期刊文献+
共找到296篇文章
< 1 2 15 >
每页显示 20 50 100
Coordinated Capacitor Voltage Balancing Method for Cascaded H-bridge Inverter with Supercapacitor and DC-DC Stage 被引量:1
1
作者 Ye Zhang Zixin Li +2 位作者 Fanqiang Gao Cong Zhao Yaohua Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期191-201,共11页
Cascaded H-bridge inverter(CHBI) with supercapacitors(SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors wi... Cascaded H-bridge inverter(CHBI) with supercapacitors(SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors within the CHBI, including both the dc-link capacitors and SCs. Balance control over the dc-link capacitor voltages is realized by the dcdc stage in each submodule(SM), while a hybrid modulation strategy(HMS) is implemented in the H-bridge to balance the SC voltages among the SMs. Meanwhile, the dc-link voltage fluctuations are analyzed under the HMS. A virtual voltage variable is introduced to coordinate the balancing of dc-link capacitor voltages and SC voltages. Compared to the balancing method that solely considers the SC voltages, the presented method reduces the dc-link voltage fluctuations without affecting the voltage balance of SCs. Finally, both simulation and experimental results verify the effectiveness of the presented method. 展开更多
关键词 cascaded h-bridge inverter(CHBI) hybrid modulation strategy(HMS) Capacitor voltage balancing DClink voltage fluctuation Supercapacitor(SC)
下载PDF
Model Predictive Control for Cascaded H-Bridge PV Inverter with Capacitor Voltage Balance
2
作者 Xinwei Wei Wanyu Tao +4 位作者 Xunbo Fu Xiufeng Hua Zhi Zhang Xiaodan Zhao Chen Qin 《Journal of Electronic Research and Application》 2024年第2期79-85,共7页
We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc... We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc-ing control methods,the method proposed could make the PV strings of each submodule operate at their maximum power point by independent capacitor voltage control.Besides,the predicted and reference value of the grid-connected current was obtained according to the maximum power output of the maximum power point tracking.A cost function was con-structed to achieve the high-precision grid-connected control of the CHB inverter.Finally,the effectiveness of the proposed control method was verified through a semi-physical simulation platform with three submodules. 展开更多
关键词 Model predictive control(MPC) Photovoltaic system cascaded h-bridge(CHB)inverter Capacitor voltage balance
下载PDF
A distributed VSG control method for a battery energy storage system with a cascaded H-bridge in a grid-connected mode 被引量:6
3
作者 Yichi Cai Donglian Qi 《Global Energy Interconnection》 EI CAS CSCD 2022年第4期343-352,共10页
With the high penetration of renewable energy,new challenges,such as power fluctuation suppression and inertial support capability,have arisen in the power sector.Battery energy storage systems play an essential role ... With the high penetration of renewable energy,new challenges,such as power fluctuation suppression and inertial support capability,have arisen in the power sector.Battery energy storage systems play an essential role in renewable energy integration.In this paper,a distributed virtual synchronous generator(VSG)control method for a battery energy storage system(BESS)with a cascaded H-bridge converter in a grid-connected mode is proposed.The VSG is developed without communication dependence,and state-of-charge(SOC)balancing control is achieved using the distributed average algorithm.Owing to the low varying speed of SOC,the bandwidth of the distributed communication networks is extremely slow,which decreases the cost.Therefore,the proposed method can simultaneously provide inertial support and accurate SOC balancing.The stability is also proved using root locus analysis.Finally,simulations under different conditions are carried out to verify the effectiveness of the proposed method. 展开更多
关键词 VSG cascaded h-bridge converters Battery energy storage system Renewable energy integration
下载PDF
THD Analysis of Cascaded H-Bridge Inverter with Fuzzy Logic Controller
4
作者 Sivakumar N. Sumathi A. 《Circuits and Systems》 2017年第7期171-183,共13页
