In view of the limitations of solid metal heat sink in the heat dissipation of high power light emitting diode (LED), a kind of miniaturized phase change heat sink is developed for high power LED packaging. First, t...In view of the limitations of solid metal heat sink in the heat dissipation of high power light emitting diode (LED), a kind of miniaturized phase change heat sink is developed for high power LED packaging. First, the fabrication process of miniaturized phase change heat sink is investigated, upon which all parts of the heat sink are fabricated including main-body and end-cover of the heat sink, the formation of three-dimensional boiling structures at the evaporation end, the sintering of the wick, and the encapsulation of high power LED phase change heat sink. Subsequently, with the assistance of the developed testing system, heat transfer performance of the heat sink is tested under the condition of natural convection, upon which the influence of thermal load and working medium on the heat transfer performance is investigated. Finally, the heat transfer performance of the developed miniaturized phase change heat sink is compared with that of metal solid heat sink. Results show that the developed miniaturized phase change heat sink presents much better heat transfer performance over traditional metal solid heat sink, and is suitable for the packaging of high power LED.展开更多
In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfe...In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfer power per meter in summer is 97.1% of the test data,and the average value accounts for 81.8%.The per meter heat power data through on-site thermal response test can provide references for designing engineering project and optimizing ground source heat pump system as these data do not vary greatly from the actual monitoring data.展开更多
With the advent of the 5G era,the design of electronic equipment is developing towards thinness,intelligence and multi-function,which requires higher cooling performance of the equipment.Micro-channel heat sink is pro...With the advent of the 5G era,the design of electronic equipment is developing towards thinness,intelligence and multi-function,which requires higher cooling performance of the equipment.Micro-channel heat sink is promising for the heat dissipation of super-thin electronic equipment.In this study,thermal resistance theoretical model of the micro-channel heat sink was first established.Then,fabrication process of the micro-channel heat sink was introduced.Subsequently,heat transfer performance of the fabricated micro-channel heat sink was tested through the developed testing platform.Results show that the developed micro-channel heat sink has more superior heat dissipation performance over conventional metal solid heat sink and it is well suited for high power LEDs application.Moreover,the micro-channel structures in the heat sink were optimized by orthogonal test.Based on the orthogonal optimization,heat dissipation performance of the micro-channel radiator was further improved.展开更多
In this paper an apparatus for measuring heat transfer properties of clothing materials is re-ported.In comparison with the similar device based on constant temperature method and em-ploying a hot plate,the characteri...In this paper an apparatus for measuring heat transfer properties of clothing materials is re-ported.In comparison with the similar device based on constant temperature method and em-ploying a hot plate,the characteristics of this apparatus are as follows.(1)By using microcomputer as its testing control and data processing center,the testingfunction is strengthened,while much more information can be achieved.(2)By using numerical PID control technique supported with software,the informationabout the transient heat transfer properties of clothing materials can be obtained,while the costlowered.In this paper a brief evaluation of the apparatus is also reported.It shows that its accuracyand repeatability reaches the level of similar commercial device,so to some extent the apparatusis practical.展开更多
The front end light-blocked components of the third generation of synchrotron radiation facility,which are subjected to high heat load,are cooled with flowing water through the cooling channels.The convective heat tra...The front end light-blocked components of the third generation of synchrotron radiation facility,which are subjected to high heat load,are cooled with flowing water through the cooling channels.The convective heat transfer coefficient and the flow resistance(or pressure drop) are two important parameters for evaluating the heat transfer performance of the cooling channels and should be strictly quantified.In this research,two typical bent cooling channels in Shanghai Synchrotron Radiation Facility(SSRF) were modeled and their in-pipe turbulent flows were simulated.The two criteria obtained under different channel water velocities met the SSRF technical requirements.To reduce the total pressure drop,arc transitions were proposed to replace the right angle transitions in the cooling channels.At the same time,an experiment was performed to measure the convective heat transfer coefficient of a typical bent channel unit.The experimental results were in good agreement with the simulation ones.展开更多
基金Projects(51575115,51775122)supported by the National Natural Science Foundation of China
文摘In view of the limitations of solid metal heat sink in the heat dissipation of high power light emitting diode (LED), a kind of miniaturized phase change heat sink is developed for high power LED packaging. First, the fabrication process of miniaturized phase change heat sink is investigated, upon which all parts of the heat sink are fabricated including main-body and end-cover of the heat sink, the formation of three-dimensional boiling structures at the evaporation end, the sintering of the wick, and the encapsulation of high power LED phase change heat sink. Subsequently, with the assistance of the developed testing system, heat transfer performance of the heat sink is tested under the condition of natural convection, upon which the influence of thermal load and working medium on the heat transfer performance is investigated. Finally, the heat transfer performance of the developed miniaturized phase change heat sink is compared with that of metal solid heat sink. Results show that the developed miniaturized phase change heat sink presents much better heat transfer performance over traditional metal solid heat sink, and is suitable for the packaging of high power LED.
