期刊文献+
共找到1,636篇文章
< 1 2 82 >
每页显示 20 50 100
Numerical Model Research on Rotational Performance of Beam-Column High-Strength Bolt Extension End-Plate Connection Node
1
作者 Xiao Lang 《Open Journal of Modelling and Simulation》 2021年第3期231-245,共15页
The high-strength bolted end plate connection is widely used in the construction industry with its green environmental protection and excellent seismic performance. The joints of the joints are semi-rigid, the force p... The high-strength bolted end plate connection is widely used in the construction industry with its green environmental protection and excellent seismic performance. The joints of the joints are semi-rigid, the force performance is extremely complicated, and the experimental research cost is relatively high, and the cycle is very long. Therefore, the establishment of an efficient numerical model is of great significance for evaluating the force performance of high-strength bolt end plates. In this paper, the influence of different material models on the rotation performance of the joint is studied by numerical simulation, and the bending moment-rotation curve is obtained. The numerical simulation and the experimental results are in good agreement, so as to provide a reference for the design and application of this kind of joint. 展开更多
关键词 high-strength bolt Rotation Performance Material Model Numerical Model
下载PDF
A global-local finite element analysis of hybrid composite-to-metal bolted connections used in aerospace engineering 被引量:1
2
作者 LIANG Ke 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第6期1225-1232,共8页
Efficient bolted joint design is an essential part of designing the minimum weight aerospace structures, since structural failures usually occur at connections and interface. A comprehensive numerical study of three-d... Efficient bolted joint design is an essential part of designing the minimum weight aerospace structures, since structural failures usually occur at connections and interface. A comprehensive numerical study of three-dimensional(3D) stress variations is prohibitively expensive for a large-scale structure where hundreds of bolts can be present. In this work, the hybrid composite-to-metal bolted connections used in the upper stage of European Ariane 5ME rocket are analyzed using the global-local finite element(FE) approach which involves an approximate analysis of the whole structure followed by a detailed analysis of a significantly smaller region of interest. We calculate the Tsai-Wu failure index and the margin of safety using the stresses obtained from ABAQUS. We find that the composite part of a hybrid bolted connection is prone to failure compared to the metal part. We determine the bolt preload based on the clamp-up load calculated using a maximum preload to make the composite part safe. We conclude that the unsuitable bolt preload may cause the failure of the composite part due to the high stress concentration in the vicinity of the bolt. The global-local analysis provides an efficient computational tool for enhancing 3D stress analysis in the highly loaded region. 展开更多
关键词 boltED connection global-local finite element approach failure bolt PRELOAD
下载PDF
STRESS-STRAIN FINITE ELEMENT ANALYSIS AND FATIGUE LIFE PREDICTION FOR BOLTED CONNECTIONS 被引量:1
3
作者 Wang Ziqin Xie Qingsheng Mechanical Engineering Department,Guizhou University of Technology,Guiyang 550003,China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2002年第1期75-78,共4页
A cyclic plasticity model is used into finite element (FE) method to obtainthe details of elastic-plastic stress-strain in the bolts under cyclic axial loading. Two criteriain multiaxial fatigue are employed to predic... A cyclic plasticity model is used into finite element (FE) method to obtainthe details of elastic-plastic stress-strain in the bolts under cyclic axial loading. Two criteriain multiaxial fatigue are employed to predict fatigue lives of bolts. The predicted fatigue livesare in favorable agreement with the experimental results for machined bolts. 展开更多
