期刊文献+
共找到159,760篇文章
< 1 2 250 >
每页显示 20 50 100
In vivo pilot study into superficial microcirculatory characteristics of colorectal adenomas using novel high-resolution magnifying endoscopy with blue laser imaging
1
作者 Hai-Bin Dong Tao Chen +2 位作者 Xiao-Fei Zhang Yu-Tang Ren Bo Jiang 《World Journal of Gastrointestinal Endoscopy》 2024年第4期206-213,共8页
BACKGROUND No studies have yet been conducted on changes in microcirculatory hemody-namics of colorectal adenomas in vivo under endoscopy.The microcirculation of the colorectal adenoma could be observed in vivo by a n... BACKGROUND No studies have yet been conducted on changes in microcirculatory hemody-namics of colorectal adenomas in vivo under endoscopy.The microcirculation of the colorectal adenoma could be observed in vivo by a novel high-resolution magnification endoscopy with blue laser imaging(BLI),thus providing a new insight into the microcirculation of early colon tumors.AIM To observe the superficial microcirculation of colorectal adenomas using the novel magnifying colonoscope with BLI and quantitatively analyzed the changes in hemodynamic parameters.METHODS From October 2019 to January 2020,11 patients were screened for colon adenomas with the novel high-resolution magnification endoscope with BLI.Video images were recorded and processed with Adobe Premiere,Adobe Photoshop and Image-pro Plus software.Four microcirculation parameters:Microcirculation vessel density(MVD),mean vessel width(MVW)with width standard deviation(WSD),and blood flow velocity(BFV),were calculated for adenomas and the surrounding normal mucosa.RESULTS A total of 16 adenomas were identified.Compared with the normal surrounding mucosa,the superficial vessel density in the adenomas was decreased(MVD:0.95±0.18 vs 1.17±0.28μm/μm2,P<0.05).MVW(5.11±1.19 vs 4.16±0.76μm,P<0.05)and WSD(11.94±3.44 vs 9.04±3.74,P<0.05)were both increased.BFV slowed in the adenomas(709.74±213.28 vs 1256.51±383.31μm/s,P<0.05).CONCLUSION The novel high-resolution magnification endoscope with BLI can be used for in vivo study of adenoma superficial microcirculation.Superficial vessel density was decreased,more irregular,with slower blood flow. 展开更多
关键词 ADENOMA MICROCIRCULATION high-resolution magnification endoscopy Blue laser imaging
下载PDF
Verification and Validation of High-Resolution Inviscid and Viscous Conical Nozzle Flows
2
作者 Luciano K.Araki Rafael B.de R.Borges +1 位作者 Nicholas Dicati P.da Silva Chi-Wang Shu 《Communications on Applied Mathematics and Computation》 EI 2024年第1期533-549,共17页
Capturing elaborated flow structures and phenomena is required for well-solved numerical flows.The finite difference methods allow simple discretization of mesh and model equations.However,they need simpler meshes,e.g... Capturing elaborated flow structures and phenomena is required for well-solved numerical flows.The finite difference methods allow simple discretization of mesh and model equations.However,they need simpler meshes,e.g.,rectangular.The inverse Lax-Wendroff(ILW)procedure can handle complex geometries for rectangular meshes.High-resolution and high-order methods can capture elaborated flow structures and phenomena.They also have strong mathematical and physical backgrounds,such as positivity-preserving,jump conditions,and wave propagation concepts.We perceive an effort toward direct numerical simulation,for instance,regarding weighted essentially