In this paper, we conduct research on the novel pattern of soft music creation based on high-pitched melody element and aesthetic point of view. Music is the music creation, music is a kind of creation and it is not a...In this paper, we conduct research on the novel pattern of soft music creation based on high-pitched melody element and aesthetic point of view. Music is the music creation, music is a kind of creation and it is not a simple thing, because music is an expression of human thoughts and feelings which reflect the social life of an art. Music creation and other artistic creation need perceptual and rational psychological elements such as the creation principle of participation. This involves the music creation that the relationship between the perceptual thinking and rational thinking. Our research proposed the novel paradigm of art creation which will obtain significant meaning.展开更多
Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-...Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans.展开更多
文摘In this paper, we conduct research on the novel pattern of soft music creation based on high-pitched melody element and aesthetic point of view. Music is the music creation, music is a kind of creation and it is not a simple thing, because music is an expression of human thoughts and feelings which reflect the social life of an art. Music creation and other artistic creation need perceptual and rational psychological elements such as the creation principle of participation. This involves the music creation that the relationship between the perceptual thinking and rational thinking. Our research proposed the novel paradigm of art creation which will obtain significant meaning.
文摘Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans.