Meeting the climate change mitigation targets will require a substantial shift from fossil to clean fuels in the heating sector.Heat pumps with deep borehole exchangers are a promising solution to reduce emissions.Her...Meeting the climate change mitigation targets will require a substantial shift from fossil to clean fuels in the heating sector.Heat pumps with deep borehole exchangers are a promising solution to reduce emissions.Here the thermal behavior of deep borehole exchangers(DBHEs)ranging from 1 to 2 km was analyzed for various heat flow profiles.A strong correlation between thermal energy extraction and power output from DBHEs was found,also influenced by the heating profile employed.Longer operating time over the year typically resulted in higher energy production,while shorter one yielded higher average thermal power output,highlighting the importance of the choice of heating strategy and system design for optimal performance of DBHEs.Short breaks in operation for regenerating the borehole,for example,with waste heat,proved to be favorable for the performance yielding an overall heat output close to the same as with continuous extraction of heat.The results demonstrate the usefulness of deep boreholes for dense urban areas with less available space.As the heat production from a single DBHE in Finnish conditions ranges from half up to even a few GWh a year,the technology is best suitable for larger heat loads.展开更多
In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model wi...In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model with freezing/melting phase changes is developed for the heat transfer analysis of the soil.Based on the numerical solution of the model,the variation trends of underground soil temperature of the SGSHPS operated in various alternate operation modes are discussed.The results indicate that,for the day-night and short-time interval alternate operation modes without solar energy,the operation time fraction of a solar heat source should be confined to from 50% to 58% when operated in an alternate period of 24 h.Meanwhile,the disadvantages of a natural resumption of soil temperature can be overcome effectively by solar energy filling,and an optimal operation effect can be achieved by integrating the mode of solar energy filling with other alternate modes.In addition,the accuracy of the presented model is verified by the experimental data of borehole wall temperatures.The conclusions can provide a reference for the optimization operation of the SGSHPS.展开更多
To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and p...To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and performance of the heat pump part of this new heating system are studied.Based on a SASHP with 10 kW,the mathematical model of this system is built,and the characteristics and performance are concluded from the simulation analysis at different environmental temperatures and output water temperatures.The results show that the performance of heat pumps can be greatly improved based on the new SASHP.When the environmental temperature is 7 ℃,the coefficient of performance(COP)of the air-source heat pump(ASHP)can be increased by 26% at most.This paper sets up a base for further study on the heating system with this new SASHP in the heating season.展开更多
Aiming to resolve the problem that conventional sewage source heat pump systems cannot satisfy heat peak loads of buildings,a new idea that the freezing latent heat is exacted as the auxiliary heat source at the peak ...Aiming to resolve the problem that conventional sewage source heat pump systems cannot satisfy heat peak loads of buildings,a new idea that the freezing latent heat is exacted as the auxiliary heat source at the peak heat load is proposed.First,on the basis of sewage characteristics,a freezing latent heat exchanger is developed to safely eliminate ice,continuously extract heat and remove sewage soft-dirt.A reasonable form of the urban sewage source heat pump system with freezing latent heat collection is presented.Then,the feasibility of the system is theoretically analyzed.The calculation results under typical operating conditions show that the heating ability of the new system is higher than that of the conventional one and the ratio of these two highest heating rates is between 4.5 and 8.7,which proves that the new system has great application potential in cold regions.展开更多
A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building...A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.展开更多
Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is fo...Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil.展开更多
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ...An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.展开更多