关键词 Finite element FATIGUE bolted connection
下载PDF
Fatigue Strength Evaluation of Resin-Injected Bolted Connections Using Statistical Analysis 被引量:2
4
作者 Jose Antonio Fonseca de Oliveira Correia Bruno Alexandre Silva Pedrosa +6 位作者 Patricia Cordeiro Raposo Abilio Manuel Pinho De Jesus Helena Maria dos Santos Gervisio Grzegorz Stanislaw Lesiukc Carlos Alberto da Silva Rebelo Rui Artur Bartolo Calcada Luis Alberto Proenca Simoes da Silva 《Engineering》 SCIE EI 2017年第6期795-805,共11页
Different strategies can be used to perform reparations and reinforcements of ancient bolted and riveted metallic bridges. As the riveting process is not currently a common practice, it requires proper equipment and s... Different strategies can be used to perform reparations and reinforcements of ancient bolted and riveted metallic bridges. As the riveting process is not currently a common practice, it requires proper equipment and skilled workers. Another solution is the use of welding. However, the weldability of old steels is poor. Bolts are very attractive alternative solutions, and are most commonly used to repair old metallic bridges. Fitted bolts are expensive solutions; the alternative is the use of resin-injected bolts. The behavior of bolted joints with preloaded resin-injected bolts has been studied using quasi-static and creep tests; however, few studies on the slip and fatigue behavior of these joints can be found in the literature. This paper presents an overview of a few experimental programs that were carried out by several authors aiming at evaluating the fatigue behavior of single and double shear resin-injected bolted connections. A comparison between the experimental data of joints with preloaded standard bolts and preloaded resin- injected bolts shows a fatigue strength reduction in the latter. Since Eurocode 3 (EC3) suggests the same fatigue strength curve for joints made of resin-injected bolts and standard bolts, this may raise some con- cerns. Furthermore, research on the feasibility of using both bonded and bolted connections is shown. This last study was performed with high-strength low-alloy structural steel plates and an acrylic struc- tural adhesive for metal bonding. For both case studies, a statistical analysis is performed on fatigue experimental data using linearized boundaries and the Castillo and Fernandez-Canteli model. Fatigue design curves are proposed and compared with the design suggestions of several European and North American standards, 展开更多
关键词 FATIGUE connectionS Structural reinforcements Structural adhesives S-N curves Resin-injected bolts
下载PDF
Study on Fracture Delay of High-Strength Bolts in Road Bridge Maintenance
5
作者 Rongpeng Xu 《Journal of Architectural Research and Development》 2024年第5期1-6,共6页
In the maintenance work of highway and bridge engineering structures,the fracture delay of high-strength bolts is a content that needs to be focused on and researched.Based on this,the paper analyzes the fracture dela... In the maintenance work of highway and bridge engineering structures,the fracture delay of high-strength bolts is a content that needs to be focused on and researched.Based on this,the paper analyzes the fracture delay of high-strength bolts in highway bridge maintenance,including an overview of the fundamental research on fracture delay and related specific studies.It is hoped that this study can provide scientific reference for the reasonable maintenance of high-strength bolts,so as to ensure the overall maintenance effect of highway bridge projects. 展开更多
