Heat flow balance and control strategies for a large GSHP
1
作者 陈义波 陈九法 +2 位作者 Umberto Berardi 乔未来 陈军伟 《Journal of Southeast University(English Edition)》 EI CAS 2013年第1期92-98,共7页
The possibility of underground imbalance between heat emission and absorption has a negative impact on the performance of ground-source heat pump systems (GSHPs). Numerical and experimental researches were made in a... The possibility of underground imbalance between heat emission and absorption has a negative impact on the performance of ground-source heat pump systems (GSHPs). Numerical and experimental researches were made in a residential building, which is supplied with a GSHP system and a ceiling radiation system combined with a replacement fresh air system. EnergyPlus simulations were used to estimate heating and cooling loads, and to assess the heat generated from the water pump, the fan and the heat pump unit. Then, Fluent simulations were used to compare three different control strategies of handling the underground heat exchange. These simulations were strongly based on an experimentally verified model. It is obtained that a ratio between cooling and heating loads is 5.08 : 1 in a case study in Nanjing. Moreover, the control strategy based on the starting time is more efficient and reliable than the temperature and temperature difference strategies to control the underground heat exchange. 展开更多
关键词 ground-source heat pump system residential building heat balance control strategy
下载PDF
FREEZE PROFILE AND HEAT BALANCE CALCULATION OF THE 160kA DRAINED CELL 被引量:5
2
作者 X.P. Li J. Li +2 位作者 Y.Q. Lai H.Q.Zhao Y.X.Liu School of Metallurgical Science and Engineering, Central South University, Changsha 410083, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2004年第2期215-220,共6页
A 2D full cell thermo-electric model of 160kA drained cell was set up using finiteelement code to calculate its freeze profile, then the drained cell model was modifiedaccording to the freeze profile computed and its ... A 2D full cell thermo-electric model of 160kA drained cell was set up using finiteelement code to calculate its freeze profile, then the drained cell model was modifiedaccording to the freeze profile computed and its heat balance was calculated. Comparedwith that of a 160kA conventional Hall-Heroult cell (H-H cell), though the melts vol-ume of the drained cell reduced greatly, the whole heat loss from it didn't drop downapparently, and an analysis was presented in the paper. On the other hand, the anode-cathode distance (ACD) of a drained cell was much less than that of a H-H cell, sothe voltage drop on it and heat produced decreased too, steps should be taken to keepa workable heat balance on a drained cell. 展开更多
关键词 drained cell freeze profile heat balance finite element code
下载PDF
Regulating metal-acid double site balance on mesoporous SiO_(2)-Al_(2)O_(3) composite oxide for supercritical n-decane cracking
3
作者 Liu-Ling Chen Jun Zhang +5 位作者 Chun-Guang Li Li-Qun Fei Bo Wang Chen-Qi Zhang Yi Jiao Jian-Li Wang 《Petroleum Science》 SCIE EI CAS CSCD 2024年第4期2881-2891,共11页
The balance between metal and acid sites directly affects the preparation of high-performance cracking catalysts with high heat sink and low coking.Nevertheless,how to control acid-metal sites balance and its relation... The balance between metal and acid sites directly affects the preparation of high-performance cracking catalysts with high heat sink and low coking.Nevertheless,how to control acid-metal sites balance and its relationship with cracking performance are reported scarcely.In this work,a series of Pt/Al_(2)O_(3)-SiO_(2) dual sites catalysts with different metal to acid active sites ratio(C_(M)/C_(SA))were constructed by ethanolassisted impregnation method and the impact on n-decane cracking under supercritical conditions was systematically and deeply investigated.The results showed that the conversion and carbon deposition increased gradually with varied C_(M)/C_(SA)and reached the balance at C_(M)/C_(SA)of 0.13.The proper ratio C_(M)/C_(SA)(0.13)can balance the deep dehydrogenation coking over metal active sites and high heat sink of cracking over acid active sites,the chemical heat sink reaches amazing 1.75 MJ/kg and carbon deposition is only22.03 mg/cm^(2) at 750℃.Meanwhile,the few metal sites at low C_(M)/C_(SA)and the few strong acid sites at high C_(M)/C_(SA)are the main factors limiting the cracking activity.Low C_(M)/C_(SA)limit the activation of C-H bond and deep dehydrogenation of coking precursor,resulting in relative low cracking activity and carbon deposition,while high C_(M)/C_(SA)limit the activation of C-C bond and increase the deep dehydrogenation.In this contribution,design and construction of metal-acid dual sites can not only provide the technical solution for the preparation of high heat sink and low coking cracking catalyst,but also deepen the understanding of the cracking path of hydrocarbon fuel. 展开更多
