期刊文献+
共找到8,837篇文章
< 1 2 250 >
每页显示 20 50 100
FAILURE MODE AND CONSTITUTIVE MODEL OF PLAIN HIGH-STRENGTH HIGH-PERFORMANCE CONCRETE UNDER BIAXIAL COMPRESSION AFTER EXPOSURE TO HIGH TEMPERATURES 被引量:2
1
作者 Zhenjun He Yupu Song 《Acta Mechanica Solida Sinica》 SCIE EI 2008年第2期149-159,共11页
An orthotropic constitutive relationship with temperature parameters for plain highstrength high-performance concrete (HSHPC) under biaxial compression is developed. It is based on the experiments performed for char... An orthotropic constitutive relationship with temperature parameters for plain highstrength high-performance concrete (HSHPC) under biaxial compression is developed. It is based on the experiments performed for characterizing the strength and deformation behavior at two strength levels of HSHPC at 7 different stress ratios including a=σs : σ3=0.00:-1,-0.20:-1,-0.30 : -1,-0.40:-1,-0.50:-1,-0.75:-1,-1.00:-1, after the exposure to normal and high temperatures of 20, 200, 300, 400, 500 and 600℃, and using a large static-dynamic true triaxial machine. The biaxial tests were performed on 100 mm×100 mm×100 mm cubic specimens, and friction-reducing pads were used consisting of three layers of plastic membrane with glycerine in-between for the compressive loading plane. Based on the experimental results, failure modes of HSHPC specimens were described. The principal static compressive strengths, strains at the peak stress and stress-strain curves were measured; and the influence of the temperature and stress ratios on them was also analyzed. The experimental results showed that the uniaxial compressive strength of plain HSHPC after exposure to high temperatures does not decrease dramatically with the increase of temperature. The ratio of the biaxial to its uniaxial compressive strength depends on the stress ratios and brittleness-stiffness of HSHPC after exposure to different temperature levels. Comparison of the stress-strain results obtained from the theoretical model and the experimental data indicates good agreement. 展开更多
关键词 high-strength high-performance concrete (HSHPC) high temperatures uniaxial biaxial compressive strength failure criterion stress-strain relationship
下载PDF
A Study on the Bond Strength between High Performance Concrete and Reinforcing Bar 被引量:2
2
作者 Eun Suk Choi Jung Woo Lee +1 位作者 Seong Jun Kim Jong Won Kwark 《Engineering(科研)》 2015年第7期373-378,共6页
As a preliminary study for the erection of floating structures using high performance concrete, this paper examines the bond characteristics between concrete and the reinforcing bar. Since the floating structure is co... As a preliminary study for the erection of floating structures using high performance concrete, this paper examines the bond characteristics between concrete and the reinforcing bar. Since the floating structure is constructed in aquatic environment, corrosion of the reinforcing steel is likely to develop more prematurely than in onshore structure in case of concrete cracking. A solution to this corrosion problem could use FRP rebar instead of steel reinforcement. To that goal, an experimental study is conducted on the concrete-FRP bond strength to verify if such FRP rebar develops performance comparable to the conventional steel rebar. A series of tests are performed considering the bond length of ordinary steel rebar and G-FRP rebar as test variable with respect to the strength of concrete, and the results are presented. 展开更多
关键词 FRP REINFORCEMENT high performance concrete BOND strength concrete strength BOND LENGTH
下载PDF
Strength Regularity and Failure Criterion of High-Strength High-Performance Concrete under Multiaxial Compression 被引量:1
3
作者 何振军 宋玉普 《Journal of Southwest Jiaotong University(English Edition)》 2008年第2期144-149,共6页
Multiaxial compression tests were performed on 100 mm×100 mm×100 mm high-strength high-performance concrete (HSI-IPC) cubes and normal strength concrete (NSC) cubes. The failure modes of specimens were p... Multiaxial compression tests were performed on 100 mm×100 mm×100 mm high-strength high-performance concrete (HSI-IPC) cubes and normal strength concrete (NSC) cubes. The failure modes of specimens were presented, the static compressive strengths in principal directions were measured, the influence of the stress ratios was analyzed. The experimental results show that the ultimate strengths for HSHPC and NSC under multiaxial compression are greater than the uniaxial compressive strengths at all stress ratios, and the multiaxial strength is dependent on the brittleness and stiffness of concrete, the stress state and the stress ratios. In addition, the Kupfer-Gersfle and Ottosen's failure criteria for plain HSHPC and NSC under multiaxial compressive loading were modified. 展开更多
