An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic later...An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.展开更多
Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical proper...Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical property of the L-shaped column. The load-displacement curve for the L-shaped column, the deflection and load-strain curves for the mono columns were obtained by the axial compression experiment. The results show that the L-shaped column exhibits a flexural-torsional buckling failure mode. The numerical simulation by the finite element analysis shows that the bearing capacity and failure mode are in accordance with those of the axial compression experiment and the feasi- bility of the finite element analysis is proved. For the calculation of the bearing capacity of the L-shaped column com- posed of concrete-filled square steel tubes, an analytical method is proposed based on the theory of the elastic stability and spatial truss model. The results of the analytical method are in good agreement with those of the axial compression experiment and the finite element analysis.展开更多
The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concret...The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns.展开更多
This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of compo...This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of composite member is composed of an inner CFRP tube and an outer steel tube with concrete filled in the two tubes.The finite element analysis was made by ABAQUS on the behavior of high strength concrete filled square steel tubular columns with inner CFRP circular tube subjected to bi-axial eccentric loading.The results obtained from the finite element analysis were verified with the experimental results.In addition,the load-deflection curves in the whole process were calculated and analyzed,which can be divided into three segments:Elastic phase,plastic phase,descending phase.Based on the load-deflection curves,the stresses analysis on the core concrete,CFRP tube and steel tube were conducted.The confinement effect of the CFRP tube improves the ductility of HCFST-CFRP stub column.CFRP ratio and eccentricity affect the ultimate bearing capacity of HCFST stub column.Finally,a calculation formula of ultimate bearing capacity was proposed in the paper.展开更多
The paper presents an experimental study on the behavior of square concrete-filled high strength steel tube columns until failure.Four specimens were tested to investigate the effect of high strength steel and plain s...The paper presents an experimental study on the behavior of square concrete-filled high strength steel tube columns until failure.Four specimens were tested to investigate the effect of high strength steel and plain strength concrete on the load carrying capacity of the square concrete-filled steel tube columns.The effect of the concrete which filled in the steel tube was also investigated.Also,the effect of high strength steel and the presence of concrete were also investigated.The main parameters in the tests were:(1) the ultimate strength of steel (800 Mpa),(2) the presence of concrete in steel tube (hollow steel tube and concrete-filled steel tube),and (3) slender ratio.The main objectives of these tests were three-step:(1) to describe a series of tests on composite columns,(2) to analyze the influence of several parameters,and (3) to compare the accuracy of the predictions by using the specifications in the code (AISC-LRFD,EC4 and AIJ etc.) for the design of high-strength composite columns.Experimental results indicate that the ultimate strength of steel and presence of concrete had significant influence on both the axial compressive load capacity and the ductile of the square steel tube.展开更多
A new composite strengthening method of seismic-damaged lateral joints in composite frame consisting of Concrete-Filled SquareSteel Tubes (CFSST) columns and steel beams strengthened with enclosed Reinforced Concre...A new composite strengthening method of seismic-damaged lateral joints in composite frame consisting of Concrete-Filled SquareSteel Tubes (CFSST) columns and steel beams strengthened with enclosed Reinforced Concrete (RC) at the ends of columns andwelding steel plates at the ends of beams was presented. Based on the current design specifications, one half scaled models of 4lateral joints in composite frame consisting of CFSST columns and steel beams were designed and manufactured. One model wasoriginal control specimen, one was strengthened by enclosed RC, and the others were strengthened after pre-damage. The destructiontests under lateral cyclic load on the models were carried. The effectiveness of seismic-damaged joints strengthened with enclosedRC and the reinforcement effect on different levels of seismic damage were studied. The test results show that seismic- damagedjoints in composite frame consisting of CFSST columns and steel beams strengthened with enclosed RC meets the strongcolumn-weak beam joints requirement of seismic design, and the failure modes are of all joints are the bending failure of steel beam.The reinforcement with enclosed RC has a significant on increasing the ultimate capacity and the seismic behaviors of joints. Thestudy indicated the rehabilitated joints recover the level of their original seismic performances before seismic damage in a certainextent damage level. Based on the test data, namely the ultimate capacity, limit displacement, ductility, the energy consumptioncoefficient, limit displacementthe strengthening method of seismic-damaged joints by strengthened with enclosed RC is an effectivemethod for seismic strengthening.展开更多
基金the National Natural Science Foundation of China under Grant Nos.51268004 and 51578163the Guangxi Science and Technology Key Project under Grant No.12118023-3
文摘An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.