关键词 Metal-acid dual sites balance Catalytic cracking Hydrocarbon fuels Chemical heat sink Carbon deposition
下载PDF
Heat balance of solar-soil source heat pump compound system 被引量:2
4
作者 陈金华 包修碧 +1 位作者 彭运林 贾宇 《Journal of Central South University》 SCIE EI CAS 2012年第3期809-815,共7页
Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is fo... Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil. 展开更多
关键词 solar-soil source heat pump compound system heat balance ground-coupled heat pump
下载PDF
Role of heat balance on the microstructure evolution of cold spray coated AZ31B with AA7075 被引量:3
5
作者 Bahareh Marzbanrad Mohammad Hadi Razmpoosh +1 位作者 Ehsan Toyserkani Hamid Jahed 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2021年第4期1467-1478,共12页
A promising solid-state coating mechanism based on the cold spray technique provides highly advantageous conditions on thermal-sensitive magnesium alloys.To study the effect of heat balance in cold spray coating on mi... A promising solid-state coating mechanism based on the cold spray technique provides highly advantageous conditions on thermal-sensitive magnesium alloys.To study the effect of heat balance in cold spray coating on microstructure,experiments were designed to successfully coat AA7075 on AZ31B with two different heat balance conditions to yield a coated sample with tensile residual stress and a sample with compressive residual stress in both coating and substrate.The effects of coating temperature on the microstructure of magnesium alloy and the interfaces of coated samples were then analyzed by SEM,EBSD,TEM in high-and low-heat input coating conditions.The interface of the AA7075 coating and magnesium alloy substrate under both conditions consists of a narrow-band layer with very fine grains,followed by columnar grains of magnesium that have grown perpendicular to the interface.At higher temperatures,this layer became wider.No intermetallic phase was detected at the interface under either condition.It is shown that the microstructure of the substrate was affected by coating temperature,leading to stress relief,dynamic recrystallization and even dynamic grain growth of magnesium under high temperature.Reducing the heat input and increasing the heat transfer decreased microstructural changes in the substrate. 展开更多
关键词 Cold spraying heat balance Microstructural analysis Coating interface Magnesium Alloy AZ31B Residual Stress
下载PDF
Study on the Influence of Piloti on Mean Radiant Temperature in Residential Blocks by 3-D Unsteady State Heat Balance Radiation Calculation 被引量:1
6
作者 Tian-Yu Xi Jian-Hua Ding Hong Jin 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2014年第4期91-95,共5页
Piloti is commonly used in tropical and subtropical climate zones to get high wind velocity and create shadowed areas in order to optimize the living environment of residential blocks,but there are few studies to reve... Piloti is commonly used in tropical and subtropical climate zones to get high wind velocity and create shadowed areas in order to optimize the living environment of residential blocks,but there are few studies to reveal the influence of piloti on the radiant environment of residential blocks systematically. Taking the city of Guangzhou as an example,using 3-D Unsteady State Heat Balance Radiation Calculation Method,this paper shows that the mean radiant temperature( MRT) under piloti area increases with the increase of piloti ratio,and especially when piloti ratio is equal to 100%,the MRT increase trend becomes sharp. The MRT of exposed area decreases with the increase of piloti ratio,especially when piloti ratio reaches 100%,the decrease trend of MRT becomes sharp,which offers the reference for the study on piloti design in subtropical climate zones and further research on living environment by CFD simulation in residential blocks. 展开更多
关键词 piloti mean radiant temperature 3-D unsteady state heat balance radiation calculation residential block
下载PDF
Modeling of the Earth’s Planetary Heat Balance with Electrical Circuit Analogy 被引量:1
7
作者 Habibullo I. Abdussamatov Alexander I. Bogoyavlenskii +1 位作者 Sergey I. Khankov Yevgeniy V. Lapovok 《Journal of Electromagnetic Analysis and Applications》 2010年第3期133-138,共6页