non-oscillatory(WENO)schemes.Thus,we propose to solve a challenging engineering application without turbulence models.We aim to verify and validate recent high-resolution and high-order methods.To check the solver accuracy,we solved vortex and Couette flows.Then,we solved inviscid and viscous nozzle flows for a conical profile.We employed the finite difference method,positivity-preserving Lax-Friedrichs splitting,high-resolution viscous terms discretization,fifth-order multi-resolution WENO,ILW,and third-order strong stability preserving Runge-Kutta.We showed the solver is high-order and captured elaborated flow structures and phenomena.One can see oblique shocks in both nozzle flows.In the viscous flow,we also captured a free-shock separation,recirculation,entrainment region,Mach disk,and the diamond-shaped pattern of nozzle flows. 展开更多
关键词 high-resolution COMPRESSIBLE NAVIER-STOKES Free-shock separation Nozzle flow
下载PDF
Accurate Source-Receiver Positioning Method for a High-Resolution Deep-Towed Multichannel Seismic Exploration System
3
作者 LI Jing LIU Kai +5 位作者 WEI Zhengrong ZHANG Liancheng LIU Yangting PEI Yanliang LIU Chenguang LIU Baohua 《Journal of Ocean University of China》 CAS CSCD 2024年第2期415-426,共12页
The near-seabed multichannel seismic exploration systems have yielded remarkable successes in marine geological disaster assessment,marine gas hydrate investigation,and deep-sea mineral exploration owing to their high... The near-seabed multichannel seismic exploration systems have yielded remarkable successes in marine geological disaster assessment,marine gas hydrate investigation,and deep-sea mineral exploration owing to their high vertical and horizontal resolution.However,the quality of deep-towed seismic imaging hinges on accurate source-receiver positioning information.In light of existing technical problems,we propose a novel array geometry inversion method tailored for high-resolution deep-towed multichannel seismic exploration systems.This method is independent of the attitude and depth sensors along a deep-towed seismic streamer,accounting for variations in seawater velocity and seabed slope angle.Our approach decomposes the towed line array into multiline segments and characterizes its geometric shape using the line segment distance and pitch angle.Introducing optimization parameters for seawater velocity and seabed slope angle,we establish an objective function based on the model,yielding results that align with objective reality.Employing the particle swarm optimization algorithm enables synchronous acquisition of optimized inversion results for array geometry and seawater velocity.Experimental validation using theoretical models and practical data verifies that our approach effectively enhances source and receiver positioning inversion accuracy.The algorithm exhibits robust stability and reliability,addressing uncertainties in seismic traveltime picking and complex seabed topography conditions. 展开更多
关键词 high-resolution deep-towed multichannel seismic exploration source-receiver positioning array geometry inversion seawater heterogeneity seabed slope angle
下载PDF
Investigating the relationship between intracranial atherosclerotic plaque remodelling and diabetes using high-resolution vessel wall imaging
4
作者 Yong-Qian Mo Hai-Yu Luo +5 位作者 Han-Wen Zhang Yu-Feng Liu Kan Deng Xiao-Lei Liu Biao Huang Fan Lin 《World Journal of Diabetes》 SCIE 2024年第1期72-80,共9页
BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imag... BACKGROUND Intracranial atherosclerosis,a leading cause of stroke,involves arterial plaque formation.This study explores the link between plaque remodelling patterns and diabetes using high-resolution vessel wall imaging(HR-VWI).AIM To investigate the factors of intracranial atherosclerotic remodelling patterns and the relationship between intracranial atherosclerotic remodelling and diabetes mellitus using HR-VWI.METHODS Ninety-four patients diagnosed with middle cerebral artery or basilar artery INTRODUCTION Intracranial atherosclerotic disease is one of the main causes of ischaemic stroke in the world,accounting for approx-imately 10%of transient ischaemic attacks and 30%-50%of ischaemic strokes[1].It is the most common factor among Asian people[2].The adaptive changes in the structure and function of blood vessels that can adapt to changes in the internal and external environment are called vascular remodelling,which is a common and important pathological mechanism in atherosclerotic diseases,and the remodelling mode of atherosclerotic plaques is closely related to the occurrence of stroke.Positive remodelling(PR)is an outwards compensatory remodelling where the arterial wall grows outwards in an attempt to maintain a constant lumen diameter.For a long time,it was believed that the degree of stenosis can accurately reflect the risk of ischaemic stroke[3-5].Previous studies have revealed that lesions without significant luminal stenosis can also lead to acute events[6,7],as summarized in a recent meta-analysis study in which approximately 50%of acute/subacute ischaemic events were due to this type of lesion[6].Research[8,9]has pointed out that the PR of plaques is more dangerous and more likely to cause acute ischaemic stroke.Previous studies[10-13]have found that there are specific vascular remodelling phenomena in the coronary and carotid arteries of diabetic patients.However,due to the deep location and small lumen of intracranial arteries and limitations of imaging techniques,the relationship between intracranial arterial remodelling and diabetes is still unclear.In recent years,with the development of magnetic resonance technology and the emergence of high-resolution(HR)vascular wall imaging,a clear and multidimensional display of the intracranial vascular wall has been achieved.Therefore,in this study,HR wall imaging(HR-VWI)was used to display the remodelling characteristics of bilateral middle cerebral arteries and basilar arteries and to explore the factors of intracranial vascular remodelling and its relationship with diabetes. 展开更多
关键词 high-resolution vessel wall imaging Intracranial atherosclerosis Vascular remodelling Magnetic resonance imaging
下载PDF
Few-Shot Object Detection Based on the Transformer and High-Resolution Network 被引量:1
5
作者 Dengyong Zhang Huaijian Pu +2 位作者 Feng Li Xiangling Ding Victor S.Sheng 《Computers, Materials & Continua》 SCIE EI 2023年第2期3439-3454,共16页
