High-frequency spinal cord stimulation(HF-SCS) has been established as an effective therapy for neuropathic pain. However, the analgesic mechanisms involved in HF-SCS remain to be clarified. In our study, adult rat ne...High-frequency spinal cord stimulation(HF-SCS) has been established as an effective therapy for neuropathic pain. However, the analgesic mechanisms involved in HF-SCS remain to be clarified. In our study, adult rat neuropathic pain was induced by spinal nerve ligation. Two days after modeling, the rats were subjected to 4 hours of HF-SCS(motor threshold 50%, frequency 10,000 Hz, and pulse width 0.024 ms) in the dorsal horn of the spinal cord. The results revealed that the tactile allodynia of spinal nerve-injured rats was markedly alleviated by HFSCS, and the effects were sustained for 3 hours after the stimulation had ceased. HF-SCS restored lysosomal function, increased the levels of lysosome-associated membrane protein 2(LAMP2) and the mature form of cathepsin D(matu-CTSD), and alleviated the abnormally elevated levels of microtubule-associated protein 1 A/B-light chain 3(LC3)-II and sequestosome 1(P62) in spinal nerve-injured rats. HF-SCS also mostly restored the immunoreactivity of LAMP2, which was localized in neurons in the superficial layers of the spinal dorsal horn in spinal nerve-injured rats. In addition, intraperitoneal administration of 15 mg/kg chloroquine for 60 minutes reversed the expression of the aforementioned proteins and shortened the timing of the analgesic effects of HF-SCS. These findings suggest that HF-SCS may exhibit longlasting analgesic effects on neuropathic pain in rats through improving lysosomal dysfunction and alleviating autophagic flux. This study was approved by the Laboratory Animal Ethics Committee of China Medical University, Shenyang, China(approval No. 2017 PS196 K) on March 1, 2017.展开更多
An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system...An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system based on personal computer (PC) is developed hereby. It senses voltage and current in isolation from generators with transformers, and then the measured values are amplified, filtered, transformed into single-ended signals and converted to RMS. The detected signals are transformed into digital signals through Data Acquisition Card (DAQ) and the data are processed with quadratic fit in Labview. Finally, the controller completes constant power output. The experiment results indicate that the energy detection system can measure the output parameters precisely and the controller can achieve constant power control.展开更多
Epilepsy is one of the most common serious neurological disorders. Pharmacoresistant epilepsy patients are poorly controlled or their seizures are refractory to drug treatment. Resective surgery is frequently a promis...Epilepsy is one of the most common serious neurological disorders. Pharmacoresistant epilepsy patients are poorly controlled or their seizures are refractory to drug treatment. Resective surgery is frequently a promising therapy in this population, however, not all the patients meet the eligibility criteria for the surgical treatment. Deep brain stimulation has been investigated in clinical studies and animal studies as an alternative treatment, but the optimal stimulation parameters remain an issue. The present study was designed to investigate the effect of unilateral high-frequency stimulation (HFS) of hippocampus on seizure development by using the hippocampal rapid kindling method (hRK) in rats, and compared the results with those of low-frequency stimulation previously published by our group. We used male Wistar rats implanted with electrodes in the ventral hippocampus. All rats underwent hRK (biphasic square wave pulses, 20 Hz for 10 seconds) during three consecutive days (twelve stimulations per day). The control group (hRK;n = 7) received only RK stimulus, while the treated group (HFS-hRK;n = 9) received also HFS (biphasic square wave pulses, 130 Hz for 30 seconds) immediately before the RK stimulus, during three consecutive days. At the end of behavioral testing 78% (p 0.01) of the animals receiving HFS treatment were still not fully kindled staying in stages 0 -III (p 0.01). HFS group needed a higher number of stimulations to achieve stage III (p 0.05) with respect to control group. However, no significant differences in the cumulative daily afterdischarge duration were observed. HFS did not present significant differences compared with LFS in any of studied parameters. The findings suggest that unilateral HFS applied on hippocampus effectively inhibited the epileptogenic process induced by hippocampal rapid kindling. According to the comparative results about hippocampal rapid kindled animals stimulated with HFS and LFS (5 Hz), we found no conclusive information on which treatment is most efficient.展开更多
The total electricity consumption(TEC)can accurately reflect the operation of the national economy,and the forecasting of the TEC can help predict the economic development trend,as well as provide insights for the for...The total electricity consumption(TEC)can accurately reflect the operation of the national economy,and the forecasting of the TEC can help predict the economic development trend,as well as provide insights for the formulation of macro policies.Nowadays,high-frequency and massive multi-source data provide a new way to predict the TEC.In this paper,a"seasonal-cumulative temperature index"is constructed based on high-frequency temperature data,and a mixed-frequency prediction model based on multi-source big data(Mixed Data Sampling with Monthly Temperature and Daily Temperature index,MIDAS-MT-DT)is proposed.Experimental results show that the MIDAS-MT-DT model achieves higher prediction accuracy,and the"seasonal-cumulative temperature index"can improve prediction accuracy.展开更多
