Multi-terminal hybrid high-voltage direct current(HVDC)systems have been developed quickly in recent years in power transmission area.However,for voltage-source converter(VSC)stations in hybrid HVDC systems,no direct ...Multi-terminal hybrid high-voltage direct current(HVDC)systems have been developed quickly in recent years in power transmission area.However,for voltage-source converter(VSC)stations in hybrid HVDC systems,no direct current(DC)filters are required.In addition,the DC reactor is also not installed at the line end because the DC fault can be limited by the converter itself.This means that the boundary element at the line end is absent,and the single-ended protections used in line commutated converter(LCC)based HVDC(LCC-HVDC)systems or VSC-HVDC systems cannot distinguish the fault line in multi-terminal hybrid HVDC systems.This paper proposes a novel singleended DC protection strategy suitable for the multi-terminal hybrid HVDC system,which mainly applies the transient information and active injection concept to detect and distinguish the fault line.Compared with the single-ended protections used in LCC-HVDC and VSC-HVDC systems,the proposed protection strategy is not dependent on the line boundary element and is thus suitable for the multiterminal hybrid HVDC system.The corresponding simulation cases based on power systems computer aided design(PSCAD)/electromagnetic transients including DC(EMTDC)are carried out to verify the superiority of the proposed protection.展开更多
Hybrid high voltage direct current transmission(Hybrid HVDC)is a new type of HVDC technology developed in recent years.It combines the characteristics of large-capacity and low cost of the line commutated converters(L...Hybrid high voltage direct current transmission(Hybrid HVDC)is a new type of HVDC technology developed in recent years.It combines the characteristics of large-capacity and low cost of the line commutated converters(LCC)and non-commutation failure and dynamic reactive power support of the voltage sourced converters(VSCs)in one HVDC system.It has technical advantages in the fields of unidirectional power transmission and in the application of improving the stability of multi-infeed HVDCs,giving it broad application prospects.This paper defines the basic form of hybrid HVDC first and discusses the characteristics and challenges of different hybrid HVDCs.Then,it analyzes the matching characteristics between LCC and VSC in the station-station hybrid HVDC,studies the key technologies,such as VSC topologies and control strategies for clearing the DC overhead line faults,and introduces the key technologies for analyzing and suppressing the high-frequency resonances between VSC and the power grid.In this paper,using the Wudongde UHV multi-terminal HVDC as an example,the proposed key technologies are analyzed and verified.展开更多
Hybrid high-voltage direct current(HVDC)transmission has the characteristic of long transmission distance,complex corridor environment,and rapid fault evolution of direct current(DC)lines.As high fault current can eas...Hybrid high-voltage direct current(HVDC)transmission has the characteristic of long transmission distance,complex corridor environment,and rapid fault evolution of direct current(DC)lines.As high fault current can easily cause irreversible damage to power devices,rapid and reliable line protection and isolation are necessary to improve the security and reliability of hybrid HVDC transmission system.To address such requirement,this paper proposes a single-ended protection method based on transient voltage frequency band characteristics.First,the frequency characteristics of the smoothing reactor,DC filter,and DC line are analyzed,and the characteristic frequency band is defined.A fault criterion is then constructed based on the voltage characteristic frequency band energy,and faulty pole selection is performed according to the fault voltage characteristic frequency band energy ratio.The proposed protection method is verified by simulation,and the results show that it can rapidly and reliably identify internal and external faults,accurately select faulty poles without data communication synchronization,and has good fault-resist-ance and anti-interference performance.展开更多
Hybrid high-voltage direct current(HVDC)transmission systems employ a new type of HVDC transmission topology that combines the advantages of the linecommutated converter system and the voltage-source converter system....Hybrid high-voltage direct current(HVDC)transmission systems employ a new type of HVDC transmission topology that combines the advantages of the linecommutated converter system and the voltage-source converter system.They can improve the efficiency and reliability of long-distance power transmission.However,realizing alternating-current(AC)grid-fault ride through on the inverter side of a hybrid HVDC transmission system is a challenge considering that a voltage-source converter based HVDC(VSC-HVDC)is used on the inverter side.In this study,a control strategy for an overvoltage fixed trigger angle based on the power-balance method is developed by fully utilizing the operation characteristics of a hybrid HVDC transmission system.The strategy reduces the inverter-side overvoltage of the HVDC system under a fault in the inverter-side AC system.Simulations based on Gezhou Dam are conducted to validate the effectiveness of the proposed strategy.展开更多