关键词 high-strength high-performance concrete (HSHPC) Normal strength concrete (NSC) Stress ratio Multiaxial corn- pressive slxength Failure criterion
下载PDF
Properties of Sustainable High Strength Concrete with Waste Copper Slag
4
作者 JAGAN Sivamani KARUPASAMY Narayanan +3 位作者 DHARMARAJ R THIYANESWARAN Periyasamy KARTHIKEYAN Selvarajan NAVANEETHAN Kumaravalasu Subramaniam 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2023年第4期815-822,共8页
The present work investigates copper slag as a substitute for river sand in high-strength concrete.The concrete mixtures were manufactured with 10%,30%,50%,70%,and 100%of copper slag to evaluate the mechanical and dur... The present work investigates copper slag as a substitute for river sand in high-strength concrete.The concrete mixtures were manufactured with 10%,30%,50%,70%,and 100%of copper slag to evaluate the mechanical and durability properties.The experimental results indicate that replacing copper slag above 50%affects the performance characteristics of the concrete due to its high angularity and lower water absorption characteristics.The strength of concrete with 50%copper slag is improved by 5.6%,whereas the strength of concrete with 100%copper slag is reduced by 2.75%at 28 days.However,increased curing to 90days improves the strength of the former by 7.16%and reduces the latter by only 0.23%.The water absorption,porosity,and rapid chloride penetration of the concrete mixtures with 100%copper slag are increased by 10.44%,13.20%,and 19.56%compared to control concrete.Micro-structural investigations through SEM infer higher replacement of copper results in higher void formation due to its reduced water absorption. 展开更多
关键词 copper slag high strength concrete strength water absorption POROSITY
下载PDF
Effect of SAP on Properties of High Performance Concrete under Marine Wetting and Drying Cycles 被引量:4
5
作者 Ouattara Coumoin Cherel WANG Fazhou +1 位作者 YANG Jin 刘志超 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2019年第5期1136-1142,共7页
The internal curing effect of superabsorbent polymer(SAP) on the properties of high performance concrete(HPC) under marine wetting and drying cycles(WD cycles) was investigated. Compressive strength, hydration and chl... The internal curing effect of superabsorbent polymer(SAP) on the properties of high performance concrete(HPC) under marine wetting and drying cycles(WD cycles) was investigated. Compressive strength, hydration and chloride migration were experimentally investigated and the results were evaluated by compasison with those under fresh water curing(FW). Water absorption and porosity were also evaluated only under WD cycles. The results showed the important influence of wetting and drying cycles on the properties of SAP modified HPC properties. Carefully designed, SAP minimized the long-term compressive strength of HPC under marine WD cycles. The hydration rate was faster in the initial curing, but became lower as compared with that cured in FW. In addition, SAP improved the long-term water absorption resistance and chloride migration resistance of HPC under marine WD cycles. The examination of the porosity showed a lower increase of the volume of capillary pores in SAP modified HPC under long term WD cycles compared with that without SAP. Therefore, internal curing by SAP could improve the durability properties of HPC under marine WD cycles. 展开更多
关键词 SUPERABSORBENT polymer(SAP) high performance concrete WETTING and DRYING cycles internal CURING
下载PDF
Seismic performance of steel reinforced ultra high-strength concrete composite frame joints 被引量:5
6
作者 Yan Changwang Jia Jinqing 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第3期439-448,共10页