Based on the Chinese National Standards involving heat pump water heater and space heating system, performances of the R744/R290 subcritical heat pump system have been discussed and compared with those of the R22 syst...Based on the Chinese National Standards involving heat pump water heater and space heating system, performances of the R744/R290 subcritical heat pump system have been discussed and compared with those of the R22 system, which is widely used in heat pump systems in China nowadays. It can be indicated that R744/R290 mixture can work efficiently as a refrigerant for heat pumps with a large heat-sink temperature rise. When mass fraction of R290 is increased, discharge pressure is reduced. Under the nominal working condition, there is an optimum mixture mass fraction of 20/80 for R744/R290 under conventional condensation pressure. Both the heating COPhs (coefficient of performance) and volumetric heating capacity are increased by about 12.62% and 34.24% respectively compared with those of R22 based system. But for the heat sink with a small temperature rise, R744/R290 system has poorer performances than R22 system. When heat transfer pinch point in evaporator and condensation processes is considered, the degree of superheat has a negative influence upon system performances under the given conditions.展开更多
Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2...Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2-based in the HTHP in different running conditions.The results demonstrated the feasibility and reliability of M1 and M2 as new high-temperature refrigerants.Additionally,the exploration and analyses of the support vector machine(SVM)and back propagation(BP)neural network models were made to find a practical way to predict the performance of HTHP system.The results showed that SVM-Linear,SVM-RBF and BP models shared the similar ability to predict the heat capacity and power input with high accuracy.SVM-RBF demonstrated better stability for coefficient of performance prediction.Finally,the proposed SVM model was used to assess the potential of the M1 and M2.The results indicated that the HTHP system using M1 could produce heat at the temperature of 130°C with good performance.展开更多
A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results, in which the solar collector was combined serially with a ground-coupled heat pump (GCHP). The uni...A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results, in which the solar collector was combined serially with a ground-coupled heat pump (GCHP). The universal optimal equations were solved by the constrained variable metric method considering both the per-formance and economics. Then the model was applied to a specific case concerning an actual solar assisted GCHP system for space heating. The results indicated a system coefficient of performance (COP) of 3.9 for the optimal method under the serial heating mode, and 3.2 for the conventional one. In addition, the optimum solution also showed advantages in energy and cost saving, leading to a 16.7% improvement in the heat pump performance at 17.2% less energy consumption and 11.8% lower annual cost, respectively.展开更多
Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and t...Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and the parameters of temperature and flow rate in different parts of system were measured during this period. The seasonal energy efficiency ratio was calculated and the performance of heat pump system in summer was compared with that in winter. The result shows that the coefficient of performance of the system reaches 3.63 in summer and 3.49 in winter, respectively. The heat balance in underground rock mass is acquired basically throughout the year, and the heat accumulation in the earth tends to be zero.展开更多
The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is...The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.展开更多
Here, we propose a chemical heat pump chiller with a SrBr<sub>2</sub> hydration reaction system for utilization of waste heat. The SrBr<sub>2</sub> hydration reaction could recover waste heat i...Here, we propose a chemical heat pump chiller with a SrBr<sub>2</sub> hydration reaction system for utilization of waste heat. The SrBr<sub>2</sub> hydration reaction could recover waste heat in low temperatures ranging from 373 K to 353 K, and the system showed good potential in terms of the high cooling thermal-storage density. Previous studies have given little information on the reaction characteristics of the SrBr<sub>2</sub> hydration reaction. In this paper, we developed a measuring method for the hydration reaction equilibrium and reaction rate based on the volumetric method. We analyzed the hydration reaction rate with an unreacted-core shell model. In the experiments, the SrBr<sub>2</sub> equilibrium temperature observed was equal to the theoretical equilibrium temperature obtained from thermodynamic databases. In addition, the hysteresis gap between the hydration and dehydration values was 2.0 K. Thus, the hysteresis effect was negligible for the chemical heat pump cooling operation. The reaction fraction of the SrBr<sub>2</sub> hydration reached 0.7 within 20 s. By analyzing the hydration reaction rate with the unreacted-core shell model, the activation energy value was calculated to be56.6 kJ/mol. The calculation results showed good agreement with those of the experiment as the reaction fraction reached 0.7.展开更多
This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air h...This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5.展开更多
To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and pre...To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and presents a new on-line self-flushing technique, which alternately flushes part of heat transfer tubes. In addition, operation principles and the structure of the new heat-exchanger are introduced and the feasible economi- cal and technological cleaning plans are given by design calculation and scheme comparison. The result shows that keeping each tube washed for one minute with 5 m/s, the operating cost is lower than ¥5 and when one flushing pump ahemately flushes 10-20 heat exchangers, the saved costs of flushing 10 tubes alternately are over 4 times of the increased costs.展开更多
