期刊文献+
共找到25,514篇文章
< 1 2 250 >
每页显示 20 50 100
Vibration attenuation performance of wind turbine tower using a prestressed tuned mass damper under seismic excitation
1
作者 Lei Zhenbo Liu Gang +1 位作者 Wang Hui Hui Yi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期511-524,共14页
With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cau... With the rapid development of large megawatt wind turbines,the operation environment of wind turbine towers(WTTs)has become increasingly complex.In particular,seismic excitation can create a resonance response and cause excessive vibration of the WTT.To investigate the vibration attenuation performance of the WTT under seismic excitations,a novel passive vibration control device,called a prestressed tuned mass damper(PS-TMD),is presented in this study.First,a mathematical model is established based on structural dynamics under seismic excitation.Then,the mathematical analytical expression of the dynamic coefficient is deduced,and the parameter design method is obtained by system tuning optimization.Next,based on a theoretical analysis and parameter design,the numerical results showed that the PS-TMD was able to effectively mitigate the resonance under the harmonic basal acceleration.Finally,the time-history analysis method is used to verify the effectiveness of the traditional pendulum tuned mass damper(PTMD)and the novel PS-TMD device,and the results indicate that the vibration attenuation performance of the PS-TMD is better than the PTMD.In addition,the PS-TMD avoids the nonlinear effect due to the large oscillation angle,and has the potential to dissipate hysteretic energy under seismic excitation. 展开更多
关键词 wind turbine tower prestressed tuned mass damper vibration control seismic excitation numerical simulation
下载PDF
Comparison between seismic analysis of twisting and regular 52-story towers considering soil-structure interaction
2
作者 Mohamed Naguib Abouelsaad Mohammed Shaaban +1 位作者 Salah El Bagalaty Mohamed E.El Madawy 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第3期663-675,共13页
A dynamic analysis of both twisting and regular towers is carried out to determine the results of considering soil-structure interaction(SSI)on high-rise buildings.In addition,the difference between the seismic perfor... A dynamic analysis of both twisting and regular towers is carried out to determine the results of considering soil-structure interaction(SSI)on high-rise buildings.In addition,the difference between the seismic performance of using twisting towers over regular ones is investigated.The twisting tower is a simulation of the Evolution Tower(Moscow).The towers’skeletons consist of RC elements and rest on a reinforced concrete piled-raft foundation.The soil model is considered as multi-layered with the same soil properties as the zone chosen for the analysis(New Mansoura City,Egypt).The only difference between both towers is their shape in elevation.The whole system is modelled and analyzed in a single step as one full 3D model,which is known as the direct approach in SSI.All analyses are carried out using finite-element software(Midas GTS NX).Dynamic output responses due to three records of seismic loads are proposed and presented in some graphs.Based on the results,it is concluded that SSI has a considerable effect on the dynamic response of tall buildings mainly because of the foundation flexibility,as it leads to lengthening the vibration period,increasing the story drift and the base shear for both cases. 展开更多
关键词 soil-structure interaction seismic analysis twisting towers base shear story drift finite element method Midas GTS NX
下载PDF
Research on Transmission Line Tower Tilting and Foundation State Monitoring Technology Based onMulti-Sensor Cooperative Detection and Correction
3
作者 Guangxin Zhang Minghui Liu +4 位作者 Shichao Cheng Minzhen Wang Changshun Zhao Hongdan Zhao Gaiming Zhong 《Energy Engineering》 EI 2024年第1期169-185,共17页
The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi... The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation. 展开更多
