期刊文献+
共找到6,365篇文章
< 1 2 250 >
每页显示 20 50 100
Simultaneous Determination of Ultraviolet Absorbers and Antibacterial Agents in Textiles by Ultra-High Performance Liquid Chromatography/Orbitrap High Resolution Mass Spectrometry 被引量:1
1
作者 Chengyun Wang Tangtang Xie +2 位作者 Rong Xu Junfeng Lin Lixia Li 《World Journal of Engineering and Technology》 2017年第1期1-18,共18页
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl... This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles. 展开更多
关键词 Ultra-high Performance Liquid chromatography/Orbitrap high resolution mass spectrometry Benzotriazoleultraviolet ABSORBERS Isothiazolinone Tric-losan 4-Chloro-3 5-Dimethyl Phenol
下载PDF
Application of Liquid Chromatography-High Resolution Time-of-flight Mass Spectrometry in the Detection of Raw Milk and Dairy Products
2
作者 Yi LI Luman HUO +5 位作者 Lixue DONG Xuesong WANG Litian ZHANG Ruihuan DU Aijun LI Lei WANG 《Agricultural Biotechnology》 CAS 2021年第1期111-113,共3页
Milk and dairy products are more and more popular with consumers due to their various nutrients, and their quality and safety issues have always been concerned. Therefore, the development of rapid, accurate and simple... Milk and dairy products are more and more popular with consumers due to their various nutrients, and their quality and safety issues have always been concerned. Therefore, the development of rapid, accurate and simple screening techniques is of great significance. Liquid chromatography-high resolution time-of-flight mass spectrometry has high-resolution and high-throughput detection functions, and has gradually begun to be applied in the detection of milk and dairy products. This paper summarized the application of milk and dairy products in liquid chromatography-high resolution time-of-flight mass spectrometry, laying a foundation for the development of new methods. 展开更多
关键词 Milk and dairy products high resolution time-of-flight mass spectrometry Pesticide and veterinary drug residues
下载PDF
Determination of Sym-triazine Residues in Animal-derived Food by Liquid Chromatography-High Resolution Mass Spectrometry
3
作者 Gong Xiaoming Yang Lijun +4 位作者 Wang Hongtao Ma Ronggui Ding Kuiying Guo Liqiang Sun Jun 《Animal Husbandry and Feed Science》 CAS 2016年第3期146-150,共5页
[Objective]The research aimed to establish a liquid chromatography-high-resolution mass spectrometry for detecting residues of diclazuril,toltrazuril and its metabolites in animal-derived food.[Method]The samples were... [Objective]The research aimed to establish a liquid chromatography-high-resolution mass spectrometry for detecting residues of diclazuril,toltrazuril and its metabolites in animal-derived food.[Method]The samples were pre-treated by QuEChERS technology and detected by Exactive liquid chromatography-high resolution mass spectrometry.The liquid chromatography-high-resolution mass spectrometry for detecting the residues of diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide in animal-derived food was established.[Result]Diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide showed a good linear correlation in the range of 2.0-50.0μg/L(r^2〉0.99).The average recoveries of these four compounds in bovine power at the spiked levels of 2,10 and 20μg/kg were 74.5%-90.1%,and the relative standard deviations(RSD)were 15.4%-17.5%.[Conclusion]This method was stable and reliable,and could be used to detect diclazuril,toltrazuril,toltrazuril sulfone and toltrazuril sulfoxide in animal-derived food. 展开更多
关键词 Animal-derived food Sym-triazine drugs QuEChERS Liquid chromatography-high-resolution mass spectrometry
下载PDF
Quantification of trace amounts of impurities in high purity cobalt by high resolution inductively coupled plasma mass spectrometry 被引量:10
4
作者 XIE Hualin HUANG Kelong +1 位作者 NIE Xidu TANG Yougen 《Rare Metals》 SCIE EI CAS CSCD 2007年第3期286-291,共6页
A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, ... A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect standard addition method
下载PDF
Determination of trace elements in high purity nickel by high resolution inductively coupled plasma mass spectrometry 被引量:11
5
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2012年第9期2416-2420,共5页
The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss... The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity nickel trace element matrix effect internal standard
下载PDF
Quantification of Trace Amounts of Impurities in High Purity Cobalt by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:3
6
作者 Hua Lin XIE Xi Du NIE You Gen TANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1077-1080,共4页
An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ... An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect spectral interference internal standards.