In recent days, the multilevel inverter technology is widely applied to domestic and industrial applications for medium voltage conversion. But, the power quality issues of the multilevel inverter limit the usage of m... In recent days, the multilevel inverter technology is widely applied to domestic and industrial applications for medium voltage conversion. But, the power quality issues of the multilevel inverter limit the usage of much sensitive equipment like medical instruments. The lower distortion level of the output voltage and current can generate a quality sinusoidal output voltage in inverters and they can be used for many applications. The harmonics can cause major problems in equipments due to the nonlinear loads connected with the power system. So, it is necessary to minimize the losses to raise its overall efficiency. In this paper, a new topology of seven level asymmetrical cascaded H-bridge multilevel inverter with a Fuzzy logic controller had been implemented to reduce the Total Harmonic Distortion (THD) and to improve the overall performance of the inverter. The proposed model is well suited for use with a solar PV application. In this topology, only six IGBT switches are used with three different voltage ratings of PV modules (1:2:4). The lower number of semiconductor switches leads to minimizing overall di/dt ratings and voltage stress on each switches and switching losses. The gate pulses generated by Sinusoidal Pulse Width Modulation (SPWM) technique with a Fuzzy logic controller are also introduced. A buck-boost converter is used to maintain the constant PV voltage level integrated by an MPPT technique followed by Perturb and Observer algorithm is also implemented. The MPPT is used to harness the maximum power of solar radiations under its various climatic conditions. The new topology is evaluated by a Matlab/Simulink model and compared with a hardware model. The results proved that the THD achieved by this topology is 1.66% and realized that it meets the IEEE harmonic standards. 展开更多
关键词 cascaded h-bridge MULTILEVEL Inverter THD Photo Voltaic Modules SPWM Fuzzy LOGIC Controller MPPT Technique
下载PDF
Research of Mining STATCOM Based on Hybrid Multilevel H-bridge Inverter
5
作者 Yaopu Li Cong Wang +1 位作者 Xu Zhao Kai Zhang 《Energy and Power Engineering》 2013年第4期636-641,共6页
The paper presents a new STATCOM system based on H-bridge inverter. It can be used in mine power network. It has been commonly verified for the positive effects of SVG on the reactive power compensation and voltage fl... The paper presents a new STATCOM system based on H-bridge inverter. It can be used in mine power network. It has been commonly verified for the positive effects of SVG on the reactive power compensation and voltage fluctuation suppression. This paper focuses on a generalized structure of multilevel power converter where individual voltage sources are not necessarily the same. The cascade H-bridge consists of two cells, high-voltage cell and low-voltage cell. The high-voltage cell is responsible for voltage lifting, while the low-voltage cell is responsible for PWM modulation. If two cells are cascaded with DC voltages in a ratio of 2:1, the single-phase output voltage can reach 7 levels. Increasing voltage levels of output waveform can bring up AC current quality, optimize harmonic spectrum and enhance converter efficiency. The hybrid multilevel is characterized by per-phase series connection of a high-voltage H-bridge converter and a low-voltage H-bridge converter. Due to the different capacitor voltage, it is a key problem as to how to maintain the capacitor’s voltage at a reference level. Independent DC source can effectively ensure the DC voltage. Through the reactive power compensation technology, the three-phase voltage and current can remain at the same phase. 展开更多
关键词 h-bridge STATCOM SVG hybrid Coal MINE PWM Control Inverter
下载PDF
Coordinated Control of Second-order Harmonic Voltage and Current Fluctuations in Cascaded H-bridge Inverter with Supercapacitor and DC-DC Stage at Variable Output Frequencies
6
作者 Ye Zhang Zixin Li +3 位作者 Fanqiang Gao Jinhao Zhang Cong Zhao Yaohua Li 《CES Transactions on Electrical Machines and Systems》 EI 2024年第4期481-492,共12页