To investigate the seismic performance of a composite frame comprised of steel reinforced ultra high-strength concrete (SRUHSC) columns and steel reinforced concrete (SRC) beams, six interior frame joint specimens... To investigate the seismic performance of a composite frame comprised of steel reinforced ultra high-strength concrete (SRUHSC) columns and steel reinforced concrete (SRC) beams, six interior frame joint specimens were designed and tested under low cyclically lateral load. The effects of the axial load ratio and volumetric stirrup ratio were studied on the characteristics of the frame joint performance including crack pattern, failure mode, ductility, energy dissipation capacity, strength degradation and rigidity degradation. It was found that all joint specimens behaved in a ductile manner with flexural-shear failure in the joint core region while plastic hinges appeared at the beam ends. The ductility and energy absorption capacity of joints increased as the axial load ratio decreased and the volumetric stirIup ratio increased. The displacement ductility coefficient and equivalent damping coefficient of the joints fell between the corresponding coefficients of the steel reinforced concrete (SRC) frame joint and RC frame joint. The axial load ratio and volumetric stirrup ratio have less influence on the strength degradation and more influence on the stiffness degradation. The stiffness of the joint degrades more significantly for a low volumetric stirrup ratio and high axial load ratio. The characteristics obtained from the SRUHSC composite frame joint specimens with better seismic performance may be a useful reference in future engineering applications. 展开更多
关键词 cyclical test axial load ratio volumetric stirrup ratio DUCTILITY strength degradation stiffness degradation steel reinforced ultra high strength concrete beam-column joint
下载PDF
Influence of MB-value of Manufactured Sand on the Shrinkage and Cracking of High Strength Concrete 被引量:4
7
作者 王稷良 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2009年第2期321-325,共5页
The relation between methylene blue (MB) value of MS and its limestone dust content and clay content was investigated. The effects of MB value ranging from 0.35 to 2.5 on the workability of fresh concrete and crack ... The relation between methylene blue (MB) value of MS and its limestone dust content and clay content was investigated. The effects of MB value ranging from 0.35 to 2.5 on the workability of fresh concrete and crack propagation characteristics at the age of 24 hours, and effects on the mechanical properties, dry shrinkage of the harden concrete were tested. The experimental results show that the MB value is not related with the limestone dust content of MS, but in direct proportion to clay content. With the increase of MB value, the concrete workability decreases, and the flexural strength and 7 d compressive strength reduce markedly, whearas the 28 d compressive strength is not affected. When the MB-value is less than or equal to 1.35, the change of the MB-value has a little influence on early plastic cracking and dry shrinkage property of concrete, but when the MB-value is more than 1.35, the tendency of plastic cracking and dry shrinkage is remarkable. 展开更多
关键词 manufactured sand methylene blue value high strength concrete anti-cracking SHRINKAGE
下载PDF
Characterization of Surface Hardness and Microstructure of High Performance Concrete 被引量:3
8
作者 杨永敢 张云升 SHE Wei 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2018年第1期124-132,共9页
The relationship between compressive strength obtained by universal testing machine and rebound value obtained by the hammer of high performance concrete was systematically investigated at the macro level. And a model... The relationship between compressive strength obtained by universal testing machine and rebound value obtained by the hammer of high performance concrete was systematically investigated at the macro level. And a model of high performance concrete strength curve was established from them. At the micro level, the microstructure, hydration products and pore structure of concrete surface were analyzed by scanning electron microscopy(SEM), comprehensive thermal analysis(TG-DSC) and mercury intrusion porosimetry(MIP), respectively. The effect of carbonation on surface strength was also investigated. The results showed that the concrete surface hardness layer grew rapidly at early stage and then stabilized at last with ongoing curing age; the rebound value and compressive strength of concrete with slag were higher than those of concrete with the same content of fly ash. In addition, the strength curve obtained by the least square method can satisfy the local standard requirements with an average relative error of 8.9% and a relative standard deviation of 11.3%. When the carbonation depth was 6 mm, the compressive strength calculated by national uniform strength curve was 25 PMa higher than that by high performance concrete. 展开更多
