PARAMETERS OF WATER CIRCULATION NETWORK FOR A DISTRICT HEATING AND COOLING SYSTEM
1
作者 Fu, Lin Pan, Jihong Jiang, Yi 《Journal of Hydrodynamics》 SCIE EI CSCD 2000年第1期87-95,共9页
In a district heating and cooling system, i.e. Beijing combined heating cooling and power (CHCP) system studied here, the high temperature water generated by two cogeneration plants circulates through a network betwee... In a district heating and cooling system, i.e. Beijing combined heating cooling and power (CHCP) system studied here, the high temperature water generated by two cogeneration plants circulates through a network between the plants and heat substations. At heat substations, the supply water of high temperature from the network drives absorption chillers for air-conditioning in summer and meets space heating demands in winter or domestic hot water demands by heat exchangers in the whole year. The parameters, i.e. supply/return water temperatures in the network, have a great impact on primary energy consumption (PEC) of the absorption chillers, circulation pumps and domestic hot water (DHW), which is studied in this paper. 展开更多
关键词 Boiler circulation Energy utilization hot water heating Parameter estimation water cooling systems
原文传递
Analysis of Influencing Factors on NO_x emission in Gas-Fired Heating and Hot Water Combi-Boilers Based on Orthogonal Method
2
作者 ZHOU Weiye LIU Wenbo +2 位作者 WANG Yan LYU Xinyu YANG Lin 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第3期1088-1095,共8页
In order to determine the sensitivity of influencing factors on NOx emission in gas-fired heating and hot water combi-boilers,the orthogonal method was adopted in this paper.Five predominant factors affecting the form... In order to determine the sensitivity of influencing factors on NOx emission in gas-fired heating and hot water combi-boilers,the orthogonal method was adopted in this paper.Five predominant factors affecting the formation of NOx and four levels were selected to be analyzed,including the diameter of flue restrictor,power of fan,ejection distance of nozzle,aperture of nozzle and relative humidity of air.The test plan was designed by employing L16(45)orthogonal array,and 16 groups of experiments were conducted.The test results were analyzed with range analysis and variance analysis.The results indicated that the power of fan has the greatest influence on the formation of NOx of the gas-fired combi-boilers,followed by the diameter of flue restrictor and the relative humidity of air,while the ejection distance of nozzle and aperture of nozzle have little effect on the formation of NOx.In addition,with the selected optimal combination of five factors,a minimum NOx volume fraction is obtained,which confirms the superiority of the orthogonal test.The research finding has a certain guiding significance for the reduction of NOx formation of gas-fired heating and hot water combi-boiler. 展开更多
关键词 gas-fired heating and hot water combi-boilers nitrogen oxides orthogonal method flue restrictor diameter fan power nozzle ejection distance nozzle aperture air relative humidity