The integral heat model for the system of the Earth’s surface—the atmosphere—the open space based on the electrical circuit analogy is presented. Mathematical models of the heat balance for this system are proposed... The integral heat model for the system of the Earth’s surface—the atmosphere—the open space based on the electrical circuit analogy is presented. Mathematical models of the heat balance for this system are proposed. Heat circuit which is analog of the electrical circuit for investigating the temperature dependencies on the key parameters in the clear form is presented. 展开更多
关键词 Electrical CIRCUIT ANALOGY PLANETARY heat balance CLIMATE TRENDS
下载PDF
The Heat Balance in the Western Equatorial Pacific Warm Pool during the Westerly Wind Bursts: A Case Study
8
作者 刘海龙 张学洪 李薇 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2001年第5期882-896,共15页
The responses of sea surface temperature (SST) in the western equatorial Pacific warm pool to the westerly wind bursts (WWBs) play an important role in the relationship between WWB and ENSO. By using data collected fr... The responses of sea surface temperature (SST) in the western equatorial Pacific warm pool to the westerly wind bursts (WWBs) play an important role in the relationship between WWB and ENSO. By using data collected from eight buoys of TOGA (Tropical Ocean-Global Atmosphere)- COARE (Coupled Ocean-Atmosphere Response Experiment), the heat balances of the upper ocean in the western equatorial Pacific around 0 degrees, 156 degreesE during two WWB events were calculated according to Stevenson and Niiler's (1983) method. In both events, SST increased before and after the WWBs, while decreased within the WWBs. The SST amplitudes approximated to 1 degreesC. Although sometimes the horizontal heat advections may become the biggest term in the heat balance, the variation of SST was dominated by the surface heat flux. On the other aspect, some different features of the two events are also revealed. The two cases have different variation of mixed layer depth. The depth of mixed layer is almost double in the first case (35 in to 70 m), which is caused by Ekman convergence, while only 10m increments due to entrainment in the second one, There are also differences in the currents structure. The different variations of thermal and currents structure in the mixing layers accounted for the different variation of the heat balance during the two events, especially the advection and residue terms. The seasonal variation of SST in this area is also investigated simply. The first WWB event happened just during the seasonal transition. So we considered that it is a normal season transition rather than a so-called anomaly. That also suggested that the seasonal distinction of the WWB is worthy of more attention in the researches of its relationship to ENSO. 展开更多
关键词 westerly wind burst the western equatorial Pacific warm pool heat balance
下载PDF
Heat balance simulation of drained aluminum reduction cell 被引量:2
9
作者 刘业翔 李相鹏 +3 位作者 赖延清 李劼 周向阳 赵恒勤 《中国有色金属学会会刊:英文版》 CSCD 2003年第5期1199-1202,共4页
Compared with a conventional Hall Heroult cell(H H cell), the interpolar distance of a drained cell can be reduced significantly and the cell voltage and heat produced in the electrolysis will decrease greatly as well... Compared with a conventional Hall Heroult cell(H H cell), the interpolar distance of a drained cell can be reduced significantly and the cell voltage and heat produced in the electrolysis will decrease greatly as well, which makes it crucial to achieve a new heat balance in the drained cell. A half anode cathode slice model of a hypothetical drained cell retrofitted from a 160 kA currently used in H H cell was developed for the thermo electric calculation and simulation. The results were presented and analyzed and possible approaches for setting up a new heat balance in a drained cell were discussed. 展开更多
关键词 热平衡 消耗电池 热电计算 仿真
下载PDF
Parallel Correlative Study of the Heat Balance Test Process for Testing the Efficiency of Turbo-Generators
10
作者 Luqman Muhammed Audu Olugbenga Olanrewaju Noah +1 位作者 Ogaga Kenneth Ajaino Friday Chukwuyem Igbesi 《Energy and Power Engineering》 2016年第3期161-172,共12页
