Cascading faults have been identified as the primary cause of multiple power outages in recent years.With the emergence of integrated energy systems(IES),the conventional approach to analyzing power grid cascading fau...Cascading faults have been identified as the primary cause of multiple power outages in recent years.With the emergence of integrated energy systems(IES),the conventional approach to analyzing power grid cascading faults is no longer appropriate.A cascading fault analysis method considering multi-energy coupling characteristics is of vital importance.In this study,an innovative analysis method for cascading faults in integrated heat and electricity systems(IHES)is proposed.It considers the degradation characteristics of transmission and energy supply com-ponents in the system to address the impact of component aging on cascading faults.Firstly,degradation models for the current carrying capacity of transmission lines,the water carrying capacity and insulation performance of thermal pipelines,as well as the performance of energy supply equipment during aging,are developed.Secondly,a simulation process for cascading faults in the IHES is proposed.It utilizes an overload-dominated development model to predict the propagation path of cascading faults while also considering network islanding,electric-heating rescheduling,and load shedding.The propagation of cascading faults is reflected in the form of fault chains.Finally,the results of cascading faults under different aging levels are analyzed through numerical examples,thereby verifying the effectiveness and rationality of the proposed model and method.展开更多
Combined heat and electricity operation with variable mass flow rates promotes flexibility,economy,and sustainability through synergies between electric power systems(EPSs)and district heating systems(DHSs).Such combi...Combined heat and electricity operation with variable mass flow rates promotes flexibility,economy,and sustainability through synergies between electric power systems(EPSs)and district heating systems(DHSs).Such combined operation presents a highly nonlinear and nonconvex optimization problem,mainly due to the bilinear terms in the heat flow model—that is,the product of the mass flow rate and the nodal temperature.Existing methods,such as nonlinear optimization,generalized Benders decomposition,and convex relaxation,still present challenges in achieving a satisfactory performance in terms of solution quality and computational efficiency.To resolve this problem,we herein first reformulate the district heating network model through an equivalent transformation and variable substitution.The reformulated model has only one set of nonconvex constraints with reduced bilinear terms,and the remaining constraints are linear.Such a reformulation not only ensures optimality,but also accelerates the solving process.To relax the remaining bilinear constraints,we then apply McCormick envelopes and obtain an objective lower bound of the reformulated model.To improve the quality of the McCormick relaxation,we employ a piecewise McCormick technique that partitions the domain of one of the variables of the bilinear terms into several disjoint regions in order to derive strengthened lower and upper bounds of the partitioned variables.We propose a heuristic tightening method to further constrict the strengthened bounds derived from the piecewise McCormick technique and recover a nearby feasible solution.Case studies show that,compared with the interior point method and the method implemented in a global bilinear solver,the proposed tightening McCormick method quickly solves the heat–electricity operation problem with an acceptable feasibility check and optimality.展开更多
The effects of the water-cement ratio and the molding temperature on the hydration heat of cement were investigated with semi-adiabatic calorimetry.The specimens were prepared with water-cement ratios of 0.31,0.38,and...The effects of the water-cement ratio and the molding temperature on the hydration heat of cement were investigated with semi-adiabatic calorimetry.The specimens were prepared with water-cement ratios of 0.31,0.38,and 0.45,and the molding temperature was specified at 10 and 20℃.The experimental results show that,as the water-binder ratio increases,the value of the second temperature peak on the temperature curve of the cement paste decreases,and the age at which the peak appears is delayed.The higher the water-cement ratio,the higher the hydration heat release in the early period of cement hydration,but this trend reverses in the late period.There are intersection points of the total hydration heat curve of the cement pastes under the influence of the water-cement ratio,and this law can be observed at both molding temperatures.With the increase in the molding temperature,the age of the second temperature peak on the temperature curve of the cement paste will advance,but the temperature peak will decrease.The higher the molding temperature,the earlier the acceleration period of the cement hydration began,and the larger the hydration heat of the cement in the early stage,but the smaller the total heat in the late period.A subsection function calculation model of the hydration heat,which was based on the existing models,was proposed in order to predict the heat of the hydration of the concrete.展开更多
The significant decrease in battery performance at low temperatures is one of the critical challenges that electric vehicles(EVs)face,thereby affecting the penetration rate in cold regions.Alternating current(AC)heati...The significant decrease in battery performance at low temperatures is one of the critical challenges that electric vehicles(EVs)face,thereby affecting the penetration rate in cold regions.Alternating current(AC)heating has attracted widespread attention due to its low energy consumption and uniform heating advantages.This paper introduces the recent advances in AC heating from the perspective of practical EV applications.First,the performance degradation of EVs in low-temperature environments is introduced briefly.The concept of AC heating and its research methods are provided.Then,the effects of various AC heating methods on battery heating performance are reviewed.Based on existing studies,the main factors that affect AC heating performance are analyzed.Moreover,various heating circuits based on EVs are categorized,and their cost,size,complexity,efficiency,reliability,and heating rate are elaborated and compared.The evolution of AC heaters is presented,and the heaters used in brand vehicles are sorted out.Finally,the perspectives and challenges of AC heating are discussed.This paper can guide the selection of heater implementation methods and the optimization of heating effects for future EV applications.展开更多