The use of overhead lines for power transmission in the future high-voltage and large-capacity voltagesource converter(VSC)-based direct current(DC) grid will significantly increase the probability of temporary faults...The use of overhead lines for power transmission in the future high-voltage and large-capacity voltagesource converter(VSC)-based direct current(DC) grid will significantly increase the probability of temporary faults.To eliminate potential adverse impacts such as erroneous protection, line-insulation failure, and even damage to power electronic devices resulting from a DC breaker reclosing operation with the traditional sequential autoreclosing strategy, a new sequential auto-reclosing strat-egy for hybrid HVDC breakers(HHBs) in VSC-based DC grids is proposed. This strategy is based on the step-by-step operation of the transfer branch in the HHB. As a result,du/dt resulting from the HHB reclosing operation is greatly reduced, and therefore those potential negative impacts can be eliminated. Several other advantages are also presented.The feasibility and validity of the proposed strategy are verified in a four-terminal annular VSC-based DC grid electromagnetic transient model.展开更多
The intense application of Voltage Source Converter based HVDC interconnections and grids will result in a hybrid AC-HVDC-system. The operation of such a system becomes complex regarding system security and system ope...The intense application of Voltage Source Converter based HVDC interconnections and grids will result in a hybrid AC-HVDC-system. The operation of such a system becomes complex regarding system security and system operation. This paper describes major challenges and proposes potential solutions, including a combined security assessment, preventive optimization and curative actions. A coordination of both systems enables an efficient application of existing transport capacity.展开更多
In view of the fact that the wavelet packet transform(WPT) can only weakly detect the occurrence of fault, this paper applies a fault diagnosis algorithm including wavelet packet transform and principal component anal...In view of the fact that the wavelet packet transform(WPT) can only weakly detect the occurrence of fault, this paper applies a fault diagnosis algorithm including wavelet packet transform and principal component analysis(PCA) to the inverter-side fault diagnosis of multi-terminal hybrid highvoltage direct current(HVDC) network, which can significantly improve the speed and accuracy of fault diagnosis. Firstly, current amplitude and current slope are used to sample the data,and the WPT is used to extract the energy spectrum of the signal. Secondly, an energy matrix is constructed, and the PCA method is used to calculate whether the squared prediction error(SPE) statistics of various signals that can reflect the degree of deviation of the measured value from the principal component model at a certain time exceed the limit to judge the occurrence of the fault. Further, its maximum value is compared to determine the fault types. Finally, based on a large number of MATLAB/Simulink simulation results, it is shown that the PCA method using the current slope as the sampled data can detect the occurrence of a ground fault with small transition resistance within 2 ms, and identify the fault types within 10 ms,without being affected by the sampling frequency.展开更多
建立了含柔性直流输电(voltage source converter based high voltage direct current,VSC-HVDC)的交直流混合发输电系统的可靠性分析模型,该模型既考虑了VSC-HVDC的稳态功率特性,还计及了发输电网络的故障率和输电线路的有功限制,采用...建立了含柔性直流输电(voltage source converter based high voltage direct current,VSC-HVDC)的交直流混合发输电系统的可靠性分析模型,该模型既考虑了VSC-HVDC的稳态功率特性,还计及了发输电网络的故障率和输电线路的有功限制,采用非序惯蒙特卡罗仿真实现;在满足系统安全约束的前提条件下,对系统进行模拟调度,重点评价了与发输电网络连接的VSC-HVDC对电网可靠性的影响,给出系统和节点的风险指标,为VSC-HVDC规划和运行提供参考依据,最后算例分析证明了该算法的可行性和合理性。展开更多
为提高风电场交直流混合输电并网的系统性能,提出一种更加灵活的电压源换流器高压直流(voltage source converter based high voltage direct current,VSC-HVDC)控制策略。对于风电场侧电压源换流器,设计了一种新的交流电压–功角控制...为提高风电场交直流混合输电并网的系统性能,提出一种更加灵活的电压源换流器高压直流(voltage source converter based high voltage direct current,VSC-HVDC)控制策略。对于风电场侧电压源换流器,设计了一种新的交流电压–功角控制方法。对于交直流混合输电模式,该方法通过调节风电场交流母线电压与电压源换流器输出电压间的功角来实现定有功功率控制。对于纯柔性直流输电模式,风电场交流母线电压自动被调节为具有恒幅恒频的交流电压,实现了对波动风电的同步输送。该方法中输电模式的变化无需切换控制;另外,通过附加电流高通滤波器增强了对系统谐振的阻尼作用。对电网侧电压源换流器,采用一种新的直接电流矢量控制,使直流电压稳定在参考值上。运用PSCAD/EMTDC仿真软件对分别接入笼型感应发电机(squirrel cage induction generator,SCIG)风电场和双馈感应发电机(doubly fed induction generator,DFIG)风电场的交直流混合输电系统建模仿真。一系列运行条件下的仿真结果验证了控制方法的有效性与可行性。展开更多
