The purpose of this study was to determine perfluoroalkyl substances(PFASs) in human serum, urine, hair and nail from general populations, and to investigate the possibility for human urine, hair and nail used as th...The purpose of this study was to determine perfluoroalkyl substances(PFASs) in human serum, urine, hair and nail from general populations, and to investigate the possibility for human urine, hair and nail used as the biomonitoring sample for PFASs exposure. We detected the concentrations of PFHx A, PFOA, PFNA, PFDA, PFUn DA, PFDo A, PFHx S and PFOS in 39 matched human serum, urine, hair and nail samples from Shenzhen in China. The detection frequency and the median level of PFOS were all higher than that of the other PFASs in four matrices. The median concentration of PFOS in serum, urine, hair, and nail were 9.24 ng/mL, 13.96 ng/L, 0.58 ng/g and 0.63 ng/g, respectively. The results of spearman correlation test indicated that nail was an ideal matrix for biomonitoring PFOS rather than human urine and hair in general populations for the non-invasive sampling.展开更多
Mueller matrices were measured for natural (or reference) samples of human nails and samples irradiated by a 2 Gy ionizing radiation dose. The elements of the total Mueller matrix as a function of scattering angle w...Mueller matrices were measured for natural (or reference) samples of human nails and samples irradiated by a 2 Gy ionizing radiation dose. The elements of the total Mueller matrix as a function of scattering angle were measured in backscattering mode at a wavelength of 632.8 nm. Several types of depolarizing Mueller matrix decompositions, namely, Ossikovsky, Williams, and Chipman, were calculated as a function of scattering angle for each nail sample. A comparative analysis of the sensitivity of the Mueller matrix decompositions in relation to the problem of emergency dose assessment in nails was performed.展开更多
基金funded by the National Natural Science of Foundation of China(Nos.21537001 and 21407033)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB14010100)
文摘The purpose of this study was to determine perfluoroalkyl substances(PFASs) in human serum, urine, hair and nail from general populations, and to investigate the possibility for human urine, hair and nail used as the biomonitoring sample for PFASs exposure. We detected the concentrations of PFHx A, PFOA, PFNA, PFDA, PFUn DA, PFDo A, PFHx S and PFOS in 39 matched human serum, urine, hair and nail samples from Shenzhen in China. The detection frequency and the median level of PFOS were all higher than that of the other PFASs in four matrices. The median concentration of PFOS in serum, urine, hair, and nail were 9.24 ng/mL, 13.96 ng/L, 0.58 ng/g and 0.63 ng/g, respectively. The results of spearman correlation test indicated that nail was an ideal matrix for biomonitoring PFOS rather than human urine and hair in general populations for the non-invasive sampling.
文摘Mueller matrices were measured for natural (or reference) samples of human nails and samples irradiated by a 2 Gy ionizing radiation dose. The elements of the total Mueller matrix as a function of scattering angle were measured in backscattering mode at a wavelength of 632.8 nm. Several types of depolarizing Mueller matrix decompositions, namely, Ossikovsky, Williams, and Chipman, were calculated as a function of scattering angle for each nail sample. A comparative analysis of the sensitivity of the Mueller matrix decompositions in relation to the problem of emergency dose assessment in nails was performed.