文摘In this paper,the single hole heat transfer power of the ground source heat pump system in Hengshui is compared with data gained from thermal response test.The results show that maximum monitoring data of heat transfer power per meter in summer is 97.1% of the test data,and the average value accounts for 81.8%.The per meter heat power data through on-site thermal response test can provide references for designing engineering project and optimizing ground source heat pump system as these data do not vary greatly from the actual monitoring data.
基金Supported by the National Natural Science Foundation of China(Grant Nos.51975135 and 52005422)Guangzhou Science and Technology Project(Grant No.201707010429)Special Innovation Projects of Universities in Guangdong Province(Grant No.2018GKTSCX085).
文摘With the advent of the 5G era,the design of electronic equipment is developing towards thinness,intelligence and multi-function,which requires higher cooling performance of the equipment.Micro-channel heat sink is promising for the heat dissipation of super-thin electronic equipment.In this study,thermal resistance theoretical model of the micro-channel heat sink was first established.Then,fabrication process of the micro-channel heat sink was introduced.Subsequently,heat transfer performance of the fabricated micro-channel heat sink was tested through the developed testing platform.Results show that the developed micro-channel heat sink has more superior heat dissipation performance over conventional metal solid heat sink and it is well suited for high power LEDs application.Moreover,the micro-channel structures in the heat sink were optimized by orthogonal test.Based on the orthogonal optimization,heat dissipation performance of the micro-channel radiator was further improved.
文摘In this paper an apparatus for measuring heat transfer properties of clothing materials is re-ported.In comparison with the similar device based on constant temperature method and em-ploying a hot plate,the characteristics of this apparatus are as follows.(1)By using microcomputer as its testing control and data processing center,the testingfunction is strengthened,while much more information can be achieved.(2)By using numerical PID control technique supported with software,the informationabout the transient heat transfer properties of clothing materials can be obtained,while the costlowered.In this paper a brief evaluation of the apparatus is also reported.It shows that its accuracyand repeatability reaches the level of similar commercial device,so to some extent the apparatusis practical.
基金Supported by Natural Science Foundation of China(10975130)
文摘The front end light-blocked components of the third generation of synchrotron radiation facility,which are subjected to high heat load,are cooled with flowing water through the cooling channels.The convective heat transfer coefficient and the flow resistance(or pressure drop) are two important parameters for evaluating the heat transfer performance of the cooling channels and should be strictly quantified.In this research,two typical bent cooling channels in Shanghai Synchrotron Radiation Facility(SSRF) were modeled and their in-pipe turbulent flows were simulated.The two criteria obtained under different channel water velocities met the SSRF technical requirements.To reduce the total pressure drop,arc transitions were proposed to replace the right angle transitions in the cooling channels.At the same time,an experiment was performed to measure the convective heat transfer coefficient of a typical bent channel unit.The experimental results were in good agreement with the simulation ones.