关键词 Highway bridge engineering Bridge maintenance high-strength bolts Fracture delay Maintenance recommendations
下载PDF
Cost Optimization of Steel Beam-to-Column Connections using AVOA
6
作者 Ziyu Wang Zhaoyang Ren 《Journal of Architectural Research and Development》 2024年第2期18-23,共6页
The joint-bolt-African Vulture optimization algorithm(AVOA)model is proposed for the design of building connections to improve the stability of steel beam-to-column connections.For this algorithm,the type of steel is ... The joint-bolt-African Vulture optimization algorithm(AVOA)model is proposed for the design of building connections to improve the stability of steel beam-to-column connections.For this algorithm,the type of steel is first determined,and the number of bolts needed by the corresponding steel type is referenced in Eurocode 3.Then,the bearing capacity of the joint can be calculated.The joint-bolt-AVOA model is established by substituting the bolt number required by the steel into the algorithm to obtain the optimal bolt number required while ensuring joint stability.The results show that the number of bolts required by the joint-bolt-AVOA model based on the stability of steel is lower than that calculated by Eurocode 3.Therefore,AVOA can effectively optimize the number of bolts needed in building connections and save resources. 展开更多
关键词 Steel connections African vulture optimization algorithm Optimization of bolts
下载PDF
Mechanical Experimental Study on Tensile Bolted Connections of Cross-laminated Timber
7
作者 Chenxiao Su Haibei Xiong 《Structural Durability & Health Monitoring》 EI 2020年第1期81-94,共14页
In order to explore a kind of high-strength,earthquake-resistant,eco-nomical and suitable connection,4 groups of cross-laminated timber wall-to-floor and wall-to-wall bolted connections were tested under monotonic and... In order to explore a kind of high-strength,earthquake-resistant,eco-nomical and suitable connection,4 groups of cross-laminated timber wall-to-floor and wall-to-wall bolted connections were tested under monotonic and cyclic load-ing.The defommation characteristics and failure modes of the cross-laminated tim-ber wall-to-floor and wall-to-wall bolted connections were exploited.Load-slip curves,bearing capacity,yielding point,stiffness and ductility of each group of specimens were analyzed.The test results indicate that the loading process of cross-laminated timber bolted connections under tension can be categorized as five stages,namely the elastic stage,the slip stage,the embedding stage,the yield-ing stage and the ultimate stage.The ultimate tensile capacity of cross-laminated timber bolted wall-to-floor connections is 2.67 times that of the wall-to-wall bolted connections.Compared with cross-laminated timber self-tapping screwed connections,the ultimate tensile capacity of the cross-laminated timber wall-to-floor bolted connections is 2.70 times that of the self-tapping screwed connec-tions,and the ultimate tensile capacity of the cross-laminated timber wall-to-wall bolted connections is 3.83 times that of the self-tapping screwed connections.The crosslaminated timber bolted connections have larger yielding displacement and wider plastic range,and they are more energy dissipative and more ductile.Furthermore,the cost of the cross-laminated timber wall-to-floor bolted connec-tions is 46%that of the self-tapping screwed connections,while the cost of cross-laminated wall-to-wall bolted connections is 53%that of the self-screwed connections. 展开更多
关键词 Cross-laminated timber bolted connections mechanical properties economical and suitable
下载PDF
The Simple Model for Bolted Connections in Fire
8
作者 Mahmoud Yahyai Mohsen Behzadpoori +1 位作者 Amir Saedi Daryan Ahmad Baleh Moghadas 《Engineering(科研)》 2011年第9期865-875,共11页