下载PDF
Direct Determination of Trace Impurities in High Purity Zinc Oxide by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:2
7
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2006年第2期28-32,共5页
The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuter... The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented. 展开更多
关键词 high purity zinc oxide trace impurities high resolution inductively coupled plasma mass spectrometry spectral interferences microwave digestion
下载PDF
Determination of Trace Elements in High Purity Gold by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:1
8
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2009年第4期608-612,共5页
Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/... Trace elements were determined in high purity gold by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Sample were decomposed by aqua regia. To overcome some potentially problematic spectra/ interference, measurements were acquired in both medium and high resolution modes. The matrix effects due to the presence of excessive HCl and Au were evaluated. The optimum conditions for the determination was tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits range from 0.01ug/g to 0.28ug/g depending on the elements. The method is accurate, quick and convenient. It has been applied to the determination of trace elements in high purity gold with satisfactory results. 展开更多
关键词 high purity gold trace elements high resolution inductively coupled plasma mass spectrometry spectral interferences
下载PDF
High Resolution Mass Spectrometry for the Recognition and Structural Characterization of a New Antimicrobial Compound 被引量:1
9
作者 cia Carrano +1 位作者 Annamaria Naggi Elena Urso 《Pharmacology & Pharmacy》 2018年第5期135-148,共14页
Identification of novel specialized metabolites or bioactive compounds represents the main objective in the research field of natural product leads and drug discovery. Mass spectrometry (MS) provides a central tool to... Identification of novel specialized metabolites or bioactive compounds represents the main objective in the research field of natural product leads and drug discovery. Mass spectrometry (MS) provides a central tool to expedite and make more efficient the discovery and isolation phases, while minimizing the waste of resources on rediscovery of known compounds. MS contributes acutely to elucidation and identification of numerous species because it allows molecular mass and structural features determination. In particular, identification of the elemental composition of a precursor ion of interest by accurate mass measurement and investigation of dissociative processes undergone by the molecule, represent a worthy methodology to access the structure assignment. The aim of this study was to discover and identify novel antibacterial drugs from microbial source in a jungle of already known compounds. The focus of this paper is on the analytical strategy that permitted the disclosure of a new compound, otherwise confused with other substances. Emphasis is placed on the interpretation of the ESI-MS/MS fragmentation pattern that combined with high resolution mass determination, allowed step by step to properly deduce the exact molecular formula of an unknown component with a molecular weight higher than 1500 Daltons. 展开更多
关键词 Antibiotic Development Antibiotic Discovery high resolution mass spectrometry Molecular FORMULA MS/MS FRAGMENTATION FT ICR MS
下载PDF
Data Analysis for High Throughput Detection of 18 Phthalates in Textiles Based on High Resolution Mass Spectrometry
10
作者 QU Lianyi LUO Xin +5 位作者 NIU Zengyuan YE Xiwen ZHANG Li TANG Zhixu ZHANG Lin ZHU Ping 《Journal of Donghua University(English Edition)》 EI CAS 2019年第2期158-162,共5页
Liquid chromatography coupled to high resolution mass spectrometry(LC-HRMS)was used to establish a high throughput and sensitive method for 18 phthalic acid esters(PAEs)in textiles.The method was applied to screen PAE... Liquid chromatography coupled to high resolution mass spectrometry(LC-HRMS)was used to establish a high throughput and sensitive method for 18 phthalic acid esters(PAEs)in textiles.The method was applied to screen PAEs in 413 textile samples and 7 434 pieces of test data were analyzed.Further discussion was conducted about specific compounds,textile materials,detected value distribution and positive rate of samples.Twenty-nine percent of samples were detected with PAEs,and no samples were detected beyond regulations.Diisobutyl phthalate(DiBP),Dibutyl phthalate(DBP)and Di-2-ethylhexyl phthalate(DEHP)were detected with high frequency,and most samples were fabrics with coating and printing.This study can be used to reflect distribution of phthalate residues in textiles on the market and provide data support for risk assessment of PAEs for textile producers and consumers. 展开更多
关键词 high resolution mass spectrometry TEXTILE phthalic acid ESTERS PAES data analysis
下载PDF
Discovery of pulmonary fibrosis inhibitor targeting TGF-b RI in Polygonum cuspidatum by high resolution mass spectrometry with in silico strategy
11
作者 Huarong Xu Jiameng Qu +4 位作者 Jian Wang Kefei Han Qing Li Wenchuan Bi Ran Liu 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第6期860-868,共9页