The objective of the current study is to investigate the importance of entropy generation and thermal radiation on the patterns of velocity,isentropic lines,and temperature contours within a thermal energy storage dev...The objective of the current study is to investigate the importance of entropy generation and thermal radiation on the patterns of velocity,isentropic lines,and temperature contours within a thermal energy storage device filled with magnetic nanoencapsulated phase change materials(NEPCMs).The versatile finite element method(FEM)is implemented to numerically solve the governing equations.The effects of various parameters,including the viscosity parameter,ranging from 1 to 3,the thermal conductivity parameter,ranging from 1 to 3,the Rayleigh parameter,ranging from 102 to 3×10^(2),the radiation number,ranging from 0.1 to 0.5,the fusion temperature,ranging from 1.0 to 1.2,the volume fraction of NEPCMs,ranging from 2%to 6%,the Stefan number,ranging from 1 to 5,the magnetic number,ranging from 0.1 to 0.5,and the irreversibility parameter,ranging from 0.1 to 0.5,are examined in detail on the temperature contours,isentropic lines,heat capacity ratio,and velocity fields.Furthermore,the heat transfer rates at both the cold and hot walls are analyzed,and the findings are presented graphically.The results indicate that the time taken by the NEPCMs to transition from solid to liquid is prolonged inside the chamber region as the fusion temperatureθf increases.Additionally,the contours of the heat capacity ratio Cr decrease with the increase in the Stefan number Ste.展开更多
Electric furnace short process steelmaking is one of the most important steelmaking methods in the world today, and the waste heat recovery potential of electric furnace flue gas is huge.?The research on the recovery ...Electric furnace short process steelmaking is one of the most important steelmaking methods in the world today, and the waste heat recovery potential of electric furnace flue gas is huge.?The research on the recovery of electric furnace flue gas waste heat is of great significance. In order to make better use of this part of the heat,?in this paper, a compound cycle of nitrogen Brayton cycle as a first-order cycle and toluene transcritical Rankine cycle as a second-order cycle is proposed to recover waste heat from furnace flue gas in steelmaking process for power generation. A mathematical model was established with the net output power as the objective function and the initial expansion pressure, the final expansion pressure, the initial expansion temperature and the initial pressure of the second cycle as the independent variables. The effect of multivariate on the net output power of the waste heat power generation cycle is studied, and then, the optimal parameters of the compound cycle are determined. The results show that under the general electric furnace steelmaking process, the power generation efficiency of this new cycle can be increased by 21.02% compared with the conventional cycle.展开更多
Previously, we presented several empirical equations using the cosmic microwave background (CMB) temperature. Next, we propose an empirical equation for the fine-structure constant. Considering the compatibility among...Previously, we presented several empirical equations using the cosmic microwave background (CMB) temperature. Next, we propose an empirical equation for the fine-structure constant. Considering the compatibility among these empirical equations, the CMB temperature (T<sub>c</sub>) and gravitational constant (G) were calculated to be 2.726312 K and 6.673778 × 10<sup>−11</sup> m<sup>3</sup>∙kg<sup>−1</sup>∙s<sup>−2</sup>, respectively. Every equation could be explained in terms of the Compton length of an electron (λ<sub>e</sub>), the Compton length of a proton (λ<sub>p</sub>) and a. Furthermore, every equation could also be explained in terms of Avogadro’s number and the number of electrons in 1 C. However, the ratio of the gravitational force to the electric force cannot be uniquely determined when the unit of the Planck constant (Js) is changed. In this study, we showed that every equation can be described in terms of Planck constant. From the assumption of minimum mass, the ratio of gravitational force to electric force could be elucidated.展开更多
Heat generated by electric current in a quantum dot device contacting a phonon bath is studied using the non- equilibrium Green function technique. Spin-polarized current is generated owing to the Zeeman splitting of ...Heat generated by electric current in a quantum dot device contacting a phonon bath is studied using the non- equilibrium Green function technique. Spin-polarized current is generated owing to the Zeeman splitting of the dot level. The current's strength and the spin polarization are further manipulated by changing the frequency of an applied photon field and the ferromagnetism on the leads. We find that the associated heat by this spin- polarized current emerges even if the bias voltage is smaller than the phonon energy quanta and obvious negative differential of the heat generation develops when the photon frequency exceeds that of the phonon. It is also found that both the strength and the resonant peaks' position of the heat generation can be tuned by changing the value and the arrangement configurations of the magnetic moments of the two leads, and then provides an effective method to generate large spin-polarized current with weak heat. Such a result may be useful in designing low energy consumption spintronic devices.展开更多
During the hot summer season,using electricity systems increases the local anthropogenic heat emission,further increasing the temperature.Regarding anthropogenic heat sources,electric energy consumption,heat generatio...During the hot summer season,using electricity systems increases the local anthropogenic heat emission,further increasing the temperature.Regarding anthropogenic heat sources,electric energy consumption,heat generation,indoor and outdoor heat transfer,and exchange in buildings play a critical role in the change in the urban thermal environment.Therefore,the Weather Research and Forecasting(WRF)Model was applied in this study to investigate the heat generation from an indoor electricity system and its influence on the outdoor thermal environment.Through the building effect parameterization(BEP)of a multistorey urban canopy scheme,a building energy model(BEM)to increase the influence of indoor air conditioning on the electricity consumption system was proposed.In other words,the BEP+BEM urban canopy parameterization scheme was set.High temperatures and a summer heat wave were simulated as the background weather.The results show that using the BEP+BEM parameterization scheme of indoor and outdoor energy exchange in the WRF model can better simulate the air temperature near the surface layer on a sunny summer.During the day,the turning on the air conditioning and other electrical systems have no obvious effect on the air temperature near the surface layer in the city,whereas at night,the air temperature generally increases by 0.6℃,especially in densely populated areas,with a maximum temperature rise of approximately 1.2℃from 22:00 to 23:00.When the indoor air conditioning target temperature is adjusted to 25-27℃,the total energy release of the air conditioning system is reduced by 12.66%,and the temperature drops the most from 13:00 to 16:00,with an average of approximately 1℃.Further,the denser the building is,the greater the temperature drop.展开更多