Recent structural collapses caused by fire have focused attention on research concerning fire safety in building design. Steel connections are an important component of any structural steel building as they provide li... Recent structural collapses caused by fire have focused attention on research concerning fire safety in building design. Steel connections are an important component of any structural steel building as they provide links between the principal structural members. Considering the importance of this matter this paper describes a spring-stiffness model developed to predict the behavior of bolted angle connections bare-steel joints at elevated temperature. The joint components are considered as springs with predefined mechanical properties i.e. stiffness and strength. The elevated temperature joint’s response can be predicted by assem-bling the stiffness of the components which are assumed to degrade with increasing temperature based on the recommendations presented in the design parameters code. Comparison of the results from the model with existing experimental data showed good agreement. The proposed model can be easily modified to describe the elevated temperature behavior of other types of joint as well as joints under large rotations. 展开更多
关键词 boltED connection ELEVATED-TEMPERATURE FIRE Spring-Stiffness Model Rotation-Temperature CURVES MOMENT-ROTATION CURVES
下载PDF
Residual Capacity of Friction⁃Type High⁃Strength Bolted T⁃stub Connection with Nut Corrosion Damage
9
作者 Gangnian Xu Baoyao Lin Yefeng Du 《Journal of Harbin Institute of Technology(New Series)》 CAS 2023年第3期68-84,共17页
Corrosion is a primary cause of the slippage of friction⁃type high⁃strength bolted(FHSB)T⁃stub connections.This paper attempts to quantify the residual capacity of FHSB T⁃stub connections with corroded nuts.Firstly,co... Corrosion is a primary cause of the slippage of friction⁃type high⁃strength bolted(FHSB)T⁃stub connections.This paper attempts to quantify the residual capacity of FHSB T⁃stub connections with corroded nuts.Firstly,corrosion simulation tests were conducted on 48 manually cut nuts to find out the relationship between the damage degree of nut section and the residual clamping force(RCF)of bolt.Then,static load tests were carried out on 24 FHSB T⁃stub connections with nuts of different degrees of damage to obtain the failure modes.By finite⁃element(FE)models,a comparative analysis was performed on the initial friction load(IFL)and ultimate strength(US)of each connection with corroded nuts.Finally,the parameters of 96 FE models for FHSB T⁃stub connections were analyzed and used to derive the calculation formulas for the degree of damage for each nut and the IFL and US of each connection.The results show that the RCF decay of a bolt is a quadratic function of the equivalent radius loss ratio and the shear failure after nut corrosion;the IFL of each connection had a clear linear correlation with the RCF of the corresponding bolts,and the correlation depends on the applied load and static friction on connecting plate interface induced by the clamping force;the static friction had little impact on the US of the connection;the proposed IFL and US formulas can effectively derive the residual anti⁃slip capacity of FHSB T⁃stub connections from the degree of damage of the corroded nut section.The research results provide a scientific basis for the replacement and maintenance of corroded bolts of FHSB T⁃stub connections. 展开更多
关键词 nut corrosion T⁃stub connection high⁃strength bolt sectional damage residual clamping force(RCF) anti⁃slip capacity
下载PDF
Deformation-softening behaviors of high-strength and high-toughness steels used for rock bolts 被引量:4
10
作者 Ding Wang Manchao He +2 位作者 Zhigang Tao Aipeng Guo Xuchun Wang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2022年第6期1872-1884,共13页
