the State Grid Guide Project(No.5108-202218030A-1-1-ZN)。
文摘In recent years, sub-synchronous oscillation accidents caused by wind power integration have received extensive attention. The recorded constant-amplitude waveforms can be induced by either linear or nonlinear oscillation mechanisms. Hence, the nonlinear behavior needs to be distinguished prior to choosing the analysis method. Since the 1960s, the higher-order statistics(HOS) theory has become a powerful tool for the detection of nonlinear behavior(DNB) in production quality control wherein it has mainly been applied to mechanical condition monitoring and fault diagnosis. This study focuses on the hard limiters of the voltage source converter(VSC) control systems in the wind farms and attempts to detect the nonlinear behavior caused by bi-or uni-lateral saturation hard limiting using the HOS analysis. First, the conventional describing function is extended to obtain the detailed frequency domain information on the bi-and uni-lateral saturation hard limiting. Furthermore, the bi-and tri-spectra are introduced as the HOS, which are extended into bi-and tri-coherence spectra to eliminate the effects of the linear parts on the harmonic characteristics of hard limiting in the VSC control system, respectively. The effectiveness of the HOS in the DNB and the classification of the hard-limiting types is proven, and its detailed derivation and estimation procedure is presented. Finally, the quadratic and cubic phase coupling in the signals is illustrated, and the performance of the proposed method is evaluated and discussed.
文摘A new performance analysis method of Optical Code Division Multiple Access ( OCDMA ) systems with an optical hard limiter is studied. The bit error probability of the OCDMA system is derived, and the numerical results of the system with and without an ideal optical hard limiter are analyzed respectively. The results show that although the derived expression is different from the one derived by J A Salehi , the numerical results are the same as those analyzed by J A Salehi, and the numerical result can be easily achieved in this expression.