关键词 high performance concrete rebound test parameter analysis strength curve
下载PDF
High Performance Concrete and Its Typical Mixes 被引量:3
9
作者 Cai Yuebo , Kwan Kwokhung , Cheung Yaukai Chan Honchuen Senior Engineer, Material and Structure Department, Nanjing Hydraulic Research Institute, Nanjing 210024 P. H. Doctor, Department of Civil and Structural Engineering, University of Hong Kong Professor, Department of Civil and Structural Engineering, University of Hong Kong 《China Ocean Engineering》 SCIE EI 1995年第3期335-344,共10页
With the modern development of chemical and mineral admixtures, it is now possible to produce much higher performance concrete than before. Higher performance does not only mean higher strength, but also better durabi... With the modern development of chemical and mineral admixtures, it is now possible to produce much higher performance concrete than before. Higher performance does not only mean higher strength, but also better durability, lower risk of thermal cracking and higher dimensional stability etc. The three most effective admixtures for producing high performance concrete are superplastieizer, pulverized fuel ash and condensed silica fume. This paper outlines the properties of these materials and presents some practical guidelines for their usage. 展开更多
关键词 high performance concrete SUPERPLASTICIZER pulverized fuel ash condensed silica fume typical mixes
下载PDF
Residual Mechanical Properties and Explosive Spalling Behavior of Ultra-High-Strength Concrete Exposed to High Temperature 被引量:2
10
作者 Gaifei Peng Juan Yang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2017年第4期62-70,共9页
In order to explore the characteristics of ultra-high-strength concrete exposed to high temperature,residual mechanical properties and explosive spalling behavior of ultra-high-strength concrete( UHSC) and high streng... In order to explore the characteristics of ultra-high-strength concrete exposed to high temperature,residual mechanical properties and explosive spalling behavior of ultra-high-strength concrete( UHSC) and high strength concrete( HSC) exposed to high temperatures ranging from 20 ℃ to 800 ℃ were determined. The microstructure of the specimens after exposure to elevated temperature was analyzed by means of scanning electron microscope( SEM) and mercury intrusion porosimetry( MIP). The residual compressive strengths of UHSC and HSC were first increased and then decreased as temperature increased. After exposure to 800 ℃,the compressive strengths of UHSC and HSC were 24. 2 % and 22. 3 % of their original strengths at 20 ℃,respectively. The residual splitting tensile strengths of both UHSC and HSC were consistently decreased with the temperature increasing and were approximately 20% of their original strengths after 800 ℃. However,the residual fracture energies of both concretes tended to ascend even at 600 ℃. The explosive spalling of UHSC was more serious than that of HSC. Moisture content of the specimens governs the explosive spalling of both concretes with a positive correlations,and it is more pronounced in UHSC. These results suggest that UHSC suffers a substantial loss in load-bearing capacity and is highly prone to explosive spalling due to high temperature. The changes in compressive strength are due to the changes in the density and the pore structure of concrete. The probability and severity of explosive spalling of UHSC are much higher than those of HSC due to the higher pore volume in HSC. 展开更多
关键词 ultra-high-strength concrete high strength concrete RESIDUAL mechanical properties EXPLOSIVE SPALLING
下载PDF
Combined effect of steel fibres and steel rebars on impact resistance of high performance concrete 被引量:9
11
作者 陈相宇 丁一宁 C.Azevedo 《Journal of Central South University》 SCIE EI CAS 2011年第5期1677-1684,共8页