In deep ground engineering,the use of high-strength and high-toughness steels for rock bolt can significantly improve its energy absorption capacity.However,the mechanisms and effects of rock loading conditions on thi... In deep ground engineering,the use of high-strength and high-toughness steels for rock bolt can significantly improve its energy absorption capacity.However,the mechanisms and effects of rock loading conditions on this kind of high energy-absorbing steel for rock bolt remain immature.In this study,taking Muzhailing highway tunnel as the background,physically based crystal plasticity simulations were performed to understand the effect of rock loading rate and pretension on the deformation behaviors of twinning induced plasticity(TWIP)steel used for rock bolt.The material physical connecting to the underlying microscopic mechanisms of dislocation glide and deformation twinning were incorporated in numerical modeling.The rock loading conditions were mimicked by the real-time field monitoring data of the NPR bolt/cable equipment installed on the tunnel surrounding rock surface.The results indicate that the bolt rod exhibits pronounced deformation-softening behavior with decrease of the loading rate.There is also a sound deformation-relaxation phenomenon induced by the dramatic decrease of loading rate after pre-tensioning.The high pretension(>600 MPa or 224 k N)can help bolt rod steel resist deformation-softening behavior,especially at low loading rate(<10~(-1)MPa/s or 10~(-2)kN/s).The loading rate was found to be a significant factor affecting deformation-softening behavior while the pretension was found to be the major parameter accounting for the deformation-relaxation scenario.The results provide the theoretical basis and technical support for practical applications. 展开更多
关键词 Rock bolt high-strength and high-toughness steels Loading rate PRETENSION Deformation-softening Crystal plasticity
下载PDF
Mechanical Behavior of Light Trusses Made of Poplar Laminated Veneer Lumber and Connected with Bolts and Tooth Plates 被引量:1
11
作者 Yan Liu Yanfei Guo +1 位作者 Xufeng Sun Meng Gong 《Journal of Renewable Materials》 SCIE EI 2020年第9期1111-1127,共17页
Poplar Laminated Veneer Lumber(Poplar LVL)is a new type of engineering materials with high strength,good reliability and small variability.Poplar LVL is manufactured from the fast-growing poplar,which is widely used i... Poplar Laminated Veneer Lumber(Poplar LVL)is a new type of engineering materials with high strength,good reliability and small variability.Poplar LVL is manufactured from the fast-growing poplar,which is widely used in packaging,furniture and others,however,is rarely adopted in construction.In order to explore the feasibility of poplar LVL trusses in construction of roof,four 4.5-m-span Fink-and-Howe trusses were designed and assembled,which were made of poplar LVL with bolted-and tooth-plated connections.Vertical static loading on the upper chord joints of a truss was imposed by self-balancing test device.The mechanical properties of trusses were examined.The ultimate load,deformation character and failure mode of each truss were measured,observed and analyzed.Furthermore,four types of analytical models with different joint connection assumptions were used to estimate the ultimate load and deflection.The results showed that the poplar LVL trusses were basically in elastic stage before the design load was reached,showing good working performance under the action of design load.The bearing capacity of the trusses of bolted connections was greater than that of the tooth-plated connections.As for the same joint connection type,the bearing capacity of Fink trusses exceeded that of Howe trusses.The poplar LVL light trusses of both types of connections showed good structural performance,which could be reasonably used for building roof systems. 展开更多