关键词 Transmission line tower tilting MULTI-SENSOR foundation state monitoring collaborative detection
下载PDF
Impact of Crosswind on Steady-State and Dynamic Performance of Natural Draft Dry Cooling Tower Group:A Numerical Analysis
4
作者 Xuhui Jiang Xi Zhang +4 位作者 Song Wang Ruiqiong Wang Peng Zou Jingzhou Lu Xiaoxiao Li 《Frontiers in Heat and Mass Transfer》 EI 2024年第1期193-216,共24页
This study investigates the performance of a natural draft dry cooling tower group in crosswind conditions through numerical analysis.A comprehensive three-dimensional model is developed to analyze the steady-state an... This study investigates the performance of a natural draft dry cooling tower group in crosswind conditions through numerical analysis.A comprehensive three-dimensional model is developed to analyze the steady-state and dynamic behavior of the towers.The impact of wind speed and direction on heat rejection capacity and flow patterns is examined.Results indicate that crosswinds negatively affect the overall heat transfer capacity,with higher crosswind speeds leading to decreased heat transfer.Notably,wind direction plays a significant role,particularly at 0°.Moreover,tower response time increases with higher crosswind speeds due to increased turbulence and the formation of vortices.The response times are generally similar for wind directions of 45°and 90°,but differ when facing 0,where the leeward tower exhibits a shorter response time compared to the windward tower.These findings provide valuable insights into the performance of natural draft dry cooling tower groups under crosswind conditions,which can inform the design and operation of similar systems in practical applications. 展开更多
关键词 Natural draft dry cooling tower group CROSSWIND dynamic characteristics
下载PDF
Design Optimization of a Lattice Tower: Structure and Foundations
5
作者 Cossi Télesphore Nounangnonhou Guy Clarence Semassou +1 位作者 Kossoun Alain Tossa Noémie Sintondji 《Open Journal of Applied Sciences》 2024年第2期483-493,共11页
Produced in power plants, electrical energy is transported to places of consumption via the electricity network. At the heart of this network are the supports that allow electricity to be efficiently transported over ... Produced in power plants, electrical energy is transported to places of consumption via the electricity network. At the heart of this network are the supports that allow electricity to be efficiently transported over long distances, guaranteeing the security and supply of energy to the various centers of use. In the construction of a line, supports occupy an important part in terms of safety and construction cost. It is therefore essential to optimize their use to reduce the cost of transmission lines. This work addresses this problem, which focuses on the optimal utilization of X-lattice towers in the construction of overhead power lines. The challenge is to reconcile the search for optimal cost and respect for the design, resistance and service constraints of the structure. To do this, a parameter having a strong correlation with the weight, foundation and construction cost of the X-lattice tower for 161 kV lines is determined as an important cost variable. This parameter is the wheelbase of the towers. The junction point between the structure and the foundations is obtained by measuring the forces at the base of the tower following the lowering of the loads. These efforts make it possible to size foundations which are of the inverted or isolated sole type. The results obtained reveal that from 8 meters in width, the wheelbase gradually changes until the optimum is obtained at 6.29 meters. With this wheelbase, the production cost is optimal. It clearly emerges from this study that the construction of lattice pylons with a wheelbase of approximately 6.29 meters makes it possible to optimize the cost of construction of 161 kV lines in the Republic of Benin. 展开更多
关键词 Lattice tower WHEELBASE COST OPTIMIZATION FOUNDATION
