According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th...According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize.展开更多
The source reactive-current compensation is crucial in energy transmission efficiency. The compensator design in frequency-domain was already widely discussed and examined. This paper presents results of a study on ho...The source reactive-current compensation is crucial in energy transmission efficiency. The compensator design in frequency-domain was already widely discussed and examined. This paper presents results of a study on how to design reactive compensators in time-domain. It’s the first time the reactive compensator have been designed in time domain. The example of compensator design was presented.展开更多
该文提出了一种电力基波频率和相位的高精度数字化实时检测方法,提出了基于高精度基波相频实时检测的有源电力滤波器谐波和无功电流的检测方法。相位检测是基于三角函数正交性及自适应滤波的原理构造了相位跟踪的闭环控制回路,结合延时...该文提出了一种电力基波频率和相位的高精度数字化实时检测方法,提出了基于高精度基波相频实时检测的有源电力滤波器谐波和无功电流的检测方法。相位检测是基于三角函数正交性及自适应滤波的原理构造了相位跟踪的闭环控制回路,结合延时反馈及变参数 PI 控制技术,使初相跟踪检测的精度达到(10-4)o^(10-10)o的数量级;基波频率的测量是基于初相跟踪检测控制系统的基础之上,求取稳态时初相修正量的时间变化率,即可作为频率跟踪的反馈。在有源电力滤波器中,利用该方法可以求取电压和电流的基波相位频率和相应基波的单位正弦函数,基波幅值用滑窗傅立叶变换的方法求得,从而方便精确地检测出有功和谐波电流。仿真与实验结果证明了所提方法的正确性和有效性。展开更多
文摘According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize.
文摘The source reactive-current compensation is crucial in energy transmission efficiency. The compensator design in frequency-domain was already widely discussed and examined. This paper presents results of a study on how to design reactive compensators in time-domain. It’s the first time the reactive compensator have been designed in time domain. The example of compensator design was presented.
文摘该文提出了一种电力基波频率和相位的高精度数字化实时检测方法,提出了基于高精度基波相频实时检测的有源电力滤波器谐波和无功电流的检测方法。相位检测是基于三角函数正交性及自适应滤波的原理构造了相位跟踪的闭环控制回路,结合延时反馈及变参数 PI 控制技术,使初相跟踪检测的精度达到(10-4)o^(10-10)o的数量级;基波频率的测量是基于初相跟踪检测控制系统的基础之上,求取稳态时初相修正量的时间变化率,即可作为频率跟踪的反馈。在有源电力滤波器中,利用该方法可以求取电压和电流的基波相位频率和相应基波的单位正弦函数,基波幅值用滑窗傅立叶变换的方法求得,从而方便精确地检测出有功和谐波电流。仿真与实验结果证明了所提方法的正确性和有效性。