关键词 Poplar LVL TRUSS mechanical properties bearing capacity bolted connection truss plate connections model
下载PDF
Characterization of Strength-Shift Behavior of Bolts Connected with and without Preloading
12
作者 A.Trindade 《Journal of Mechanics Engineering and Automation》 2018年第1期9-16,共8页
Bolted joins allow for more efficient joining of parts(mechanical and structural components)when assembly and disassembly,called interchangeability,are concerned.Also and for this reason,they are the most widely used ... Bolted joins allow for more efficient joining of parts(mechanical and structural components)when assembly and disassembly,called interchangeability,are concerned.Also and for this reason,they are the most widely used in the final assembly,already in construction,in a state of final consolidation of the structure.This work began in a pedagogical action to compare the experimental results with those obtained by Eurocode 3(EN 1993-1-8)in simple joints with screws subject to cutting,the study evolved the analysis of the behavior of the screws themselves in the joint.Tests were carried out with great dimensional accuracy,for new bolted connections,with different bolt’s number,according to different arrangements and repeated in cases of simple and preloaded tightening.The experimental work,carried out on a uniaxial tensile testing machine,consisted in subjecting the connections to a growing effort so that the bolts,being subject to the cut,would break through the thread-free zone.The analysis of results and their comparison(in force—displacement diagrams)allow drawing conclusions regarding the true behavior of the bolted connections.The characterization of the thresholds of the initial zone of the force—displacement curves,in the cases of connections with preloading—was the objective of study.The transfer of forces and the influence of friction on the bonds without and with preloading were then characterized.The main objective of this project is to know the meaning of the calculated values in the preloaded and non-preloaded links by Eurocode 3. 展开更多
关键词 boltS connectionS collapsible PRELOADING EUROCODE 3
下载PDF
Research Review of Principles and Methods for Ultrasonic Measurement of Axial Stress in Bolts 被引量:13
13
作者 Qinxue Pan Ruipeng Pan +2 位作者 Chang Shao Meile Chang Xiaoyu Xu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2020年第1期44-59,共16页
Bolts are important fasteners indispensable in the manufacturing field for their advantages, which include convenient assembly and disassembly, easy maintenance, refastenability to prevent looseness, and the avoidance... Bolts are important fasteners indispensable in the manufacturing field for their advantages, which include convenient assembly and disassembly, easy maintenance, refastenability to prevent looseness, and the avoidance of a phase change in the connected material composition. The precise control of the tightening force in bolts is closely related to the safety and reliability of the connected equipment or structure. Although there are many methods for estimating the tightening force applied to a bolt during assembly, poor accuracy in controlling the preload during the tightening process and a lack of monitoring to determine the residual axial force in service remain issues in evaluating the safety of bolted assemblies. As a nondestructive testing technology, ultrasonic measurement can be applied to successfully address these issues. In order to help researchers understand the theoretical basis and technological development in this field and to equip them to conduct further in-depth research, in this review, the basic knowledge describing the state of stress and deformation of bolts, as well as conventional testing methods are summarized and analyzed. Then, through a review of recent research of the ultrasonic measurement of the axial stress in bolts, the influence of the e ective stressed length and temperature are analyzed and proposed methods of calibration and compensation are reviewed. In order to avoid coupling errors caused by traditional piezoelectric transducers, two newly proposed ultrasonic coupling technologies, the electromagnetic acoustic transducer(EMAT) and the permanent mounted transducer system(PMTS), are reviewed. Finally, the new direction of research of the detection of residual axial stress in in-service bolts that have been assembled to yield is discussed. 展开更多