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e...For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.展开更多
Experimental research of the heat and high-energy processes occurring in the cathode solid medium in the high voltage electric discharge system (electrolysis cell and glow discharge device) is presented. The experim...Experimental research of the heat and high-energy processes occurring in the cathode solid medium in the high voltage electric discharge system (electrolysis cell and glow discharge device) is presented. The experiments were carried out: Electrolysis in heavy water with a Pd cathode, electrolysis in light water with Ni and Pd cathodes, the glow discharge in deuterium with a Pd cathode. Excess heat was observed in experiments with high-voltage electrolysis (1,000 V or more). The experiments showed that the maximum excess heat power values of 5-8 W for glow discharge and 180-280 W for high-voltage electrolysis and heat efficiency up to 170% for glow discharge, and 800% for high-voltage electrolysis. The production of impurity nuclide yield showing a shift of up to a few per cent from natural isotopic abundances was detected by spark mass spectrometry and by secondary ionic mass spectrometry. The authors propose based on these experimental results a phenomenological model for low energy nuclear reaction.展开更多
We theoretically investigate the electricity storage/generation in a reversible solid oxide cell stack. The system heat is for the first time tentatively stored in a phase-change metal when the stack is operated to ge...We theoretically investigate the electricity storage/generation in a reversible solid oxide cell stack. The system heat is for the first time tentatively stored in a phase-change metal when the stack is operated to generate electricity in a fuel cell mode and then reused to store electricity in an electrolysis mode. The state of charge (H2 frication in cathode) effectively enhances the open circuit voltages (OCVs) while the system gas pressure in electrodes also increases the OCVs. On the other hand, a higher system pressure facilitates the species diffusion in electrodes that therefore accordingly improve electrode polarizations. With the aid of recycled system heat, the roundtrip efficiency reaches as high as 92% for the repeated electricity storage and generation.展开更多
To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and buil...To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and built.The heating cable is installed in the floor slab with a unit-rated power of 30 W/m.Twenty-four different schemes are worked out and tested,which include three kinds of composite floor structures and eight kinds of cable distances.The cable distances are 30,40,50,60,80,100,130,150 mm.The main affective factors of the thermal performance and their influencing regularity are discussed.The experimental results show that the system has good stability and reliability,and the ratio of the radiation heat-transfer rate to the gross heat-transfer rate is greater than 50%.When the floor structure and the cable distance are fixed,the gross heat-transfer rate of the upper floor surface has a maximum value at an optimal cable distance.Under the experimental conditions in this paper,the optimal cable distance is 50 mm.展开更多
Based on conservation of energy principle and heat flow data in China continent, the upper limit of 1.3 μW/m3 heat production is obtained for continental crust in China. Furthermore, using the data of heat flow and h...Based on conservation of energy principle and heat flow data in China continent, the upper limit of 1.3 μW/m3 heat production is obtained for continental crust in China. Furthermore, using the data of heat flow and helium isotope ratio of underground fluid, the heat productions of different tectonic units in China continent are estimated in range of 0.58-1.12 μW/m3 with a median of 0.85 μW/m3. Accordingly, the contents of U, Th and K20 in China crust are in ranges of 0.83-1.76 μg/g, 3.16-6.69 μg/g, and 1.0%-2.12%, respectively. These results indicate that the abundance of radioactive elements in the crust of China continent is much higher than that of Archean crust; and this fact implies China's continental crust is much evolved in chemical composition. Meanwhile, significant lateral variation of crustal composition is also exhibited among different tectonic units in China continent. The crust of eastern China is much enriched in incompatible elements such as U, Th and K than that of western China; and the crust of orogenic belts is more enriched than that of platform regions. It can also be inferred that the crusts of eastern China and orogenic belts are much felsic than those of western China and platform regions, respectively, derived from the positive correlation between the heat production and SiO2 content of bulk crust. This deduction is consistent with the results derived from the crustal seismic velocity data in China. According to the facts of the lower seismic velocity of China than the average value of global crust, and the higher heat production of China continent compared with global crust composition models published by previous studies, it is deduced that the average composition models of global continent crust by Rudnick and Fountain (1995), Rudnick and Gao (2003), Weaver and Tarney (1984), Shaw et al. (1986), and Wedepohl (1995) overestimate the abundance of incompatible elements such as U, Th and K of continental crust.展开更多
Arrhenius law implicates that only those molecules which possess the internal energy greater than the activation energy Ea can react. However, the internal energy will not be proportional to the gas temperature if the...Arrhenius law implicates that only those molecules which possess the internal energy greater than the activation energy Ea can react. However, the internal energy will not be proportional to the gas temperature if the specific heat ratio y and the gas constant R vary during chemical reaction processes. The varying y may affect significantly the chemical reaction rate calculated with the Arrhenius law under the constant γ assumption, which has been widely accepted in detonation and combustion simulations for many years. In this paper, the roles of variable γ and R in Arrhenius law applications are reconsidered, and their effects on the chemical reaction rate are demonstrated by simulating one- dimensional C-J and two-dimensional cellular detonations. A new overall one-step detonation model with variable γ and R is proposed to improve the Arrhenius law. Numerical experiments demonstrate that this improved Arrhenius law works well in predicting detonation phenomena with the numerical results being in good agreement with experimental data.展开更多
