Gypsum was used as substrate,and silica gel was mixed into substrate at a certain mass ratio to prepare humidity-controlling composites;moreover,the moisture absorption and desorption properties of gypsum-based compos...Gypsum was used as substrate,and silica gel was mixed into substrate at a certain mass ratio to prepare humidity-controlling composites;moreover,the moisture absorption and desorption properties of gypsum-based composites were compared with adding different silica gel particle size and proportion.The morphological characteristics,the isothermal equilibrium moisture content curve,moisture absorption and desorption rate,moisture absorption and desorption stability,and humidity-conditioning performance were tested and analyzed.The experimental results show that,compared with pure-gypsum,the surface structure of the gypsum-based composites is relatively loose,the quantity,density and aperture of the pores in the structure increase.The absorption and desorption capacity increase along with the increase of silica gel particle size and silica gel proportion.When 3 mm silica gel particle size is added with a mass ratio of 40%,the maximum equilibrium moisture content of humidity-controlling composites is 0.161 g/g at 98% relative humidity(RH),3.22 times that of pure-gypsum.The moisture absorption and desorption rates are increased,the equilibrium moisture absorption and desorption rates are 2.68 times and 1.61 times that of pure-gypsum at 58.5% RH,respectively.The gypsum-based composites have a good stability,which has better timely response to dynamic humidity changes and can effectively regulate indoor humidity under natural conditions.展开更多
Variable air volume(VAV)air-conditioning(AC)systems are widely employed to achieve a comfortable room thermal and humid environment depending on its better regulation performance and energy efficiency.In the single co...Variable air volume(VAV)air-conditioning(AC)systems are widely employed to achieve a comfortable room thermal and humid environment depending on its better regulation performance and energy efficiency.In the single coil VAV AC system,conventional proportional-integral(PI)control algorithm is usually adopted to track the set-points of the room temperature and humidity by regulating the supply air flow rate and the chilled water flow rate,respectively.However,the control performance is usually not good due to the high coupling of the heat and mass transfer in the air-handling unit(AHU).A model-based control method is developed to realize the decoupling control of the room temperature and humidity according to the bilinear characteristics of the temperature and humidity variation.In this control method,a bilinear room temperature controller is used to track the room temperature set-point based on the real-time cooling load,while a room humidity controller is used to track the room humidity set-point depending on the real-time humidity load.The control performance was validated in a simulated VAV AC system.The test results show that comparing with the conventional PI control,the room temperature and humidity are controlled much more robustly and accurately by using the proposed model-based control method.展开更多
Temperature and humidity are two important factors that influence both indoor thermal comfort and air quality.Through varying compressor and supply fan speeds of a direct expansion(DX)air conditioning(A/C)unit,the air...Temperature and humidity are two important factors that influence both indoor thermal comfort and air quality.Through varying compressor and supply fan speeds of a direct expansion(DX)air conditioning(A/C)unit,the air temperature and humidity in the conditioned space can be regulated simultaneously.However,most existing controllers are designed to minimize the tracking errors between the system outputs with their corresponding settings as quickly as possible.The energy consumption,which is directly influenced by the compressor and supply fan speeds,is not considered in the relevant controller formulations,and thus the system may not operate with the highest possible energy efficiency.To effectively control temperature and humidity while minimizing the system energy consumption,a model predictive control(MPC)strategy was developed for a DX A/C system,and the development results are presented in this paper.A physically-based dynamic model for the DX A/C system with both sensible and latent heat transfers being considered was established and validated by experiments.To facilitate the design of MPC,the physical model was further linearized.The MPC scheme was then developed by formulating the objective function which sought to minimize the tracking errors of temperature and moisture content while saving energy consumption.Based on the results of command following and disturbance rejection tests,the proposed MPC scheme was capable of controlling temperature and humidity with adequate control accuracy and sensitivity.In comparison to linear-quadratic-Gaussian(LQG)controller,better control accuracy and lower energy consumption could be realized when using the proposed MPC strategy to simultaneously control temperature and humidity.展开更多
