期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Clinical analysis of intracranial germinoma's craniospinal irradiation using helical tomotherapy 被引量:14
1
作者 Baolin Qu Lei Du +4 位作者 Yurong Huang Wei Yu Boning Cai Shouping Xu Lin Ma 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2014年第3期247-254,共8页
Objective: To evaluate the short-term clinical outcomes of intracranial germinoma patients treated with craniospinal irradiation (CSI) using helical tomotherapy (HT) system in our center. Methods: Twenty-three p... Objective: To evaluate the short-term clinical outcomes of intracranial germinoma patients treated with craniospinal irradiation (CSI) using helical tomotherapy (HT) system in our center. Methods: Twenty-three patients who were treated with CSI in our center from January 2008 to July 2012 were collected, with an average age of 20. M1 of the patients' CSI used the HT system. The total doses were 27-36 Gy/15-20 F (1.5-2 Gy per fraction), and total local doses were 46-60 Gy/30-50 F (5 fractions per week). M1 female patients for CSI were treated with left-right parallel-opposed field irradiation to protect their ovarian functions. Median follow-up time was 30.9 months (range, 5-67 months). The SPSS19.0 software was used, and the overall survival (OS) was calculated using the Kaplan-Meier method. Results: Among 17 patients with assessable tumors, 9 cases (52.9%) were CR, 7 cases (41.2%) were PR, and 1 case (5.9%) was SD. Hematological toxicity was the severest side-effect occurred in the procedure of CSI. The level 1-4 acute leukopenia were 8.7%, 30.4%, 34.8% and 21.7% and the level 1-4 acute thrombopenia were 8.7%, 30.4%, 21.7% and 8.7%, respectively. Conclusions: For primary intracranial germinomas, HT can be used to implement CSI for simplifying radiotherapy procedures, improving radiotherapy accuracy, enhancing protection of peripheral organs at risk (ORA) and guaranteeing therapeutic effects. With the acceptable acute and long-term toxicity, CSI using HT in intracranial germinoma patients can be a safe and alternative mode. 展开更多
关键词 Germinomas craniospinal irradiation (CSI) helical tomotherapy (HT)
下载PDF
Helical tomotherapy and volumetric modulated arc therapy:New therapeutic arms in the breast cancer radiotherapy 被引量:7
2
作者 Olivier Lauche Youlia M Kirova +8 位作者 Pascal Fenoglietto Emilie Costa Claire Lemanski Celine Bourgier Olivier Riou David Tiberi Francois Campana Alain Fourquet David Azria 《World Journal of Radiology》 CAS 2016年第8期735-742,共8页
AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT ... AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT and 42 VMAT). Dose were 63.8 Gy(HT) and 63.2 Gy(VMAT) in the tumour bed, 52.2 Gy in the breast, 50.4 Gy in supraclavicular nodes(SCN) and internal mammary chain(IMC) with HT and 52.2 Gy and 49.3 Gy in IMC and SCN with VMAT in 29 fractions. Margins to particle tracking velocimetry were greater in the VMAT cohort(7 mm vs 5 mm).RESULTS For the HT cohort, the coverage of clinical target volumes was as follows: Tumour bed: 99.4% ± 2.4%; breast: 98.4% ± 4.3%; SCN: 99.5% ± 1.2%; IMC:96.5% ± 13.9%. For the VMAT cohort, the coverage was as follows: Tumour bed: 99.7% ± 0.5%, breast: 99.3% ± 0.7%; SCN: 99.6% ± 1.4%; IMC: 99.3% ± 3%. For ipsilateral lung, Dmean and V20 were 13.6 ± 1.2 Gy, 21.1% ± 5%(HT) and 13.6 ± 1.4 Gy, 20.1% ± 3.2%(VMAT). Dmean and V30 of the heart were 7.4 ± 1.4 Gy, 1% ± 1%(HT) and 10.3 ± 4.2 Gy, 2.5% ± 3.9%(VMAT). For controlateral breast Dmean was 3.6 ± 0.2 Gy(HT) and 4.6 ± 0.9 Gy(VMAT). Acute skin toxicity grade 3 was 5% in the two cohorts.CONCLUSION HT and VMAT in complex adjuvant breast irradiation allow a good coverage of target volumes with an acceptable acute tolerance. A longer follow-up is needed to assess the impact of low doses to healthy tissues. 展开更多
关键词 Three-dimensional conformal radiotherapy Intensity modulated radiation therapy TOXICITY helical tomotherapy Volumetric modulated arc therapy Breast cancer radiotherapy
下载PDF
Clinical study on the changes of the tumor target volume and organs at risk in helical tomotherapy for nasopharyngeal carcinoma 被引量:18
3
作者 LU Na FENG Lin-chun +3 位作者 CAI Bo-ning HOU Jun WANG Yun-lai XIE Chuan-bin 《Chinese Medical Journal》 SCIE CAS CSCD 2012年第1期87-90,共4页
