This paper presents an analysis based on analytical method for solid rotor motors for determining the rotor eddy current losses due to the current harmonics of the stator winding. The accuracy of the analytical result...This paper presents an analysis based on analytical method for solid rotor motors for determining the rotor eddy current losses due to the current harmonics of the stator winding. The accuracy of the analytical results is verified by experiments.展开更多
Torque tripple has significant effect on performance of permanent magnet brushless DC motor. This paper presents a mathematical model built for such a motor, the analysis of torque tripple for a brushless DC motor wit...Torque tripple has significant effect on performance of permanent magnet brushless DC motor. This paper presents a mathematical model built for such a motor, the analysis of torque tripple for a brushless DC motor with sinusoidal flux distribution, which is verified by torque tripple experiments run with a test motor, and equations developed for torque tripple resulting from different sator current errors.展开更多
A power system structure composed of a brushless DC motor and a cycloidal reducer for electric balanced vehicle has been proposed, and the temperature of important components in this structure would be discussed. The ...A power system structure composed of a brushless DC motor and a cycloidal reducer for electric balanced vehicle has been proposed, and the temperature of important components in this structure would be discussed. The loss generated by the cycloid reducer is negligible, it’s only need to analyze the thermal field of motor. Since the temperature change will affect the material properties of the target motor, the electromagnetic and temperature fields, involved in the motor, are selected for coupling calculation to determine whether the final temperature distribution can meet the requirements of vehicle for use.展开更多
Split ratio,i.e.the ratio of stator inner diameter to outer diameter,has a closed relationship with electromagnetic performance of permanent magnet(PM)motors.In this paper,the toroidal windings with short end-winding ...Split ratio,i.e.the ratio of stator inner diameter to outer diameter,has a closed relationship with electromagnetic performance of permanent magnet(PM)motors.In this paper,the toroidal windings with short end-winding axial length are employed in the 6-slot/2-pole(6s/2p)PM motor for high speed applications.The split ratio is optimized together with the ratio of inner slot to outer slot area,i.e.slot ratio,considering stator total loss(stator iron loss and copper loss).In addition,the influence of maximum stator iron flux density and tooth-tip on the optimal split ratio,slot ratio,and average torque is investigated.The analytical predictions show that when the slot ratio is 0.5,the maximum torque can be achieved,and the optimal split ratio increases with the decrease of slot ratio,as confirmed by the finite element(FE)analyses.Finally,some of predicted results are verified by the measured results of 6s/2p prototype motor with 0.5 slot ratio.展开更多
The torque-speed characteristics of brushless motor having an interior permanent magnet rotor and a sinusoidal back-emf waveform are compared experimentally when it is operated in brushless AC(BLAC) mode and brushless...The torque-speed characteristics of brushless motor having an interior permanent magnet rotor and a sinusoidal back-emf waveform are compared experimentally when it is operated in brushless AC(BLAC) mode and brushless DC (BLDC) modes with both 2-phase,120° conduction(BLDC-120) and 3-phase,180° conduction(BLDC-180).Particular emphasis is on high-speed,six-step voltage controlled,flux-weakening operation.It is shown that for EV/HEV applications,even for interior PM brushless motors which have sinusoidal back-emf waveforms,in order to achieve maximum torque per ampere capability over wide operation speed range,it is advantageous to employ a hybrid operation mode-BLAC operation in the constant torque region and six-step voltage control(BLDC-180 operation,together with current phase control) in the flux-weakening region.展开更多
We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor(PMSM). In the system, two identical high-speed PMSMs are used as the motor under test(MUT)and the...We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor(PMSM). In the system, two identical high-speed PMSMs are used as the motor under test(MUT)and the load machine(LM),respectively.A new sensorless vector control(VC) method based on a hypothetical reference frame is presented to control both the MUT and the LM.Also,a regenerating unit is used to implement energy circulation to save energy.Experiments were carried out on a prototype, with a digital controller based on the TMS320 F28335, to verify the adequacy of the sensorless VC method.As a result,the efficiency test system achieves the load test at the speed of 21000 r/min without any reduction equipment. During the test, the energy regenerated by the LM could be fed back to the MUT by the regenerating unit, and 81.31% electrical power was saved.In addition, with the proposed sensorless VC method,both the MUT and the LM can work at i_d = 0 without a position sensor.展开更多
文摘This paper presents an analysis based on analytical method for solid rotor motors for determining the rotor eddy current losses due to the current harmonics of the stator winding. The accuracy of the analytical results is verified by experiments.
