期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Higher order harmonics suppression in extreme ultraviolet and soft x-ray
1
作者 陈勇 魏来 +6 位作者 钱凤 杨祖华 王少义 巫殷忠 张强强 范全平 曹磊峰 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第2期344-348,共5页
The extreme ultraviolet and soft x-ray sources are widely used in various domains. Suppressing higher order harmonics and improving spectral purity are significant. This paper describes a novel method of higher order ... The extreme ultraviolet and soft x-ray sources are widely used in various domains. Suppressing higher order harmonics and improving spectral purity are significant. This paper describes a novel method of higher order harmonics suppression with single order diffraction gratings in extreme ultraviolet and soft x-ray. The principle of harmonic suppression with single order diffraction grating is described, and an extreme ultraviolet and soft x-ray non-harmonics grating monochromator is designed based on the single order diffraction grating. The performance is simulated by an optical design software. The emergent beams of a monochromator with different gratings are measured by a transmission grating spectrometer. The results show that the single order diffraction grating can suppress higher order harmonics effectively, and it is expected to be widely used in synchrotron radiation, diagnostics of laser induced plasma, and astrophysics. 展开更多
关键词 higher order harmonics suppression extreme ultraviolet and soft x-ray monochromator single order diffraction grating
下载PDF
MINIATURIZED MICROSTRIP BRANCH-LINE COUPLER WITH GOOD HARMONIC SUPPRESSION PERFORMANCE 被引量:2
2
作者 Yang Guo Li Bo +1 位作者 Kang Wei Ge Sheng 《Journal of Electronics(China)》 2012年第1期132-136,共5页
This paper presents a miniaturized microstrip branch-line coupler with good harmonic suppression performance. The proposed coupler consists of four branch-line sections, each of which is loaded by open-circuit stubs b... This paper presents a miniaturized microstrip branch-line coupler with good harmonic suppression performance. The proposed coupler consists of four branch-line sections, each of which is loaded by open-circuit stubs both at the center and the two ends. This type of loading can realize size reduction and harmonic suppression. As an example, a proposed branch-line coupler operating at 1.0 GHz is designed, fabricated and measured. The results show that the proposed branch-line coupler occupies 67% size of a conventional one and has better than 20 dB suppression from 1.9 to 5.8 GHz. Furthermore, the high slop of the transition band ensures good selectivity of the coupler. 展开更多
关键词 Branch-line coupler MINIATURIZATION Harmonic suppression
下载PDF
Reactive Power Compensation and Harmonic Suppression for Power Supply System of HT-7U Superconductive Tokamak 被引量:1
3
作者 陶骏 刘正之 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第1期629-635,共7页
In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design... In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load. 展开更多
关键词 In Reactive Power Compensation and Harmonic suppression for Power Supply System of HT-7U Superconductive Tokamak APF HT
下载PDF
Costless-Function Model Predictive Current Control of Seven-Phase PMSM to Improve Dynamic Performance and Suppress Harmonics of Marine Electric Propulsion System
4
作者 Xin Li Wei Xie Xiaoyan Xu 《Journal of Mechanics Engineering and Automation》 2020年第6期170-180,共11页
In order to improve the dynamic performance and suppress current harmonic for seven-phase PMSM(permanent magnet synchronous motor),this paper proposed an MPCC(mode predict current control)scheme based on SVPWM(space v... In order to improve the dynamic performance and suppress current harmonic for seven-phase PMSM(permanent magnet synchronous motor),this paper proposed an MPCC(mode predict current control)scheme based on SVPWM(space vector pulse width modulation)technique.By this scheme,the 14 virtual voltage vectors are first calculated based on the principle:the voltage vector synthesized in the 3rd harmonic subspace and the 5th harmonic subspace should be zero,in each sampling period,the optimal voltage vector is directly selected from the 14 virtual voltage vectors to achieve the best output current performance of seven-phase PMSM.In addition,no cost function related calculations are required in the MPCC scheme,reducing the calculation time and improving the dynamic response of the system.The simulation model of the seven-phase PMSM vector control system is established by using the Simulink tool of MATLAB,and the effectiveness of the scheme will be presented. 展开更多
关键词 Optimal voltage vector seven-phase PMSM MPCC SVPWM harmonic suppress
下载PDF
A Designated Harmonic Suppression Technology for Sampled SPWM
5
作者 杨平 《Journal of Electronic Science and Technology of China》 2005年第3期253-255,共3页