The impact properties of normal concrete (NC) and reinforced concrete (RC) specimens,steel fibre reinforced concrete (SFRC) specimens and RC+SFRC specimens with different steel fibre dosages were investigated with the... The impact properties of normal concrete (NC) and reinforced concrete (RC) specimens,steel fibre reinforced concrete (SFRC) specimens and RC+SFRC specimens with different steel fibre dosages were investigated with the drop-weight impact test recommended by ACI Committee 544.The results indicate that the number of blows to final failure is greatly increased by addition of steel fibres.Moreover,the combination of steel fibres and steel rebars demonstrates a significant positive composite effect on the impact resistance,which results in the improvement in impact toughness of concrete specimens.In the view of variation of impact test results,the two-parameter Weibull distribution was adopted to analyze the experimental data.It is proved that the probabilistic distributions of the blows to first crack and to final failure of six types of samples approximately follow two-parameter Weibull distribution. 展开更多
关键词 钢纤维钢筋混凝土 钢纤维混凝土 高性能混凝土 耐冲击 WEIBULL分布 合作 普通混凝土 混凝土试件
下载PDF
Evaluation of the Shear Strength of Perfobond Rib Connectors in Ultra High Performance Concrete 被引量:4
12
作者 Jae Yoon Kang Jong Sup Park +1 位作者 Woo Tai Jung Moon Seoung Keum 《Engineering(科研)》 2014年第13期989-999,共11页
Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is perf... Since the previous strength prediction models for the perfobond rib connector were proposed based upon the results of push-out tests conducted on concretes with compressive strength below 50 MPa, push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action. The comparison with the predictions obtained by the previous models shows that the experimental results are close to the values given by the model proposed by Oguejiofor and Hosain [1]. 展开更多
关键词 Perfobond RIB CONNECTOR Ultra high performance concrete Push-Out Test SHEAR strength
下载PDF
Performances of the High Strength Low Heat Pump Concrete (HLPC) 被引量:1
13
作者 张云升 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2002年第3期56-59,共4页
The effects of mineral admixtures on fluidity,mechanical and hydrational exothermic behavior were studied.The results show that,double adding ways,i e,fly ash and slag were added at the same time,not only improves th... The effects of mineral admixtures on fluidity,mechanical and hydrational exothermic behavior were studied.The results show that,double adding ways,i e,fly ash and slag were added at the same time,not only improves the fluidity of fresh concrete with low W/B and compensates the lower early compressive strength of harden concrete caused by high adding amount of fly ash, but also greatly reduces the highest temperature rise, exothermic rate and total heat liberation of 3 day of binder pastes in HLPC, and postponed the arrival time of the highest temperature rise. HLPC was prepared and applied to project practice successfully. 展开更多
关键词 mineral admixtures double adding ways high strength PUMP low hydration heat concrete
下载PDF
Mechanical Properties and Flowability of High Strength Concrete Incorporating Ground Granulated Blast-furnace Slag 被引量:1
14
作者 姚武 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2001年第3期42-45,共4页
The high strength concrete(HSC)was produced by partially replacingthe normal portland cement with special ground granulatedblast-furnace slag(GGBS)ranging up to 60/100. The effects of the GGBSon the flowabilityand mec... The high strength concrete(HSC)was produced by partially replacingthe normal portland cement with special ground granulatedblast-furnace slag(GGBS)ranging up to 60/100. The effects of the GGBSon the flowabilityand mechanical properties of HSC were studied. Thehydration process and microstructure char- acteristics wereinvestigated by X-ray diffraction(XRD)and scanning microscopy(SEM),respectively. The test results indicate that the GGBS has especiallysupplementary effect on water reducing and excellent property Ofbetter control of lump loss. 展开更多
关键词 high strength concrete mechanical property FLOWABILITY
下载PDF
Influence of shrinkage-reducing admixture on drying shrinkage and mechanical properties of high-performance concrete 被引量:5
15
作者 Nguyen Quangphu Jiang Linhua +2 位作者 Liu Jiaping Tian Qian Do Tienquan 《Water Science and Engineering》 EI CAS 2008年第4期67-74,共8页