下载PDF
Tower Semiconductor Acquisition: Advancing Intel’s Presence in the Global Market
6
作者 CHEN Kangmin 《Management Studies》 2024年第1期33-41,共9页
This paper delves into the economic event surrounding Intel Corporation’s high-profile acquisition of Tower Corporation.It aims to investigate the reasons behind Intel’s decision to acquire Tower,employ the SWOT ana... This paper delves into the economic event surrounding Intel Corporation’s high-profile acquisition of Tower Corporation.It aims to investigate the reasons behind Intel’s decision to acquire Tower,employ the SWOT analysis method to evaluate the event,and examine its impact on relevant stakeholders.The findings indicate that Intel’s acquisition of Tower was driven by objectives such as strengthening business areas,expanding market share,technological innovation and development,and future development strategy.Through the application of SWOT analysis,it becomes evident that the advantages of the acquisition lie in strengthening technical capabilities and expanding business segments,while simultaneously facing challenges such as integration complexities and pressure.The significance of this paper lies in gaining a comprehensive understanding of the strategic motivations and potential impacts associated with corporate acquisitions,thereby providing valuable insights for decision-making processes.The innovation lies in the comprehensive utilization of SWOT analysis to holistically evaluate the acquisition event,enabling a thorough assessment of its various aspects.For government and policymakers,they should strength regulation of corporate takeovers to ensure fair and transparent market competition,provide support and incentives,and strength cooperation to develop common policies and norms.As for enterprises,it is advised that strategic planning and comprehensive consideration should be formulated and carried out when making acquisitions.Also,stakeholders should actively participate in and monitor the process of corporate acquisition discussion and decision-making,and strengthen cooperation to ensure fair competition,maximizing the interests of all parties. 展开更多
关键词 intel corporation tower corporation ACQUISITION strategic motivation potential impacts SWOT analysis COOPERATION
下载PDF
Evaluation of Driver-Induced Human Errors in Smart Construction Tower Crane Operations Based on DEMATEL-ISM-MICMAC
7
作者 Jiahao Wang Wen Si 《Journal of Applied Mathematics and Physics》 2024年第4期1541-1556,共16页
With the advent of Industry 4.0, smart construction sites have seen significant development in China. However, accidents involving digitized tower cranes continue to be a persistent issue. Among the contributing facto... With the advent of Industry 4.0, smart construction sites have seen significant development in China. However, accidents involving digitized tower cranes continue to be a persistent issue. Among the contributing factors, human unsafe behavior stands out as a primary cause for these incidents. This study aims to assess the human reliability of tower crane operations on smart construction sites. To proactively enhance safety measures, the research employs text mining techniques (TF-IDF-Truncated SVD-Complement NB) to identify patterns of human errors among tower crane operators. Building upon the SHEL model, the study categorizes behavioral factors affecting human reliability in the man-machine interface, leading to the establishment of the Performance Shaping Factors (PSFs) system. Furthermore, the research constructs an error impact indicator system for the intelligent construction site tower crane operator interface. Using the DEMATEL method, it analyzes the significance of various factors influencing human errors in tower crane operations. Additionally, the ISM-MICMAC method is applied to unveil the hierarchical relationships and driving-dependent connections among these influencing factors. The findings indicate that personal state, operating procedures, and physical environment directly impact human errors, while personal capability, technological environment, and one fundamental organizational management factor contribute indirectly. . 展开更多