Background Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT).The aim of this study was to evaluate the changes in the target volume and organs at risk (OARs) of patients... Background Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT).The aim of this study was to evaluate the changes in the target volume and organs at risk (OARs) of patients with nasopharyngeal carcinoma (NPC) during helical tomotherapy.Methods Forty-three patients with NPC and treated via HT from March 2008 to January 2010 were reviewed retrospectively.Repeated CT scanning and plan adaptation were conducted at the 20th fraction during radiotherapy.The volumetric differences between the two scans were evaluated for nasopharyngeal tumor and retro- pharyngeal lymph nodes (GTVnx),neck lymph nodes (GTVnd),and parotid glands,as well as the axial diameter of the head.Results The median interval between the two scans was 25 days (23-28 days).The volumetric decrease in GTVnx was 30.1% (median,29.8%) and in GTVnd 41.6% (median,45.9%).The variation in the GTVnd volume was correlated with the weight loss of the patient.The volume of the left parotid gland decreased by 35.5% (median,33.4%) and of the right parotid glands decreased by 36.8% (median,33.5%).The axial diameter of the head decreased by 9.39% (median,9.1%).Conclusions The target volume and OARs of patients with NPC varied considerably during HT.These changes may have potential dosimetric effects on the target volume and/or OARs and influence the clinical outcome.Repeated CT scanning and replanning during the HT for NPC patients with a large target volume or an obvious weight loss are recommended. 展开更多
关键词 nasopharyngeal carcinoma helical tomotherapy target volume organs at risk
原文传递
Dosimetric comparison between helical tomotherapy and intensity-modulated radiation therapy plans for non-small cell lung cancer 被引量:4
4
作者 MENG Ling-ling FENG Lin-chun WANG Yun-lai DAI Xiang-kun XIE Chuan-bin 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第11期1667-1671,共5页
Background Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformit... Background Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformity, dose gradients, and protection for the lung than IMRT plan. We compared the dosimetric characteristics of HT for NSCLC with those of conventional IMRT to observe the superiority of HT. Methods There was a comparative case series comprising 10 patients with NSCLC. Computed tomographic (CT) images of delineated targets were transferred to the PrecisePlan planning system (IMRT) and Tomo planning system (HT). The prescription doses were 70 Gy/33F for the gross tumor volume (GTV) and the visible lymph nodes (GTVnd), 展开更多
关键词 helical tomotherapy intensity modulated radiotherapy non-small-cell lung cancer DOSIMETRY
原文传递
An Evaluation of Inter-Fractional Set-Up Errors in Patients Treated with Distinct Immobilization Equipment for Varying Anatomical Regions
5
作者 Sibel Karaca Hamit Başaran +1 位作者 Timur Koca Ferhat Özbayrak 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第2期121-129,共9页
This study aims to evaluate inter-fractional set-up errors in patients treated with distinct immobilization equipment (thermoplastic mask, knee-fix and feet-fix, wing board and vac-lok) for four anatomical regions inc... This study aims to evaluate inter-fractional set-up errors in patients treated with distinct immobilization equipment (thermoplastic mask, knee-fix and feet-fix, wing board and vac-lok) for four anatomical regions including brain, head and neck (HN), thorax and pelvis. Data of randomly selected 140 patients who were treated for four anatomical regions were obtained using Hi-Art Helical Tomotherapy (HT) system. Pre-treatment planning was based on automatic registration readings of computed tomography (CT) and mega-voltage computed tomography (MVCT) on a daily basis. Distinct immobilization equipment was used for varying anatomical regions. Individual mean set-up error (M), systematic error (Σ), and random error (σ) values were calculated through daily translational and rotational deviation values. The size of translational, systematic and random error was 1.31 - 4.93 mm for brain, 2.28 - 4.88 mm for HN, 4.04 - 9.90 mm for thorax, and 6.34 - 14.68 mm for pelvis. Rotational values were as follows: 0.06&deg - 0.73&deg for brain, 0.42&deg - 0.6&deg for HN, 0.48&deg - 1.14&deg for thorax and 0.65&deg - 1.05&deg for pelvis. The highest translational, systematic and random error value was obtained from the pelvic regional. The highest standard and random error value in pitch and roll was produced in the rotational direction of the pelvis (0.05° and 0.71°), while the highest error value in yaw was (1.14°) produced from thorax. Inter-fractional set-up errors were most commonly produced in the pelvis, followed by thorax. Our study results suggest that the highest systematic and random errors are found for thorax and pelvis. Distinct immobilization equipment was important in these results. Safety margins around the clinical target volume (CTV) are changeable for different anatomical regions. A future work could be developed to new equipment for immobilization because of the reduced margins CTV. 展开更多
关键词 Hi-Art helical tomotherapy IGRT Inter-Fractional Set-Up Errors Rotational Variation Translational Variation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部