In order to prolong the life span of a turbo-generator plant and sustain its performance at high efficiency, it is subjected periodically to regular test to monitor the operational profile and efficiency of power conv... In order to prolong the life span of a turbo-generator plant and sustain its performance at high efficiency, it is subjected periodically to regular test to monitor the operational profile and efficiency of power conversion from mechanical energy to electrical energy. Analysis of these test data serves as a measure to indicate deviation from normal operation profile and deterioration of plant performance. This present work implemented the heat balance tests process to three turb- generator units in order to assess the harmony, consistency, and accuracy of results to establish parallel correlation for the test process. The test process involves carrying out a heat balance for the turbo-generators at 50%, 75% and 100% load respectively through the determination of the heat losses through the hydrogen coolers, bearing oil, seal oil and radiation and convention to the atmosphere. Some important results were presented in the paper. 展开更多
关键词 EFFICIENCY TURBO-GENERATOR TESTING Hydrogen-Cooled heat balance
下载PDF
The heat balance on the sea surface in the mature phase of 1982/83 El Nino event
11
作者 Yang Dasheng, Yang Bai and Pan Zhi Department of Geophysics, Peking University, Beijing 100871, China 《Acta Oceanologica Sinica》 SCIE CAS CSCD 1991年第4期539-554,共16页
Using the air-sea data set of January, 1983 (the mature phase of the 1982/83 El Nino event), the net radiation on the sea surface, the fluxes of the latent and the sensible heat from ocean to the atmosphere and the ne... Using the air-sea data set of January, 1983 (the mature phase of the 1982/83 El Nino event), the net radiation on the sea surface, the fluxes of the latent and the sensible heat from ocean to the atmosphere and the net heat gain of the sea surface are calculated over the Indian and the Pacific Oceans for the domain of 35°N-35°S and 45°E-75°W. The results indicate that the upward transfer of the latent and the sensible heat fluxes over the winter hemisphere is larger than that over the summer hemisphere. The sensible heat over the tropical mid Pacific in the Southern Hemisphere is transported from the atmosphere to the ocean, though its magnitude is rather small. The latent heat flux gained by the air over the eastern Pacific is less than the mean value of the normal year. The net radiation, on which the cloud amount has considerable impact, is essentially zonally distributed. Moreover, the sea surface temperature (SST) has a very good correlation with the net radiation, the region of warm SST coinciding with that of the low net radiation. The net radiation obtained by the mid Pacific Ocean is reduced by the SST anomaly during the El Nino event, whereas the atmosphere over there get more latent heat flux, and this results in the diminution of the net heat gain of the ocean. The overview of the heat budget is that the ocean over the winter hemisphere is the energy source of the atmosphere, and that over the summer hemisphere its energy sink. 展开更多
关键词 heat The heat balance on the sea surface in the mature phase of 1982/83 El Nino event Nino EL
下载PDF
Conflict between Population and Urbanization Factors: Impact of Urban Heat Island on Energy Consumption Balance
12
作者 Parisa Shahmohamadi Che-Ani A. I. +2 位作者 Iraj Etessan Khairul Nizam Abdul Maulud M. F. I. Mohd-Nor 《Journal of Civil Engineering and Architecture》 2010年第10期16-23,共8页
High density of buildings and population in urban areas increases urban temperature, generally known as the urban heat island. Raised temperature, especially in SUlIuner, alms city centers into unwelcome hot areas, wi... High density of buildings and population in urban areas increases urban temperature, generally known as the urban heat island. Raised temperature, especially in SUlIuner, alms city centers into unwelcome hot areas, with direct effects on electricity demand and energy consttrnption for cooling buildings and increases the production of carbon dioxide and other pollutants. Therefore, by considering that the energy consumption in the world has been faced with intense crisis, it becomes increasingly important to study the effects of urban heat island on energy constunption in order to improve people's environment and decrease energy use in cities. This paper, therefore, is focused on urbanization and population size factors to understand tile influence way of these factors on formation of UHI and energy consumption balance. To achieve this aim, this paper explores literally the conceptual framework of confliction between population and urban structure, which produce UHI intensity and affected energy consumption balance. It is then discussed how these two factors can be affected and give implication to the city, and then, focuses on whether actions should be taken for balancing adaptation and mitigation UHI effects. It will be concluded by making the recommendations for preventive action and provide quality of life. 展开更多
关键词 Energy consumption balance urban construction urban heat island ttrban population.