关键词 Text Mining DEMATEL-ISM-MICMAC Performance Shaping Factors Smart Construction tower Crane Operator
下载PDF
Tower节点集上的极小次数牛顿基 被引量:2
8
作者 陈涛 董天 张树功 《吉林大学学报(理学版)》 CAS CSCD 北大核心 2007年第6期932-934,共3页
将关于张量积格点的lower子集上Lagrange插值问题的极小次数牛顿基推广到tower节点子集上.解决了二元Lagrange插值牛顿基问题,把tower节点集的概念推广到任意多维情形,以三维为例给出了相应的Lagrange插值极小次数牛顿基,并给出了计算三... 将关于张量积格点的lower子集上Lagrange插值问题的极小次数牛顿基推广到tower节点子集上.解决了二元Lagrange插值牛顿基问题,把tower节点集的概念推广到任意多维情形,以三维为例给出了相应的Lagrange插值极小次数牛顿基,并给出了计算三维tower节点集合消逝理想的约化Grbner基的快速算法. 展开更多
关键词 tower节点集 多元多项式插值 极小次数牛顿基
下载PDF
Adsorption Properties of Adsorption Tower Filled with Calcium Superphosphate on NH_3 Emitted from Composting System of Animal Wastes 被引量:2
9
作者 吕丹丹 种云霄 +4 位作者 吴启堂 吴根义 贺德春 丘锦荣 许振成 《Agricultural Science & Technology》 CAS 2012年第9期1982-1985,1990,共5页
[Objective] This study aimed to investigate the adsorption properties of the adsorption tower filled with calcium superphosphate on ammonia volatilized with aer- ation. [Method] Adsorption tower filled with calcium su... [Objective] This study aimed to investigate the adsorption properties of the adsorption tower filled with calcium superphosphate on ammonia volatilized with aer- ation. [Method] Adsorption tower filled with calcium superphosphate was adopted as experimental apparatus, which was constructed by poly vinyl chloride (PVC) circular tubes. With hartshorn as the source of ammonia volatilization, the effect of different ratios of height to diameter of the tower filled with equal amount of calcium super-phosphate on ammonia adsorption was investigated. In addition, adsorption tower with height-diameter ratio of 9.9 was selected to adsorb the ammonia emitted from the composting systems of pig manure and chicken manure with optimized and reg- ulated carbon-nitrogen ratio. [Result] Under certain volatilization rate, calcium super- phosphate particles in the adsorption tower could effectively adsorb the ammonia, and the adsorption efficiency was enhanced with the increase of height-diameter ra-tio, which could reach above 90% with height-diameter ratio of more than 1.1; the ammonia emitted from composting systems of pig manure and chicken manure with optimized and regulated carbon-nitrogen ratio could be completely absorbed using adsorption tower with height-diameter ratio of 9.9 filled with calcium superphosphate accounting for about 8% of the weight of composting materials. [Conclusion] Experi- mental results of this study provided reference for the application of adsorption tower filled with calcium superphosphate in the treatment of waste gas emitted from com- posting materials. 展开更多
关键词 Calcium superphosphate COMPOST AMMONIA Adsorption tower
下载PDF
运用Sawyer Tower电路测试薄膜铁电性能 被引量:1
10
作者 张涛 马宏伟 +2 位作者 李敏 张鹏利 赵省贵 《西安科技大学学报》 CAS 2012年第1期124-126,共3页
声表面波煤矿瓦斯传感器是一种新型瓦斯传感器,PZT基高压电铁电薄膜是该类传感器制备的理想功能材料,铁电性作为PZT基铁电薄膜的另一个重要性能对传感器的工作特点和稳定性具有重要影响。因而,测试并掌握具有高压电性铁电薄膜的铁电性... 声表面波煤矿瓦斯传感器是一种新型瓦斯传感器,PZT基高压电铁电薄膜是该类传感器制备的理想功能材料,铁电性作为PZT基铁电薄膜的另一个重要性能对传感器的工作特点和稳定性具有重要影响。因而,测试并掌握具有高压电性铁电薄膜的铁电性也是器件材料表征的一项重要工作。采用Sawyer Tower电路原理,自主设计铁电测试电路,制备PZT基铁电薄膜,并利用该电路测试薄膜的铁电性。由实验结果可知,自主设计的Sawyer Tower电路能简便、有效、准确和直观的测试薄膜的铁电性能,有望广泛应用于薄膜铁电性能测试及研究。 展开更多
关键词 PZT 铁电薄膜 Sawyer tower电路 铁电性能
下载PDF
Tower支持下的App混合式学习研究——以“学习科学与技术”课程为例 被引量:9
11
作者 王云 苑新美 《现代教育技术》 CSSCI 2016年第6期60-66,共7页
文章从Tower支持创建团队、发布任务、协作讨论等功能出发,以"学习科学与技术"课程为例,构建了Tower支持下的App混合式学习模式,设计了基于该模式的教学实施流程,验证了Tower支持下的App混合式学习能有效地促进教学和学习,为... 文章从Tower支持创建团队、发布任务、协作讨论等功能出发,以"学习科学与技术"课程为例,构建了Tower支持下的App混合式学习模式,设计了基于该模式的教学实施流程,验证了Tower支持下的App混合式学习能有效地促进教学和学习,为相关领域的理论和实践研究提供了借鉴。 展开更多
关键词 tower APP 混合式学习 学习科学与技术
下载PDF
“Problem of Towers of Hanoi”仿真软件的设计 被引量:1
12
作者 周斌 《实验室研究与探索》 CAS 北大核心 2011年第7期61-63,71,共4页
"Problem of Towers of Hanoi",用递归的方法能很容易地解决问题,不用递归的方法将会是比较困难,因为随着参与盘子数的不断增多,计算时间和复杂度将会不断增多。运用仿真软件能清晰地勾勒出每个盘子的移动轨迹并给出详细的移... "Problem of Towers of Hanoi",用递归的方法能很容易地解决问题,不用递归的方法将会是比较困难,因为随着参与盘子数的不断增多,计算时间和复杂度将会不断增多。运用仿真软件能清晰地勾勒出每个盘子的移动轨迹并给出详细的移动步骤,这将会使此问题能更形象、更直观的解决。 展开更多
