Under most models of the early universe evolution, high-frequency gravitational waves (HFGWs) were produced. They are referred to as “relic” high-frequency gravitational waves or HFRGWs and their detection and measu...Under most models of the early universe evolution, high-frequency gravitational waves (HFGWs) were produced. They are referred to as “relic” high-frequency gravitational waves or HFRGWs and their detection and measurement could provide important information on the origin and development of our Universe – information that could not otherwise be obtained. So far three instruments have been built to detect and measure HFRGWs, but so far none of them has achieved the required sensitivity. This paper concerns another detector, originally proposed by Baker in 2000 and patented, which is based upon a recently discovered physical effect (the Li effect);this detector has accordingly been named the “Li-Baker detector.” The detector has been a joint development effort by the P. R. China and the United States HFGW research teams. A rigorous examination of the detector’s performance is important in the ongoing debate over the value of attempting to construct a Li-Baker detector and, in particular, an accurate prediction of its sensitivity in the presence of significant noise will decide whether the Li-Baker detector will be capable of detecting and measuring HFRGWs. The potential for useful HFRGW measurement is theoretically confirmed.展开更多
Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this ...Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.展开更多
The principle and method of both radar target imaging and velocity measurement simultaneously based on step frequency waveforms is presented. Velocity compensation is necessary in order to obtain the good High resolut...The principle and method of both radar target imaging and velocity measurement simultaneously based on step frequency waveforms is presented. Velocity compensation is necessary in order to obtain the good High resolution range profile since this waveform is greatly sensitive to the Doppler shift. The velocity measurement performance of the four styles is analyzed with two pulse trains consisted of positive and negative step frequency waveforms. The velocity of targets can be estimated first coarsely by using the pulse trains with positive-positive step frequency combination, and then fine by positive-negative combination. Simulation results indicate that the method can accomplish the accurate estimation of the velocity with efficient computation and good anti-noise performance and obtain the good HRRP simultaneously.展开更多
In deep space exploration,many engineering and scientific requirements require the accuracy of the measured Doppler frequency to be as high as possible.In our paper,we analyze the possible frequency measurement points...In deep space exploration,many engineering and scientific requirements require the accuracy of the measured Doppler frequency to be as high as possible.In our paper,we analyze the possible frequency measurement points of the third-order phase-locked loop(PLL)and find a new Doppler measurement strategy.Based on this finding,a Doppler frequency measurement algorithm with significantly higher measurement accuracy is obtained.In the actual data processing,compared with the existing engineering software,the accuracy of frequency of 1 second integration is about 5.5 times higher when using the new algorithm.The improved algorithm is simple and easy to implement.This improvement can be easily combined with other improvement methods of PLL,so that the performance of PLL can be further improved.展开更多
An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system...An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system based on personal computer (PC) is developed hereby. It senses voltage and current in isolation from generators with transformers, and then the measured values are amplified, filtered, transformed into single-ended signals and converted to RMS. The detected signals are transformed into digital signals through Data Acquisition Card (DAQ) and the data are processed with quadratic fit in Labview. Finally, the controller completes constant power output. The experiment results indicate that the energy detection system can measure the output parameters precisely and the controller can achieve constant power control.展开更多
The new radar system of combination of the hopped-frequency with the conical scan is presented. According to the principle and expression of the conical scan hopped-frequency signal, the angle processing method in whi...The new radar system of combination of the hopped-frequency with the conical scan is presented. According to the principle and expression of the conical scan hopped-frequency signal, the angle processing method in which angle information is obtained by taking discrete Fourier transform (DFT) for the conical envelop of each scattering centre by means of high range resolution profile (HRRP) is presented, and the corresponding formula is derived. The influence of non-ideal factors, such as amplitude fluctuation noise and system noise, leakage of time and frequency domain, unstable rotation of antenna, and missile rotation, on angle-measurement precision and the possible solving methods are also focused on. The simulation results show that the combination of the hopped-frequency and conical scan system could get satisfactory angle information, which could ensure good quality when used in practical tracking radar.展开更多