基金supported by the National Nature Science Foundation of China,No.81870838Liaoning Province Distinguished Professor Support Program of China,No.XLYC1802096+1 种基金Shenyang Clinical Medicine Research Center of Anesthesiology of China,Nos.19-110-4-24,20-204-4-44the Outstanding Scientific Foundation of Shengjing Hospital of China,No.201708(all to PZ)。
文摘High-frequency spinal cord stimulation(HF-SCS) has been established as an effective therapy for neuropathic pain. However, the analgesic mechanisms involved in HF-SCS remain to be clarified. In our study, adult rat neuropathic pain was induced by spinal nerve ligation. Two days after modeling, the rats were subjected to 4 hours of HF-SCS(motor threshold 50%, frequency 10,000 Hz, and pulse width 0.024 ms) in the dorsal horn of the spinal cord. The results revealed that the tactile allodynia of spinal nerve-injured rats was markedly alleviated by HFSCS, and the effects were sustained for 3 hours after the stimulation had ceased. HF-SCS restored lysosomal function, increased the levels of lysosome-associated membrane protein 2(LAMP2) and the mature form of cathepsin D(matu-CTSD), and alleviated the abnormally elevated levels of microtubule-associated protein 1 A/B-light chain 3(LC3)-II and sequestosome 1(P62) in spinal nerve-injured rats. HF-SCS also mostly restored the immunoreactivity of LAMP2, which was localized in neurons in the superficial layers of the spinal dorsal horn in spinal nerve-injured rats. In addition, intraperitoneal administration of 15 mg/kg chloroquine for 60 minutes reversed the expression of the aforementioned proteins and shortened the timing of the analgesic effects of HF-SCS. These findings suggest that HF-SCS may exhibit longlasting analgesic effects on neuropathic pain in rats through improving lysosomal dysfunction and alleviating autophagic flux. This study was approved by the Laboratory Animal Ethics Committee of China Medical University, Shenyang, China(approval No. 2017 PS196 K) on March 1, 2017.
文摘An accurate detection of the effective values of electric voltage and current from high frequency power generators is a precondition for the development of smart electrotomes. In this light, an energy detection system based on personal computer (PC) is developed hereby. It senses voltage and current in isolation from generators with transformers, and then the measured values are amplified, filtered, transformed into single-ended signals and converted to RMS. The detected signals are transformed into digital signals through Data Acquisition Card (DAQ) and the data are processed with quadratic fit in Labview. Finally, the controller completes constant power output. The experiment results indicate that the energy detection system can measure the output parameters precisely and the controller can achieve constant power control.
文摘Epilepsy is one of the most common serious neurological disorders. Pharmacoresistant epilepsy patients are poorly controlled or their seizures are refractory to drug treatment. Resective surgery is frequently a promising therapy in this population, however, not all the patients meet the eligibility criteria for the surgical treatment. Deep brain stimulation has been investigated in clinical studies and animal studies as an alternative treatment, but the optimal stimulation parameters remain an issue. The present study was designed to investigate the effect of unilateral high-frequency stimulation (HFS) of hippocampus on seizure development by using the hippocampal rapid kindling method (hRK) in rats, and compared the results with those of low-frequency stimulation previously published by our group. We used male Wistar rats implanted with electrodes in the ventral hippocampus. All rats underwent hRK (biphasic square wave pulses, 20 Hz for 10 seconds) during three consecutive days (twelve stimulations per day). The control group (hRK;n = 7) received only RK stimulus, while the treated group (HFS-hRK;n = 9) received also HFS (biphasic square wave pulses, 130 Hz for 30 seconds) immediately before the RK stimulus, during three consecutive days. At the end of behavioral testing 78% (p 0.01) of the animals receiving HFS treatment were still not fully kindled staying in stages 0 -III (p 0.01). HFS group needed a higher number of stimulations to achieve stage III (p 0.05) with respect to control group. However, no significant differences in the cumulative daily afterdischarge duration were observed. HFS did not present significant differences compared with LFS in any of studied parameters. The findings suggest that unilateral HFS applied on hippocampus effectively inhibited the epileptogenic process induced by hippocampal rapid kindling. According to the comparative results about hippocampal rapid kindled animals stimulated with HFS and LFS (5 Hz), we found no conclusive information on which treatment is most efficient.
基金supported by the science and technology project of State Grid Corporation of China(Project Code:1400-202157207A-0-0-00)the National Natural Science Foundation of China[grant numbers 72273137].
文摘The total electricity consumption(TEC)can accurately reflect the operation of the national economy,and the forecasting of the TEC can help predict the economic development trend,as well as provide insights for the formulation of macro policies.Nowadays,high-frequency and massive multi-source data provide a new way to predict the TEC.In this paper,a"seasonal-cumulative temperature index"is constructed based on high-frequency temperature data,and a mixed-frequency prediction model based on multi-source big data(Mixed Data Sampling with Monthly Temperature and Daily Temperature index,MIDAS-MT-DT)is proposed.Experimental results show that the MIDAS-MT-DT model achieves higher prediction accuracy,and the"seasonal-cumulative temperature index"can improve prediction accuracy.