Temperature and humidity independent control(THIC)air-conditioning system is a promising technology.In this work,a novel temperature and humidity independent control(THIC)system is proposed,namely VMD-ACERS,which inte...Temperature and humidity independent control(THIC)air-conditioning system is a promising technology.In this work,a novel temperature and humidity independent control(THIC)system is proposed,namely VMD-ACERS,which integrates vacuum membrane-based dehumidification and air carrying energy radiant air-conditioning system.This work establishes a novel coefficient of performance(COP)model of VMD-ACERS.The main parameters affecting the COP of conventional fan coil unit cooling system(FCUCS)and VMD-ACERS are investigated.The performance of FCUCS and VMD-ACERS are compared,and the energy-saving potential of VMD-ACERS is proved.Results indicate that,for FCUCS,the importance ranking of parameters is basically stable.However,for VMD-ACERS,the importance ranking will be affected by FCU and refrigerant.The most important parameters of VMD-ACERS are condensation temperature and permeate side pressure.On the contrary,superheating,subcooling are relatively less important parameters.For VMD-ACERS,it is not necessary to pursue the membrane with very high selectivity,because the selectivity of membrane would also be a less important parameter when it reaches 500.The COP of VMD-ACERS is higher than that of FCUCS when the permeate side pressure is higher than 8 k Pa.The VMD-ACERS solves two technical problems about power-saving and thermal comfort of conventional THIC,and can extend the application of THIC air-conditioning system.展开更多
Traditional condensing air-conditioning systems consume large amounts of energy in hot and humid areas,and it is difficult to achieve simultaneous control of temperature and humidity.A combined absorption refrigeratio...Traditional condensing air-conditioning systems consume large amounts of energy in hot and humid areas,and it is difficult to achieve simultaneous control of temperature and humidity.A combined absorption refrigeration(AR)and liquid desiccant dehumidification(LDD)air-conditioning system based on cascade utilization of low-grade heat source is proposed.The system can realize independent control of temperature and humidity and carry out profound recovery of low-grade heat sources.Under the design conditions,the heat utilization rate C reaches 21.05%,which is 2.73 times that of the conventional absorption refrigeration reference system.A parametric sensitivity analysis is performed to optimize the system.The C increases from 9.79%to 18.55%and the coefficient of performance C O P t increases from 0.33 to 0.35 with an increase in chilled water temperature from 7°C to 15°C.With an increase in regenerant solution temperature from 60°C to 70°C,the C achieves the optimal value of 21.05%at 68°C.C decreases from 21.05%to 15.05%as the concentration of the regenerant solution increases from 36%to 40%.Under variable environmental temperature and humidity,the C the proposed system changes within a small range and stays much higher than that of the reference system with the same quality heat source,which indicates that the proposed system has a better adaptability to changing environmental parameters.展开更多
The liquid desiccant air-conditioning system is considered as an energy-efficient alternative to the vapor compression system.The dynamic response characteristics of the system under variable cooling load play an impo...The liquid desiccant air-conditioning system is considered as an energy-efficient alternative to the vapor compression system.The dynamic response characteristics of the system under variable cooling load play an important role in the air temperature and humidity control performance of the system.However,the dynamic response characteristics have not been fully revealed in previous studies.Thus,a dynamic model for a heat pump driven liquid desiccant air-conditioning(HPLDAC)system is established to investigate the dynamic response characteristics of the system in this study.Subsequently,experiments were conducted to validate the accuracy of the dynamic model.The simulation results show a good agreement with the experimental data.The simulation results reveal that evaporating water from the solution is a time-consuming process,compared to adding water to the solution.It spends a long time for the HPLDAC system to decrease the high relative humidity of supply air to a low value,which limits the air temperature and humidity control performance of the system.The upper band for the water replenishing value opening(△φup)is a crucial parameter to improve the limitation.When△φup decreases from 1.0%产to 0.25%,the time consumed to reduce the supply air relative humidity to the new lower set value can be saved by 30.6%.展开更多