基金Foundation of Key Laboratory of Coast Civil Structure Safety (Tianjin University),Ministry of EducationChinese Program for New Century Excellent Talents in University+1 种基金Seed Foundation of Tianjin UniversitySeed Foundation of Xinjiang University
文摘Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical property of the L-shaped column. The load-displacement curve for the L-shaped column, the deflection and load-strain curves for the mono columns were obtained by the axial compression experiment. The results show that the L-shaped column exhibits a flexural-torsional buckling failure mode. The numerical simulation by the finite element analysis shows that the bearing capacity and failure mode are in accordance with those of the axial compression experiment and the feasi- bility of the finite element analysis is proved. For the calculation of the bearing capacity of the L-shaped column com- posed of concrete-filled square steel tubes, an analytical method is proposed based on the theory of the elastic stability and spatial truss model. The results of the analytical method are in good agreement with those of the axial compression experiment and the finite element analysis.
文摘The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns.
基金This research was funded by Key Projects of National Natural Science Foundation of China(51938009)National Natural Science Foundation of China(51878419)and(51808353).
文摘This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of composite member is composed of an inner CFRP tube and an outer steel tube with concrete filled in the two tubes.The finite element analysis was made by ABAQUS on the behavior of high strength concrete filled square steel tubular columns with inner CFRP circular tube subjected to bi-axial eccentric loading.The results obtained from the finite element analysis were verified with the experimental results.In addition,the load-deflection curves in the whole process were calculated and analyzed,which can be divided into three segments:Elastic phase,plastic phase,descending phase.Based on the load-deflection curves,the stresses analysis on the core concrete,CFRP tube and steel tube were conducted.The confinement effect of the CFRP tube improves the ductility of HCFST-CFRP stub column.CFRP ratio and eccentricity affect the ultimate bearing capacity of HCFST stub column.Finally,a calculation formula of ultimate bearing capacity was proposed in the paper.
基金supported by the research fund of Hanyang University(HY-2010-G)
文摘The paper presents an experimental study on the behavior of square concrete-filled high strength steel tube columns until failure.Four specimens were tested to investigate the effect of high strength steel and plain strength concrete on the load carrying capacity of the square concrete-filled steel tube columns.The effect of the concrete which filled in the steel tube was also investigated.Also,the effect of high strength steel and the presence of concrete were also investigated.The main parameters in the tests were:(1) the ultimate strength of steel (800 Mpa),(2) the presence of concrete in steel tube (hollow steel tube and concrete-filled steel tube),and (3) slender ratio.The main objectives of these tests were three-step:(1) to describe a series of tests on composite columns,(2) to analyze the influence of several parameters,and (3) to compare the accuracy of the predictions by using the specifications in the code (AISC-LRFD,EC4 and AIJ etc.) for the design of high-strength composite columns.Experimental results indicate that the ultimate strength of steel and presence of concrete had significant influence on both the axial compressive load capacity and the ductile of the square steel tube.
文摘A new composite strengthening method of seismic-damaged lateral joints in composite frame consisting of Concrete-Filled SquareSteel Tubes (CFSST) columns and steel beams strengthened with enclosed Reinforced Concrete (RC) at the ends of columns andwelding steel plates at the ends of beams was presented. Based on the current design specifications, one half scaled models of 4lateral joints in composite frame consisting of CFSST columns and steel beams were designed and manufactured. One model wasoriginal control specimen, one was strengthened by enclosed RC, and the others were strengthened after pre-damage. The destructiontests under lateral cyclic load on the models were carried. The effectiveness of seismic-damaged joints strengthened with enclosedRC and the reinforcement effect on different levels of seismic damage were studied. The test results show that seismic- damagedjoints in composite frame consisting of CFSST columns and steel beams strengthened with enclosed RC meets the strongcolumn-weak beam joints requirement of seismic design, and the failure modes are of all joints are the bending failure of steel beam.The reinforcement with enclosed RC has a significant on increasing the ultimate capacity and the seismic behaviors of joints. Thestudy indicated the rehabilitated joints recover the level of their original seismic performances before seismic damage in a certainextent damage level. Based on the test data, namely the ultimate capacity, limit displacement, ductility, the energy consumptioncoefficient, limit displacementthe strengthening method of seismic-damaged joints by strengthened with enclosed RC is an effectivemethod for seismic strengthening.