下载PDF
Application of Energy Balance Snowmelt Model on Sunny Slope in Western Tianshan Mountains 被引量:1
13
作者 熊良时 林楚娟 徐俊荣 《Agricultural Science & Technology》 CAS 2012年第4期872-876,共5页
[Objective] The study aimed to apply energy balance snowmelt model for estimating the snowmelt runoff generated by seasonal snow in Tianshan Mountains. [Method] Three snow water collecting sites were set on a sunny sl... [Objective] The study aimed to apply energy balance snowmelt model for estimating the snowmelt runoff generated by seasonal snow in Tianshan Mountains. [Method] Three snow water collecting sites were set on a sunny slope in western Tianshan Mountains to measure the snowmelt rates at hourly interval. The positive sensible heat and negative latent heat fluxes were calculated by the energy balance snowmelt model; the snowmelt rate was also estimated by the model. Finally, the ac- curacy for the model was investigated in detail. [Result] The results indicated that sensible heat fluxes and latent heat fluxes accounted for 13.4% of total energy input and 15.1% of energy output, respectively. A good agreement between observed and estimated SWE was proved by low volume difference and the high Nash-Sutcliff coef- ficients(R2) which were 0.86, 0.92 and 0.91, respectively. [Conclusion] The energy balance snowmelt model has been proved to be a powerful tool for snowmelt estimation. 展开更多
关键词 SNOWMELT Energy balance Sensible heat Latent heat
下载PDF
Effects of working parameters on gasoline engine exergy balance 被引量:9
14
作者 LIU Jing-ping FU Jian-qin +1 位作者 FENG Ren-hua ZHU Guo-hui 《Journal of Central South University》 SCIE EI CAS 2013年第7期1938-1946,共9页
To improve the energy utilization efficiency of internal combustion (IC) engine, exergy analysis was conducted on a passenger car gasoline engine. According to the thermodynamic theory of IC engine, in-cylinder exer... To improve the energy utilization efficiency of internal combustion (IC) engine, exergy analysis was conducted on a passenger car gasoline engine. According to the thermodynamic theory of IC engine, in-cylinder exergy balance model was built. The working processes of gasoline engine were simulated by using the GT-power. In this way, the required parameters were calculated and then gasoline engine exergy balance was obtained by programming on computer. On this basis, the influences of various parameters on exergy balance were analyzed. Results show that, the proportions of various forms of exergy in gasoline engine from high to low are irreversible loss, effective work, exhaust gas exergy and heat transfer exergy. Effective exergy proportion fluctuates with cylinder volumetric efficiency at full load, while it always increases with break mean effective pressure (BMEP) at part load. Exhaust gas exergy proportion is more sensitive to speed, and it increases with speed increasing except at the highest speed. The lower proportion of heat transfer exergy appears at high speed and high load. Irreversible loss is mainly influenced by load. At part load, higher BMEP results in lower proportion of irreversible loss; at full load, the proportion of irreversible loss changes little except at the highest speed. 展开更多
关键词 gasoline engine exergy balance waste heat recovery thermal efficiency energy conservation
下载PDF
Recent Energy Balance of Earth 被引量:1
15
作者 Robert S. Knox David H. Douglass 《International Journal of Geosciences》 2010年第3期99-101,共3页
A recently published estimate of Earth’s global warming trend is 0.63 ± 0.28 W/m2, as calculated from ocean heat content anomaly data spanning 1993-2008. This value is not representative of the recent (2003-2008... A recently published estimate of Earth’s global warming trend is 0.63 ± 0.28 W/m2, as calculated from ocean heat content anomaly data spanning 1993-2008. This value is not representative of the recent (2003-2008) warming/cooling rate because of a “flattening” that occurred around 2001-2002. Using only 2003-2008 data from Argo floats, we find by four different algorithms that the recent trend ranges from –0.010 to –0.161 W/m2 with a typical error bar of ±0.2 W/m2. These results fail to support the existence of a frequently-cited large positive computed radiative imbalance. 展开更多