Sampled SPWM is an excellent VVVF method of motor speed control, meanwhile the harmonic components of the output wave impairs its applications in practice. A designated harmonic suppression technology is presented for... Sampled SPWM is an excellent VVVF method of motor speed control, meanwhile the harmonic components of the output wave impairs its applications in practice. A designated harmonic suppression technology is presented for sampled SPWM, which is an improved algorithm for the harmonic suppression in high voltage and high frequency spectrum. As the technology is applied in whole speed adjusting range, the voltage can be conveniently controlled and high frequency harmonic of SP WM is also improved. 展开更多
关键词 sampled SPWM variable voltage and variable frequency speed control harmonic suppression improved algorithm
下载PDF
Vibration harmonic suppression technology for electromagnetic vibrators based on an improved sensorless feedback control method
6
作者 Wei LI Junning CUI +1 位作者 Xingyuan BIAN Limin ZOU 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2024年第3期472-483,共12页
To realize low harmonic distortion of the vibration waveform output from electromagnetic vibrators,we propose a vibration harmonic suppression technology based on an improved sensorless feedback control method.Without... To realize low harmonic distortion of the vibration waveform output from electromagnetic vibrators,we propose a vibration harmonic suppression technology based on an improved sensorless feedback control method.Without changing the original driving circuit,the alternating current(AC)equivalent resistance of the driving coil is used to obtain high-precision vibration velocity information,and then a simple and reliable velocity feedback control system is established.Through the study of the effect of different values of key parameters on the system,we have achieved an effective expansion of the velocity characteristic frequency band of low-frequency vibration,resulting in an enhanced harmonic suppression capability of velocity feedback control.We present extensive experiments to prove the effectiveness of the proposed method and make comparisons with conventional control methods.In the frequency range of 0.01-1.00 Hz,without using any sensors,the method proposed in this study can reduce the harmonic distortion of the vibration waveform by about 40%compared to open-loop control and by about 20%compared to a conventional sensorless feedback control method. 展开更多
关键词 Vibration calibration Electromagnetic vibrators Harmonic suppression Sensorless control method Velocity feedback control
原文传递
Current Loop Disturbance Suppression for Dual Three Phase Permanent Magnet Synchronous Generators Based on Modified Linear Active Disturbance Rejection Control
7
作者 Dezhi Xu Hu Yao +1 位作者 Yang He Wenxiang Zhao 《Chinese Journal of Electrical Engineering》 EI CSCD 2024年第1期101-113,共13页
A modified four-dimensional linear active disturbance rejection control(LADRC)strategy is proposed for a dual three-phase permanent magnet synchronous generator(DTP-PMSG)system to reduce cross-coupling between the d a... A modified four-dimensional linear active disturbance rejection control(LADRC)strategy is proposed for a dual three-phase permanent magnet synchronous generator(DTP-PMSG)system to reduce cross-coupling between the d and q axis currents in the d-q subspace and harmonic currents in the x-y subspace.In the d-q subspace,the proposed strategy uses a model-based LADRC to enhance the decoupling effect between the d and q axes and the disturbance rejection ability against parameter variation.In the x-y subspace,the 5th and 7th harmonic current suppression abilities are improved by using quasi-resonant units parallel to the extended state observer of the traditional LADRC.The proposed modified LADRC strategy improved both the steady-state performance and dynamic response of the DTP-PMSG system.The experimental results demonstrate that the proposed strategy is both feasible and effective. 展开更多
关键词 Dual three-phase permanent magnet synchronous generator current loop decoupling control harmonic suppression linear active disturbance rejection control
原文传递
Research of Magnetic Bias Control System Based on STATCOM 被引量:1
8
作者 Zongqiang Zheng 《World Journal of Engineering and Technology》 2016年第3期9-15,共7页
As the most important style of reactive power compensation system, the research and design control system of static synchronous compensator (STATCOM) is an important aspect of keeping stable and normal operation. This... As the most important style of reactive power compensation system, the research and design control system of static synchronous compensator (STATCOM) is an important aspect of keeping stable and normal operation. This paper analyzes the influences of bias magnetic to STATCOM, and proposes an effective magnetic bias control method and program realization, so reduced to producing two harmonics. It improves the quality and reliability of STATCOM output voltage;Finally, the tests are conducted in the ±500 kVar STATCOM, and the results show the validity and necessity of this compensation method. 展开更多