High-performance concrete (HPC) has specific performance advantages over conventional concrete in strength and durability. HPC mixtures are usually produced with water/binder mass ratios (mW/mB) in the range of 0.... High-performance concrete (HPC) has specific performance advantages over conventional concrete in strength and durability. HPC mixtures are usually produced with water/binder mass ratios (mW/mB) in the range of 0.2-0.4, so volume changes of concrete as a result of drying, chemical reactions, and temperature change cannot be avoided. For these reasons, shrinkage and cracking are frequent phenomena. It is necessary to add some types of admixture for reduction of shrinkage and cracking of HPC. This study used a shrinkage-reducing admixture (SRA) for that purpose. Concrete was prepared with two different mW/mB (0.22 and 0.40) and four different mass fractions of SRA to binder (w(SRA) = 0%, 1%, 2%, and 4%). The mineral admixtures used for concrete mixes were: 25% fly ash (FA) and 25% slag by mass of binder for the mixture with mW/mB = 0.40, and 15% silica fume (SF) and 25% FA for the mixture with mW/mB = 0.22. Tests were conducted on 24 prismatic specimens, and shrinkage strains were measured through 120 days of drying. Compressive strength, splitting strength, and static modulus of elasticity were also determined. The results show that the SRA effectively reduces some mechanical properties of HPC. The reductions in compressive strength, splitting tensile strength, and elastic modulus of the concrete were 7%-24%, 9%-19%, and 5%-12%, respectively, after 90 days, compared to concrete mixtures without SRA. SRA can also help reduce drying shrinkage of concrete. The shrinkage strains of HPC with SRA were only as high as 41% of the average free shrinkage of concrete without SRA after 120 days of drying. 展开更多
关键词 high-performance concrete shrinkage-reducing admixture compressive strength elastic modulus splitting tensile strength drying shrinkage
下载PDF
Design of Eco-friendly Ultra-high Performance Concrete with Supplementary Cementitious Materials and Coarse Aggregate 被引量:4
16
作者 蒋金洋 ZHOU Wenjing +4 位作者 CHU Hongyan WANG Fengjuan WANG Liguo FENG Taotao GUO Dong 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2019年第6期1350-1359,共10页
Aiming to investigate the mix design of eco-friendly UHPC with supplementary cementitious materials and coarser aggregates, we comprehensively studied the workability, microstructure, porosity, compressive strength, f... Aiming to investigate the mix design of eco-friendly UHPC with supplementary cementitious materials and coarser aggregates, we comprehensively studied the workability, microstructure, porosity, compressive strength, flexural strength, and Young’s modulus of UHPC. Relationship between compressive strength and Young’s modulus was obtained eventually. It is found that the compressive strength, flexural strength, and Young’s modulus of UHPC increase by 19.01%, 10.81%, and 5.99%, respectively, when 40 wt% cement is replaced with supplementary cementitious materials. The relationship between compressive strength and Young’s modulus of UHPC is an exponential form. 展开更多
关键词 ultra-high perform ance concrete ECO-FRIENDLY POROSITY compressive strength flexural strength Young’s modulus
下载PDF
Preparation and Application of C60 High Performance Concrete 被引量:1
17
作者 Jizhong Li(Concrete Company of Beijing Urban Construction Group, Heijing 100039, China) 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 1998年第4期241-244,共4页
C60 High Performance Concrete (HPC) was prepared by limiting cement content and adopting compositesuperplasticizer, low-alkalinity expansive agent and high-quality line mixture. The results showed that the performance... C60 High Performance Concrete (HPC) was prepared by limiting cement content and adopting compositesuperplasticizer, low-alkalinity expansive agent and high-quality line mixture. The results showed that the performance of the prepared C60 HPC was excellent. By adopting some advanced construction techniques such as usingsecondary vibration and secondary face compaction, controlling temperature difference and paying special attentionto early curing in the construction process, the prepared C60 HPC had been successfully applied in the monolithicstructure of huge building. 展开更多
关键词 concrete performance construction techniques application of C60 high performance concrete
下载PDF
Influence of Nano-Materials on Mechanical and Permeation Characteristics of High Strength Concrete 被引量:1
18
