期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Design of TE_(01δ) Test Probe for Measuring the Microwave Surface Resistance of HTS Thin Film
1
作者 Cheng Zeng Zheng-Xiang Luo Qi-Shao Zhang Kai Yang 《Journal of Electronic Science and Technology of China》 2008年第2期212-215,共4页
A new TEo1δ test probe with proper transmission factor is fabricated for the measurement of surface resistance of high temperature superconductor (HTS) thin film. Coupling holes instead of coupling loops are used i... A new TEo1δ test probe with proper transmission factor is fabricated for the measurement of surface resistance of high temperature superconductor (HTS) thin film. Coupling holes instead of coupling loops are used in the probe for its easier machining and relatively low loss. Two 6 mm × 3 mm × 8 mm dielectric waveguides, one side of them is coated by silver, are used for coupling. The measurement result of S21 agrees well with the simulation because the size of the probe can be rigidly controlled by machine. The microwave surface resistance of four YBCO/MgO films are measured at 77 K and 12 GHz and scaled to 10 GHz according to thef2 rule. The average surface resistance of four HTS thin fdms is 0.38 mΩ, the standard deviation and relative standard deviation of one single HTS thin film are 0.009 mΩ and 2.4%, respectively. 展开更多
关键词 high temperature superconductor surface resistance surface resistance measurement.
下载PDF
High sensitivity D-shaped hole fiber temperature sensor based on surface plasmon resonance with liquid filling 被引量:3
2
作者 SIJUN WENG LI PEI +2 位作者 JIANSHUAI WANG TIGANG NING JING LI 《Photonics Research》 SCIE EI 2017年第2期103-107,共5页
A high sensitivity D-shaped hole double-cladding fiber temperature sensor based on surface plasmon resonance(SPR)is designed and investigated by a full-vector finite element method.Within the D-shaped hole doublecladd... A high sensitivity D-shaped hole double-cladding fiber temperature sensor based on surface plasmon resonance(SPR)is designed and investigated by a full-vector finite element method.Within the D-shaped hole doublecladding fiber,the hollow D-section is coated with gold film and then injected in a high thermo-optic coefficient liquid to realize the high temperature sensitivity for the fiber SPR temperature sensor.The numerical simulation results show that the peaking loss of the D-shaped hole double-cladding fiber SPR is hugely influenced by the distance between the D-shaped hole and fiber core and by the thickness of the gold film,but the temperature sensitivity is almost insensitive to the above parameters.When the thermo-optic coefficient is -2.8×10^(-4)∕℃,the thickness of the gold film is 47 nm,and the distance between the D-shaped hole and fiber core is 5μm,the temperature sensitivity of the D-shaped hole fiber SPR sensor can reach to -3.635 nm∕℃. 展开更多
关键词 high sensitivity D-shaped hole fiber temperature sensor based on surface plasmon resonance with liquid filling MODE
原文传递
AlN-based surface acoustic wave resonators on platinum bottom electrodes for high-temperature sensing applications 被引量:2
3
作者 Chuan Li Xing-Zhao Liu +2 位作者 Bin Peng Lin Shu Yan-Rong Li 《Rare Metals》 SCIE EI CAS CSCD 2016年第5期408-411,共4页
Surface acoustic wave(SAW) resonators with Pt/AlN/Si and Pt/AlN/Pt/Si configurations were fabricated by lift-off photolithography techniques. High-temperature performances of both configurations were investigated fo... Surface acoustic wave(SAW) resonators with Pt/AlN/Si and Pt/AlN/Pt/Si configurations were fabricated by lift-off photolithography techniques. High-temperature performances of both configurations were investigated for temperature sensor applications. AlN films grown on Ptcoated Si substrates exhibit a lower(002) preferred orientation than those grown on Si substrates. The center frequencies of Pt/AlN/Si and Pt/AlN/Pt/Si configurations at room temperature are 424.1 and 456.4 MHz, respectively.The SAW was limited by Pt bottom electrodes to propagate in AlN layer. The temperature coefficient of frequency(TCF) values of Pt/AlN/Si and Pt/AlN/Pt/Si configurations are-51.6 × 10^-6 and-69.2 × 10^-6℃^-1, respectively.Compared with that of Pt/AlN/Si configuration, the TCF value of Pt/AlN/Pt/Si configuration decreases by 34.1 %.AlN resonator with the Pt floating bottom electrodes provides a large, quasi-constant temperature sensitivity which is suitable for temperature sensor applications. 展开更多
关键词 AlN film high temperature Platinum temperature coefficient of frequency surface acoustic wave
原文传递
上一页 1 下一页 到第