文摘Multi-terminal hybrid high-voltage direct current(HVDC)systems have been developed quickly in recent years in power transmission area.However,for voltage-source converter(VSC)stations in hybrid HVDC systems,no direct current(DC)filters are required.In addition,the DC reactor is also not installed at the line end because the DC fault can be limited by the converter itself.This means that the boundary element at the line end is absent,and the single-ended protections used in line commutated converter(LCC)based HVDC(LCC-HVDC)systems or VSC-HVDC systems cannot distinguish the fault line in multi-terminal hybrid HVDC systems.This paper proposes a novel singleended DC protection strategy suitable for the multi-terminal hybrid HVDC system,which mainly applies the transient information and active injection concept to detect and distinguish the fault line.Compared with the single-ended protections used in LCC-HVDC and VSC-HVDC systems,the proposed protection strategy is not dependent on the line boundary element and is thus suitable for the multiterminal hybrid HVDC system.The corresponding simulation cases based on power systems computer aided design(PSCAD)/electromagnetic transients including DC(EMTDC)are carried out to verify the superiority of the proposed protection.
基金This work was supported by the National Key Research and Development Program of China(2016YFB0901005)Science and Technology Project of China Southern Grid(SEPRI-K195035).
文摘Hybrid high voltage direct current transmission(Hybrid HVDC)is a new type of HVDC technology developed in recent years.It combines the characteristics of large-capacity and low cost of the line commutated converters(LCC)and non-commutation failure and dynamic reactive power support of the voltage sourced converters(VSCs)in one HVDC system.It has technical advantages in the fields of unidirectional power transmission and in the application of improving the stability of multi-infeed HVDCs,giving it broad application prospects.This paper defines the basic form of hybrid HVDC first and discusses the characteristics and challenges of different hybrid HVDCs.Then,it analyzes the matching characteristics between LCC and VSC in the station-station hybrid HVDC,studies the key technologies,such as VSC topologies and control strategies for clearing the DC overhead line faults,and introduces the key technologies for analyzing and suppressing the high-frequency resonances between VSC and the power grid.In this paper,using the Wudongde UHV multi-terminal HVDC as an example,the proposed key technologies are analyzed and verified.
基金supported by the National Natural Science Foundation of China(52037003)the Major Special and Technology Project of Yunnan Province(202002AF080001).
文摘Hybrid high-voltage direct current(HVDC)transmission has the characteristic of long transmission distance,complex corridor environment,and rapid fault evolution of direct current(DC)lines.As high fault current can easily cause irreversible damage to power devices,rapid and reliable line protection and isolation are necessary to improve the security and reliability of hybrid HVDC transmission system.To address such requirement,this paper proposes a single-ended protection method based on transient voltage frequency band characteristics.First,the frequency characteristics of the smoothing reactor,DC filter,and DC line are analyzed,and the characteristic frequency band is defined.A fault criterion is then constructed based on the voltage characteristic frequency band energy,and faulty pole selection is performed according to the fault voltage characteristic frequency band energy ratio.The proposed protection method is verified by simulation,and the results show that it can rapidly and reliably identify internal and external faults,accurately select faulty poles without data communication synchronization,and has good fault-resist-ance and anti-interference performance.
基金supported by the key project ofSmart Grid Technology and Equipment of National Key Research and Development Plan of China(No.2016YFB0900600)Technology Projects of State Grid Corporation of China(No.52094017000W).
文摘Hybrid high-voltage direct current(HVDC)transmission systems employ a new type of HVDC transmission topology that combines the advantages of the linecommutated converter system and the voltage-source converter system.They can improve the efficiency and reliability of long-distance power transmission.However,realizing alternating-current(AC)grid-fault ride through on the inverter side of a hybrid HVDC transmission system is a challenge considering that a voltage-source converter based HVDC(VSC-HVDC)is used on the inverter side.In this study,a control strategy for an overvoltage fixed trigger angle based on the power-balance method is developed by fully utilizing the operation characteristics of a hybrid HVDC transmission system.The strategy reduces the inverter-side overvoltage of the HVDC system under a fault in the inverter-side AC system.Simulations based on Gezhou Dam are conducted to validate the effectiveness of the proposed strategy.