关键词 PROBLEM of towerS of HANOI 递归 仿真软件
下载PDF
基于Hanoi Tower算法的对等组认证模型研究 被引量:1
13
作者 乐光学 《计算机工程》 EI CAS CSCD 北大核心 2005年第11期142-145,共4页
运用对称密码体制、公钥体制和数字签名技术,针对基于中间服务器架构的P2P网络,提出了一个公平且不可抵赖的HanoiTower安全认证协议算法,给出了协议模型实现的算法描述,然后对协议算法的性能和安全性进行了分析,并以某大型企业设计所“... 运用对称密码体制、公钥体制和数字签名技术,针对基于中间服务器架构的P2P网络,提出了一个公平且不可抵赖的HanoiTower安全认证协议算法,给出了协议模型实现的算法描述,然后对协议算法的性能和安全性进行了分析,并以某大型企业设计所“基于P2P网络构建的产品开发协同工作系统”为背景,分析了模型实现的若干关键技术问题。 展开更多
关键词 P2P(Peer to Peer) HANOI tower算法 不可抵赖 安全认证协议
下载PDF
基于Tower的翻转课堂教学模式及其应用研究——以“网络学习共同体”为视角 被引量:3
14
作者 汪存友 陕纳青 《中国教育信息化》 2017年第16期44-47,共4页
随着互联网与教育不断融合,翻转课堂为提高学习者的学习动机和学习效果创造了新的契机。文章在分析翻转课堂与网络学习共同体关系及Tower的功能特点的基础上,提出了基于Tower的翻转课堂教学模式,并将此模式应用到教学过程中。研究表明,... 随着互联网与教育不断融合,翻转课堂为提高学习者的学习动机和学习效果创造了新的契机。文章在分析翻转课堂与网络学习共同体关系及Tower的功能特点的基础上,提出了基于Tower的翻转课堂教学模式,并将此模式应用到教学过程中。研究表明,在基于Tower的翻转课堂中,师生角色有所转变,交互程度有所提升,并且高效完成了知识共享和转移;但同时也发现,学习者参与度较低、自主思考能力较薄弱、教师角色定位不明确等因素会对共同体的学习效果产生负面影响。为此,文中有针对性地提出了改进建议。 展开更多
关键词 翻转课堂 tower 网络学习共同体 教学模式
下载PDF
缘于巴别塔(the Tower of Babel)的故事——访江苏绿源新材料有限公司董事长林永飞
15
作者 邵雅文 《中国标准化》 2013年第1期30-33,共4页
林永飞,江苏绿源新材料有限公司董事长,中国塑料加工工业协会聚氨酯制品专业委员会会长,中国塑料加工工业协会副理事长。
关键词 董事长 新材料 tower 中国塑料加工工业协会 江苏 故事 专业委员会 聚氨酯制品
下载PDF
Hanoi Tower问题动态演示——C图形设计
16
作者 柴世红 王军弟 《兰州工业学院学报》 2001年第3期12-14,共3页
通过对HanoiTower移动递归特性的分析 ,利用TurboC 2 .0系统中相关图形处理函数 。
关键词 Hanoitower问题 递归
下载PDF
Rapid seismic analysis methodology for in-service wind turbine towers 被引量:20
17
作者 Dai Kaoshan Huang Yichao +2 位作者 Gong Changqing Huang Zhenhua Ren Xiaosong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第3期539-548,共10页
The wind energy industry has been growing rapidly during the past decades.Along with this growth,engineering problems have gradually emerged in the wind power industry,including those related to the structural reliabi... The wind energy industry has been growing rapidly during the past decades.Along with this growth,engineering problems have gradually emerged in the wind power industry,including those related to the structural reliability of turbine towers.This study proposes a rapid seismic analysis methodology for existing wind turbine tower structures.The method is demonstrated and validated using a case study on a 1.5 MW tubular steel wind turbine tower.Three finite element(FE)models are developed first.Field tests are conducted to obtain the turbine tower’s vibrational characteristics.The tests include(1) remotely measuring the tower vibration frequencies using a long range laser Doppler Vibrometer and(2) monitoring the tower structural vibration by mounting accelerometers along the height of the tubular structure.In-situ measurements are used to validate and update the FE models of the wind turbine tower.With the updated FE model that represents the practical structural conditions,seismic analyses are performed to study the structural failure,which is defined by the steel yielding of the tubular tower.This research is anticipated to benefit the management of the increasing number of wind energy converters by providing an understanding of the seismic assessment of existing tubular steel wind turbine towers. 展开更多
关键词 wind turbine tower fi eld testing laser sensing SE
下载PDF
Full scale experimental study of a small natural draft dry cooling tower for concentrating solar thermal power plant 被引量:4
18
作者 Xiaoxiao Li Sam Duniam +3 位作者 Hal Gurgenci Zhiqiang Guan Anand Veeraragavan 侯恩哲 《建筑节能》 CAS 2017年第5期113-113,共1页
Concentrating solar thermal power system can provide low carbon,renewable energy resources in countries or regions with strong solar irradiation.For this kind of power plant which is likely to be located in the arid a... Concentrating solar thermal power system can provide low carbon,renewable energy resources in countries or regions with strong solar irradiation.For this kind of power plant which is likely to be located in the arid area,natural draft dry cooling tower is a promising choice.To develop the experimental studies on small cooling tower,a 20 m high natural draft dry cooling tower with fully