关键词 Energy balance RADIATIVE IMbalance OCEAN heat Content
下载PDF
Effect of the Lower Boundary Position of the Fourier Equation on the Soil Energy Balance
16
作者 孙菽芬 张霞 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2004年第6期868-878,共11页
In this study, the e?ect of the lower boundary position selection for the Fourier equation on heat transfer and energy balance in soil is evaluated. A detailed numerical study shows that the proper position of the l... In this study, the e?ect of the lower boundary position selection for the Fourier equation on heat transfer and energy balance in soil is evaluated. A detailed numerical study shows that the proper position of the lower boundary is critical when solving the Fourier equation by using zero heat ?ux as the lower boundary condition. Since the position de?nes the capacity of soil as a heat sink or source, which absorbs and stores radiation energy from the sky in summer and then releases the energy to the atmosphere in winter, and regulates the deep soil temperature distribution, the depth of the position greatly in?uences the heat balance within the soil as well as the interaction between the soil and the atmosphere. Based on physical reasoning and the results of numerical simulation, the proper depth of the position should be equal to approximately 3 times of the annual heat wave damping depth. For most soils, the proper lower boundary depth for the Fourier equation should be around 8 m to 15 m, depending on soil texture. 展开更多
关键词 thermal conductivity lower boundary position effect on heat balance
下载PDF
RADIATION BALANCE AND MICROCLIMATIC FEATURES OF MARSH IN THE SANJIANG PLAIN
17
作者 刘兴土 《Chinese Geographical Science》 SCIE CSCD 1991年第4期57-68,共12页
Radiation balance, soil temperature and the temperature and humidity of air were measured in marshes and reclaimed farmlands of the Sanjing Plain. Soil-heat flux was calculated with two different methods. Through the ... Radiation balance, soil temperature and the temperature and humidity of air were measured in marshes and reclaimed farmlands of the Sanjing Plain. Soil-heat flux was calculated with two different methods. Through the analysis of a lot of data, the daily variations and the law of vertical distribution of microclimate factors on marsh surface was obtained. It is found that after marshes are reclaimed, radiation balance increases, both soil temperature at different depths and air temperature of various height near ground layer rise, and air humidity decreases obviously. Therefore, one should take the establishment of artificial ecosystem of growing paddy and reed and breeding fish as the main development direction of marshes, at the same time, protect some marshes in order to prevent the environment from getting dry, and maintain regional ecological balance. 展开更多
关键词 MARSH RADIATION balance MICROCLIMATE soil-heat FLUX
下载PDF
Load-Balance Policy in Two Level-Cluster File System
18
作者 LIU Yuling SONG Weiwei MA Xiaoxue 《Wuhan University Journal of Natural Sciences》 CAS 2006年第6期1935-1938,共4页
