The paper examines the dynamic stall characteristics of a finite wing with an aspect ratio of eight in order to explore the 3D effects on flow topology,aerodynamic characteristics,and pitching damping.Firstly,CFD meth...The paper examines the dynamic stall characteristics of a finite wing with an aspect ratio of eight in order to explore the 3D effects on flow topology,aerodynamic characteristics,and pitching damping.Firstly,CFD methods are developed to calculate the aerodynamic characteristics of wings.The URANS equations are solved using a finite volume method,and the two-equation k-ωshear stress transport(SST)turbulence model is employed to account for viscosity effects.Secondly,the CFD methods are used to simulate the aerodynamic characteristics of both a static,rectangular wing and a pitching,tapered wing to verify their effectiveness and accuracy.The numerical results show good agreement with experimental data.Subsequently,the static and dynamic characteristics of the finite wing are computed and discussed.The results reveal significant 3D flow structures during both static and dynamic stalls,including wing tip vortices,arch vortices,Ω-type vortices,and ring vortices.These phenomena lead to differences in the aerodynamic characteristics of the finite wing compared with a 2D airfoil.Specifically,the finite wing has a smaller lift slope during attached-flow stages,higher stall angles,and more gradual stall behavior.Flow separation initially occurs in the middle spanwise section and gradually spreads to both ends.Regarding aerodynamic damping,the inboard sections mainly generate unstable loading.Furthermore,sections experiencing light stall have a higher tendency to produce negative damping compared with sections experiencing deep dynamic stall.展开更多
To alleviate the performance deterioration caused by dynamic stall of a wind turbine airfoil,the flow control by a microsecond-pulsed dielectric barrier discharge(MP-DBD) actuator on the dynamic stall of a periodicall...To alleviate the performance deterioration caused by dynamic stall of a wind turbine airfoil,the flow control by a microsecond-pulsed dielectric barrier discharge(MP-DBD) actuator on the dynamic stall of a periodically pitching NACA0012 airfoil was investigated experimentally.Unsteady pressure measurements with high temporal accuracy were employed in this study,and the unsteady characteristics of the boundary layer were investigated by wavelet packet analysis and the moving root mean square method based on the acquired pressure.The experimental Mach number was 0.2,and the chord-based Reynolds number was 870 000.The dimensionless actuation frequencies F+ were chosen to be 0.5,1,2,and 3,respectively.For the light dynamic regime,the MP-DBD plasma actuator plays the role of suppressing flow separation from the trial edge and accelerating the flow reattachment due to the high-momentum freestream flow being entrained into the boundary layer.Meanwhile,actuation effects were promoted with the increasing dimensionless actuation frequency F+.The control effects of the deep dynamic stall were to delay the onset and reduce the strength of the dynamic stall vortex due to the accumulating vorticity near the leading edge being removed by the induced coherent vortex structures.The laminar fluctuation and Kelvin-Helmholtz(K-H) instabilities of transition and relaminarization were also mitigated by the MP-DBD actuation,and the alleviated K-H rolls led to the delay of the transition onset and earlier laminar reattachment,which improved the hysteresis effect of the dynamic stall.For the controlled cases of F+=2,and F+=3,the laminar fluctuation was replaced by relatively low frequency band disturbances corresponding to the harmonic responses of the MP-DBD actuation frequency.展开更多
The outlet flow fields of a low-speed repeating-stage compressor with bowed stator stages are measured with five-hole probe under the near stall condition when the rotor/stator axial gap varies. The performances of th...The outlet flow fields of a low-speed repeating-stage compressor with bowed stator stages are measured with five-hole probe under the near stall condition when the rotor/stator axial gap varies. The performances of the straight stator stages are investigated and compared to those of the bowed stator stages. The results show that using bowed stator stages could alleviate the flow separation at both upper and low corners of the suction surface and the endwalls, and decrease the losses along the flow passage as well as the outlet flow angle. As the rotor/stator axial gap decreases, although the diffusion capacity of the compressor increases obviously, the outlet flow field in the straight stator stages deteriorates quickly. By contrast, little changes occur in the bowed stator stages, indicating that as the rotor/stator axial gap decreases, improved performance is achieved in the bowed stator stages.展开更多
Different from the previous qualitative analysis of linear systems in time and frequency domains, the method for describing nonlinear systems quantitatively is proposed based on correlated dimensions. Nonlinear dynami...Different from the previous qualitative analysis of linear systems in time and frequency domains, the method for describing nonlinear systems quantitatively is proposed based on correlated dimensions. Nonlinear dynamics theory is used to analyze the pressure data of a contrarotating axial flow fan. The delay time is 18 and the embedded dimension varies from 1 to 25 through phase-space reconstruction. In addition, the correlated dimensions are calculated before and after stalling. The results show that the correlated dimensions drop from 1. 428 before stalling to 1. 198 after stalling, so they are sensitive to the stalling signal of the fan and can be used as a characteristic quantity for the judging of the fan stalling.展开更多
