期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Research on the Method of Heat Preservation and Heating for the Drilling System of Polar Offshore Drilling Platform
1
作者 Yingkai Dong Chaohe Chen +2 位作者 Guangyan Jia Lidai Wang Jian Bai 《Energy Engineering》 EI 2024年第5期1173-1193,共21页
This study investigates the heat dissipation mechanism of the insulation layer and other plane insulation layers in the polar drilling rig system.Combining the basic theory of heat transfer with the environmental requ... This study investigates the heat dissipation mechanism of the insulation layer and other plane insulation layers in the polar drilling rig system.Combining the basic theory of heat transfer with the environmental requirements of polar drilling operations and the characteristics of polar drilling processes,we analyze the factors that affect the insulation effect of the drilling rig system.These factors include the thermal conductivity of the insulation material,the thickness of the insulation layer,ambient temperature,and wind speed.We optimize the thermal insulation material of the polar drilling rig system using a steady-state method to measure solid thermal conductivity.By analyzing the distribution of temperature in space after heating,we optimize the distribution and air outlet angle of the heater using Fluent hydrodynamics software.The results demonstrate that under polar conditions,polyisocyanurate with stable thermodynamic properties is selected as the thermal insulation material.The selection of thermal insulation material and thickness significantly affects the thermal insulation effect of the system but has little effect on its heating effect.Moreover,when the air outlet angle of the heater is set to 32.5°,the heating efficiency of the system can be effectively improved.According to heat transfer equations and heat balance theory,we determine that the heating power required for the system to reach 5°C is close to numerical simulation. 展开更多
关键词 Polar drilling drilling system fluid dynamics heat preservation and heating numerical simulation
下载PDF
Application of “soft canning” heat preservation technique in the superalloy forging process
2
作者 WANG Zixing CHEN Guosheng +1 位作者 ZHOU Dianhua WANG Qingzeng 《Baosteel Technical Research》 CAS 2011年第4期21-24,共4页
The "soft canning" heat preservation technique is invented by Baoshan Iron & Steel Co., Ltd. (Hereafter referred to Baosteel), using the flexible insulation material which can be stuck on the surface of the heate... The "soft canning" heat preservation technique is invented by Baoshan Iron & Steel Co., Ltd. (Hereafter referred to Baosteel), using the flexible insulation material which can be stuck on the surface of the heated ingot or billet in the superalloy thermal process. This adhesive insulation material can reduce the temperature drop of the ingot or billet during the transferring or hot working process, and can deform with the billet without dropping. The surface temperature drop can be effectively reduced, so the products can be obtained a good surface quality and the structural uniformity can be improved. The technique is applied to hard-wrought superalloy forging of cogging, superalloy rods finished forging fire and superalloy hot die forging processing,and good results have been achieved. 展开更多
关键词 soft canning SUPERALLOY heat preservation forging
下载PDF
Observation of the Effects of Anesthesia Recovery Nursing Combined with Heat Preservation Measures in Patients Undergoing General Anesthesia Surgery
3
作者 Zhilong Sun Yulin Bu 《Journal of Clinical and Nursing Research》 2024年第7期91-96,共6页
Objective:To observe the application effects of anesthesia recovery nursing with heat preservation measures in patients undergoing general anesthesia surgery.Methods:300 cases of general anesthesia surgery patients in... Objective:To observe the application effects of anesthesia recovery nursing with heat preservation measures in patients undergoing general anesthesia surgery.Methods:300 cases of general anesthesia surgery patients in our hospital from March 2023 to February 2024 were selected and divided into the control group and the observation group according to the random number table method,each with 150 cases.The control group adopted conventional care,while the observation group was given anesthesia recovery care and heat preservation measures on the basis of conventional care.The wake-up time,extubation time,hospitalization time,and the incidence of adverse reactions were compared between the two groups and statistically analyzed.Results:The wake-up time of patients in the control group was 9.71±1.20 hours,and that of the observation group was 6.51±1.02 hours,with statistically significant differences(P<0.05);the extubation times of patients in the observation group and the control group after awakening were 8.52±0.41 min and 10.42±1.12 min,respectively,with statistically significant differences(P<0.05)The hospital stay after the operation in the observation group and the control group was 32.91±4.71 days and 37.24±3.34 days respectively,and the difference was statistically significant(P<0.05),and the incidence rate of adverse reactions after extubation in the observation group(3.33%)was significantly lower than that in the control group(10.00%)(P<0.05).Conclusion:In general anesthesia surgery patients,the implementation of anesthesia recovery nursing with heat preservation measures can significantly improve the physical condition of patients,effectively shorten the duration of surgery and patients’wake-up time,and improve their quality of life,which is worthy of clinical promotion and application. 展开更多
关键词 Anesthesia recovery nursing Heat preservation General anesthesia
下载PDF
Heat preservation,antifouling,hemostatic and antibacterial aerogel wound dressings for emergency treatment
4
作者 Fangling Li Xiaoman Han +6 位作者 Dongdong Cao Junxia Yin Li Chen Dongmei Li Lin Cui Zhiyong Liu Xuhong Guo 《Frontiers of Materials Science》 SCIE CSCD 2023年第2期93-103,共11页
Hemostatic dressings with multiple functions are superior to current hemostatic dressings for use in the complex situation of emergency accidents.In particular,the existing dressings lack consideration for the prevent... Hemostatic dressings with multiple functions are superior to current hemostatic dressings for use in the complex situation of emergency accidents.In particular,the existing dressings lack consideration for the prevention of hypothermic shock after massive hemorrhage.In this study,gelatin(GN)and oxidized pectin(OP)were used for Schiff base cross-linking,and then polyvinyl alcohol(PVA)solution mixed with hemostatic caffeic acid(CA)was introduced to obtain aerogel substrate material(CB)after lyophilization.Polydimethylsiloxane(PDMS)and silver nanowires(Ag NWs)were used to construct a hydrophobic layer,an antibacterial layer and an infrared reflective layer on both sides of CB to prepare a multifunctional aerogel wound dressing with heat preservation,antifouling,hemostasis and antibacterial properties(PDMS-Ag NW-CB).The results showed that the infrared transmittance of PDMS-Ag NW-CB is almost 0,so that thermal energy loss from the body is minimized.The contact angles with water and blood are 129°and 120°,respectively,which have the effect of antifouling.This dressing can absorb blood quickly within 10 min,adhere to and gather platelets,and achieve hemostasis.It has good antibacterial and biocompatibility.Therefore,PDMS-Ag NW-CB has great potential in application to emergency treatment. 展开更多
关键词 heat preservation HEMOSTASIS ANTIFOULING ANTIBACTERIAL wound dressing
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部