instrumented measurement system was established by the Queensland Geothermal Energy Centre of Excellence.The performance of this cooling tower was measured with the constant heat input of 600 kW and 840 kW and with ambient temperature ranging from 20 ℃ to 32 ℃.The cooling tower numerical model was refined and validated with the experimental data.The model of 1 MW concentrating solar thermal supercritical CO2 power cycle was developed and integrated with the cooling tower model.The influences of changing ambient temperature and the performance of the cooling tower on efficiency of the power system were simulated.The differences of the mechanism of the ambient temperature effect on Rankine cycle and supercritical CO2 Brayton cycle were analysed and discussed. 展开更多
关键词 tower draft SUPERCRITICAL Rankine LIKELY AMBIENT refined irradiation RENEWABLE Queensland
下载PDF
Thermal Effect of the Cable-Stayed Bridge Tower 被引量:3
19
作者 Zhang Hai-long, Li Jun, Liu Chang-guo, Jiang Tian-hua, Wei jun School of Civil Engineering and Mechanics, Huazhong University of Science and Technology, Wuhan 430074, Hubei, China 《Wuhan University Journal of Natural Sciences》 CAS 2003年第04A期1121-1125,共5页
This paper studies the thermal effect of the cable-stayed bridge tower based on full time accurate measurement and finite element analysis on Xiantao Hanjiang River Highway Bridge. The measured results and the displac... This paper studies the thermal effect of the cable-stayed bridge tower based on full time accurate measurement and finite element analysis on Xiantao Hanjiang River Highway Bridge. The measured results and the displacement variation of top tower show that the tower rotates periodically when it is exposed in sunshine. But the tower column will not decline when there is no sunshine. In spite of in winter or in summer, the period when the tower column changed smallest is from 0∶00 am to 5∶00 am. The time period when the tower column has maximum deviation lags behind the time when the tower column has maximum temperature difference, and this phenomenon is obvious in winter. The conclusions also have directive value in predicting the tower deformations and their directions in construction control of cable-stayed bridge, and in verifying the finite element program. 展开更多
关键词 bridge tower thermal effect DEFORMATION full time measurement
下载PDF
Dynamic performance of cable-stayed bridge tower with multi-stage pendulum mass damper under wind excitations——I:Theory 被引量:4
20
作者 郭安薪 徐幼麟 李惠 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第3期295-306,共12页
In this paper, wind-induced vibration control of a single column tower of a cable-stayed bridge with a multi- stage pendulum mass damper (MSPMD) is investigated. Special attention is given to overcoming space limita... In this paper, wind-induced vibration control of a single column tower of a cable-stayed bridge with a multi- stage pendulum mass damper (MSPMD) is investigated. Special attention is given to overcoming space limitations for installing the control device in the tower and the effect of varying natural frequency of the towers during construction. First, the finite element model of the bridge during its construction and the basic equation of motion of the MSPMD are introduced. The equation of motion of the bridge with the MSPMD under along-wind excitation is then established. Finally, a numerical simulation and parametric study are conducted to assess the effectiveness of the control system for reducing the wind-induced vibration of the bridge towers during construction. The numerical simulation results show that the MSPMD is practical and effective for reducing the along-wind response of the single column tower, can be installed in a small area of the tower, and complies with the time-variant characteristics of the bridge during its entire construction stage. 展开更多
关键词 multi-stage pendulum mass damper cable-stayed bridge single column tower wind-induced vibration
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部