A novel tobacco-curing system with a solar-assisted heat pump was proposed.The proposed system has various advantages,such as reducing energy consumption and pollutant emissions and enhancing the stability of system o...A novel tobacco-curing system with a solar-assisted heat pump was proposed.The proposed system has various advantages,such as reducing energy consumption and pollutant emissions and enhancing the stability of system operation.The thermal characteristics of the system under different climate conditions were analyzed,and the economic and environmental benefits of different tobacco-curing technologies were compared.Results indicated that the dehydration rate,the mass flux of exhaust air,and the heat load of the novel tobacco-curing system in different months had similar changes with the baking time,and all reached the maximum in the later stage of color fixing.Compared with the power saving rate of a heat pump tobacco-curing system,that of the novel system reached 25.9%-35.1%.The dry leaf curing cost of the novel system was only 0.86-1.06 yuan/kg,which can reduce the cost by more than 60%compared with traditional coal-burning tobacco-curing systems in China.Compared with other parts of the tobacco leaf,the top leaf had the lowest dry leaf curing cost due to its highest mass of dry leaf.The payback period and the annual CO_(2) emission reduction of the novel system were 3.0-3.7 a and 15586 kg,respectively.展开更多
An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat trans...An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat transfer throughout the backfill medium due to the presence of the second loop.The verification of the model was achieved by the implementation of five different borehole configurations and a comparison with other correlations in the available literature.The model considered a U-tube spacing range between(2)and(4)times the U-tube outside diameter producing a geometry configuration factor range of(0.29-0.6).The results of the model were utilized for the assessment of the DX ground heat exchanger coupled heat pump system.For similar geometrical configurations,the borehole thermal resistance experienced a decrease as the geometry factor increased.The single U-tube borehole thermal resistance was higher than that of the double U-tube heat exchanger by(10-27)%for the examined geometry configurations.The borehole thermal resistance at tube spacing of twice the tube diameter was higher than the predicted value at the triple diameter and fell in the range of(18-34)%.展开更多
In view of the Three North areas existing wind power absorption and environment pollution problems,the previous scholars have improved the wind abandon problem by adding electrothermal coupling equipment or optimizing...In view of the Three North areas existing wind power absorption and environment pollution problems,the previous scholars have improved the wind abandon problem by adding electrothermal coupling equipment or optimizing power grid operation.In this paper,an electrothermal integrated energy system including heat pump and thermal storage units was proposed.The scheduling model was based on the load data and the output characteristics of power units,each power unit capacity was programmed without constraints,and the proposed scheduling model was compared with the traditional combined heat and power scheduling model.Results showed that the investment and pollutant discharge of the system was reduced respectively.Wind power was fully absorbed.Compared with the traditional thermal power unit,the proportion of the output was significantly decreased by the proposed model.The proposed system could provide a new prospect for wind power absorption and environment protection.展开更多
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr...To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.展开更多
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e...For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.展开更多
文摘Meeting the climate change mitigation targets will require a substantial shift from fossil to clean fuels in the heating sector.Heat pumps with deep borehole exchangers are a promising solution to reduce emissions.Here the thermal behavior of deep borehole exchangers(DBHEs)ranging from 1 to 2 km was analyzed for various heat flow profiles.A strong correlation between thermal energy extraction and power output from DBHEs was found,also influenced by the heating profile employed.Longer operating time over the year typically resulted in higher energy production,while shorter one yielded higher average thermal power output,highlighting the importance of the choice of heating strategy and system design for optimal performance of DBHEs.Short breaks in operation for regenerating the borehole,for example,with waste heat,proved to be favorable for the performance yielding an overall heat output close to the same as with continuous extraction of heat.The results demonstrate the usefulness of deep boreholes for dense urban areas with less available space.As the heat production from a single DBHE in Finnish conditions ranges from half up to even a few GWh a year,the technology is best suitable for larger heat loads.