关键词 boltED connectionS AXIAL stress ULTRASONIC WAVES Influencing factors Coupling techniques
下载PDF
Influence of anchorage length and pretension on the working resistance of rock bolt based on its tensile characteristics 被引量:3
14
作者 Jucai Chang Kai He +3 位作者 Dongdong Pang Dong Li Chuanming Li Bingjun Sun 《International Journal of Coal Science & Technology》 EI CAS CSCD 2021年第6期1384-1399,共16页
In coal mining roadway support design,the working resistance of the rock bolt is the key factor affecting its maximum support load.Effective improvement of the working resistance is of great significance to roadway su... In coal mining roadway support design,the working resistance of the rock bolt is the key factor affecting its maximum support load.Effective improvement of the working resistance is of great significance to roadway support.Based on the rock bolt’s tensile characteristics and the mining roadway surrounding rock deformation,a mechanical model for calculating the working resistance of the rock bolt was established and solved.Taking the mining roadway of the 17102(3)working face at the Panji No.3 Coal Mine of China as a research site,with a quadrilateral section roadway,the influence of pretension and anchorage length on the working resistance of high-strength and ordinary rock bolts in the middle and corner of the roadway is studied.The results show that when the bolt is in the elastic stage,increasing the pretension and anchorage length can effectively improve the working resistance.When the bolt is in the yield and strain-strengthening stages,increasing the pretension and anchorage length cannot effectively improve the working resistance.The influence of pretension and anchorage length on the ordinary and high-strength bolts is similar.The ordinary bolt’s working resistance is approximately 25 kN less than that of the high-strength bolt.When pretension and anchorage length are considered separately,the best pretensions of the high-strength bolt in the middle of the roadway side and the roadway corner are 41.55 and 104.26 kN,respectively,and the best anchorage lengths are 1.54 and 2.12 m,respectively.The best anchorage length of the ordinary bolt is the same as that of the high-strength bolt,and the best pretension for the ordinary bolt in the middle of the roadway side and at the roadway corner is 33.51 and 85.12 kN,respectively.The research results can provide a theoretical basis for supporting the design of quadrilateral mining roadways. 展开更多
关键词 Working resistance of rock bolt PRETENSION Anchorage length Ordinary bolt high-strength bolt Quadrilateral section roadway
下载PDF
Research of Surface Coating Influence on Loose Life of Bolt
15
作者 ZHANG Yu 《International Journal of Plant Engineering and Management》 2022年第2期65-85,共21页
The rust⁃proof ability relate to the reliability of bolt connection,and the painting is the most simple and effective rust⁃proof method in industry.Because of lacking general standard,there are different coating thick... The rust⁃proof ability relate to the reliability of bolt connection,and the painting is the most simple and effective rust⁃proof method in industry.Because of lacking general standard,there are different coating thicknesses painted on the surface of workpieces,which influences the loose life of connecting bolt.For the longer loose life,Three kinds of applied coatings(primer coating,primer+top⁃coat coating,primer+intermediate⁃coat+top⁃coat coating)in industry are tested in the experiment,and the best coating is found.All the conclusions gotten by analyzing the testing phenomenon of every coating shown in experiment,have profound meaning for practical industry application. 展开更多
关键词 COATING bolt connection EXPERIMENT loose life
下载PDF
模块化钢结构梁柱子结构抗连续倒塌性能研究 被引量:1
16
作者 宗亮 张一弛 +1 位作者 崔健 张惠申 《工程力学》 EI CSCD 北大核心 2024年第8期56-67,共12页
模块化钢结构作为一种高度预制的装配式建筑,具有工业化程度高、绿色节能环保等优点。但是,由于模块化钢结构体系超静定次数较低,其在极端荷载工况下的抗连续倒塌性能应予以特别关注。模块化钢结构梁柱子结构作为主要的传力路径,具有多... 模块化钢结构作为一种高度预制的装配式建筑,具有工业化程度高、绿色节能环保等优点。但是,由于模块化钢结构体系超静定次数较低,其在极端荷载工况下的抗连续倒塌性能应予以特别关注。模块化钢结构梁柱子结构作为主要的传力路径,具有多梁多柱等有别于传统框架梁柱子结构的特点,需对其抗连续倒塌性能开展研究工作。该文针对采用螺栓-角件连接节点的模块化钢结构梁柱子结构进行Pushdown试验及数值模拟,分析了在双柱失效、单柱失效工况下试件的破坏模式和抗连续倒塌机理。结果表明,梁柱子结构在两种工况下的受力机理不同:在双柱失效工况下,梁柱子结构抗力主要由梁机制提供,加载后期抗力提供方式体现出一定的悬链线机制,并随水平连接板厚度的增加而增强;在单柱失效工况下,子结构抗力主要由模块间水平连接抗剪能力提供,由梁机制及悬链线机制提供的抗力较小。 展开更多
关键词 模块化钢结构 梁柱子结构 螺栓-角件连接节点 试验研究 数值分析 抗连续倒塌机制
下载PDF
钢管混凝土柱-钢梁外加强环螺栓连接节点抗震性能有限元分析 被引量:1
17
作者 丁发兴 罗开源 +2 位作者 吕飞 张威振 胡明文 《建筑科学与工程学报》 CAS 北大核心 2024年第4期10-19,共10页
为深入研究钢管混凝土柱-钢梁外加强环螺栓连接节点的抗震性能,建立了螺栓连接节点的精细化三维实体有限元模型。在对已有试验成果进行验证分析的基础上,研究加劲肋、螺栓连接数量对节点塑性耗能分配机制的影响。结果表明:当钢材本构后... 为深入研究钢管混凝土柱-钢梁外加强环螺栓连接节点的抗震性能,建立了螺栓连接节点的精细化三维实体有限元模型。在对已有试验成果进行验证分析的基础上,研究加劲肋、螺栓连接数量对节点塑性耗能分配机制的影响。结果表明:当钢材本构后期考虑韧性损伤后,有限元计算结果与已有拟静力试验结果更吻合;CFST-1节点(梁高300 mm,有螺栓垫板)耗能能力最优,但仅达到相应焊接节点的一半;与CFST-1节点相比,CFST-3节点(梁高300 mm,无螺栓垫板)及CFST-2节点(梁高250 mm,有螺栓垫板)的总耗能更低;各螺栓节点的塑性耗能分配机制主要依靠梁耗能,而相应的加强环焊接节点主要依靠梁与加强环耗能;当螺栓节点采用环板加劲肋、4排螺栓以及腹板加劲肋构造优化后,刚度、承载力、延性与相应焊接节点一致,总塑性耗能达到刚接节点的79.1%,基本达到刚接节点的抗震水平。 展开更多
关键词 梁柱节点 螺栓连接 抗震性能 塑性耗能分配机制 刚接节点
下载PDF
螺栓连接和拉铆连接在剪切循环荷载作用下的松动行为研究
18
作者 杨俊芬 郝凯丽 +3 位作者 钟炜辉 王维新 苗广威 张钦 《建筑钢结构进展》 CSCD 北大核心 2024年第3期52-61,共10页
拉铆连接凭借其优秀的防松性能,被应用于越来越多的工程领域。为研究国产新型拉铆钉在剪切循环荷载作用下的松动性能,以应用最为广泛的螺栓连接为对照,分别对规格为8 mm的4.8级普通螺栓、4.8级防松螺栓以及小规格拉铆钉进行剪切循环荷... 拉铆连接凭借其优秀的防松性能,被应用于越来越多的工程领域。为研究国产新型拉铆钉在剪切循环荷载作用下的松动性能,以应用最为广泛的螺栓连接为对照,分别对规格为8 mm的4.8级普通螺栓、4.8级防松螺栓以及小规格拉铆钉进行剪切循环荷载下的松动试验研究,分析了三类连接在剪切循环荷载作用下的松动过程,研究了荷载幅值和频率对螺栓连接和拉铆连接松动行为的影响。结合微观测试手段分析其损伤形貌,进一步研究剪切循环荷载下螺栓和拉铆钉的防松原理及微动损伤机制。研究表明:在同种工况下拉铆连接的防松性能优于螺栓连接的防松性能;当荷载幅值增大或荷载频率减小时,螺栓连接和拉铆连接的松动程度增大;相较于螺栓,拉铆钉独特的圆弧结构牙型和铆接成型后牙型配合面的过盈配合机制,使其防松性能有明显提升;螺栓与拉铆钉的磨损机制主要是磨粒磨损和疲劳磨损。 展开更多
关键词 拉铆连接 螺栓连接 防松性能 剪切循环荷载 磨粒磨损 疲劳磨损
下载PDF
单边螺栓连接中心支撑钢框架抗震性能分析
19
作者 蔺新艳 杨新宇 +3 位作者 王新武 孙海粟 刘欢欢 JANG Il Young 《河南理工大学学报(自然科学版)》 CAS 北大核心 2024年第2期166-176,共11页
目的为研究支撑-半刚接钢框架结构体系的抗震性能,方法设计了一榀由嵌套式单边螺栓与T型钢构成的半刚性梁柱节点的中心支撑钢框架,并进行了拟静力试验与有限元数值模拟,通过观测整个试验现象,分析了其滞回、承载力、刚度退化、耗能等抗... 目的为研究支撑-半刚接钢框架结构体系的抗震性能,方法设计了一榀由嵌套式单边螺栓与T型钢构成的半刚性梁柱节点的中心支撑钢框架,并进行了拟静力试验与有限元数值模拟,通过观测整个试验现象,分析了其滞回、承载力、刚度退化、耗能等抗震指标。结果结果表明:试件破坏过程明显经历了弹性段、塑性段、破坏段三个阶段,试件破坏模式主要为支撑受压失稳破坏,塑性变形主要累积在支撑体系上,整体呈现延性破坏特征;支撑断裂后,梁柱及T型钢节点无明显塑性变形,钢框架仍具有较高的安全储备,符合“强节点、弱构件”设计原则,表明了结构具有两道抗震防线;结论支撑与半刚接钢框架协同工作使得试件具有较高的抗侧刚度抵抗水平变形,且承载力较高、滞回性能稳定、耗能能力优良;单边螺栓在试验过程中的受力性能较普通高强螺栓并无较大差别,未出现严重的预紧力松弛现象,并能高效的保持螺栓预紧力。通过有限元数值模拟分析可知,减小支撑长细比,虽能有效提高结构的抗震性能,但长细比较小会导致支撑刚度增大,加速其余构件的损坏。故应以考虑结构的延性为前提,降低支撑的长细比,才能有效提高结构的抗震性能。 展开更多
关键词 中心支撑 单边螺栓 T型钢 半刚性连接 抗震性能
下载PDF
马鞍山长江公铁大桥Z3号桥塔施工关键技术 被引量:1
20
作者 潘博 李维 刘爱林 《世界桥梁》 北大核心 2024年第2期29-35,共7页
巢马城际铁路马鞍山长江公铁大桥主航道桥为(112+392+2×1120+392+112)m三塔钢桁梁斜拉桥,Z3号桥塔为超高多肢钢-混组合塔,高308 m。上塔柱钢结构高87.5 m,分13个吊装节段,最重505 t;中、下塔柱混凝土结构高217.5 m,分38个节段液压... 巢马城际铁路马鞍山长江公铁大桥主航道桥为(112+392+2×1120+392+112)m三塔钢桁梁斜拉桥,Z3号桥塔为超高多肢钢-混组合塔,高308 m。上塔柱钢结构高87.5 m,分13个吊装节段,最重505 t;中、下塔柱混凝土结构高217.5 m,分38个节段液压爬模施工;钢-混结合段高3 m,内部采用PBL键+剪力钉+高强度钢锚杆+高强度混凝土结构形式。在中塔柱设置钢管临时横撑控制塔柱线形及应力;下横梁采用落地支架法分层施工,与对应塔柱同步浇筑;钢-混结合段混凝土采用C60细石补偿收缩混凝土+高强度灌浆料,保证了混凝土施工质量;采用工厂“2+1”立体匹配制造、“提升站+运输栈桥”钢塔节段转运等技术,并研制15000 t•m超大型塔吊,实现了钢塔柱大节段的制造、整体滩地运输和吊装;钢塔节段间采用栓焊组合连接形式,通过设置工艺隔板、双面坡口等措施控制了钢塔焊接变形;利用定位桁架临时锁定钢塔合龙段实现了钢塔的精确合龙,定位桁架受力及变形均满足要求。 展开更多
关键词 斜拉桥 钢-混组合桥塔 超高多肢 钢-混结合段 整体吊装 钢塔合龙 栓焊组合连接 施工技术
下载PDF
上一页 1 2 82 下一页 到第
使用帮助 返回顶部