We focus on the high frequency current method which is widely applied in the partial discharge(PD)detection of cables.Aiming at guaranteeing the accuracy of this method,we study an innovative time-domain technology fo...We focus on the high frequency current method which is widely applied in the partial discharge(PD)detection of cables.Aiming at guaranteeing the accuracy of this method,we study an innovative time-domain technology for effectively measuring the transfer impedance of the high frequency current transformers(HFCTs).The proposed technology called pulse injection method obtains the system response under the excitation of the wide-band instantaneous pulse signal.Firstly,by studying the working principle of HFCTs,we summarize that the bandwidth of the selected signal acquisition device should be at least 100 MHz to ensure measurement accuracy.Secondly,Gauss pulse and square wave pulse are generated to determine the effects of different sources.The measurement results indicate that Gauss pulse is more suitable for pulse injection method,and the rise time should be under 10 ns to improve the starting frequency of oscillation distortion.Finally,the transfer impedance curves of five types of HFCTs are acquired by both pulse injection and traditional point-frequency methods.The measurement results show a remarkable consistency between two methods.However,pulse injection method requires the simpler operation and lias a higher resolution,obviously improving the measurement efficiency and bet ter displaying the details of the transfer impedance curves.展开更多
A novel method for microwave surface resistance measurement of high temperature superconductor thin film at multi-frequency by multimode of sapphire rod is introduced. This method has the advantages of high sensitivit...A novel method for microwave surface resistance measurement of high temperature superconductor thin film at multi-frequency by multimode of sapphire rod is introduced. This method has the advantages of high sensitivity and large dynamic range of the measurement. By using this method, the frequency dependent microwave surface resistance of a single piece of high temperature superconductor thin film can be characterized within one temperature cycle. This method is capable of reducing the amount of work in surface resistance measurement and providing supports to the research and the industrialization of high temperature superconductor thin film.展开更多
This paper presents the unsteady data acquisition system used to measure the pressure field in high speed compressors.Details and electronic sketches are given for the conditioners developed in-house that have been us...This paper presents the unsteady data acquisition system used to measure the pressure field in high speed compressors.Details and electronic sketches are given for the conditioners developed in-house that have been used to amplify and to filter the pressure signal with the aim of acquiring data up to 150 kHz.A discussion of the experimental results carried out in a centrifugal compressor is proposed.Through different processing of the pressure signals and a comparison with URANS simulations,the excitation of the pressure transducers by the pressure waves generated by shock waves that occur between the impeller and the diffuser is highlighted.The levels of pressure fluctuations measured when entering into surge are also presented and reveal very repetitive behaviour of the flow instabilities.展开更多
The loss of a high-finesse Fabry-Perot cavity was measured using frequency scan and cavity ring-down techniques.Different transverse modes were examined by sweeping the frequency of the laser across the corresponding ...The loss of a high-finesse Fabry-Perot cavity was measured using frequency scan and cavity ring-down techniques.Different transverse modes were examined by sweeping the frequency of the laser across the corresponding resonances.In addition,cavity ring-down technique was used to measure the loss of the Fabry-Perot cavity and a simple model was employed to remove the influence of finite response time of the optical switch and the detection circuit.展开更多
文摘Under most models of the early universe evolution, high-frequency gravitational waves (HFGWs) were produced. They are referred to as “relic” high-frequency gravitational waves or HFRGWs and their detection and measurement could provide important information on the origin and development of our Universe – information that could not otherwise be obtained. So far three instruments have been built to detect and measure HFRGWs, but so far none of them has achieved the required sensitivity. This paper concerns another detector, originally proposed by Baker in 2000 and patented, which is based upon a recently discovered physical effect (the Li effect);this detector has accordingly been named the “Li-Baker detector.” The detector has been a joint development effort by the P. R. China and the United States HFGW research teams. A rigorous examination of the detector’s performance is important in the ongoing debate over the value of attempting to construct a Li-Baker detector and, in particular, an accurate prediction of its sensitivity in the presence of significant noise will decide whether the Li-Baker detector will be capable of detecting and measuring HFRGWs. The potential for useful HFRGW measurement is theoretically confirmed.
文摘Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.
文摘The principle and method of both radar target imaging and velocity measurement simultaneously based on step frequency waveforms is presented. Velocity compensation is necessary in order to obtain the good High resolution range profile since this waveform is greatly sensitive to the Doppler shift. The velocity measurement performance of the four styles is analyzed with two pulse trains consisted of positive and negative step frequency waveforms. The velocity of targets can be estimated first coarsely by using the pulse trains with positive-positive step frequency combination, and then fine by positive-negative combination. Simulation results indicate that the method can accomplish the accurate estimation of the velocity with efficient computation and good anti-noise performance and obtain the good HRRP simultaneously.