基金The National Key Technology R&D Program of Chinaduring the 11th Five-Year Plan Period(No.2008BAJ12B04)China Postdoctoral Science Foundation(No.20090461050)+1 种基金the Project of Researchand Development of Ministry of Housing and Urban-Rural Development ofChina(No.2008-K1-26)the New Century Talent Project of Yangzhou University for Excellent Young Backbone Teacher(2008)
文摘In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model with freezing/melting phase changes is developed for the heat transfer analysis of the soil.Based on the numerical solution of the model,the variation trends of underground soil temperature of the SGSHPS operated in various alternate operation modes are discussed.The results indicate that,for the day-night and short-time interval alternate operation modes without solar energy,the operation time fraction of a solar heat source should be confined to from 50% to 58% when operated in an alternate period of 24 h.Meanwhile,the disadvantages of a natural resumption of soil temperature can be overcome effectively by solar energy filling,and an optimal operation effect can be achieved by integrating the mode of solar energy filling with other alternate modes.In addition,the accuracy of the presented model is verified by the experimental data of borehole wall temperatures.The conclusions can provide a reference for the optimization operation of the SGSHPS.
基金The National Natural Science Foundation of China(No.50676018)the National Key Technology R&D Program of China during the 11th Five-Year Plan Period(No.2008BAJ12B02)
文摘To further improve the utilization efficiency of solar energy and the performance of solar heat pump heating systems,a new heating mode of a solar air-source heat pump(SASHP)is proposed,and the characteristics and performance of the heat pump part of this new heating system are studied.Based on a SASHP with 10 kW,the mathematical model of this system is built,and the characteristics and performance are concluded from the simulation analysis at different environmental temperatures and output water temperatures.The results show that the performance of heat pumps can be greatly improved based on the new SASHP.When the environmental temperature is 7 ℃,the coefficient of performance(COP)of the air-source heat pump(ASHP)can be increased by 26% at most.This paper sets up a base for further study on the heating system with this new SASHP in the heating season.
基金The National Key Technology R&D Program of Chinaduring the 11th Five-Year Plan Period(No.2008BAJ12B05-05)the Research Foundation of Education Bureau of Heilongjiang Province,China(No.11551114)the China Postdoctoral Science Foundation(No.20100471438).
文摘Aiming to resolve the problem that conventional sewage source heat pump systems cannot satisfy heat peak loads of buildings,a new idea that the freezing latent heat is exacted as the auxiliary heat source at the peak heat load is proposed.First,on the basis of sewage characteristics,a freezing latent heat exchanger is developed to safely eliminate ice,continuously extract heat and remove sewage soft-dirt.A reasonable form of the urban sewage source heat pump system with freezing latent heat collection is presented.Then,the feasibility of the system is theoretically analyzed.The calculation results under typical operating conditions show that the heating ability of the new system is higher than that of the conventional one and the ratio of these two highest heating rates is between 4.5 and 8.7,which proves that the new system has great application potential in cold regions.
基金The National Natural Science Foundation of China(No. 51036001 )the Natural Science Foundation of Jiangsu Province(No. BK2010043)
文摘A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProject(2010DFA72740-05) supported by the International Science & Technology Cooperation Program of China
文摘Based on the state-of-the-art studies of solar-soil source heat pump compound system, operation patterns of solar-soil compound system were analyzed, particularly the advantages of parallel operation pattern. It is found that parallel operation pattern is better for solar-soil compound system. Furthermore, the heat balance issue of solar-soil compound system was emphatically analyzed from four aspects, which were annual analysis of heating and cooling load, the heat exchange of ground heat exchanger, capacity determination of solar-assisted heat sottrce and heat balance calculation of solar-soil compound system. Moreover, annual rate of heat balance in a solar-soil source heat pump compound system was calculated with a case study. It is shown that the annual heat unbalance ratio is 19%, which is less than 20%. As a result, the practical solar-soil compound system can basically maintain the heat balance of soil.
基金Supported bythe"11th Five-Year Plan"for National Plans of Major Technology Projects
文摘An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.
