In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc...In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.展开更多
To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right...To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats.展开更多
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox...The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.展开更多
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ...A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.展开更多
基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,...基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,经BLAST验证特异性,最终筛选3条松仁特异性肽段。方法学验证结果表明,方法在0.001~50mg/mL范围内线性关系良好,定量限为1mg/kg;在饼干、巧克力和饮料3种空白基质中的平均回收率为88.50%~107.57%,相对标准偏差不高于6.08%,基质效应为89.77%~96.13%。该方法具有灵敏度高、特异性好的优势,可应用于饼干、巧克力、饮料等食品样品中松仁过敏原的检测,为我国食品标签真实性检验及食品中隐性过敏原的检测提供技术支持。展开更多
Amantadine (AMA) is an anti-viral drug used in apiculture to protect honeybee against the sacbrood virus (Morator aetatulae). This study described a reliable high-performance liquid chromatographic (HPLC) method...Amantadine (AMA) is an anti-viral drug used in apiculture to protect honeybee against the sacbrood virus (Morator aetatulae). This study described a reliable high-performance liquid chromatographic (HPLC) method for analyzing AMA in honey using a solid-phase extraction (SPE) cartridge (Plexa PCX) for purification, 4-fluoro-7- nitro-2,1,3-benzoxadiazole (NBD-F) as a pre-column derivatization agent, and fluorometric detection (λex =470 nm, λem=530 nm). The chromatographic separation was performed on an XDB C18 column (150×4.6 mm i.d.) using 0.1% trifluoroacetic acid/acetonitrile (35 ; 65, V/V) as the mobile phase at a flow rate of 1.0 mLomin 1 with a run time of 20 min. Under these optimal conditions, a linear relationship was observed in the range of 0.025--1.0μg·mL-1 with a good correlation coefficient (0.998) and low limit of detection (0.0080 μg·g-1), the recoveries were all above 90%, and the intra-day and inter-day precision (RSD) ranged from 3.4%--5.1%.展开更多
In this paper, a high-performance liquid chromatography coupled with ultraviolet detection and Fourier transform-ion cyclotron resonance mass spectrometry (HPLC-UV/FrICRMS) method was described for the investigation...In this paper, a high-performance liquid chromatography coupled with ultraviolet detection and Fourier transform-ion cyclotron resonance mass spectrometry (HPLC-UV/FrICRMS) method was described for the investigation of impurity profile in moxifloxacin (MOX) drug substance and chemical reference substance. Ten impurities were detected by HPLC-UV, while eight impurities were identified by using the high accurate molecular mass combined with multiple-stage mass spectrometric data and fragmentation rules. In addition, to our knowledge, five impurities were founded for the first time in MOX drug substance.展开更多
文摘In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.
基金This work was supported by the National Natural Science Foundation of China (Grant No. 30560171).
文摘To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats.
文摘The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.
基金supported both by the Natural Science Foundations of Hebei(No.B2008000210)the Scientific Research Foundation of Agricultural University of Hebei.
文摘A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples.
文摘基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,经BLAST验证特异性,最终筛选3条松仁特异性肽段。方法学验证结果表明,方法在0.001~50mg/mL范围内线性关系良好,定量限为1mg/kg;在饼干、巧克力和饮料3种空白基质中的平均回收率为88.50%~107.57%,相对标准偏差不高于6.08%,基质效应为89.77%~96.13%。该方法具有灵敏度高、特异性好的优势,可应用于饼干、巧克力、饮料等食品样品中松仁过敏原的检测,为我国食品标签真实性检验及食品中隐性过敏原的检测提供技术支持。
文摘Amantadine (AMA) is an anti-viral drug used in apiculture to protect honeybee against the sacbrood virus (Morator aetatulae). This study described a reliable high-performance liquid chromatographic (HPLC) method for analyzing AMA in honey using a solid-phase extraction (SPE) cartridge (Plexa PCX) for purification, 4-fluoro-7- nitro-2,1,3-benzoxadiazole (NBD-F) as a pre-column derivatization agent, and fluorometric detection (λex =470 nm, λem=530 nm). The chromatographic separation was performed on an XDB C18 column (150×4.6 mm i.d.) using 0.1% trifluoroacetic acid/acetonitrile (35 ; 65, V/V) as the mobile phase at a flow rate of 1.0 mLomin 1 with a run time of 20 min. Under these optimal conditions, a linear relationship was observed in the range of 0.025--1.0μg·mL-1 with a good correlation coefficient (0.998) and low limit of detection (0.0080 μg·g-1), the recoveries were all above 90%, and the intra-day and inter-day precision (RSD) ranged from 3.4%--5.1%.
基金the Ministry of Public Health of the People's Republic of China(No200802038) for financial support
文摘In this paper, a high-performance liquid chromatography coupled with ultraviolet detection and Fourier transform-ion cyclotron resonance mass spectrometry (HPLC-UV/FrICRMS) method was described for the investigation of impurity profile in moxifloxacin (MOX) drug substance and chemical reference substance. Ten impurities were detected by HPLC-UV, while eight impurities were identified by using the high accurate molecular mass combined with multiple-stage mass spectrometric data and fragmentation rules. In addition, to our knowledge, five impurities were founded for the first time in MOX drug substance.