Now object detection based on deep learning tries different strategies.It uses fewer data training networks to achieve the effect of large dataset training.However,the existing methods usually do not achieve the balan... Now object detection based on deep learning tries different strategies.It uses fewer data training networks to achieve the effect of large dataset training.However,the existing methods usually do not achieve the balance between network parameters and training data.It makes the information provided by a small amount of picture data insufficient to optimize model parameters,resulting in unsatisfactory detection results.To improve the accuracy of few shot object detection,this paper proposes a network based on the transformer and high-resolution feature extraction(THR).High-resolution feature extractionmaintains the resolution representation of the image.Channels and spatial attention are used to make the network focus on features that are more useful to the object.In addition,the recently popular transformer is used to fuse the features of the existing object.This compensates for the previous network failure by making full use of existing object features.Experiments on the Pascal VOC and MS-COCO datasets prove that the THR network has achieved better results than previous mainstream few shot object detection. 展开更多
关键词 Object detection few shot object detection TRANSFORMER high-resolution
下载PDF
High-Resolution Mass Spectroscopy for Revealing the Charge Storage Mechanism in Batteries: Oxamide Materials as an Example
6
作者 Chenyang Zhang Yuan Chen +7 位作者 Kun Fan Guoqun Zhang Jincheng Zou Huichao Dai Yanbo Gao Xiaobo Wang Minglei Mao Chengliang Wang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2023年第4期195-202,共8页
The pursuit of high-performance electrode materials is highly desired to meet the demand of batteries with high energy and power density.However,a deep understanding of the charge storage mechanism is always challengi... The pursuit of high-performance electrode materials is highly desired to meet the demand of batteries with high energy and power density.However,a deep understanding of the charge storage mechanism is always challenging,which limits the development of advanced electrode materials.Herein,high-resolution mass spectroscopy(HR-MS)is employed to detect the evolution of organic electrode materials during the redox process and reveal the charge storage mechanism,by using small molecular oxamides as an example,which have ortho-carbonyls and are therefore potential electrochemical active materials for batteries.The HR-MS results adequately proved that the oxamides could reversibly store lithium ions in the voltage window of 1.5–3.8 V.Upon deeper reduction,the oxamides would decompose due to the cleavage of the C–N bonds in oxamide structures,which could be proved by the fragments detected by HR-MS,^(1)H NMR,and the generation of NH_(3)after the reduction of oxamide by Li.This work provides a strategy to deeply understand the charge storage mechanism of organic electrode materials and will stimulate the further development of characterization techniques to reveal the charge storage mechanism for developing high-performance electrode materials. 展开更多
关键词 charge storage mechanism high-resolution mass spectroscopy organic batteries organic electrodes oxamides
下载PDF
A systematic printability study of direct ink writing towards high-resolution rapid manufacturing
7
作者 Qingyang Zheng Bin Xie +1 位作者 Zhoulong Xu Hao Wu 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2023年第3期500-517,共18页