In the cascaded H-bridge inverter(CHBI)with supercapacitor and dc-dc stage,inherent second-order harmonic power flows through each submodule(SM),causing fluctuations in both the dc-link voltage and the dc-dc current.T... In the cascaded H-bridge inverter(CHBI)with supercapacitor and dc-dc stage,inherent second-order harmonic power flows through each submodule(SM),causing fluctuations in both the dc-link voltage and the dc-dc current.There exist limitations in handling these fluctuations at variable output frequencies when employing proportional-integral(PI)control to the dc-dc stage.This paper aims to coordinately control these second-order harmonic voltage and current fluctuations in the CHBI.The presented method configures a specific second-order harmonic voltage reference,equipped with a maximum voltage fluctuation constraint and a suitable phase,for the dc-dc stage.A PI-resonant controller is used to track the configured reference.This allows for regulating the second-order harmonic fluctuation in the average dc-link voltage among the SMs within a certain value.Importantly,the second-order harmonic fluctuation in the dc-dc current can also be reduced.Simulation and experimental results demonstrate the effectiveness of the presented method. 展开更多
关键词 cascaded h-bridge inverter(CHBI) DC-DC current reduction Second-order harmonic fluctuation Variable frequencies Proportional-integral-resonant
下载PDF
A Novel Cascaded PID Controller for Automatic Generation Control Analysis With Renewable Sources 被引量:5
7
作者 Aurobindo Behera Tapas Kumar Panigrahi +1 位作者 PrakashK·Ray Arun Kumar Sahoo 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第6期1438-1451,共14页
Present day power scenarios demand a high quality uninterrupted power supply and needs environmental issues to be addressed. Both concerns can be dealt with by the introduction of the renewable sources to the existing... Present day power scenarios demand a high quality uninterrupted power supply and needs environmental issues to be addressed. Both concerns can be dealt with by the introduction of the renewable sources to the existing power system. Thus, automatic generation control(AGC) with diverse renewable sources and a modified-cascaded controller are presented in the paper.Also, a new hybrid scheme of the improved teaching learning based optimization-differential evolution(hITLBO-DE) algorithm is applied for providing optimization of controller parameters. A study of the system with a technique such as TLBO applied to a proportional integral derivative(PID), integral double derivative(IDD) and PIDD is compared to hITLBO-DE tuned cascaded controller with dynamic load change.The suggested methodology has been extensively applied to a 2-area system with a diverse source power system with various operation time non-linearities such as dead-band of, generation rate constraint and reheat thermal units. The multi-area system with reheat thermal plants, hydel plants and a unit of a wind-diesel combination is tested with the cascaded controller scheme with a different controller setting for each area. The variation of the load is taken within 1% to 5% of the connected load and robustness analysis is shown by modifying essential factors simultaneously by± 30%. Finally, the proposed scheme of controller and optimization technique is also tested with a 5-equal area thermal system with non-linearities. The simulation results demonstrate the superiority of the proposed controller and algorithm under a dynamically changing load. 展开更多
关键词 Automatic generation control(AGC) cascaded CONTROLLER hybrid improved teaching learning based optimization-differential evolution(hITLBO-DE) algorithm INTEGRAL of SQUARE time multiplied by SQUARE error(ISTSE)
下载PDF
Short-term power generation scheduling rules for cascade hydropower stations based on hybrid algorithm 被引量:2
8
作者 Wei XIE Chang-ming JI +1 位作者 Zi-jun YANG Xiao-xing ZHANG 《Water Science and Engineering》 EI CAS 2012年第1期46-58,共13页