基金supported by National Key R&D Program of China (No. 2017YFB0902400)
文摘The use of overhead lines for power transmission in the future high-voltage and large-capacity voltagesource converter(VSC)-based direct current(DC) grid will significantly increase the probability of temporary faults.To eliminate potential adverse impacts such as erroneous protection, line-insulation failure, and even damage to power electronic devices resulting from a DC breaker reclosing operation with the traditional sequential autoreclosing strategy, a new sequential auto-reclosing strat-egy for hybrid HVDC breakers(HHBs) in VSC-based DC grids is proposed. This strategy is based on the step-by-step operation of the transfer branch in the HHB. As a result,du/dt resulting from the HHB reclosing operation is greatly reduced, and therefore those potential negative impacts can be eliminated. Several other advantages are also presented.The feasibility and validity of the proposed strategy are verified in a four-terminal annular VSC-based DC grid electromagnetic transient model.
文摘The intense application of Voltage Source Converter based HVDC interconnections and grids will result in a hybrid AC-HVDC-system. The operation of such a system becomes complex regarding system security and system operation. This paper describes major challenges and proposes potential solutions, including a combined security assessment, preventive optimization and curative actions. A coordination of both systems enables an efficient application of existing transport capacity.
基金supported by the National Natural Science Foundation of China-State Grid Joint Fund for Smart Grid (No. U2066210)。
文摘In view of the fact that the wavelet packet transform(WPT) can only weakly detect the occurrence of fault, this paper applies a fault diagnosis algorithm including wavelet packet transform and principal component analysis(PCA) to the inverter-side fault diagnosis of multi-terminal hybrid highvoltage direct current(HVDC) network, which can significantly improve the speed and accuracy of fault diagnosis. Firstly, current amplitude and current slope are used to sample the data,and the WPT is used to extract the energy spectrum of the signal. Secondly, an energy matrix is constructed, and the PCA method is used to calculate whether the squared prediction error(SPE) statistics of various signals that can reflect the degree of deviation of the measured value from the principal component model at a certain time exceed the limit to judge the occurrence of the fault. Further, its maximum value is compared to determine the fault types. Finally, based on a large number of MATLAB/Simulink simulation results, it is shown that the PCA method using the current slope as the sampled data can detect the occurrence of a ground fault with small transition resistance within 2 ms, and identify the fault types within 10 ms,without being affected by the sampling frequency.
文摘建立了含柔性直流输电(voltage source converter based high voltage direct current,VSC-HVDC)的交直流混合发输电系统的可靠性分析模型,该模型既考虑了VSC-HVDC的稳态功率特性,还计及了发输电网络的故障率和输电线路的有功限制,采用非序惯蒙特卡罗仿真实现;在满足系统安全约束的前提条件下,对系统进行模拟调度,重点评价了与发输电网络连接的VSC-HVDC对电网可靠性的影响,给出系统和节点的风险指标,为VSC-HVDC规划和运行提供参考依据,最后算例分析证明了该算法的可行性和合理性。
文摘为提高风电场交直流混合输电并网的系统性能,提出一种更加灵活的电压源换流器高压直流(voltage source converter based high voltage direct current,VSC-HVDC)控制策略。对于风电场侧电压源换流器,设计了一种新的交流电压–功角控制方法。对于交直流混合输电模式,该方法通过调节风电场交流母线电压与电压源换流器输出电压间的功角来实现定有功功率控制。对于纯柔性直流输电模式,风电场交流母线电压自动被调节为具有恒幅恒频的交流电压,实现了对波动风电的同步输送。该方法中输电模式的变化无需切换控制;另外,通过附加电流高通滤波器增强了对系统谐振的阻尼作用。对电网侧电压源换流器,采用一种新的直接电流矢量控制,使直流电压稳定在参考值上。运用PSCAD/EMTDC仿真软件对分别接入笼型感应发电机(squirrel cage induction generator,SCIG)风电场和双馈感应发电机(doubly fed induction generator,DFIG)风电场的交直流混合输电系统建模仿真。一系列运行条件下的仿真结果验证了控制方法的有效性与可行性。