文摘Based on the Chinese National Standards involving heat pump water heater and space heating system, performances of the R744/R290 subcritical heat pump system have been discussed and compared with those of the R22 system, which is widely used in heat pump systems in China nowadays. It can be indicated that R744/R290 mixture can work efficiently as a refrigerant for heat pumps with a large heat-sink temperature rise. When mass fraction of R290 is increased, discharge pressure is reduced. Under the nominal working condition, there is an optimum mixture mass fraction of 20/80 for R744/R290 under conventional condensation pressure. Both the heating COPhs (coefficient of performance) and volumetric heating capacity are increased by about 12.62% and 34.24% respectively compared with those of R22 based system. But for the heat sink with a small temperature rise, R744/R290 system has poorer performances than R22 system. When heat transfer pinch point in evaporator and condensation processes is considered, the degree of superheat has a negative influence upon system performances under the given conditions.
基金Project (2015CB251403) supported by the National Key Basic Research Program of China(973)
文摘Two new binary near-azeotropic mixtures named M1 and M2 were developed as the refrigerants of the high-temperature heat pump(HTHP).The experimental research was used to analyze and compare the performance of M1 and M2-based in the HTHP in different running conditions.The results demonstrated the feasibility and reliability of M1 and M2 as new high-temperature refrigerants.Additionally,the exploration and analyses of the support vector machine(SVM)and back propagation(BP)neural network models were made to find a practical way to predict the performance of HTHP system.The results showed that SVM-Linear,SVM-RBF and BP models shared the similar ability to predict the heat capacity and power input with high accuracy.SVM-RBF demonstrated better stability for coefficient of performance prediction.Finally,the proposed SVM model was used to assess the potential of the M1 and M2.The results indicated that the HTHP system using M1 could produce heat at the temperature of 130°C with good performance.
基金Supported by National Major Project of Scientific and Technical Programs of China During the 11th Five-Year Plan Period (No. 2006BAJ03A06)Tianjin Municipal Project for Science and Technology Development Plan (No. 06YFSYSF03600).
文摘A mathematical optimization model was set up for a ground-solar combined system based on in-situ experimental results, in which the solar collector was combined serially with a ground-coupled heat pump (GCHP). The universal optimal equations were solved by the constrained variable metric method considering both the per-formance and economics. Then the model was applied to a specific case concerning an actual solar assisted GCHP system for space heating. The results indicated a system coefficient of performance (COP) of 3.9 for the optimal method under the serial heating mode, and 3.2 for the conventional one. In addition, the optimum solution also showed advantages in energy and cost saving, leading to a 16.7% improvement in the heat pump performance at 17.2% less energy consumption and 11.8% lower annual cost, respectively.
基金Project(50838009) supported by the National Science Key Foundation 1 tem
文摘Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and the parameters of temperature and flow rate in different parts of system were measured during this period. The seasonal energy efficiency ratio was calculated and the performance of heat pump system in summer was compared with that in winter. The result shows that the coefficient of performance of the system reaches 3.63 in summer and 3.49 in winter, respectively. The heat balance in underground rock mass is acquired basically throughout the year, and the heat accumulation in the earth tends to be zero.
基金Project(2012BAJ06B04)supported by"12th Five-Year Plan"National science and Technology,ChinaProject(2014-228)supported by Department of Housing and Urban Rural Development of Hebei,China
文摘The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.
文摘Here, we propose a chemical heat pump chiller with a SrBr<sub>2</sub> hydration reaction system for utilization of waste heat. The SrBr<sub>2</sub> hydration reaction could recover waste heat in low temperatures ranging from 373 K to 353 K, and the system showed good potential in terms of the high cooling thermal-storage density. Previous studies have given little information on the reaction characteristics of the SrBr<sub>2</sub> hydration reaction. In this paper, we developed a measuring method for the hydration reaction equilibrium and reaction rate based on the volumetric method. We analyzed the hydration reaction rate with an unreacted-core shell model. In the experiments, the SrBr<sub>2</sub> equilibrium temperature observed was equal to the theoretical equilibrium temperature obtained from thermodynamic databases. In addition, the hysteresis gap between the hydration and dehydration values was 2.0 K. Thus, the hysteresis effect was negligible for the chemical heat pump cooling operation. The reaction fraction of the SrBr<sub>2</sub> hydration reached 0.7 within 20 s. By analyzing the hydration reaction rate with the unreacted-core shell model, the activation energy value was calculated to be56.6 kJ/mol. The calculation results showed good agreement with those of the experiment as the reaction fraction reached 0.7.