关键词 Static Synchronous Compensator (STATCOM) Magnetic Bias Control Harmonic suppression
下载PDF
An Improved Repetitive Control Strategy for LCL Grid-Connected Inverter
9
作者 Ning He Chenlu Song +1 位作者 Feng Gao Cheng Qian 《Journal of Beijing Institute of Technology》 EI CAS 2022年第4期391-400,共10页
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of... This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved. 展开更多
关键词 GRID-CONNECTED inverter LCL filter harmonic suppression repetitive control
下载PDF
Design of broadband class-F power amplifier with high-order harmonic suppression for S-band application 被引量:2
10
作者 林俊明 章国豪 +3 位作者 郑耀华 李思臻 张志浩 陈思弟 《Journal of Semiconductors》 EI CAS CSCD 2015年第12期119-123,共5页
A broadband class-F power amplifier for an S-band handset device is integrated on a 330.82 mm^3 die using an In Ga /GaAs HBT process. With LC serial harmonic traps immersed into the broadband output matching circuit, ... A broadband class-F power amplifier for an S-band handset device is integrated on a 330.82 mm^3 die using an In Ga /GaAs HBT process. With LC serial harmonic traps immersed into the broadband output matching circuit, good harmonic suppression performance can be achieved. A pure resistive impedance of the matching circuit, but near zero at second and infinite at third harmonic frequency, which enhances the efficiency, is obtained across 1.8–2.5 GHz. Tested with a continuous wave(CW) signal, the PA delivers an output power of 34 dBm and achieves a PAE of 57% at 2 GHz. In addition, excellent harmonic suppression levels of less than –53 dBc across the second to fifth harmonic are obtained. 展开更多
关键词 S-BAND power amplifier BROADBAND class-F harmonic suppression InGaP/GaAs HBT
原文传递
A conducted emission mitigation method for software-defined radios through vector signal cancellation
11
作者 Siyu XIA Qi WU 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第9期289-298,共10页
Recently,Software-Defined Radio(SDR)has gained great popularity owing to its attractive merits,such as flexible signals configuration in multiple channels.However,commercial SDR equipment also has large spurious emiss... Recently,Software-Defined Radio(SDR)has gained great popularity owing to its attractive merits,such as flexible signals configuration in multiple channels.However,commercial SDR equipment also has large spurious emissions in the Transmitting(Tx)channel.This paper presents a cascaded model for the Conducted Emission(CE)properties of a general SDR platform,which captures all the key components with high precision.Based on a deeper understanding of the CE properties,a mitigation method is proposed for suppressing the spurious emissions of an SDR Tx channel.This method is based on an efficient vector signal cancellation scheme,in which multiple SDR channels are adopted to suppress the second-and third-order harmonic signals simultaneously.A hardware prototype with dual SDR channels is built and measured for verification.Experimental results show that the suppression level of the third-order harmonic signal is 24 dB on average in the frequency range of 100 MHz to 3000 MHz.The theoretic limit of the suppression level is related to the magnitude and phase errors,and the suppression level may be further improved by calibrating each SDR channel. 展开更多
关键词 CANCELLATION Conducted Emission(CE) Harmonic suppression SDR Spurious emission
原文传递
Technological Research on Navigation System Interfered by Harmonic Wave
12
作者 CUI Hao-yuan SONG Meng-ning 《International Journal of Plant Engineering and Management》 2015年第2期91-98,共8页
Electromagnet interference troubles are more and more and complex with each pass day along with improvement of large system electronization. This article will analyze the interference problems caused by harmonic waves... Electromagnet interference troubles are more and more and complex with each pass day along with improvement of large system electronization. This article will analyze the interference problems caused by harmonic waves in large system. The generation,characteristic and perniciousness of harmonic waves will be qualitatively analyzed for summarizing practical experience to provide mentality and method for settling the large system electromagnet interference trouble. This article raises the approach and method of harmonic suppression from the root of harmonic generation during ultrashort wave transmission and through actual test and analyzing verification. The effectivity and correctness of the methods adopted are certified by theoretical analysis and experimental verification. 展开更多
关键词 harmonic interference harmonic suppression trap rejection filtering
原文传递
上一页 1 下一页 到第