Direct ink writing(DIW)holds enormous potential in fabricating multiscale and multi-functional architectures by virtue of its wide range of printable materials,simple operation,and ease of rapid prototyping.Although i... Direct ink writing(DIW)holds enormous potential in fabricating multiscale and multi-functional architectures by virtue of its wide range of printable materials,simple operation,and ease of rapid prototyping.Although it is well known that ink rheology and processing parameters have a direct impact on the resolution and shape of the printed objects,the underlying mechanisms of these key factors on the printability and quality of DIW technique remain poorly understood.To tackle this issue,we systematically analyzed the printability and quality through extrusion mechanism modeling and experimental validating.Hybrid non-Newtonian fluid inks were first prepared,and their rheological properties were measured.Then,finite element analysis of the whole DIW process was conducted to reveal the flow dynamics of these inks.The obtained optimal process parameters(ink rheology,applied pressure,printing speed,etc)were also validated by experiments where high-resolution(<100μm)patterns were fabricated rapidly(>70 mm s^(-1)).Finally,as a process research demonstration,we printed a series of microstructures and circuit systems with hybrid inks and silver inks,showing the suitability of the printable process parameters.This study provides a strong quantitative illustration of the use of DIW for the high-speed preparation of high-resolution,high-precision samples. 展开更多
关键词 direct ink writing extrusion mechanism modelling computational fluid dynamic(CFD) printability process parameters high-resolution printing
下载PDF
新型^(18)F-FES PET/CT无创功能性诊断乳腺癌迟发性肺转移致霍纳综合征一例 被引量:1
8
作者 姚儒 郝志鑫 +7 位作者 屈洋 张超 李唯佳 郎洁 潘博 周易冬 孙强 霍力 《协和医学杂志》 CSCD 北大核心 2024年第3期702-707,共6页
激素受体阳性、人表皮生长因子受体2型阴性(HR^(+)/HER2^(-))乳腺癌是最常见的乳腺癌分子亚型,可表现为术后10~15年以上的迟发性复发,且其肺转移病灶需与原发性肺癌相鉴别。本文报道1例HR^(+)/HER2^(-)乳腺癌术后16年迟发性肺转移致霍... 激素受体阳性、人表皮生长因子受体2型阴性(HR^(+)/HER2^(-))乳腺癌是最常见的乳腺癌分子亚型,可表现为术后10~15年以上的迟发性复发,且其肺转移病灶需与原发性肺癌相鉴别。本文报道1例HR^(+)/HER2^(-)乳腺癌术后16年迟发性肺转移致霍纳综合征患者,采用^(18)F-FDG PET/CT难以判断肿瘤来源,穿刺活检风险高,经北京协和医院新型^(18)F-FES PET/CT无创功能性诊断为乳腺癌肺上叶雌激素受体(estrogen receptor,ER)阳性转移,给予CDK4/6抑制剂+芳香化酶抑制剂内分泌解救治疗后获得缓解。本文总结该患者的临床表现及诊治经过,为新型^(18)F-FES PET/CT评估乳腺癌患者转移灶的ER表达情况及指导后续个体化诊疗提供借鉴。 展开更多
关键词 乳腺癌 ^(18)F-FES PET/ct 肺转移 霍纳综合征 雌激素受体
下载PDF
CT血管成像对ACI患者颈动脉狭窄程度及侧支循环的价值研究 被引量:2
9
作者 李飞 马新强 +3 位作者 耿云平 姜涛 米玉霞 张冉 《罕少疾病杂志》 2024年第1期32-34,共3页
目的分析、探究CT血管成像技术在ACI患者颈动脉狭窄、侧支循环等病情诊断方面的成效。方法对我院2021.3-2022.3月期间收治的100例急性脑梗死(ACI)患者一般病理资料进行回顾性分析,以数字减影血管造影(DSA)结果为诊断金标准,对CT血管成... 目的分析、探究CT血管成像技术在ACI患者颈动脉狭窄、侧支循环等病情诊断方面的成效。方法对我院2021.3-2022.3月期间收治的100例急性脑梗死(ACI)患者一般病理资料进行回顾性分析,以数字减影血管造影(DSA)结果为诊断金标准,对CT血管成像技术(CTA)的诊断价值进行分析,以临床出具的数字减影血管造影(DSA)结果为金标准,分析CT血管成像技术(CTA)在临床上的诊断价值,评估此技术在临床诊断中的效能。结果与临床金标准相比,CTA诊断技术具有较高的临床评估价值[Kappa>0.8~1.0,曲线下面积(AUC)>0.9,P<0.01];CTA诊断技术在评估颈动脉狭窄程度等方面与临床金标准具有一定的一致性[Kappa>0.6~0.8,曲线下面积(AUC)>0.7~0.9,P<0.01];而在评估侧支循环临床诊断中,CTA诊断技术与临床金标准具有一致性,具有较高的评估价值[Kappa>0.8~1.0,曲线下面积(AUC)>0.9,P<0.01]。结论以临床“金标准”的诊断结果为依据分析,CTA诊断技术能够对ACI患者出现病变的血管形态及侧支循环状态等进行全面的评估,CTA诊断结果可为治疗工作提供准确性相对较高且客观的医学依据,确实是评估ACI患者颈动脉狭窄程度、侧支循环状态的可靠办法;而与DSA技术相比,CTA与之具有较高的一致性,说明在病情发作早期为ACI患者实施CTA检查可获悉颈动脉的狭窄及侧支循环状态,有利于改善患者群体的预后。 展开更多
关键词 ct血管成像 ACI患者 颈动脉 狭窄程度 侧支循环 研究情况
下载PDF
Clinical study on high-resolution CT and pulmonary function in severe acute respiratory syndrome patients during recovery phase 被引量:2
10
作者 YINCheng-hong WANGChao +10 位作者 WENYan JIANGLi LIUYing JIAOYun-min CHENJiang-hong TANGShu-zhen YUEMao-xing HEZheng-yi MADa-qing ZHANGShu-wen WANGBao-en 《Chinese Medical Journal》 SCIE CAS CSCD 2005年第6期512-515,共4页