文摘This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5.
基金Sponsored by the National Natural Science Foundation of China (Grant No.50578048)
文摘To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and presents a new on-line self-flushing technique, which alternately flushes part of heat transfer tubes. In addition, operation principles and the structure of the new heat-exchanger are introduced and the feasible economi- cal and technological cleaning plans are given by design calculation and scheme comparison. The result shows that keeping each tube washed for one minute with 5 m/s, the operating cost is lower than ¥5 and when one flushing pump ahemately flushes 10-20 heat exchangers, the saved costs of flushing 10 tubes alternately are over 4 times of the increased costs.
基金The National Natural Science Foundation of China(No.51922027).
文摘A novel tobacco-curing system with a solar-assisted heat pump was proposed.The proposed system has various advantages,such as reducing energy consumption and pollutant emissions and enhancing the stability of system operation.The thermal characteristics of the system under different climate conditions were analyzed,and the economic and environmental benefits of different tobacco-curing technologies were compared.Results indicated that the dehydration rate,the mass flux of exhaust air,and the heat load of the novel tobacco-curing system in different months had similar changes with the baking time,and all reached the maximum in the later stage of color fixing.Compared with the power saving rate of a heat pump tobacco-curing system,that of the novel system reached 25.9%-35.1%.The dry leaf curing cost of the novel system was only 0.86-1.06 yuan/kg,which can reduce the cost by more than 60%compared with traditional coal-burning tobacco-curing systems in China.Compared with other parts of the tobacco leaf,the top leaf had the lowest dry leaf curing cost due to its highest mass of dry leaf.The payback period and the annual CO_(2) emission reduction of the novel system were 3.0-3.7 a and 15586 kg,respectively.
文摘An analytical model was built to predict the thermal resistance of a vertical double U-tube ground-coupled heat pump that operates under steady-state conditions.It included a geometry obstruction factor for heat transfer throughout the backfill medium due to the presence of the second loop.The verification of the model was achieved by the implementation of five different borehole configurations and a comparison with other correlations in the available literature.The model considered a U-tube spacing range between(2)and(4)times the U-tube outside diameter producing a geometry configuration factor range of(0.29-0.6).The results of the model were utilized for the assessment of the DX ground heat exchanger coupled heat pump system.For similar geometrical configurations,the borehole thermal resistance experienced a decrease as the geometry factor increased.The single U-tube borehole thermal resistance was higher than that of the double U-tube heat exchanger by(10-27)%for the examined geometry configurations.The borehole thermal resistance at tube spacing of twice the tube diameter was higher than the predicted value at the triple diameter and fell in the range of(18-34)%.
基金the fund program of research on re-electrification(heat pump clean heating)to promote the new energy consumption in Shaanxi power grid(5226KY18002P).
文摘In view of the Three North areas existing wind power absorption and environment pollution problems,the previous scholars have improved the wind abandon problem by adding electrothermal coupling equipment or optimizing power grid operation.In this paper,an electrothermal integrated energy system including heat pump and thermal storage units was proposed.The scheduling model was based on the load data and the output characteristics of power units,each power unit capacity was programmed without constraints,and the proposed scheduling model was compared with the traditional combined heat and power scheduling model.Results showed that the investment and pollutant discharge of the system was reduced respectively.Wind power was fully absorbed.Compared with the traditional thermal power unit,the proportion of the output was significantly decreased by the proposed model.The proposed system could provide a new prospect for wind power absorption and environment protection.
文摘To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.
基金This work was supported by the National Key Research and Development Program of China(No.2019YFE0193200 KY202001)Science and Technology Planning Project of Beijing(No.Z201100008320001 KY191004).
文摘For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.