Power generation dispatching is a large complex system problem with multi-dimensional and nonlinear characteristics. A mathematical model was established based on the principle of reservoir operation. A large quantity... Power generation dispatching is a large complex system problem with multi-dimensional and nonlinear characteristics. A mathematical model was established based on the principle of reservoir operation. A large quantity of optimal scheduling processes were obtained by calculating the daily runoff process within three typical years, and a large number of simulated daily runoff processes were obtained using the progressive optimality algorithm (POA) in combination with the genetic algorithm (GA). After analyzing the optimal scheduling processes, the corresponding scheduling rules were determined, and the practical formulas were obtained. These rules can make full use of the rolling runoff forecast and carry out the rolling scheduling. Compared with the optimized results, the maximum relative difference of the annual power generation obtained by the scheduling rules is no more than 1%. The effectiveness and practical applicability of the scheduling rules are demonstrated by a case study. This study provides a new perspective for formulating the rules of power generation dispatching. 展开更多
关键词 scheduling rule short-time power generation dispatching hybrid algorithm cascade hydropower station
下载PDF
Neural Network and Fuzzy Control Based 11-Level Cascaded Inverter Operation
9
作者 Buddhadeva Sahoo Sangram Keshari Routray +1 位作者 Pravat Kumar Rout Mohammed M.Alhaider 《Computers, Materials & Continua》 SCIE EI 2022年第2期2319-2346,共28页
This paper presents a combined control and modulation technique to enhance the power quality(PQ)and power reliability(PR)of a hybrid energy system(HES)through a single-phase 11-level cascaded H-bridge inverter(11-CHBI... This paper presents a combined control and modulation technique to enhance the power quality(PQ)and power reliability(PR)of a hybrid energy system(HES)through a single-phase 11-level cascaded H-bridge inverter(11-CHBI).The controller and inverter specifically regulate the HES and meet the load demand.To track optimum power,a Modified Perturb and Observe(MP&O)technique is used for HES.Ultra-capacitor(UCAP)based energy storage device and a novel current control strategy are proposed to provide additional active power support during both voltage sag and swell conditions.For an improved PQ and PR,a two-way current control strategy such as the main controller(MC)and auxiliary controller(AC)is suggested for the 11-CHBI operation.MC is used to regulate the active current component through the fuzzy controller(FC),and AC is used to regulate the dc-link voltage of CHBI through a neural network-based PI controller(ANN-PI).By tracking the reference signals fromMC and AC,a novel hybrid pulse widthmodulation(HPWM)technique is proposed for the 11-CHBI operation.To justify and analyze the MATLAB/Simulink software-based designed model,the robust controller performance is tested through numerous steady-state and dynamic state case studies. 展开更多
关键词 ULTRA-CAPACITOR 11-level cascaded h-bridge inverter hybrid energy system modified perturb and observer neural network-based PI fuzzy controller
下载PDF
Simplified Cluster Voltage Balancing Control Based on Zero-sequence Voltage Injection for Star-connected Cascaded H-bridge STATCOM
10
作者 Kai Hu Guoliang Zhao +4 位作者 Daorong Lu Zhengang Lu Nianwen Xiang Shulai Wang Jintian Lin 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第5期2255-2264,共10页
The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-... The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-wire system.However,as the zero-sequence voltage is expressed in trigonometric form,traditional control methods involve many complicated operations,such as the square-root,trigonometric operations,and inverse tangent operations.To simplify cluster voltage balancing control,this paper converts the zero-sequence voltage to the dq frame in a DC representation by introducing a virtually orthogonal variable,and the DC components of the zero-sequence voltage in the dq frame are regulated linearly by proportional integral regulators,rather than being calculated from uneven active powers in traditional controls.This removes all complicated operations.Finally,this paper presents simulation and experimental results for a 400 V±7.5 kvar star-connected STATCOM,in balanced and unbalanced scenarios,thereby verifying the effectiveness of the proposed control. 展开更多