Due to the heat pipes’ transient conduction,phase change and fluid dynamics during cooling/heating with high frequency charging/discharging of batteries,it is crucial to investigate in depth the experimental dynamic ...Due to the heat pipes’ transient conduction,phase change and fluid dynamics during cooling/heating with high frequency charging/discharging of batteries,it is crucial to investigate in depth the experimental dynamic thermal characteristics in such complex heat transfer processes for more accurate thermal analysis and design of a BTMS. In this paper,the use of ultra?thin micro heat pipe(UMHP) for thermal management of a lithium?ion battery pack in EVs is explored by experiments to reveal the cooling/heating characteristics of the UMHP pack. The cooling performance is evaluated under di erent constant discharging and transient heat inputs conditions. And the heating e ciency is assessed under several sub?zero temperatures through heating films with/without UMHPs. Results show that the pro?posed UMHP BTMS with forced convection can keep the maximum temperature of the pack below 40 °C under 1 ~ 3 C discharging,and e ectively reduced the instant temperature increases and minimize the temperature fluctuation of the pack during transient federal urban driving schedule(FUDS) road conditions. Experimental data also indicate that heating films stuck on the fins of UMHPs brought about adequate high heating e ciency comparing with that stuck on the surface of cells under the same heating power,but has more convenient maintenance and less cost for the BTMS. The experimental dynamic temperature characteristics of UMHP which is found to be a high?e cient and low?energy consumption cooling/heating method for BTMSs,can be performed to guide thermal analysis and optimiza?tion of heat pipe BTMSs.展开更多
The K_xNa_((1-x))NbO_3(x=0.45, 0.46, 0.47, 0.48, 0.49, 0.50) lead-free piezoelectric ceramics was fabricated by conventional solid-state sintering method. It was found that the ratio of alkaline metal would affect the...The K_xNa_((1-x))NbO_3(x=0.45, 0.46, 0.47, 0.48, 0.49, 0.50) lead-free piezoelectric ceramics was fabricated by conventional solid-state sintering method. It was found that the ratio of alkaline metal would affect the microstructure, bulk density, and optimum sintering temperatures of ceramics. Meanwhile, the electrical properties were also influenced by modulating the K/Na ratio, exhibiting corresponding composition-dependent properties. The optimum electrical properties of K_xNa_((1-x))NbO_3 such as piezoelectric constant d_(33) = 115 pC/N, mechanical quality factor Q_m = 20, Curie temperature Tc = 365 ~oC, ε_(33)~T/ε_0= 588.1, dielectric loss tan δ = 0.024, bulk density(ρ) = 3.08 g/cm^3, remnant polarization(P_r) = 8.87 μC/cm^2 and coercive field(Ec) = 13.79 kV/cm were obtained at x = 0.46.展开更多
The effect of heat treatment on electrical conductivity of Cu alloy containing Ni, Al, and rare earth(Ce) alloying elements was studied by metallographic microscope, TEM, SEM/EDS and conductance instrument. The result...The effect of heat treatment on electrical conductivity of Cu alloy containing Ni, Al, and rare earth(Ce) alloying elements was studied by metallographic microscope, TEM, SEM/EDS and conductance instrument. The results indicate that heat treatment can improve the electrical conductivity of the material due to the reducing of the solid solution of Cr element in Cu matrix. The better conductivity was obtained after getting solid solution at 980 ℃ for 1 h, and then aging at 500 ℃ for 4 h.展开更多
Numerical analysis was performed to investigate flow and heat transfer characteristics in spiral coiled tube heat exchanger. Radius of curvature of the spiral coiled tube was gradually increased as total rotating angl...Numerical analysis was performed to investigate flow and heat transfer characteristics in spiral coiled tube heat exchanger. Radius of curvature of the spiral coiled tube was gradually increased as total rotating angle reached 12n. As the varying radius of curvature became a dominant flow parameter, three-dimensional flow analysis was performed to this flow together with different Reynolds numbers while constant wall heat flux condition was set in thermal field. From the analysis, centrifugal force due to curvature effect is found to have significant role in behavior of pressure drop and heat transfer. The centrifugal force enhances pressure drop and heat transfer to have generally higher values in the spiral coiled tube than those in the straight tube. Even then, friction factor and Nusselt number are found to follow the proportionality with square root of the Dean number. Individual effect of flow parameters of Reynolds number and curvature ratio was investigated and effect of Reynolds number is found to be stronger than that of curvature effect.展开更多
Heat transfer and entropy generation of developing laminar forced convection flow of water-Al_2O_3 nanofluid in a concentric annulus with constant heat flux on the walls is investigated numerically. In order to determ...Heat transfer and entropy generation of developing laminar forced convection flow of water-Al_2O_3 nanofluid in a concentric annulus with constant heat flux on the walls is investigated numerically. In order to determine entropy generation of fully developed flow, two approaches are employed and it is shown that only one of these methods can provide appropriate results for flow inside annuli. The effects of concentration of nanoparticles, Reynolds number and thermal boundaries on heat transfer enhancement and entropy generation of developing laminar flow inside annuli with different radius ratios and same cross sectional areas are studied. The results show that radius ratio is a very important decision parameter of an annular heat exchanger such that in each Re, there is an optimum radius ratio to maximize Nu and minimize entropy generation. Moreover, the effect of nanoparticles concentration on heat transfer enhancement and minimizing entropy generation is stronger at higher Reynolds.展开更多
基金supported by Shanghai Rising-Star Program(No.22QA1403900)the National Natural Science Foundation of China(No.71804106)the Noncarbon Energy Conversion and Utilization Institute under the Shanghai Class IV Peak Disciplinary Development Program.