In this paper, we explored a load-balancing algorithm in a cluster file system contains two levels of metadata-server, primary-level server quickly distributestasks to second-level servers depending on the closest loa... In this paper, we explored a load-balancing algorithm in a cluster file system contains two levels of metadata-server, primary-level server quickly distributestasks to second-level servers depending on the closest load-balancing information. At the same time, we explored a method which accurately reflect I/O traffic and storage of storage-node: computing the heat-value of file, according to which we realized a more logical storage allocation. According to the experiment result, we conclude that this new algorithm shortens the executing time of tasks and improves the system performance compared with other load algorithm. 展开更多
关键词 cluster file system metadata-server LOAD-balancING value of heat
下载PDF
Improving Energy Efficiency of Tunnel Furnace by Using Heat Optimization Model
19
作者 Arup Mallick Subir Banerjee +5 位作者 Ranjay Kumar Singh P. N. Shivangi Pinder Singh Mandley Biswajit Ghosh Chaitanya Bhanu Mrityunjay Kumar Singh 《World Journal of Mechanics》 2024年第9期185-198,共14页
Reheating furnace of an integrated steel plant consumes intensive fuel as input energy to heat up stocks prior to hot rolling process. In current scenario, the elevated cost of productivity due to increasing fuel pric... Reheating furnace of an integrated steel plant consumes intensive fuel as input energy to heat up stocks prior to hot rolling process. In current scenario, the elevated cost of productivity due to increasing fuel price is emerging as a key concern for the steel industry. A continuous improvement in reduction of fuel consumption is one of the key objectives for the manufacturing units. Numerous research work is going on worldwide to increase the energy efficiency of reheating furnaces. Computational Fluid Dynamics (CFD) and numerical modelling are mostly being used for predicting thermal and reactive fluid characteristic inside a furnace. However, the said methods are very expensive and require a huge infrastructure to compute the results. In addition, these results are not available on real time basis to take corrective action due to high computational time. In this article, an alternative approach has been adopted where complete heat and mass balance of entire tunnel type reheating furnace has been carried out. This study includes first principle-based model where heat conduction, convection and radiation with combustion reactions of the fuel components have been considered. Based on these theoretical calculations, the model is used to identify heat losses at various locations of the furnace. Moreover, a method to optimize the mixing ratio of air and fuel (mixed gas) along with monitoring of heat recovery from combined recuperator have been covered. Based on the model outcome, a significant improvement in furnace efficiency has been achieved, leading to reduction in fuel consumption in the range of 12%. 展开更多
关键词 heat balance Energy Efficiency Reheating Furnace Fuel Consumption Air-Fuel Ratio
下载PDF
庞氏安胎止血汤通过调控NLRP3炎症小体改善热证自然流产的作用机制
20
作者 马丽亚 吴星霏 +8 位作者 吴刘俊 申艳朵 谢秉恒 张家乐 郝锦浩 于梦 中山裕美子 张明昊 张大伟 《中国药房》 北大核心 2025年第1期37-43,共7页
目的研究庞氏安胎止血汤通过调控NOD样受体蛋白3(NLRP3)炎症小体改善热证自然流产的作用机制。方法采用分子对接技术预测庞氏安胎止血汤中13种主要活性成分与NLRP3、凋亡相关斑点样蛋白质(ASC)、胱天蛋白酶1前体(pro-caspase-1)的结合... 目的研究庞氏安胎止血汤通过调控NOD样受体蛋白3(NLRP3)炎症小体改善热证自然流产的作用机制。方法采用分子对接技术预测庞氏安胎止血汤中13种主要活性成分与NLRP3、凋亡相关斑点样蛋白质(ASC)、胱天蛋白酶1前体(pro-caspase-1)的结合活性。将60只孕1 d大鼠随机分为正常组、模型组、地屈孕酮组(0.002 g/kg)和庞氏安胎止血汤低、中、高剂量组(11.025、22.05、44.10 g/kg),每组10只。各组大鼠灌胃蒸馏水/相应药液,每天1次,连续12 d。除正常组外,其余各组大鼠采用温阳中药和米非司酮诱导热证自然流产模型。末次给药24 h后,检测大鼠血清中三碘甲状腺原氨酸(T3)、甲状腺素(T4)、白细胞介素2(IL-2)、IL-4、IL-6、IL-10、γ干扰素(IFN-γ)水平;计算流产率及子宫系数;观察大鼠妊娠子宫病理形态;检测妊娠子宫中NLRP3、ASC、caspase-1蛋白表达水平。结果分子对接结果显示,庞氏安胎止血汤13种主要活性成分与NLRP3、ASC、pro-caspase-1蛋白的结合能均小于-5 kJ/mol。动物实验结果显示,与正常组比较,模型组大鼠子宫系数和血清中IL-4、IL-6、IL-10水平均显著降低(P<0.05),流产率和血清中T3、T4、IL-2、IFN-γ水平以及妊娠子宫中NLRP3、ASC、caspase-1蛋白表达水平均显著升高(P<0.05),妊娠子宫内膜存在流产病变;与模型组比较,庞氏安胎止血汤各剂量组大鼠上述大部分定量指标均显著逆转(P<0.05),妊娠子宫内膜流产病变均有不同程度改善。结论庞氏安胎止血汤可能通过调节NLRP3炎症小体形成,下调IFN-γ、IL-2等促炎因子,上调IL-4、IL-6、IL-10等抑炎因子,从而影响母胎之间的免疫平衡,进而发挥改善热证自然流产的作用。 展开更多
关键词 庞氏安胎止血汤 热证 自然流产 NOD样受体蛋白3 免疫平衡
下载PDF