关键词 Cluster DC voltage balancing control DC representation of zero-sequence voltage star-connected cascaded h-bridge STATCOM zero-sequence voltage injection
原文传递
Capacitor Pattern H-Bridge Multilevel Inverter (CPHMLI) Using Phase Diposition Pulse Width Modulation for Grid Applications
11
作者 M. S. Saravanan R. Jeyabharath 《Circuits and Systems》 2016年第10期3310-3319,共10页
This work presents an implementation of an innovative single phase multilevel inverter using capacitors with reduced switches. The proposed Capacitor pattern H-bridge Multilevel Inverter (CPHMLI) topology consists of ... This work presents an implementation of an innovative single phase multilevel inverter using capacitors with reduced switches. The proposed Capacitor pattern H-bridge Multilevel Inverter (CPHMLI) topology consists of a proper number of Capacitor connected with switches and power sources. The advanced switching control supplied by Pulse Width Modulation (PDPWM) to attain mixed staircase switching state. The charging and discharging mode are achieved by calculating the voltage error at the load. Furthermore, to accomplish the higher voltage levels at the output with less number of semiconductors switches and simple commutation designed using CPHMLI topology. To prove the performance and effectiveness of the proposed approach, a set of experiments performed under various load conditions using MATLAB tool. 展开更多
关键词 Switched Capacitor Multilevel Inverter Phase Diposition Pulse Width Modulation Capacitor Pattern Based Multilevel Inverter Total Harmonic Distortion cascaded h-bridge 17-Level Inverter
下载PDF
Traveling Wave Characteristics Based Pilot Protection Scheme for Hybrid Cascaded HVDC Transmission Line
12
作者 Dalin Mu Sheng Lin Xiaopeng Li 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第3期971-980,共10页
The hybrid cascaded high-voltage direct current(HVDC)transmission system has various operation modes,and some operation modes have sharply increasing requirements for protection rapidity,while the traditional pilot di... The hybrid cascaded high-voltage direct current(HVDC)transmission system has various operation modes,and some operation modes have sharply increasing requirements for protection rapidity,while the traditional pilot differential protection(PDP)has poor rapidity,and even refuses to operate when faults occur on the DC line.Therefore,a novel pilot protection scheme based on traveling wave characteristics is proposed.First,the adaptability of the traditional PDP applied in engineering is analyzed for different operation modes.Then,the expressions of the forward traveling wave(FTW)and backward traveling wave(BTW)on the rectifier side and the inverter side are derived for different fault locations.From the theoretical derivation,the difference between the BTW and FTW on the rectifier side is less than zero,and the same is true on the inverter side.However,in the event of an external fault of DC line,the difference between the BTW and FTW at nearfault terminal protection installation point is greater than zero.Therefore,by summing over the product of the difference between BTW and FTW of the rectifier side and that of the inverter side,the fault identification criterion is constructed.The simulation results show that the proposed pilot protection scheme can quickly and reliably identify the short-circuit faults of DC line in different operation modes. 展开更多
关键词 hybrid cascaded high-voltage direct current(HVDC)transmission system DC line operation mode pilot protection
原文传递
Evaluation of 1.2 kV SiC MOSFETs in Multilevel Cascaded H-bridge Three-phase Inverter for Medium-voltage Grid Applications 被引量:6
13
作者 Haider Mhiesan Janviere Umuhoza +2 位作者 Kenneth Mordi Chris Farnell H.Alan Mantooth 《Chinese Journal of Electrical Engineering》 CSCD 2019年第2期1-13,共13页