作者 K V S Gopala Krishna Sastry M Srinivasula Reddy A Ravitheja 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2022年第3期416-422,共7页
Efforts have been made to evaluate the influences of the addition of nanoparticles on the strength,durability and mineralogical changes of high strength concrete(HSC).Therefore,mixes were prepared for conventional con... Efforts have been made to evaluate the influences of the addition of nanoparticles on the strength,durability and mineralogical changes of high strength concrete(HSC).Therefore,mixes were prepared for conventional concrete mix(CCM)of M80 grade.Further,various mixes were prepared by replacing cementitious materials initially with 1%Nano-CaCO_(3)(NC),2%NC,3%NC in the CCM,and then 1%NC and Nano-SiO_(2)(NS)NS,2%NC and NS,3%NC and NS(NC and NS were in equal proportion)in the CCM.The developed concretes were then evaluated for mechanical properties,permeation characteristics,and mineralogical studies.From the studies,it is found that the concrete at 2%NCS possesses superior mechanical and superior permeation characteristics of all the mixes.A clear variation in the mineralogical structure with the addition of nanoparticles has been observed. 展开更多
关键词 high strength concrete nano silicon dioxide nano calcium carbonate mechanical properties permeation properties
下载PDF
Effects of Manufactured-sand on Dry Shrinkage and Crccp of High-strength Concrete 被引量:4
19
作者 ZHOU Mingkai WANG Jiliang ZHU Lide HE Tusheng 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2008年第2期249-253,共5页
The influences of natural sand, manufactured-sand (MS) and stone-dust (SD) in the manufactured-sand on workability, compressive strength, elastic modulus, drying shrinkage and creep properties of high-strength con... The influences of natural sand, manufactured-sand (MS) and stone-dust (SD) in the manufactured-sand on workability, compressive strength, elastic modulus, drying shrinkage and creep properties of high-strength concrete (HSC) were tested and compared. The results show that the reasonable content (7%-10.5%) of SD in MS will not deteriorate the workability of MS-HSC. It could even improve the workability. Moreover, the compressive strength increases gradually with the increasing SD content,and the MS- HSC with low SD content (smaller than 7%) has the elastic modulus which approaches that of the natural sand HSC, but the elastic modulus reduces when the SD content is high. The influence of the SD content on drying shrinkage performance of MS-HSC is closely related to the hydration age. The shrinkage rate of MS-HSC in the former 7 d age is higher than that of the natural sand HSC, but the difference of the shrinkage rate in the late age is not marked. Meanwhile the shrinkage rate reduces as the fly ash is added; the specific creep and creep coefficient of MS-HSC with 7% SD are close to those of the natural sand HSC. 展开更多
关键词 manufactured-sand natural sand high-strength concrete dry shrinkage CREEP
下载PDF
Spalling and Mechanical Properties of Fiber Reinforced High-performance Concrete Subjected to Fire 被引量:3
20
作者 董香军 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2008年第5期743-749,共7页
Spalling and mechanical properties of FRHPC subjected to fire were tested on notched beams. The results confirm that the internal vapor pressure is the leading reason for spalling of high-performance concrete (HPC).... Spalling and mechanical properties of FRHPC subjected to fire were tested on notched beams. The results confirm that the internal vapor pressure is the leading reason for spalling of high-performance concrete (HPC). At the same time, the temperature-increasing velocity and constrained conditions of concrete element also play significant roles in spalling. Steel fibers cannot reduce the risk of spalling, although they have obvious beneficial effects on the mechanical properties of concrete before and after exposure to fire. Polypropylene (PP) fibers are very useful in preventing HPC from spalling, however, they have negative effects on the strengths. By using hybrid fibers (steel fibers+PP fibers), both good anti-spalling performance and improved mechanical properties come true, which may provide necessary safe guarantee for the rescue work and structure repair after fire disaster. 展开更多
关键词 fiber reinforced high-performance concrete (FRHPC) FIRE SPALLING compressive strength flexural toughness
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部