文摘Cascading faults have been identified as the primary cause of multiple power outages in recent years.With the emergence of integrated energy systems(IES),the conventional approach to analyzing power grid cascading faults is no longer appropriate.A cascading fault analysis method considering multi-energy coupling characteristics is of vital importance.In this study,an innovative analysis method for cascading faults in integrated heat and electricity systems(IHES)is proposed.It considers the degradation characteristics of transmission and energy supply com-ponents in the system to address the impact of component aging on cascading faults.Firstly,degradation models for the current carrying capacity of transmission lines,the water carrying capacity and insulation performance of thermal pipelines,as well as the performance of energy supply equipment during aging,are developed.Secondly,a simulation process for cascading faults in the IHES is proposed.It utilizes an overload-dominated development model to predict the propagation path of cascading faults while also considering network islanding,electric-heating rescheduling,and load shedding.The propagation of cascading faults is reflected in the form of fault chains.Finally,the results of cascading faults under different aging levels are analyzed through numerical examples,thereby verifying the effectiveness and rationality of the proposed model and method.
基金This work was supported by the Science and Technology Program of State Grid Corporation of China(522300190008).
文摘Combined heat and electricity operation with variable mass flow rates promotes flexibility,economy,and sustainability through synergies between electric power systems(EPSs)and district heating systems(DHSs).Such combined operation presents a highly nonlinear and nonconvex optimization problem,mainly due to the bilinear terms in the heat flow model—that is,the product of the mass flow rate and the nodal temperature.Existing methods,such as nonlinear optimization,generalized Benders decomposition,and convex relaxation,still present challenges in achieving a satisfactory performance in terms of solution quality and computational efficiency.To resolve this problem,we herein first reformulate the district heating network model through an equivalent transformation and variable substitution.The reformulated model has only one set of nonconvex constraints with reduced bilinear terms,and the remaining constraints are linear.Such a reformulation not only ensures optimality,but also accelerates the solving process.To relax the remaining bilinear constraints,we then apply McCormick envelopes and obtain an objective lower bound of the reformulated model.To improve the quality of the McCormick relaxation,we employ a piecewise McCormick technique that partitions the domain of one of the variables of the bilinear terms into several disjoint regions in order to derive strengthened lower and upper bounds of the partitioned variables.We propose a heuristic tightening method to further constrict the strengthened bounds derived from the piecewise McCormick technique and recover a nearby feasible solution.Case studies show that,compared with the interior point method and the method implemented in a global bilinear solver,the proposed tightening McCormick method quickly solves the heat–electricity operation problem with an acceptable feasibility check and optimality.
基金the National Natural Science Foundation of China(Nos.52368032 and 51808272)the China Postdoctoral Science Foundation(No.2023M741455)+1 种基金the Tianyou Youth Talent Lift Program of Lanzhou Jiaotong UniversityGansu Province Youth Talent Support Project(No.GXH20210611-10)。
文摘The effects of the water-cement ratio and the molding temperature on the hydration heat of cement were investigated with semi-adiabatic calorimetry.The specimens were prepared with water-cement ratios of 0.31,0.38,and 0.45,and the molding temperature was specified at 10 and 20℃.The experimental results show that,as the water-binder ratio increases,the value of the second temperature peak on the temperature curve of the cement paste decreases,and the age at which the peak appears is delayed.The higher the water-cement ratio,the higher the hydration heat release in the early period of cement hydration,but this trend reverses in the late period.There are intersection points of the total hydration heat curve of the cement pastes under the influence of the water-cement ratio,and this law can be observed at both molding temperatures.With the increase in the molding temperature,the age of the second temperature peak on the temperature curve of the cement paste will advance,but the temperature peak will decrease.The higher the molding temperature,the earlier the acceleration period of the cement hydration began,and the larger the hydration heat of the cement in the early stage,but the smaller the total heat in the late period.A subsection function calculation model of the hydration heat,which was based on the existing models,was proposed in order to predict the heat of the hydration of the concrete.
基金supported in part by the National Key Research and Development Program of China under Grant 2021YFB1600200in part by the Shaanxi Province Postdoctoral Research Project under grant 2023BSHEDZZ223+3 种基金in part by the Fundamental Research Funds for the Central Universities,CHD,under grant 300102383101in part by the Shaanxi Province Qinchuangyuan High-Level Innovation and Entrepreneurship Talent Project under grant QCYRCXM-2023-112the Key Research and Development Program of Shaanxi Province under grant 2024GX-YBXM-442in part by the National Natural Science Foundation of China under grand 62373224.