A study is conducted to evaluate 1.2 kV silicon-carbide(SiC)MOSFETs in a cascaded H-bridge(CHB)three-phase inverter for medium-voltage applications.The main purpose of this topology is to remove the need for a bulky 6... A study is conducted to evaluate 1.2 kV silicon-carbide(SiC)MOSFETs in a cascaded H-bridge(CHB)three-phase inverter for medium-voltage applications.The main purpose of this topology is to remove the need for a bulky 60 Hz transformer normally used to step up the output signal of a voltage source inverter to a medium-voltage level.Using SiC devices(1.2-6.5 kV SiC MOSFETs)which have a high breakdown voltage,enables the system to meet and withstand the medium-voltage stress using only a minimal number of cascaded modules.The SiC-based power electronics when used in the presented topology considerably reduce the complexity usually encountered when Si devices are used to meet the medium-voltage level and power scalability.Simulation and preliminary experimental results on a low-voltage prototype verifies the nine-level CHB topology presented in this study. 展开更多
关键词 SiC switching devices cascaded h-bridge inverter medium voltage AC grid energy storage
原文传递
Parameters matching and optimization of parallel hybrid electric vehicle powertrain 被引量:7
14
作者 陈勇 Chen Xiaokai Lin Yi 《High Technology Letters》 EI CAS 2010年第1期34-38,共5页
Aiming at the development of parallel hybrid electric vehicle (PHEV) powertrain, parameter matching and optimization are presented, According to the performance of PHEV, the optimization range of engine, motor, driv... Aiming at the development of parallel hybrid electric vehicle (PHEV) powertrain, parameter matching and optimization are presented, According to the performance of PHEV, the optimization range of engine, motor, driveline gear ratio and battery parameters are determined. And then a two-level optimization problem is formulated based on analytical target cascading (ATC). At the system level, the optimization of the whole vehicle fuel economy is carried out, while the tractive performance is defined as the constraints. The optimized parameters are cascaded to the subsystem as the optimization targets. At the subsystem level, the final drive and transmission design are optimized to make the ratios as close to the targets as possible. The optimization result shows that the fuel economy had improved significantly, while the tractive performance maintains the former level. 展开更多
关键词 parallel hybrid electric vehicle (PHEV) parameters matching OPTIMIZATION analytical target cascading (ATC) POWERTRAIN
下载PDF
Neutrophil-mimetic hybrid liposome with ROS cascade amplification for synergistic ferroptosis-photodynamic therapy of breast cancer
15
作者 Jiaxin Li Jiaxin Li +8 位作者 Jiao He Xuan He Dong Chen Ziyan Dong Lin Xiong Wenjing Bai Man Li Rong Guo Qin He 《Nano Research》 SCIE EI 2024年第11期9932-9941,共10页
Photodynamic therapy (PDT) and ferroptosis therapy have received extensive attention in breast cancer treatment. PDT induced apoptosis of tumor cells by producing a large amount of reactive oxygen species (ROS) under ... Photodynamic therapy (PDT) and ferroptosis therapy have received extensive attention in breast cancer treatment. PDT induced apoptosis of tumor cells by producing a large amount of reactive oxygen species (ROS) under laser irradiation. Differently, ferroptosis therapy exerts its antitumor effect by inducing excessive accumulation of lipid peroxides on tumor cell membranes. Based on that, ROS produced by PDT may promote ferroptosis in tumor cells, and ferroptosis therapy is expected eliminate apoptosis-resistant tumor cells. Therefore, a synergistic ferroptosis-photodynamic therapy will be more effective and more potential in breast cancer treatment. Considering PDT has the characteristic of producing ROS, and neutrophil has a natural tendency to ROS, a neutrophil-mimetic hybrid liposome (CR-NML) was designed for co-delivery of the photosensitizer Ce6 and the ferroptosis inducer RSL3. CR-NML targeted tumor through the ROS tendency of neutrophil and the enhanced permeability and retention (EPR) effect of liposome, then induced both apoptosis and ferroptosis in tumor cells, which increased ROS level and finally realized ROS cascade amplification. The synergistic ferroptosis-photodynamic therapy demonstrated significant therapeutic efficacy in 4T1 tumor bearing mice, which provided a promising strategy for breast cancer treatment. 展开更多