Severe acute respiratory syndrome (SARS) is an acute respiratory infectious disease caused by a novel coronavirus, firstly broke out in November 2002 in Guangdong and prevailed quickly in Beijing, Hong Kong, Taiwan an... Severe acute respiratory syndrome (SARS) is an acute respiratory infectious disease caused by a novel coronavirus, firstly broke out in November 2002 in Guangdong and prevailed quickly in Beijing, Hong Kong, Taiwan and other regions of China. It was one of the most potential pandemic diseases and had affected more than 20 other countries.^(1,2) There have been a lot of resear-ches^(2-7) in terms of its etiology, epidemiology, pathogenesis, clinical characteristics, diagnostics, treatment and prevention, vaccines and so on.Along with control of the epidemic situation, a great number of SARS patients were in the recovery phase, therefore, we undertook a half-year follow-up investigation on their clinical, laboratory and image situations. 展开更多
关键词 severe acute respiratory syndrome · recovery phase · high-resolution ct · pulmonary function
原文传递
术中滑轨CT辅助在经皮骶髂关节螺钉治疗骨盆后环损伤中的应用 被引量:1
11
作者 盛斌 王奕威 +4 位作者 王愉思 刘德龙 杨瞻宇 关蕊 刘超 《中国骨伤》 CAS CSCD 2024年第5期438-444,共7页
目的:比较术中滑轨CT联合C形臂X线机辅助与单纯使用C形臂X线机辅助透视下经皮骶髂关节螺钉治疗骨盆后环损伤临床疗效。方法:自2018年12月至2022年2月收治76例骨盆后环损伤患者,其中,C形臂联合滑轨CT辅助下行内固定治疗39例为CT组,男23例... 目的:比较术中滑轨CT联合C形臂X线机辅助与单纯使用C形臂X线机辅助透视下经皮骶髂关节螺钉治疗骨盆后环损伤临床疗效。方法:自2018年12月至2022年2月收治76例骨盆后环损伤患者,其中,C形臂联合滑轨CT辅助下行内固定治疗39例为CT组,男23例,女16例,年龄(44.98±7.33)岁;仅在C形臂透视下行内固定治疗37例为C形臂组,男24例,女13例,年龄(44.37±10.82)岁。合并有前环骨折患者42例,均采用经皮髂前下棘内置外固定架(internal fixation,INFIX)或耻骨上支螺钉固定骨盆前环。术后比较两组随访时间、置钉时间、并发症。比较两组Matta复位评价、Majeed疗效评价、CT分级及二次手术翻修率。结果:CT组置钉时间(32.63±7.33) min,短于C形臂组(52.95±10.64) min(t=-9.739,P<0.05)。CT组随访时间(11.97±1.86)个月,C形臂组(12.03±1.71)个月,两组比较差异无统计学意义(P>0.05)。两组术后并发症发生比较,差异无统计学意义(χ~2=0.159,P>0.05)。CT组Matta复位评价结果(Z=2.79,P<0.05)、Majeed疗效评价结果(Z=2.79,P<0.05)、CT分级(Z=2.83,P<0.05)均优于C形臂组。CT组二次手术翻修率低于C形臂组(χ~2=5.641,P<0.05)。结论:术中滑轨CT联合C形臂辅助下经皮骶髂关节螺钉置入手术与传统C形臂透视相比,具有手术时间短、准确度及安全性高、术后二次翻修率显著下降等特点,是重建骨盆骨折后环稳定性的有效方法之一。 展开更多
关键词 滑轨ct 经皮骶髂关节螺钉 骨盆后环损伤 术中透视 微创
下载PDF
胸腹部平扫CT值用于机会性筛查骨质疏松的可行性
12
作者 王旭 刘磊 +3 位作者 刘义军 童小雨 范勇 王诗耕 《放射学实践》 CSCD 北大核心 2024年第3期393-398,共6页
目的:基于定量CT(QCT)探讨胸部常规kVp平扫和腹部能谱GSI平扫下椎体CT值用于机会性筛查骨质疏松的可行性。方法:前瞻性收集接受胸腹部平扫的患者431例,胸部CT扫描采用常规120 kVp,腹部扫描采用能谱(GSI)模式。对胸腹部扫描重叠的T11~L1... 目的:基于定量CT(QCT)探讨胸部常规kVp平扫和腹部能谱GSI平扫下椎体CT值用于机会性筛查骨质疏松的可行性。方法:前瞻性收集接受胸腹部平扫的患者431例,胸部CT扫描采用常规120 kVp,腹部扫描采用能谱(GSI)模式。对胸腹部扫描重叠的T11~L1椎体进行分析。使用QCT骨密度测量工作站测得胸部常规120 kVp下T11~L1椎体的骨密度(BMD),同时分别测量胸部120 kVp与腹部GSI扫描70 keV单能量下T11~L1椎体的CT值。采用组内相关系数(ICC)评估数据测量的一致性,Spearman相关性检验分析椎体BMD值与CT值之间的相关性。不同椎体间CT值差异采用Friedman秩和检验。参考QCT诊断标准,将椎体分为骨质疏松、骨量减少和骨量正常组,采用Kruskal-Wallis比较三组间及组内CT值差异。组内120 kVp-CT值和GSI-CT值采用Wilcoxon秩和检验。以T11~L1椎体BMD均值行骨质状态判定,采用受试者操作特征(ROC)曲线分析椎体CT值评估骨质状态的诊断效能。结果:椎体BMD与120 kVp-CT值和GSI-CT值均呈正相关(r=0.976、0.963,P<0.001)。120 kVp和GSI下T11~L1椎体CT值依次为T11[144.00(72.00)、158.00(79.00)]、T12[137.00(67.00)、150.00(76.00)]、L1[128.00(67.00)、137.00(74.00)],不同椎体及椎体内差异均有统计学意义(P<0.001)。431例患者共1293个椎体,骨量正常组椎体496个、骨量减少组椎体415个、骨质疏松组椎体382个。120 kVp和GSI下骨量正常、骨量减少和骨质疏松组椎体CT值依次为[181.50(43.67)、199.65(48.57)]、[132.20(18.50)、144.00(23.00)]和[87.75(22.20)、93.30(27.20)],不同骨质状态组间椎体CT值差异有统计学意义(P<0.05),且各组组内椎体GSI-CT值均高于椎体120 kVp-CT值(P<0.05)。120 kVp-CT值与GSI-CT值诊断骨量减少的AUC分别为0.976、0.967,差异无统计学意义(P=0.0937);诊断骨质疏松的AUC均为1.000,差异无统计学意义(P=1.000)。结论:胸部常规120 kVp及腹部GSI平扫CT值均可用于机会性筛查骨质疏松,诊断效能良好。 展开更多