基金supported by the National Natural Science Foundation of China(No.12072156)the National Key Laboratory Foundation of China(No.61422202103)the Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)。
文摘The paper examines the dynamic stall characteristics of a finite wing with an aspect ratio of eight in order to explore the 3D effects on flow topology,aerodynamic characteristics,and pitching damping.Firstly,CFD methods are developed to calculate the aerodynamic characteristics of wings.The URANS equations are solved using a finite volume method,and the two-equation k-ωshear stress transport(SST)turbulence model is employed to account for viscosity effects.Secondly,the CFD methods are used to simulate the aerodynamic characteristics of both a static,rectangular wing and a pitching,tapered wing to verify their effectiveness and accuracy.The numerical results show good agreement with experimental data.Subsequently,the static and dynamic characteristics of the finite wing are computed and discussed.The results reveal significant 3D flow structures during both static and dynamic stalls,including wing tip vortices,arch vortices,Ω-type vortices,and ring vortices.These phenomena lead to differences in the aerodynamic characteristics of the finite wing compared with a 2D airfoil.Specifically,the finite wing has a smaller lift slope during attached-flow stages,higher stall angles,and more gradual stall behavior.Flow separation initially occurs in the middle spanwise section and gradually spreads to both ends.Regarding aerodynamic damping,the inboard sections mainly generate unstable loading.Furthermore,sections experiencing light stall have a higher tendency to produce negative damping compared with sections experiencing deep dynamic stall.
基金supported by National Natural Science Foundation of China(Nos.12172299 and 1190021162)。
文摘To alleviate the performance deterioration caused by dynamic stall of a wind turbine airfoil,the flow control by a microsecond-pulsed dielectric barrier discharge(MP-DBD) actuator on the dynamic stall of a periodically pitching NACA0012 airfoil was investigated experimentally.Unsteady pressure measurements with high temporal accuracy were employed in this study,and the unsteady characteristics of the boundary layer were investigated by wavelet packet analysis and the moving root mean square method based on the acquired pressure.The experimental Mach number was 0.2,and the chord-based Reynolds number was 870 000.The dimensionless actuation frequencies F+ were chosen to be 0.5,1,2,and 3,respectively.For the light dynamic regime,the MP-DBD plasma actuator plays the role of suppressing flow separation from the trial edge and accelerating the flow reattachment due to the high-momentum freestream flow being entrained into the boundary layer.Meanwhile,actuation effects were promoted with the increasing dimensionless actuation frequency F+.The control effects of the deep dynamic stall were to delay the onset and reduce the strength of the dynamic stall vortex due to the accumulating vorticity near the leading edge being removed by the induced coherent vortex structures.The laminar fluctuation and Kelvin-Helmholtz(K-H) instabilities of transition and relaminarization were also mitigated by the MP-DBD actuation,and the alleviated K-H rolls led to the delay of the transition onset and earlier laminar reattachment,which improved the hysteresis effect of the dynamic stall.For the controlled cases of F+=2,and F+=3,the laminar fluctuation was replaced by relatively low frequency band disturbances corresponding to the harmonic responses of the MP-DBD actuation frequency.
基金National Natural Science Foundation of China (50646021)Chinese Specialized Research Fund for the Doctoral Pro-gram of Higher Education (20060213007)
文摘The outlet flow fields of a low-speed repeating-stage compressor with bowed stator stages are measured with five-hole probe under the near stall condition when the rotor/stator axial gap varies. The performances of the straight stator stages are investigated and compared to those of the bowed stator stages. The results show that using bowed stator stages could alleviate the flow separation at both upper and low corners of the suction surface and the endwalls, and decrease the losses along the flow passage as well as the outlet flow angle. As the rotor/stator axial gap decreases, although the diffusion capacity of the compressor increases obviously, the outlet flow field in the straight stator stages deteriorates quickly. By contrast, little changes occur in the bowed stator stages, indicating that as the rotor/stator axial gap decreases, improved performance is achieved in the bowed stator stages.
基金Supported by the Natural Science Foundation of Jiangsu Province(BK2005018)the Graduate Research and Innovation Plan of Jiangsu Province(CX07B-061Z)~~
文摘Different from the previous qualitative analysis of linear systems in time and frequency domains, the method for describing nonlinear systems quantitatively is proposed based on correlated dimensions. Nonlinear dynamics theory is used to analyze the pressure data of a contrarotating axial flow fan. The delay time is 18 and the embedded dimension varies from 1 to 25 through phase-space reconstruction. In addition, the correlated dimensions are calculated before and after stalling. The results show that the correlated dimensions drop from 1. 428 before stalling to 1. 198 after stalling, so they are sensitive to the stalling signal of the fan and can be used as a characteristic quantity for the judging of the fan stalling.