文摘Torque tripple has significant effect on performance of permanent magnet brushless DC motor. This paper presents a mathematical model built for such a motor, the analysis of torque tripple for a brushless DC motor with sinusoidal flux distribution, which is verified by torque tripple experiments run with a test motor, and equations developed for torque tripple resulting from different sator current errors.
文摘A power system structure composed of a brushless DC motor and a cycloidal reducer for electric balanced vehicle has been proposed, and the temperature of important components in this structure would be discussed. The loss generated by the cycloid reducer is negligible, it’s only need to analyze the thermal field of motor. Since the temperature change will affect the material properties of the target motor, the electromagnetic and temperature fields, involved in the motor, are selected for coupling calculation to determine whether the final temperature distribution can meet the requirements of vehicle for use.
文摘Split ratio,i.e.the ratio of stator inner diameter to outer diameter,has a closed relationship with electromagnetic performance of permanent magnet(PM)motors.In this paper,the toroidal windings with short end-winding axial length are employed in the 6-slot/2-pole(6s/2p)PM motor for high speed applications.The split ratio is optimized together with the ratio of inner slot to outer slot area,i.e.slot ratio,considering stator total loss(stator iron loss and copper loss).In addition,the influence of maximum stator iron flux density and tooth-tip on the optimal split ratio,slot ratio,and average torque is investigated.The analytical predictions show that when the slot ratio is 0.5,the maximum torque can be achieved,and the optimal split ratio increases with the decrease of slot ratio,as confirmed by the finite element(FE)analyses.Finally,some of predicted results are verified by the measured results of 6s/2p prototype motor with 0.5 slot ratio.
文摘The torque-speed characteristics of brushless motor having an interior permanent magnet rotor and a sinusoidal back-emf waveform are compared experimentally when it is operated in brushless AC(BLAC) mode and brushless DC (BLDC) modes with both 2-phase,120° conduction(BLDC-120) and 3-phase,180° conduction(BLDC-180).Particular emphasis is on high-speed,six-step voltage controlled,flux-weakening operation.It is shown that for EV/HEV applications,even for interior PM brushless motors which have sinusoidal back-emf waveforms,in order to achieve maximum torque per ampere capability over wide operation speed range,it is advantageous to employ a hybrid operation mode-BLAC operation in the constant torque region and six-step voltage control(BLDC-180 operation,together with current phase control) in the flux-weakening region.
基金supported by the Science and Technology Project of State Grid Corporation, ‘‘Research on Key Technologies of Flexible Control Strategy for Variable Speed Pumped Storage Units’’the Fundamental Research Funds for the Central Universities (No. B18020574)
文摘We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor(PMSM). In the system, two identical high-speed PMSMs are used as the motor under test(MUT)and the load machine(LM),respectively.A new sensorless vector control(VC) method based on a hypothetical reference frame is presented to control both the MUT and the LM.Also,a regenerating unit is used to implement energy circulation to save energy.Experiments were carried out on a prototype, with a digital controller based on the TMS320 F28335, to verify the adequacy of the sensorless VC method.As a result,the efficiency test system achieves the load test at the speed of 21000 r/min without any reduction equipment. During the test, the energy regenerated by the LM could be fed back to the MUT by the regenerating unit, and 81.31% electrical power was saved.In addition, with the proposed sensorless VC method,both the MUT and the LM can work at i_d = 0 without a position sensor.