文摘The significant decrease in battery performance at low temperatures is one of the critical challenges that electric vehicles(EVs)face,thereby affecting the penetration rate in cold regions.Alternating current(AC)heating has attracted widespread attention due to its low energy consumption and uniform heating advantages.This paper introduces the recent advances in AC heating from the perspective of practical EV applications.First,the performance degradation of EVs in low-temperature environments is introduced briefly.The concept of AC heating and its research methods are provided.Then,the effects of various AC heating methods on battery heating performance are reviewed.Based on existing studies,the main factors that affect AC heating performance are analyzed.Moreover,various heating circuits based on EVs are categorized,and their cost,size,complexity,efficiency,reliability,and heating rate are elaborated and compared.The evolution of AC heaters is presented,and the heaters used in brand vehicles are sorted out.Finally,the perspectives and challenges of AC heating are discussed.This paper can guide the selection of heater implementation methods and the optimization of heating effects for future EV applications.
文摘The objective of the current study is to investigate the importance of entropy generation and thermal radiation on the patterns of velocity,isentropic lines,and temperature contours within a thermal energy storage device filled with magnetic nanoencapsulated phase change materials(NEPCMs).The versatile finite element method(FEM)is implemented to numerically solve the governing equations.The effects of various parameters,including the viscosity parameter,ranging from 1 to 3,the thermal conductivity parameter,ranging from 1 to 3,the Rayleigh parameter,ranging from 102 to 3×10^(2),the radiation number,ranging from 0.1 to 0.5,the fusion temperature,ranging from 1.0 to 1.2,the volume fraction of NEPCMs,ranging from 2%to 6%,the Stefan number,ranging from 1 to 5,the magnetic number,ranging from 0.1 to 0.5,and the irreversibility parameter,ranging from 0.1 to 0.5,are examined in detail on the temperature contours,isentropic lines,heat capacity ratio,and velocity fields.Furthermore,the heat transfer rates at both the cold and hot walls are analyzed,and the findings are presented graphically.The results indicate that the time taken by the NEPCMs to transition from solid to liquid is prolonged inside the chamber region as the fusion temperatureθf increases.Additionally,the contours of the heat capacity ratio Cr decrease with the increase in the Stefan number Ste.
文摘Electric furnace short process steelmaking is one of the most important steelmaking methods in the world today, and the waste heat recovery potential of electric furnace flue gas is huge.?The research on the recovery of electric furnace flue gas waste heat is of great significance. In order to make better use of this part of the heat,?in this paper, a compound cycle of nitrogen Brayton cycle as a first-order cycle and toluene transcritical Rankine cycle as a second-order cycle is proposed to recover waste heat from furnace flue gas in steelmaking process for power generation. A mathematical model was established with the net output power as the objective function and the initial expansion pressure, the final expansion pressure, the initial expansion temperature and the initial pressure of the second cycle as the independent variables. The effect of multivariate on the net output power of the waste heat power generation cycle is studied, and then, the optimal parameters of the compound cycle are determined. The results show that under the general electric furnace steelmaking process, the power generation efficiency of this new cycle can be increased by 21.02% compared with the conventional cycle.
文摘Previously, we presented several empirical equations using the cosmic microwave background (CMB) temperature. Next, we propose an empirical equation for the fine-structure constant. Considering the compatibility among these empirical equations, the CMB temperature (T<sub>c</sub>) and gravitational constant (G) were calculated to be 2.726312 K and 6.673778 × 10<sup>−11</sup> m<sup>3</sup>∙kg<sup>−1</sup>∙s<sup>−2</sup>, respectively. Every equation could be explained in terms of the Compton length of an electron (λ<sub>e</sub>), the Compton length of a proton (λ<sub>p</sub>) and a. Furthermore, every equation could also be explained in terms of Avogadro’s number and the number of electrons in 1 C. However, the ratio of the gravitational force to the electric force cannot be uniquely determined when the unit of the Planck constant (Js) is changed. In this study, we showed that every equation can be described in terms of Planck constant. From the assumption of minimum mass, the ratio of gravitational force to electric force could be elucidated.
基金Supported by the National Natural Science Foundation of China under Grant No 61274101
文摘Heat generated by electric current in a quantum dot device contacting a phonon bath is studied using the non- equilibrium Green function technique. Spin-polarized current is generated owing to the Zeeman splitting of the dot level. The current's strength and the spin polarization are further manipulated by changing the frequency of an applied photon field and the ferromagnetism on the leads. We find that the associated heat by this spin- polarized current emerges even if the bias voltage is smaller than the phonon energy quanta and obvious negative differential of the heat generation develops when the photon frequency exceeds that of the phonon. It is also found that both the strength and the resonant peaks' position of the heat generation can be tuned by changing the value and the arrangement configurations of the magnetic moments of the two leads, and then provides an effective method to generate large spin-polarized current with weak heat. Such a result may be useful in designing low energy consumption spintronic devices.
基金supported by Incubation Project of State Grid Jiangsu Electric Power Company“Research and application of key technology of intelligent forecasting and warning for electric power meteorological public service platform”(JF2021045).