基金Funded by the National Natural Science Foundation of China(No.51678254)。
文摘Gypsum was used as substrate,and silica gel was mixed into substrate at a certain mass ratio to prepare humidity-controlling composites;moreover,the moisture absorption and desorption properties of gypsum-based composites were compared with adding different silica gel particle size and proportion.The morphological characteristics,the isothermal equilibrium moisture content curve,moisture absorption and desorption rate,moisture absorption and desorption stability,and humidity-conditioning performance were tested and analyzed.The experimental results show that,compared with pure-gypsum,the surface structure of the gypsum-based composites is relatively loose,the quantity,density and aperture of the pores in the structure increase.The absorption and desorption capacity increase along with the increase of silica gel particle size and silica gel proportion.When 3 mm silica gel particle size is added with a mass ratio of 40%,the maximum equilibrium moisture content of humidity-controlling composites is 0.161 g/g at 98% relative humidity(RH),3.22 times that of pure-gypsum.The moisture absorption and desorption rates are increased,the equilibrium moisture absorption and desorption rates are 2.68 times and 1.61 times that of pure-gypsum at 58.5% RH,respectively.The gypsum-based composites have a good stability,which has better timely response to dynamic humidity changes and can effectively regulate indoor humidity under natural conditions.
基金This work presented in this paper is financially supported by a grant(No.51678263)of National Science Foundation of China.
文摘Variable air volume(VAV)air-conditioning(AC)systems are widely employed to achieve a comfortable room thermal and humid environment depending on its better regulation performance and energy efficiency.In the single coil VAV AC system,conventional proportional-integral(PI)control algorithm is usually adopted to track the set-points of the room temperature and humidity by regulating the supply air flow rate and the chilled water flow rate,respectively.However,the control performance is usually not good due to the high coupling of the heat and mass transfer in the air-handling unit(AHU).A model-based control method is developed to realize the decoupling control of the room temperature and humidity according to the bilinear characteristics of the temperature and humidity variation.In this control method,a bilinear room temperature controller is used to track the room temperature set-point based on the real-time cooling load,while a room humidity controller is used to track the room humidity set-point depending on the real-time humidity load.The control performance was validated in a simulated VAV AC system.The test results show that comparing with the conventional PI control,the room temperature and humidity are controlled much more robustly and accurately by using the proposed model-based control method.
基金supports for the Science and Technology Project of Zhejiang Province(No.LGG21F030009)the Natural Science Foundation of Zhejiang Province(No.LY20F030010)the Key R&D Projects in Zhejiang Province(No.2020C01164)are gratefully acknowledged.
文摘Temperature and humidity are two important factors that influence both indoor thermal comfort and air quality.Through varying compressor and supply fan speeds of a direct expansion(DX)air conditioning(A/C)unit,the air temperature and humidity in the conditioned space can be regulated simultaneously.However,most existing controllers are designed to minimize the tracking errors between the system outputs with their corresponding settings as quickly as possible.The energy consumption,which is directly influenced by the compressor and supply fan speeds,is not considered in the relevant controller formulations,and thus the system may not operate with the highest possible energy efficiency.To effectively control temperature and humidity while minimizing the system energy consumption,a model predictive control(MPC)strategy was developed for a DX A/C system,and the development results are presented in this paper.A physically-based dynamic model for the DX A/C system with both sensible and latent heat transfers being considered was established and validated by experiments.To facilitate the design of MPC,the physical model was further linearized.The MPC scheme was then developed by formulating the objective function which sought to minimize the tracking errors of temperature and moisture content while saving energy consumption.Based on the results of command following and disturbance rejection tests,the proposed MPC scheme was capable of controlling temperature and humidity with adequate control accuracy and sensitivity.In comparison to linear-quadratic-Gaussian(LQG)controller,better control accuracy and lower energy consumption could be realized when using the proposed MPC strategy to simultaneously control temperature and humidity.
