The introduction of functionalized magnetizable particles and high-gradient magnetic separation represents a time and money saving alternative to conventional purification and separation unit operations in the biotech...The introduction of functionalized magnetizable particles and high-gradient magnetic separation represents a time and money saving alternative to conventional purification and separation unit operations in the biotechnical sector. This technique has some advantages especially for the recycling of immobilized enzymes. A new magnetic filter with sight glasses was constructed and produced to study the performance of high-gradient magnetic separation at varied parameters. By optical analysis the buildup of a clogging was identified as the major parameter which affected the separation performance. For the cleaning procedure, a two-phase flow of water with highly dispersed air bubbles was tested which led to a nearly complete cleaning of the filter chamber.展开更多
The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological pro...The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological process design. The selective separation of the magnetizable particles is performed for example by a high-gradient magnetic separator. In this study FEM and CFD simulations of the magnetic field and the fluid flow field within a filter chamber of a magnetic separator were carried out, to find an optimal separator design. The motion of virtual magnetizable particles was calculated with a one-way coupled Lagrangian approach in order to test many geometric and parametric variations in reduced time. It was found that a flow homogenisator smoothed the fluid flow, so that the linear velocity became nearly equal over the cross section in the direction of flow. Furthermore the retention of magnetizable particles increases with a high total edge length within the filter matrix.展开更多
A new permanent magnetic separator was introduced to treat the ores with the characteristics of weak magnetic iron minerals and in a fine size range. The new machine was applied to the iron removal from potash feldspa...A new permanent magnetic separator was introduced to treat the ores with the characteristics of weak magnetic iron minerals and in a fine size range. The new machine was applied to the iron removal from potash feldspar. The effects of the magnetic field intensity, pulp density and grinding fineness on the iron removal were investigated. The optimized operation parameters were achieved and listed as follows: the -0.074 mm content is 85%, the pulp density is 45% and the magnetic field strength is 2T. A close test of middles regrinding was also carried out to improve concentrate yield. The data show that the grade of TFe(total iron) in potash feldspar product decreased from 1.31% to 0.21% and the concentrate yield reached 85.32%. All the results indicated that the traditonal high-intensity electromagnetic separators can be betterly substituted by the new permanent magnetic separator. This study may provide the theoretical evidence for iron removal from potash feldspar.展开更多
A wire rope defects detection method based on permanent magnet excitation is proposed.A detection system,mainly composed of permanent magnet excitation,distance detection,multi-sensor magnetic flux leakage signal acqu...A wire rope defects detection method based on permanent magnet excitation is proposed.A detection system,mainly composed of permanent magnet excitation,distance detection,multi-sensor magnetic flux leakage signal acquisition and data analysis device,is set up.According to the different characteristics of the multi-sensor magnetic flux leakage signal,the localized fault(LF)and loss of metallic cross-sectional area(LMA)signal is separated,and then the two defects can be detected.The experiments show that the method can effectively detect the two defects when they appear simultaneously on the wire rope.展开更多
文摘The introduction of functionalized magnetizable particles and high-gradient magnetic separation represents a time and money saving alternative to conventional purification and separation unit operations in the biotechnical sector. This technique has some advantages especially for the recycling of immobilized enzymes. A new magnetic filter with sight glasses was constructed and produced to study the performance of high-gradient magnetic separation at varied parameters. By optical analysis the buildup of a clogging was identified as the major parameter which affected the separation performance. For the cleaning procedure, a two-phase flow of water with highly dispersed air bubbles was tested which led to a nearly complete cleaning of the filter chamber.
文摘The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological process design. The selective separation of the magnetizable particles is performed for example by a high-gradient magnetic separator. In this study FEM and CFD simulations of the magnetic field and the fluid flow field within a filter chamber of a magnetic separator were carried out, to find an optimal separator design. The motion of virtual magnetizable particles was calculated with a one-way coupled Lagrangian approach in order to test many geometric and parametric variations in reduced time. It was found that a flow homogenisator smoothed the fluid flow, so that the linear velocity became nearly equal over the cross section in the direction of flow. Furthermore the retention of magnetizable particles increases with a high total edge length within the filter matrix.
基金Funded by the National High-tech R&D Program of China(No.2007AA06Z123)the Hubei Provincial Key Laboratory of Pollutant Analysis and Recycling Project(KY2010G19)the Independent Innovation Research Fund of Wuhan University of Technology(2010-YB-16)
文摘A new permanent magnetic separator was introduced to treat the ores with the characteristics of weak magnetic iron minerals and in a fine size range. The new machine was applied to the iron removal from potash feldspar. The effects of the magnetic field intensity, pulp density and grinding fineness on the iron removal were investigated. The optimized operation parameters were achieved and listed as follows: the -0.074 mm content is 85%, the pulp density is 45% and the magnetic field strength is 2T. A close test of middles regrinding was also carried out to improve concentrate yield. The data show that the grade of TFe(total iron) in potash feldspar product decreased from 1.31% to 0.21% and the concentrate yield reached 85.32%. All the results indicated that the traditonal high-intensity electromagnetic separators can be betterly substituted by the new permanent magnetic separator. This study may provide the theoretical evidence for iron removal from potash feldspar.
文摘A wire rope defects detection method based on permanent magnet excitation is proposed.A detection system,mainly composed of permanent magnet excitation,distance detection,multi-sensor magnetic flux leakage signal acquisition and data analysis device,is set up.According to the different characteristics of the multi-sensor magnetic flux leakage signal,the localized fault(LF)and loss of metallic cross-sectional area(LMA)signal is separated,and then the two defects can be detected.The experiments show that the method can effectively detect the two defects when they appear simultaneously on the wire rope.