Pulmonary fibrosis(PF)is an irreversible lung disease that is characterized by excessive scar tissue with a poor median survival rate of 2-3 years.The inhibition of transforming growth factor-β receptor type-I(TGF-β... Pulmonary fibrosis(PF)is an irreversible lung disease that is characterized by excessive scar tissue with a poor median survival rate of 2-3 years.The inhibition of transforming growth factor-β receptor type-I(TGF-β RI)by an appropriate drug may provide a promising strategy for the treatment of this disease.Polygonum cuspidatum(PC)is a well-known traditional Chinese herbal medicine which has an anti-PF effect.Accordingly,a combination of high resolution mass spectrometry with an in silico strategy was developed as a new method to search for potential chemical ingredients of PC that target the TGF-β RI.Based on this strategy,a total of 24 ingredients were identified.Then,absorption,distribution,metabolism,and excretion(ADME)-related properties were subsequently predicted to exclude compounds with potentially undesirable pharmacokinetics behaviour.Molecular docking studies on TGF-β RI were adopted to discover new PF inhibitors.Eventually,a compound that exists in PC known as resveratrol was proven to have excellent biological activity on TGF-β RI,with an IC_(50) of 2.211 μM in vitro.Furthermore,the complex formed through molecular docking was tested via molecular dynamics simulations,which revealed that resveratrol had strong interactions with residues of TGF-β RI.This study revealed that resveratrol has significant potential as a treatment for PF due to its ability to target TGF-β RI.In addition,this research demonstrated the exploration of natural products with excellent biological activities toward specific targets via high resolution mass spectrometry in combination with in silico technology is a promising strategy for the discovery of novel drugs. 展开更多
关键词 Polygonum cuspidatum Pulmonary fibrosis TGF-βreceptor type-I RESVERATROL high resolution mass spectrometry Molecular docking
下载PDF
Software-aided detection and structural characterization of cyclic peptide metabolites in biological matrix by high-resolution mass spectrometry
12
作者 Ming Yao Tingting Cai +3 位作者 Eva Duchoslav Li Ma Xu Guo Mingshe Zhu 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2020年第3期240-246,共7页
Compared to their linear counterparts,cyclic peptides show better biological activities,such as antibacterial,immunosuppressive,and anti-tumor activities,and pharmaceutical properties due to their conformational rigid... Compared to their linear counterparts,cyclic peptides show better biological activities,such as antibacterial,immunosuppressive,and anti-tumor activities,and pharmaceutical properties due to their conformational rigidity.However,cyclic peptides could form numerous putative metabolites from potential hydrolytic cleavages and their fragments are very difficult to interpret.These characteristics pose a great challenge when analyzing metabolites of cyclic peptides by mass spectrometry.This study was to assess and apply a software-aided analytical workflow for the detection and structural characterization of cyclic peptide metabolites.Insulin and atrial natriuretic peptide(ANP)as model cyclic peptides were incubated with trypsin/chymotrypsin and/or rat liver S9,followed by data acquisition using TripleTOF?5600.Resultant full-scan MS and MS/MS datasets were automatically processed through a combination of targeted and untargeted peak finding strategies.MS/MS spectra of predicted metabolites were interrogated against putative metabolite sequences,in light of a,b,y and internal fragment series.The resulting fragment assignments led to the confirmation and ranking of the metabolite sequences and identification of metabolic modification.As a result,29 metabolites with linear or cyclic structures were detected in the insulin incubation with the hydrolytic enzymes.Sequences of twenty insulin metabolites were further determined,which were consistent with the hydrolytic sites of these enzymes.In the same manner,multiple metabolites of insulin and ANP formed in rat liver S9 incubation were detected and structurally characterized,some of which have not been previously reported.The results demonstrated the utility of software-aided data processing tool in detection and identification of cyclic peptide metabolites. 展开更多
关键词 Atrial natriuretic peptide Metabolism of cyclic peptide high resolution mass spectrometry INSULIN Software-aided data processing
下载PDF
High Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometric Analysis of Bilobalide and Ginkgolides in Ginkgo biloba L. Leaves 被引量:1
13
作者 卢定强 韦萍 +1 位作者 欧阳平凯 陈钧 《Journal of Chinese Pharmaceutical Sciences》 CAS 2002年第2期26-30,共5页
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi... The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy. 展开更多
关键词 high performance liquid chromatography Electrospray ionization mass spectrometry Ginkgo terpene lactones
下载PDF
Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study 被引量:2
14
作者 Ravi Kumar Konda Babu Rao Chandu +1 位作者 B.R.Challa Chandrasekhar B.Kothapalli 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期342-349,共8页
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo... The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. 展开更多
关键词 high performance liquid chromatography mass spectrometry RASAGILINE Liquid-liquid extraction
下载PDF
Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods 被引量:1
15
作者 Cheng-Ping Li1,2,Mao Mao1,Lan-Jun Zheng1,Wei-Guang Shan11.College of Pharmaceutical Sciences,Zhejiang University of Technology,Hangzhou 310032 2.College of Biology and Environment Engineering,Zhejiang Shuren University,Hangzhou 310015,China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第4期218-222,共5页
Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 co... Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine. 展开更多
关键词 GANCICLOVIR related substances high performance liquid chromatography high performance liquid chromatography/mass spectrometry
下载PDF
Metabolomic Studies Using High Performance Liquid Chromatography and Tandem Mass Spectrometry to Discover Quality Markers for Oriental Beauty (Dongfang Meiren) Tea 被引量:1
16
作者 Yi-Hong Chen Yu-Hui Liu +1 位作者 Yi-Jhen Wu Chu-Chin Chen 《Food and Nutrition Sciences》 2014年第9期823-834,共12页
In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Pr... In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Principle component analysis (PCA) of the profiling data was performed for pattern recognition, clearly showing that the proposed MS profiling method was able to classify Oriental Beauty tea into different grades. The component mass ions primarily responsible for the separation were selected with high loading strength in the PCA for subsequent identification with tandem mass (MS/MS). Caffeine, citrate and salicylate were verified, whereas certain other compounds remained ambiguous. Regression analysis considering caffeine, citrate and salicylate showed a linear relationship between the prices of the Oriental Beauty tea with an adjusted R2 of 0.84. If all the selected marker ions (in addition to caffeine, citrate and salicylate) could have been identified and incorporated into regression analysis, a stronger relationship could have been confirmed. These results suggest that metabolomics can facilitate the determination of real markers in the quality control of Oriental Beauty tea, and may lead to the further application of metabolomics in other food quality controls. 展开更多
关键词 Dongfang Meiren high Performance Liquid chromatography mass spectrometry Metabolic Profiling Metabolomics ORIENTAL BEAUTY QUALITY TEA
下载PDF
Chemical Components of Achyranthes bidentata Leaves by Ultra High Performance Liquid Chromatography-Mass Spectrometry 被引量:1
17
作者 Haiyang DONG Jinshuo MA Fulin YAN 《Medicinal Plant》 CAS 2019年第4期16-19,共4页
[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c... [Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A. 展开更多
关键词 Achyranthes bidentata LEAVES ULTRA high performance liquid chromatography-mass spectrometry (UHPLC-MS) Chemical components Inokosterone
下载PDF
Modernization of Chinese herbal compound and the high performance liquid chromatography tandem mass spectrometry (HPLC-MS)
18
作者 LI Wen-lan1,2,3,SUN Zhi1,2,DU Juan1,2(1.Engineering Research Center of natural antineoplastic drugs,Ministry of Education,Harbin 150076,China 2.Center of Research and Development on Life Sciences and Environmental Sciences,Harbin University of Commerce,Harbin 150076,China 3.Institute of Materia Medica and Postdoctoral Programme of Harbin University of Commerce,Harbin 150076,China) 《沈阳药科大学学报》 CAS CSCD 北大核心 2008年第S1期119-119,共1页
Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is ... Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound.In order to give full play to the advantages of Chinese herbal compound,modern scientific and technological is used to research of Chinese herbal compound,especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS),because it is high sensitive,rapid,and obtain more information.It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound,and endow traditional Chinese medicine with modern scientific connotation. 展开更多
关键词 MODERNIZATION of Chinese HERBAL compound the high performance liquid chromatography tandem mass spectrometry(HPLC-MS)
下载PDF
Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry
19
作者 Lech RODZIEWICZ Jolanta MASLOWIECKA +1 位作者 Anna SADOWSKA Halina CAR 《色谱》 CAS CSCD 北大核心 2017年第10期1048-1054,共7页
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC... Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine. 展开更多
关键词 ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) thyreostats (TSs) URINE
下载PDF
Determination of 24 Allergens in Perfume with High Performance Liquid Chromatography Tandem Mass Spectrometry
20
作者 Wang Yujian Liang Zhengang +1 位作者 Fu Lingmei Dong Cunzhu 《China Detergent & Cosmetics》 2019年第1期40-46,共7页
A method of 24 allergens determination in cosmetics were established with high performance liquid chromatography tandem mass spectrometry. The targeted compounds were extracted with acetonitrile and determined with LC... A method of 24 allergens determination in cosmetics were established with high performance liquid chromatography tandem mass spectrometry. The targeted compounds were extracted with acetonitrile and determined with LC-MS/MS (MRM mode) with external method. The linearity between concentrations and peak area ratio was obtained from 1.0~5.0 mg/L. The limits of detection were 1.0 mg/L for the instrument and 5.0 mg/kg for the method respectively. The LOQ was 15.0 mg/L. The average recoveries of 24 allergens were between 85.9% and 110.0% at spiked levels of 5, 10 and 20 mg/kg with relative standard derivation (RSDs) of 5.5%~12.0%(n=10). The method could be used as a reliable means for simultaneous quantitative determination of allergens in cosmetics. 展开更多
关键词 PERFUME allergens FLAVOR high performance liquid chromatography TANDEM mass spectrometry
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部