基金supported by the National Natural Science Foundation of China(Grant Nos.11773060,11973074,U1831137 and 11703070)National Key Basic Research and Development Program(2018YFA0404702)+1 种基金Shanghai Key Laboratory of Space Navigation and Positioning(3912DZ227330001)the Key Laboratory for Radio Astronomy of CAS。
文摘In deep space exploration,many engineering and scientific requirements require the accuracy of the measured Doppler frequency to be as high as possible.In our paper,we analyze the possible frequency measurement points of the third-order phase-locked loop(PLL)and find a new Doppler measurement strategy.Based on this finding,a Doppler frequency measurement algorithm with significantly higher measurement accuracy is obtained.In the actual data processing,compared with the existing engineering software,the accuracy of frequency of 1 second integration is about 5.5 times higher when using the new algorithm.The improved algorithm is simple and easy to implement.This improvement can be easily combined with other improvement methods of PLL,so that the performance of PLL can be further improved.
文摘An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system based on personal computer (PC) is developed hereby. It senses voltage and current in isolation from generators with transformers, and then the measured values are amplified, filtered, transformed into single-ended signals and converted to RMS. The detected signals are transformed into digital signals through Data Acquisition Card (DAQ) and the data are processed with quadratic fit in Labview. Finally, the controller completes constant power output. The experiment results indicate that the energy detection system can measure the output parameters precisely and the controller can achieve constant power control.
基金the Ministerial Level Advanced Research Foundation(040230105)
文摘The new radar system of combination of the hopped-frequency with the conical scan is presented. According to the principle and expression of the conical scan hopped-frequency signal, the angle processing method in which angle information is obtained by taking discrete Fourier transform (DFT) for the conical envelop of each scattering centre by means of high range resolution profile (HRRP) is presented, and the corresponding formula is derived. The influence of non-ideal factors, such as amplitude fluctuation noise and system noise, leakage of time and frequency domain, unstable rotation of antenna, and missile rotation, on angle-measurement precision and the possible solving methods are also focused on. The simulation results show that the combination of the hopped-frequency and conical scan system could get satisfactory angle information, which could ensure good quality when used in practical tracking radar.
文摘We focus on the high frequency current method which is widely applied in the partial discharge(PD)detection of cables.Aiming at guaranteeing the accuracy of this method,we study an innovative time-domain technology for effectively measuring the transfer impedance of the high frequency current transformers(HFCTs).The proposed technology called pulse injection method obtains the system response under the excitation of the wide-band instantaneous pulse signal.Firstly,by studying the working principle of HFCTs,we summarize that the bandwidth of the selected signal acquisition device should be at least 100 MHz to ensure measurement accuracy.Secondly,Gauss pulse and square wave pulse are generated to determine the effects of different sources.The measurement results indicate that Gauss pulse is more suitable for pulse injection method,and the rise time should be under 10 ns to improve the starting frequency of oscillation distortion.Finally,the transfer impedance curves of five types of HFCTs are acquired by both pulse injection and traditional point-frequency methods.The measurement results show a remarkable consistency between two methods.However,pulse injection method requires the simpler operation and lias a higher resolution,obviously improving the measurement efficiency and bet ter displaying the details of the transfer impedance curves.
文摘A novel method for microwave surface resistance measurement of high temperature superconductor thin film at multi-frequency by multimode of sapphire rod is introduced. This method has the advantages of high sensitivity and large dynamic range of the measurement. By using this method, the frequency dependent microwave surface resistance of a single piece of high temperature superconductor thin film can be characterized within one temperature cycle. This method is capable of reducing the amount of work in surface resistance measurement and providing supports to the research and the industrialization of high temperature superconductor thin film.
基金the company Turbomeca which supports the centrifugal compressor research program
文摘This paper presents the unsteady data acquisition system used to measure the pressure field in high speed compressors.Details and electronic sketches are given for the conditioners developed in-house that have been used to amplify and to filter the pressure signal with the aim of acquiring data up to 150 kHz.A discussion of the experimental results carried out in a centrifugal compressor is proposed.Through different processing of the pressure signals and a comparison with URANS simulations,the excitation of the pressure transducers by the pressure waves generated by shock waves that occur between the impeller and the diffuser is highlighted.The levels of pressure fluctuations measured when entering into surge are also presented and reveal very repetitive behaviour of the flow instabilities.
基金Supported by Bureau of Comprehensive Planning,Chinese Academy of Sciences
文摘The loss of a high-finesse Fabry-Perot cavity was measured using frequency scan and cavity ring-down techniques.Different transverse modes were examined by sweeping the frequency of the laser across the corresponding resonances.In addition,cavity ring-down technique was used to measure the loss of the Fabry-Perot cavity and a simple model was employed to remove the influence of finite response time of the optical switch and the detection circuit.