基金The National Key Technology Support Program(2015BAJ03B01)the Hunan Provincial Innovation Foundation for Postgraduate Studies(CX20190287)。
文摘Temperature and humidity independent control(THIC)air-conditioning system is a promising technology.In this work,a novel temperature and humidity independent control(THIC)system is proposed,namely VMD-ACERS,which integrates vacuum membrane-based dehumidification and air carrying energy radiant air-conditioning system.This work establishes a novel coefficient of performance(COP)model of VMD-ACERS.The main parameters affecting the COP of conventional fan coil unit cooling system(FCUCS)and VMD-ACERS are investigated.The performance of FCUCS and VMD-ACERS are compared,and the energy-saving potential of VMD-ACERS is proved.Results indicate that,for FCUCS,the importance ranking of parameters is basically stable.However,for VMD-ACERS,the importance ranking will be affected by FCU and refrigerant.The most important parameters of VMD-ACERS are condensation temperature and permeate side pressure.On the contrary,superheating,subcooling are relatively less important parameters.For VMD-ACERS,it is not necessary to pursue the membrane with very high selectivity,because the selectivity of membrane would also be a less important parameter when it reaches 500.The COP of VMD-ACERS is higher than that of FCUCS when the permeate side pressure is higher than 8 k Pa.The VMD-ACERS solves two technical problems about power-saving and thermal comfort of conventional THIC,and can extend the application of THIC air-conditioning system.
基金The authors express gratitude for the support of the National Key Research and Development Program of China(No.2018YFB0905103)the National Natural Science Foundation of China(No.51806213)Beijing Key Laboratory of Distributed Combined Cooling Heating and Power System.
文摘Traditional condensing air-conditioning systems consume large amounts of energy in hot and humid areas,and it is difficult to achieve simultaneous control of temperature and humidity.A combined absorption refrigeration(AR)and liquid desiccant dehumidification(LDD)air-conditioning system based on cascade utilization of low-grade heat source is proposed.The system can realize independent control of temperature and humidity and carry out profound recovery of low-grade heat sources.Under the design conditions,the heat utilization rate C reaches 21.05%,which is 2.73 times that of the conventional absorption refrigeration reference system.A parametric sensitivity analysis is performed to optimize the system.The C increases from 9.79%to 18.55%and the coefficient of performance C O P t increases from 0.33 to 0.35 with an increase in chilled water temperature from 7°C to 15°C.With an increase in regenerant solution temperature from 60°C to 70°C,the C achieves the optimal value of 21.05%at 68°C.C decreases from 21.05%to 15.05%as the concentration of the regenerant solution increases from 36%to 40%.Under variable environmental temperature and humidity,the C the proposed system changes within a small range and stays much higher than that of the reference system with the same quality heat source,which indicates that the proposed system has a better adaptability to changing environmental parameters.
基金This research was supported by the National Key Research Program of China(No.2018YFC0705202)National Natural Science Foundation of China(No.51638010).
文摘The liquid desiccant air-conditioning system is considered as an energy-efficient alternative to the vapor compression system.The dynamic response characteristics of the system under variable cooling load play an important role in the air temperature and humidity control performance of the system.However,the dynamic response characteristics have not been fully revealed in previous studies.Thus,a dynamic model for a heat pump driven liquid desiccant air-conditioning(HPLDAC)system is established to investigate the dynamic response characteristics of the system in this study.Subsequently,experiments were conducted to validate the accuracy of the dynamic model.The simulation results show a good agreement with the experimental data.The simulation results reveal that evaporating water from the solution is a time-consuming process,compared to adding water to the solution.It spends a long time for the HPLDAC system to decrease the high relative humidity of supply air to a low value,which limits the air temperature and humidity control performance of the system.The upper band for the water replenishing value opening(△φup)is a crucial parameter to improve the limitation.When△φup decreases from 1.0%产to 0.25%,the time consumed to reduce the supply air relative humidity to the new lower set value can be saved by 30.6%.