The equivalent impedance parameters of loads have been widely used to identify and locate the harmonic sources.However,the existing calculation methods suffer from outliers caused by the zero-crossing of the denominat...The equivalent impedance parameters of loads have been widely used to identify and locate the harmonic sources.However,the existing calculation methods suffer from outliers caused by the zero-crossing of the denominator.These outliers can result in inaccuracy and unreliability of harmonic source location.To address this issue,this paper proposes an innovative method of equivalent impedance parameter calculation of three-phase symmetrical loads that avoid outliers.The correctness and effectiveness of the proposed method are verified by simulations on Simulink using actual monitoring data.The results show that the proposed method is not only simple and easy to implement but also highly accurate.展开更多
In the nonlinearity parameter B/A tomography using the second harmonic wav, it is very important to analyze the ultrasonic field of the transducer, especially the generation of the second harmonic wave in the near...In the nonlinearity parameter B/A tomography using the second harmonic wav, it is very important to analyze the ultrasonic field of the transducer, especially the generation of the second harmonic wave in the nearfield. In this paper, the theoretical study and experimental measurements of the second harmoinc pressure field from a circular piston source are performed.And the effect on the nonlinearity parameter tomograaphy is discussed. The results will be used to decrease the error of reconstruction in nonlinearity parameter tomography and bring the ultrasoinc diagnosis a step forward展开更多
基金supported by the National Natural Science Foundation of China(No.51777035).
文摘The equivalent impedance parameters of loads have been widely used to identify and locate the harmonic sources.However,the existing calculation methods suffer from outliers caused by the zero-crossing of the denominator.These outliers can result in inaccuracy and unreliability of harmonic source location.To address this issue,this paper proposes an innovative method of equivalent impedance parameter calculation of three-phase symmetrical loads that avoid outliers.The correctness and effectiveness of the proposed method are verified by simulations on Simulink using actual monitoring data.The results show that the proposed method is not only simple and easy to implement but also highly accurate.
文摘In the nonlinearity parameter B/A tomography using the second harmonic wav, it is very important to analyze the ultrasonic field of the transducer, especially the generation of the second harmonic wave in the nearfield. In this paper, the theoretical study and experimental measurements of the second harmoinc pressure field from a circular piston source are performed.And the effect on the nonlinearity parameter tomograaphy is discussed. The results will be used to decrease the error of reconstruction in nonlinearity parameter tomography and bring the ultrasoinc diagnosis a step forward