关键词 骨质疏松 骨密度 定量ct 能谱ct ct
下载PDF
颅脑CT灌注成像及磁共振成像在脑梗死患者中的应用 被引量:3
13
作者 荆梅 顾欣欣 《中国实用神经疾病杂志》 2024年第1期43-47,共5页
目的分析颅脑CT灌注成像及磁共振成像对脑梗死患者的诊断价值。方法选取2022-03—2023-05在江苏省中西医结合医院就诊的80例疑似脑梗死患者为研究对象,对比分析GE Revolution CT颅脑灌注成像、磁共振成像及联合检查的敏感性、特异性、... 目的分析颅脑CT灌注成像及磁共振成像对脑梗死患者的诊断价值。方法选取2022-03—2023-05在江苏省中西医结合医院就诊的80例疑似脑梗死患者为研究对象,对比分析GE Revolution CT颅脑灌注成像、磁共振成像及联合检查的敏感性、特异性、准确性,制作3种影像学检查的受试者工作特征(ROC)曲线。结果根据患者病情和临床综合诊断确诊,80例疑似脑梗死患者中脑梗死阳性69例(86.25%),脑梗死阴性11例(13.75%)。3种影像学检查方法的灵敏度、准确率比较,从高到低依次为联合检查、GE Revolution CT颅脑灌注成像检查、磁共振成像检查,差异有统计学意义(P<0.05)。GE Revolution CT颅脑灌注成像检查、磁共振成像检查、联合检查诊断脑梗死的ROC曲线下面积(AUC)分别为0.8109、0.7688、0.8682。结论GE Revolution CT颅脑灌注成像与磁共振成像检查的联合应用,有利于提高脑梗死患者诊断的灵敏度、准确率及AUC水平。 展开更多
关键词 脑梗死 GE Revolution ct 颅脑灌注成像 磁共振成像 灵敏度 准确率
下载PDF
优化双下肢动脉能谱CT血管造影成像方案
14
作者 胡莹莹 张珂 +3 位作者 何辰宇 孙宏亮 王蕾 谢晟 《中国介入影像与治疗学》 北大核心 2024年第4期242-246,共5页
目的优化双下肢动脉能谱CT血管造影(CTA)成像方案。方法回顾性分析30例疑诊双下肢动脉硬化性闭塞症(ASO)患者双下肢动脉能谱CTA资料,经重建获得40~80 keV(间隔5 keV)单能量(共9种)及100 kVp混合能量图像,对比双下肢动脉在不同图像中的C... 目的优化双下肢动脉能谱CT血管造影(CTA)成像方案。方法回顾性分析30例疑诊双下肢动脉硬化性闭塞症(ASO)患者双下肢动脉能谱CTA资料,经重建获得40~80 keV(间隔5 keV)单能量(共9种)及100 kVp混合能量图像,对比双下肢动脉在不同图像中的CT值、噪声(SD)值、信噪比(SNR)及对比度噪声比(CNR);针对50、60 keV单能量和100 kVp混合能量图像质量及血管节段的可诊断性进行主观评估,观察40、45、50、60 keV单能量和100 kVp混合能量图像的自动去骨能力。结果40~80 keV范围内,随keV升高,各动脉在图像中的CT值、SD值、SNR及CNR均逐渐降低。相比100 kVp,腘动脉(PA)及其近端动脉的CT值、CNR及SNR均在40~55 keV图像中升高(P均<0.05);50~55 keV图像中SD值升高(P均<0.05),而60 keV图像中差异无统计学意义(P>0.05)。50及60 keV图像质量主观评分及可诊断动脉节段数与100 kVp差异均无统计学意义(P均>0.05)。PA以远节段的SNR及CNR在各单能量图像及100 kVp图像中差异均无统计学意义,其CT值在40~45 keV图像中、SD在40 keV图像中均高于100 kVp(P均<0.05),但SD在45 keV与100 kVp图像中差异无统计学意义(P>0.05);50 keV图像中,PA以远节段图像质量主观评分及可诊断节段数均高于60 keV及100 kVp(P均<0.05)。40 keV图像对9例(9/30,30.00%)、45 keV图像对6例(6/30,20.00%)不能自动去骨,50及60 keV、100 kVp对30例(30/30,100%)均可自动去骨。结论行双下肢动脉能谱CTA时,对PA及其近端节段以60 keV单能量成像较佳,对其以远或双下肢全程则以50 keV单能量成像较佳。 展开更多
关键词 下肢 动脉 ct血管成像 能谱ct
下载PDF
经头颈部CTA联合三维重建技术用于脑血管疾病动脉狭窄的诊断价值 被引量:1
15
作者 杨浩 武乐乐 +1 位作者 曹阿丹 胡舸帆 《罕少疾病杂志》 2024年第5期12-14,共3页
目的分析经头颈部CT血管造影(CTA)联合三维重建技术对脑血管疾病的特点及对脑血管疾病动脉狭窄的诊断作用。方法选择我院在2021年8月至2022年8月期间收治的脑血管疾病动脉狭窄患者118例进行观察,所有患者均进行经头颈部CTA检查,将获取... 目的分析经头颈部CT血管造影(CTA)联合三维重建技术对脑血管疾病的特点及对脑血管疾病动脉狭窄的诊断作用。方法选择我院在2021年8月至2022年8月期间收治的脑血管疾病动脉狭窄患者118例进行观察,所有患者均进行经头颈部CTA检查,将获取的图像,完成最大密度投影和血管三维重建,将数字减影血管造影(DSA)检查结果作为“金标准”,分析经头颈部CTA联合三维重建的诊断特点,对脑血管疾病动脉狭窄患者的诊断价值。结果以DSA检查结果作为“金标准”,经头颈部CTA联合三维重建技术对脑血管动脉狭窄患者的灵敏度、特异度、准确率、阳性及阴性预测值更高,118例脑血管动脉狭窄患者显示982条血管,经头颈部CTA联合三维重建技术与DSA检查的符合率为86.97%(854/982),118例脑血管动脉狭窄患者显示颅内侧支动脉1422条,经头颈部CTA联合三维重建技术与DSA检查的符合率为97.54%(1387/1422)。结论针对脑血管疾病动脉狭窄患者,以经头颈部CTA联合三维重建技术进行检查,对患者血管病变的分布情况、动脉狭窄程度的检查效果较好,能够有效分辨患者侧支循环等级,为后续的治疗提供参考依据。 展开更多
关键词 头颈部ct血管造影 三维重建技术 脑血管疾病 动脉狭窄 诊断
下载PDF
经CT扫描探讨正常喉的活动度的研究
16
作者 梁健 申静 +7 位作者 李雯 王斐然 赵宇明 白洪忠 李华 赵敏 郝濛 梁香存 《中国CT和MRI杂志》 2024年第1期31-34,共4页
目的通过对喉部活动度进行测量,进一步精确勾画喉外扩靶区,以实现肿瘤精确放疗提高放疗效果。方法选取51例肿瘤患者为研究对象,通过CT测量喉部在四个方向最大活动度,通过spss23.0对实验所得数据进行统计分析。结果51位研究对象平均前联... 目的通过对喉部活动度进行测量,进一步精确勾画喉外扩靶区,以实现肿瘤精确放疗提高放疗效果。方法选取51例肿瘤患者为研究对象,通过CT测量喉部在四个方向最大活动度,通过spss23.0对实验所得数据进行统计分析。结果51位研究对象平均前联合向上最大移动范围为(13.04±6.72)mm,前联合向下最大移动范围为(1.53±2.41)mm,前联合向左最大移动范围为(1.44±1.74)mm,前联合向右最大移动范围为(1.35±2.27)mm,前联合向前最大移动范围为(3.81±2.74)mm,前联合向后最大移动范围为(0.75±1.59)mm,左侧甲状软骨板最大外移为(0.70±1.21)mm,左侧甲状软骨板最大内移为(1.86±2.85)mm,右侧甲状软骨板最大外移为(0.70±1.35)mm,右侧甲状软骨板最大内移为(1.42±1.71)mm,杓前角最大间距为(14.15±3.51)mm。以第一次测量为准确测量值,第二次、第三次测量值与第一次测量值差值绝对值为误差值,比较两次测量误差值。两次测量误差间差异无统计学意义(P>0.05)。≤60岁研究对象与>60岁研究对象的喉部活动度无显著性差异(P>0.05)。男性杓前角最大间距为(15.32±4.72)mm,显著高于女性的(12.14±1.61)mm,差异具有统计学意义(P<0.05)。转移的研究对象左侧甲状软骨板最大内移为(2.36±2.11)mm,显著高于未转移的(1.19±1.73)mm,差异具体统计学意义(P<0.05)。性别与前联合向上最大移动范围、杓前角最大间距呈现显著负相关(P<0.05),与左侧甲状软骨板最大外移呈显著正相关(P<0.05);年龄与前联合向上最大移动范围呈显著正相关(P<0.05),与前联合向下最大移动范围、左侧甲状软骨板最大外移呈显著负相关(P<0.05)。皮尔逊相关性分析发现甲状软骨板前联合向左移动度与左侧甲状软骨板最大外移具有显著正相关性(r=0.301,P=0.032);甲状软骨板前联合向右移动度与右侧甲状软骨板最大外移具有显著正相关性(r=0.072,P=0.000)。结论自然吞咽会引起喉部运动,这种运动的具体范围在肿瘤放射治疗中需被注意。 展开更多
