A novel method of steel tape zero calibration
1
作者 LI Yi-ming WANG Zhong +1 位作者 CHEN Xi LU Rui-jun 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2018年第2期103-108,共6页
In view of the movable hook structure on zero position,the traditional system could not recognize the zero scale.According to the essential requirements of the measurement,a new system based on machine vision was prop... In view of the movable hook structure on zero position,the traditional system could not recognize the zero scale.According to the essential requirements of the measurement,a new system based on machine vision was proposed.Standard datum planes and standard scales were designed as standard component,and the indication error can be calculated by comparing the standard component and the measured value between zero position and 500 mm scale.The alignment of scribed lines was realized by machine vision,and the float pixel equivalent method was applied in image process.Experimental results prove that this system meets the requirement of national standard steel tape verification regulation,and the repeatability of zero error can reach 0.006 mm after zero calibration. 展开更多
关键词 zero calibration zero scale collimation movable hook structure standard datum planes and standard scales float pixel equivalent