文摘During the hot summer season,using electricity systems increases the local anthropogenic heat emission,further increasing the temperature.Regarding anthropogenic heat sources,electric energy consumption,heat generation,indoor and outdoor heat transfer,and exchange in buildings play a critical role in the change in the urban thermal environment.Therefore,the Weather Research and Forecasting(WRF)Model was applied in this study to investigate the heat generation from an indoor electricity system and its influence on the outdoor thermal environment.Through the building effect parameterization(BEP)of a multistorey urban canopy scheme,a building energy model(BEM)to increase the influence of indoor air conditioning on the electricity consumption system was proposed.In other words,the BEP+BEM urban canopy parameterization scheme was set.High temperatures and a summer heat wave were simulated as the background weather.The results show that using the BEP+BEM parameterization scheme of indoor and outdoor energy exchange in the WRF model can better simulate the air temperature near the surface layer on a sunny summer.During the day,the turning on the air conditioning and other electrical systems have no obvious effect on the air temperature near the surface layer in the city,whereas at night,the air temperature generally increases by 0.6℃,especially in densely populated areas,with a maximum temperature rise of approximately 1.2℃from 22:00 to 23:00.When the indoor air conditioning target temperature is adjusted to 25-27℃,the total energy release of the air conditioning system is reduced by 12.66%,and the temperature drops the most from 13:00 to 16:00,with an average of approximately 1℃.Further,the denser the building is,the greater the temperature drop.
基金This work was supported by the National Key Research and Development Program of China(No.2019YFE0193200 KY202001)Science and Technology Planning Project of Beijing(No.Z201100008320001 KY191004).
文摘For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.
文摘Experimental research of the heat and high-energy processes occurring in the cathode solid medium in the high voltage electric discharge system (electrolysis cell and glow discharge device) is presented. The experiments were carried out: Electrolysis in heavy water with a Pd cathode, electrolysis in light water with Ni and Pd cathodes, the glow discharge in deuterium with a Pd cathode. Excess heat was observed in experiments with high-voltage electrolysis (1,000 V or more). The experiments showed that the maximum excess heat power values of 5-8 W for glow discharge and 180-280 W for high-voltage electrolysis and heat efficiency up to 170% for glow discharge, and 800% for high-voltage electrolysis. The production of impurity nuclide yield showing a shift of up to a few per cent from natural isotopic abundances was detected by spark mass spectrometry and by secondary ionic mass spectrometry. The authors propose based on these experimental results a phenomenological model for low energy nuclear reaction.
文摘We theoretically investigate the electricity storage/generation in a reversible solid oxide cell stack. The system heat is for the first time tentatively stored in a phase-change metal when the stack is operated to generate electricity in a fuel cell mode and then reused to store electricity in an electrolysis mode. The state of charge (H2 frication in cathode) effectively enhances the open circuit voltages (OCVs) while the system gas pressure in electrodes also increases the OCVs. On the other hand, a higher system pressure facilitates the species diffusion in electrodes that therefore accordingly improve electrode polarizations. With the aid of recycled system heat, the roundtrip efficiency reaches as high as 92% for the repeated electricity storage and generation.
文摘To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and built.The heating cable is installed in the floor slab with a unit-rated power of 30 W/m.Twenty-four different schemes are worked out and tested,which include three kinds of composite floor structures and eight kinds of cable distances.The cable distances are 30,40,50,60,80,100,130,150 mm.The main affective factors of the thermal performance and their influencing regularity are discussed.The experimental results show that the system has good stability and reliability,and the ratio of the radiation heat-transfer rate to the gross heat-transfer rate is greater than 50%.When the floor structure and the cable distance are fixed,the gross heat-transfer rate of the upper floor surface has a maximum value at an optimal cable distance.Under the experimental conditions in this paper,the optimal cable distance is 50 mm.
基金supported by the National Natural Science Foundation of China (Grants Nos. 40376013, 40572128, and 40104003)
文摘Based on conservation of energy principle and heat flow data in China continent, the upper limit of 1.3 μW/m3 heat production is obtained for continental crust in China. Furthermore, using the data of heat flow and helium isotope ratio of underground fluid, the heat productions of different tectonic units in China continent are estimated in range of 0.58-1.12 μW/m3 with a median of 0.85 μW/m3. Accordingly, the contents of U, Th and K20 in China crust are in ranges of 0.83-1.76 μg/g, 3.16-6.69 μg/g, and 1.0%-2.12%, respectively. These results indicate that the abundance of radioactive elements in the crust of China continent is much higher than that of Archean crust; and this fact implies China's continental crust is much evolved in chemical composition. Meanwhile, significant lateral variation of crustal composition is also exhibited among different tectonic units in China continent. The crust of eastern China is much enriched in incompatible elements such as U, Th and K than that of western China; and the crust of orogenic belts is more enriched than that of platform regions. It can also be inferred that the crusts of eastern China and orogenic belts are much felsic than those of western China and platform regions, respectively, derived from the positive correlation between the heat production and SiO2 content of bulk crust. This deduction is consistent with the results derived from the crustal seismic velocity data in China. According to the facts of the lower seismic velocity of China than the average value of global crust, and the higher heat production of China continent compared with global crust composition models published by previous studies, it is deduced that the average composition models of global continent crust by Rudnick and Fountain (1995), Rudnick and Gao (2003), Weaver and Tarney (1984), Shaw et al. (1986), and Wedepohl (1995) overestimate the abundance of incompatible elements such as U, Th and K of continental crust.
文摘Arrhenius law implicates that only those molecules which possess the internal energy greater than the activation energy Ea can react. However, the internal energy will not be proportional to the gas temperature if the specific heat ratio y and the gas constant R vary during chemical reaction processes. The varying y may affect significantly the chemical reaction rate calculated with the Arrhenius law under the constant γ assumption, which has been widely accepted in detonation and combustion simulations for many years. In this paper, the roles of variable γ and R in Arrhenius law applications are reconsidered, and their effects on the chemical reaction rate are demonstrated by simulating one- dimensional C-J and two-dimensional cellular detonations. A new overall one-step detonation model with variable γ and R is proposed to improve the Arrhenius law. Numerical experiments demonstrate that this improved Arrhenius law works well in predicting detonation phenomena with the numerical results being in good agreement with experimental data.
