Two cationic thermoresponsive stationary phases were designed and prepared containing poly [ N-isopropylacrylamide-co-( 2-dimethylamino ) ethylmethacrylate ] and poly [ N-isopropylacryl- amide-co-(2-diethylamino) ...Two cationic thermoresponsive stationary phases were designed and prepared containing poly [ N-isopropylacrylamide-co-( 2-dimethylamino ) ethylmethacrylate ] and poly [ N-isopropylacryl- amide-co-(2-diethylamino) ethylmethacrylate] via a simple method, the direct copolymerization of monomers with double bonds on silica surfaces. The two copolymers were synthesized by radical polymerization and then characterized using Fourier transform infrared and gel permeation chroma- tography. The thermoresponsive property and amounts of copolymers grafted on silica were deter- mined through transmittance measurements and thermogravimetric analysis, respectively. The copol- ymers grafted silica particles were then applied as high-performance liquid phase (HPLC) stationary phases for chromatographic separation. Chromatographic properties of mobile phases at different pH values were evaluated by changing temperatures and using benzene and hydrocortisone as the test an- alytes. Retention time of the analytes was prolonged with increasing temperature on both thermore- sponsive columns due to enhanced hydrophobic interaction between analytes and stationary phases. The resolution increased with increasing pH of mobile phase. The optimal separation was obtained at phosphate buffer solution ( 10 raM, pH 8. 0) and at 50 ℃. The pH of mobile phase had a crucial effect on separation efficiency. The results illustrated that poly( N-isopropylacrylamide-co-(2-diethyl- amino) ethylmethacrylate ] copolymer modified silica was more advantageous for the temperature-re- sponsive chromatographic separation because its lower critical solution temperature was relatively lower compared to the poly [ N-isopropylacrylamide-co-(2-dimethylamino) ethylmethacrylate ] sta- tionary phase.展开更多
The reactivity ratios of three hydrophobia monomers, FX14, LA and SA, to a hydrophilic monomer, acrylic acid (AA), were determined. For the fluorocarbon containing hydropho-bic monomer FX14, elemental analysis was ado...The reactivity ratios of three hydrophobia monomers, FX14, LA and SA, to a hydrophilic monomer, acrylic acid (AA), were determined. For the fluorocarbon containing hydropho-bic monomer FX14, elemental analysis was adopted to obtain the relative content of FX14 to AA. For two hydrocarbon monomers, 13C NMR was used. FR, KT linear method and EVM nonlinear method were applied in calculating reactivity ratios. It is found that the reactivity of LA and SA is lower than that of AA, for solution polymerization in cyclohexane. Whereas FX14 is more reactive than AA in benzene. Finally, the distribution of small amounts of these hydrophobic monomers along the polymeric chain is discussed and a random sequence is confirmed.展开更多
基金Supported by the National Natural Science Foundation of China(20675008)
文摘Two cationic thermoresponsive stationary phases were designed and prepared containing poly [ N-isopropylacrylamide-co-( 2-dimethylamino ) ethylmethacrylate ] and poly [ N-isopropylacryl- amide-co-(2-diethylamino) ethylmethacrylate] via a simple method, the direct copolymerization of monomers with double bonds on silica surfaces. The two copolymers were synthesized by radical polymerization and then characterized using Fourier transform infrared and gel permeation chroma- tography. The thermoresponsive property and amounts of copolymers grafted on silica were deter- mined through transmittance measurements and thermogravimetric analysis, respectively. The copol- ymers grafted silica particles were then applied as high-performance liquid phase (HPLC) stationary phases for chromatographic separation. Chromatographic properties of mobile phases at different pH values were evaluated by changing temperatures and using benzene and hydrocortisone as the test an- alytes. Retention time of the analytes was prolonged with increasing temperature on both thermore- sponsive columns due to enhanced hydrophobic interaction between analytes and stationary phases. The resolution increased with increasing pH of mobile phase. The optimal separation was obtained at phosphate buffer solution ( 10 raM, pH 8. 0) and at 50 ℃. The pH of mobile phase had a crucial effect on separation efficiency. The results illustrated that poly( N-isopropylacrylamide-co-(2-diethyl- amino) ethylmethacrylate ] copolymer modified silica was more advantageous for the temperature-re- sponsive chromatographic separation because its lower critical solution temperature was relatively lower compared to the poly [ N-isopropylacrylamide-co-(2-dimethylamino) ethylmethacrylate ] sta- tionary phase.
基金Project (No. 29674039) supported by the National Natural Science Foundation of China.
文摘The reactivity ratios of three hydrophobia monomers, FX14, LA and SA, to a hydrophilic monomer, acrylic acid (AA), were determined. For the fluorocarbon containing hydropho-bic monomer FX14, elemental analysis was adopted to obtain the relative content of FX14 to AA. For two hydrocarbon monomers, 13C NMR was used. FR, KT linear method and EVM nonlinear method were applied in calculating reactivity ratios. It is found that the reactivity of LA and SA is lower than that of AA, for solution polymerization in cyclohexane. Whereas FX14 is more reactive than AA in benzene. Finally, the distribution of small amounts of these hydrophobic monomers along the polymeric chain is discussed and a random sequence is confirmed.