关键词 ct 喉部活动 放射治疗 靶区
下载PDF
基于CT技术的黄原胶加固土干湿循环条件下力学性能和微观结构劣化机制研究
17
作者 刘瑾 车文越 +6 位作者 郝社锋 马晓凡 喻永祥 王颖 陈志昊 李婉婉 钱卫 《岩土工程学报》 EI CAS CSCD 北大核心 2024年第5期1119-1126,共8页
干湿循环对岩土体的工程特性具有重要影响。采用CT扫描技术和力学测试,对加入不同含量黄原胶(0%,0.5%,1.5%)加固的黏土在经历不同次数(0,1,4,8,12次)干湿循环作用下的力学性能和微观结构劣化机制进行了研究,得到结论:(1)黄原胶能够有效... 干湿循环对岩土体的工程特性具有重要影响。采用CT扫描技术和力学测试,对加入不同含量黄原胶(0%,0.5%,1.5%)加固的黏土在经历不同次数(0,1,4,8,12次)干湿循环作用下的力学性能和微观结构劣化机制进行了研究,得到结论:(1)黄原胶能够有效提高土体的抗压强度和耐干湿循环效果。随着黄原胶含量的增加,干湿循环作用后的强度损失逐渐减小,当循环次数从0次增加到4次时,对于加入黄原胶含量分别为0%,0.5%,1.5%的试样,抗压强度分别损失了42.75%,17.2%,14.04%。(2)加固土的抗压强度与干湿循环次数之间保持指数下降的关系,当循环次数达到4次后,随着循环次数的进一步增加,抗压强度和弹性模量均在较小的变化范围内波动。(3)随着干湿循环次数的增加,黄原胶加固土的孔隙率表现出先增加后减小的趋势,连通孔隙不断扩展,而孤立孔隙表现出先增加后减小的趋势。(4)随着试样的干燥,黄原胶在土颗粒间形成网状基质,提高土体的强度和耐干湿循环能力。 展开更多
关键词 生物聚合物 黄原胶 抗压强度 ct扫描 微观结构 劣化机制
下载PDF
CTA/CTP评估在缺血性脑血管病介入治疗中的应用
18
作者 周新华 陈良义 张丹彤 《中国CT和MRI杂志》 2024年第4期20-22,共3页
目的探讨CT血管成像(CTA)/CT灌注成像(CTP)在缺血性脑血管病介入治疗中的应用价值。方法选取2021年1月至2023年9月我院收治的200例缺血性脑血管病患者,均在入院后接受CTA及CTP检查,分析其影像资料,探究CTA及CTP缺血性脑血管病介入治疗... 目的探讨CT血管成像(CTA)/CT灌注成像(CTP)在缺血性脑血管病介入治疗中的应用价值。方法选取2021年1月至2023年9月我院收治的200例缺血性脑血管病患者,均在入院后接受CTA及CTP检查,分析其影像资料,探究CTA及CTP缺血性脑血管病介入治疗中的应用价值。结果脑血容量(CBV)比较:缺血半暗带>健侧>梗死区(P<0.05);脑血流量(CBF)比较:健侧>缺血半暗带>梗死区(P<0.05);平均通过时间(MTT)、目标组织中浓度达峰时间(TTP)、目标组织中所有残余功能全部达峰时间(Tmax)比较:健侧<缺血半暗带<梗死区(P<0.05)。CTA检出左侧、右侧大脑中动脉(MCA)闭塞或狭窄分别59例(29.50%)、91例(45.50%),左侧、右侧颈内动脉(ICA)闭塞分别16例(8.00%)、12例(6.00%),双侧ICA狭窄为6例(3.00%);代偿分支血管显影基本满意129例(64.50%),显影不足71例(35.50),其余16例(8.00%)患者CTA影像资料显示无异常,敏感度为92.00%。预后不良组患侧CBV、CBF小于预后良好组,MTT、TTP、Tmax长于预后良好组,代偿血管建立比例低于预后良好组(P<0.05)。采用受试者工作特征曲线分析显示,CBV、CBF、MTT、TTP、Tmax对介入治疗预后均有一定的预测效能(P<0.05),其曲线下面积分别为0.839、0.815、0.673、0.713、0.710,其中CBV预测效能最高,敏感性为83.20%,特异性为73.33%。结论CTA/CTP可反映大脑、颈内动脉狭窄或闭塞、代偿分支建立情况,也可反映血流灌注情况,在介入治疗合理时机的判断方面可提供准确依据,提高患者预后。 展开更多
关键词 ct血管成像 ct灌注成像 缺血性脑血管病 介入治疗 指导 预后
下载PDF
基于投影误差优化网络的碳/碳材料CT稀疏角度重建方法
19
作者 金珂 陈博 +4 位作者 金虎 曾天辰 周星明 徐林 孙跃文 《同位素》 CAS 2024年第4期332-340,共9页
在采用^(60)Co作为射线源的碳/碳复合材料的计算机断层扫描(CT)中,降低采样角度数量可以显著缩短检测时间,提升检测效率。然而常规的解析重建算法,稀疏角度的重建图像中包含大量的噪声和伪影,干扰图像中缺陷的检出,影响检测系统在快速... 在采用^(60)Co作为射线源的碳/碳复合材料的计算机断层扫描(CT)中,降低采样角度数量可以显著缩短检测时间,提升检测效率。然而常规的解析重建算法,稀疏角度的重建图像中包含大量的噪声和伪影,干扰图像中缺陷的检出,影响检测系统在快速检测条件下对被检构件的质量评价。本研究提出了一种基于投影误差优化神经网络的稀疏角度CT图像重建方法,采用未训练的编码-解码卷积神经网络优化重建图像的投影误差,结合图像的总变分先验,采用自适应动量估计(ADAM)算法进行优化。与传统的深度学习重建算法相比,该方法无需训练样本集,具备更强的泛化能力和鲁棒性。CT检测实验结果表明,该方法相比于传统的解析和重建算法,重建图像质量大幅提升,在保留被检测构件细节信息的同时,显著抑制了重建图像中的伪影与噪声。 展开更多
关键词 碳/碳复合材料 ^(60)Co ct检测 深度学习 稀疏角度重建
下载PDF
基于探测器响应机理的碳/碳构件CT图像环状伪影的校正方法
20
作者 金珂 周星明 +4 位作者 孙跃文 徐林 袁生平 卢鹉 曾天辰 《原子能科学技术》 EI CAS CSCD 北大核心 2024年第4期929-936,共8页
在碳/碳复合材料的计算机断层扫描(CT)中,由于探测器单元的响应非线性及不一致性导致重建图像出现严重的环状伪影,干扰图像中缺陷的检出,影响检测系统对被检构件的质量评价。结合碳/碳复合材料组分单一且密度均匀的特点,提出了一种基于... 在碳/碳复合材料的计算机断层扫描(CT)中,由于探测器单元的响应非线性及不一致性导致重建图像出现严重的环状伪影,干扰图像中缺陷的检出,影响检测系统对被检构件的质量评价。结合碳/碳复合材料组分单一且密度均匀的特点,提出了一种基于探测器响应机理的CT图像环状伪影的校正方法,利用采集的劣化投影数据做预重建,对重建结果做阈值分割以获得被检测物体的三维模型。结合已知的材料和密度信息,对被检物体进行重投影,得到投影数据的理论值与实测值之间的映射关系,用于探测器响应校正以优化检测图像。与传统低通滤波的环状伪影校正方法相比,该方法考虑了环状伪影的物理成因并充分利用了检测对象的先验信息。研究结果表明,该校正方法在保留图像细节和纹理的同时,能够有效减少环状伪影,提升图像质量,消除伪影对于图形中缺陷识别的干扰,为提升检测系统对碳/碳复合材料构件缺陷的检出能力提供理论依据。 展开更多
关键词 碳/碳复合材料 ct检测 环状伪影 探测器响应
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部