期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter 被引量:2
1
作者 庄兆意 张承虎 +1 位作者 王海燕 孙德兴 《Transactions of Tianjin University》 EI CAS 2010年第6期461-466,共6页
Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running... Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi... 展开更多
关键词 sewage source heat pump unit coefficient of performance (COP) partial load parallel operation
下载PDF
Simulation of the flow and thermal breakthrough of a forced external circulation standing column well
2
作者 Wei Song Changjin Zheng +2 位作者 Bo Zhang Yue Jin Yuanzhou Liu 《Energy and Built Environment》 2022年第3期267-277,共11页
The flow and thermal breakthrough phenomenon in a forced external circulation standing column well(FECSCW)directly affects heat transfer efficiency and load-carrying capacity.A numerical model for FECSCW is developed ... The flow and thermal breakthrough phenomenon in a forced external circulation standing column well(FECSCW)directly affects heat transfer efficiency and load-carrying capacity.A numerical model for FECSCW is developed to analyze the migration of the temperature and velocity front under the flow and thermal breakthrough.The results indicated that thermal breakthrough began after simulation running 2.5 min and was completely formed after 12 min.The inlet water,which directly entered the production well without heat exchange with the aquifer,accounted for 12.8%.When the porosity of the backfill material decreased from 0.35 to 0,the coefficient of per-formance(COP)of the heat pump unit increased by 1.6%on average,and the thermal breakthrough strength decreased by an average of 45.3%within 25 min.Where seepage velocity near the well wall was greater than 1×10^(−3) m·s^(−1),faster velocity front migration was observed,while the migration advantage of the temperature front was more prominent outside of this region.Through quantitative analysis of flow and thermal breakthrough,temperature and velocity front migration,and COP change of heat pump unit,theoretical suggestions were pro-vided for the thermal transfer mechanism near the thermal well wall.The extended research in this study can be applied to the design and optimization of forced external circulation standing column well system. 展开更多
关键词 Forced external circulation standing column well Numerical simulation Velocity front Flow breakthrough Thermal breakthrough strength Coefficient of performance of heat pump unit
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部