基金Supported by National Natural Science Foundation of China(Grant No.51775193)Guangdong Provincial Science and Technology Planning Project of China(Grant Nos.2014B010125001,2014B010106002,2016A050503021)Guangzhou Municipal Science and Technology Planning Project of China(Grant No.201707020045)
文摘Due to the heat pipes’ transient conduction,phase change and fluid dynamics during cooling/heating with high frequency charging/discharging of batteries,it is crucial to investigate in depth the experimental dynamic thermal characteristics in such complex heat transfer processes for more accurate thermal analysis and design of a BTMS. In this paper,the use of ultra?thin micro heat pipe(UMHP) for thermal management of a lithium?ion battery pack in EVs is explored by experiments to reveal the cooling/heating characteristics of the UMHP pack. The cooling performance is evaluated under di erent constant discharging and transient heat inputs conditions. And the heating e ciency is assessed under several sub?zero temperatures through heating films with/without UMHPs. Results show that the pro?posed UMHP BTMS with forced convection can keep the maximum temperature of the pack below 40 °C under 1 ~ 3 C discharging,and e ectively reduced the instant temperature increases and minimize the temperature fluctuation of the pack during transient federal urban driving schedule(FUDS) road conditions. Experimental data also indicate that heating films stuck on the fins of UMHPs brought about adequate high heating e ciency comparing with that stuck on the surface of cells under the same heating power,but has more convenient maintenance and less cost for the BTMS. The experimental dynamic temperature characteristics of UMHP which is found to be a high?e cient and low?energy consumption cooling/heating method for BTMSs,can be performed to guide thermal analysis and optimiza?tion of heat pipe BTMSs.
基金Funded by the National Natural Science Foundation of China(No.51302199)Key Natural Science Foundation of Hubei Province of China for Distinguished Yong Scholars(No.2014CFA044)+2 种基金Cultivation Plan for Science and Technology Talents of Wu Han City(No.2014072704011253)MOST Special Fund from the State Key Laboratory of Geological Process and Mineral Resources(No.MSFGPMR201204)Natural Science Foundation of Hubei Province(No.2014CFB809)
文摘The K_xNa_((1-x))NbO_3(x=0.45, 0.46, 0.47, 0.48, 0.49, 0.50) lead-free piezoelectric ceramics was fabricated by conventional solid-state sintering method. It was found that the ratio of alkaline metal would affect the microstructure, bulk density, and optimum sintering temperatures of ceramics. Meanwhile, the electrical properties were also influenced by modulating the K/Na ratio, exhibiting corresponding composition-dependent properties. The optimum electrical properties of K_xNa_((1-x))NbO_3 such as piezoelectric constant d_(33) = 115 pC/N, mechanical quality factor Q_m = 20, Curie temperature Tc = 365 ~oC, ε_(33)~T/ε_0= 588.1, dielectric loss tan δ = 0.024, bulk density(ρ) = 3.08 g/cm^3, remnant polarization(P_r) = 8.87 μC/cm^2 and coercive field(Ec) = 13.79 kV/cm were obtained at x = 0.46.
文摘The effect of heat treatment on electrical conductivity of Cu alloy containing Ni, Al, and rare earth(Ce) alloying elements was studied by metallographic microscope, TEM, SEM/EDS and conductance instrument. The results indicate that heat treatment can improve the electrical conductivity of the material due to the reducing of the solid solution of Cr element in Cu matrix. The better conductivity was obtained after getting solid solution at 980 ℃ for 1 h, and then aging at 500 ℃ for 4 h.
基金supported by the Second Stage of Brain Korea 21 Projects,Korea
文摘Numerical analysis was performed to investigate flow and heat transfer characteristics in spiral coiled tube heat exchanger. Radius of curvature of the spiral coiled tube was gradually increased as total rotating angle reached 12n. As the varying radius of curvature became a dominant flow parameter, three-dimensional flow analysis was performed to this flow together with different Reynolds numbers while constant wall heat flux condition was set in thermal field. From the analysis, centrifugal force due to curvature effect is found to have significant role in behavior of pressure drop and heat transfer. The centrifugal force enhances pressure drop and heat transfer to have generally higher values in the spiral coiled tube than those in the straight tube. Even then, friction factor and Nusselt number are found to follow the proportionality with square root of the Dean number. Individual effect of flow parameters of Reynolds number and curvature ratio was investigated and effect of Reynolds number is found to be stronger than that of curvature effect.
文摘Heat transfer and entropy generation of developing laminar forced convection flow of water-Al_2O_3 nanofluid in a concentric annulus with constant heat flux on the walls is investigated numerically. In order to determine entropy generation of fully developed flow, two approaches are employed and it is shown that only one of these methods can provide appropriate results for flow inside annuli. The effects of concentration of nanoparticles, Reynolds number and thermal boundaries on heat transfer enhancement and entropy generation of developing laminar flow inside annuli with different radius ratios and same cross sectional areas are studied. The results show that radius ratio is a very important decision parameter of an annular heat exchanger such that in each Re, there is an optimum radius ratio to maximize Nu and minimize entropy generation. Moreover, the effect of nanoparticles concentration on heat transfer enhancement and minimizing entropy generation is stronger at higher Reynolds.