关键词 neutrophil-mimetic hybrid liposome reactive oxygen species(ROS)cascade amplification photodynamic therapy ferroptosis therapy breast cancer
原文传递
AERODYNAMIC DESIGN METHOD OF CASCADEPROFILES BASED ON LOAD AND BLADETHICKNESS DISTRIBUTION
16
作者 姚征 刘高联 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2003年第8期886-892,共7页
A cascade profile design method was proposed using the aerodynamic load and blade thickness distribution as the design constraints, which were correspondent to the demands from the aerodynamic characteristics and the ... A cascade profile design method was proposed using the aerodynamic load and blade thickness distribution as the design constraints, which were correspondent to the demands from the aerodynamic characteristics and the blade strength. These constraints,together with all the other boundary conditions , were involved in the stationary conditions ofa variational principle , in which the angle-function was employed as the unknown function.The angle-function ( i. e. , the circumferential angular coordinate) was defined in the image plane composed of the stream function coordinate ( circumferential direction ) and streamline coordinate. The solution domain, i.e., the blade-to-blade passage, was transformed into a square in the image plane, while the blade contour was projected to a straight line ; thus, the difficulty of the unknown blade geometry was avoided. The finite element method was employed to establish the calculation code. Applications show that this method can satisfy the design requests on the blade profile from both aerodynamic and strength respects. In addition, quite different from the most inverse-problem approaches that often encounter difficulties in the convergence of iteration, the present method shows a stable and fast convergence tendency. This will be significant for engineering applications. 展开更多
关键词 cascade design hybrid problem variational principle finite element method
下载PDF
Finite-time robust control for transformerless H-bridge cascaded STATCOM with star configuration
17
作者 Xingyu Lv Bangjun Lei Shumin Fei 《Journal of Control and Decision》 EI 2021年第2期106-115,共10页
This article presents a finite-time robust control(FTRC)of a transformerless STATCOM based on a cascaded multilevel H-bridge converter(CMHC)with star configuration.The FTRC is first proposed for the current loop contr... This article presents a finite-time robust control(FTRC)of a transformerless STATCOM based on a cascaded multilevel H-bridge converter(CMHC)with star configuration.The FTRC is first proposed for the current loop control of a CMHC-based transformerless STATCOM by using the finite time robust control theory.Taking the parameters,perturbations and external disturbances into account and using coordinate transformation method,the nonlinear dynamic model of the CMHC-based transformerless STATCOM is transformed into a standard nonlinear port-controlled dissipative Hamiltonian(PCDH)structure.Based on the PCDH structure,an FTRC is designed for the CMHC-based transformerless STATCOM to improve the transient stability and oscillation damping of power system.Finally,the simulation results demonstrate that the FTRC has better dynamic performance and strong robustness in comparison with the passivity-based control of the CMHC-based transformerless STATCOM. 展开更多
关键词 cascaded h-bridge converter transformerless STATCOM finite time robust control oscillations damping transient stability
原文传递
混合级联特高压直流输电系统逆变站保护功能及闭锁策略设计
18
作者 唐俊 赵文强 +3 位作者 姜崇学 卢宇 卢亚军 徐莹 《浙江电力》 2024年第10期103-113,共11页
针对混合级联特高压直流输电系统的逆变站,基于其一次拓扑结构,按照保护无死区、故障易定位的原则,结合测量互感器的安装位置,提出了保护的分区建议和配置方案。根据逆变站故障发生的位置及严重程度,以快速切除故障、减少停运范围为目标... 针对混合级联特高压直流输电系统的逆变站,基于其一次拓扑结构,按照保护无死区、故障易定位的原则,结合测量互感器的安装位置,提出了保护的分区建议和配置方案。根据逆变站故障发生的位置及严重程度,以快速切除故障、减少停运范围为目标,提出包括LCC(电网换相换流器)闭锁、单MMC(模块化多电平换流器)闭锁、MMC整体闭锁、顺序极闭锁和分步极闭锁的分级闭锁策略。以白鹤滩-江苏混合级联特高压直流输电工程实际的控制保护装置和按照工程成套参数建立的RTDS(实时仿真系统)模型组建了实时闭环仿真系统,通过仿真验证了所提保护方案和闭锁策略的可行性和有效性。 展开更多
关键词 混合级联系统 特高压直流输电 保护配置 闭锁策略 电网换相换流器 模块化多电平换流器
下载PDF
低电容CHB型混合动力中压电机调速系统
19
作者 孙孝峰 黄晨阳 +4 位作者 滕甲训 潘禹卓 齐磊 赵巍 李昕 《中国电机工程学报》 EI CSCD 北大核心 2024年第20期8233-8247,I0026,共16页
针对氢燃料电池大功率电机驱动系统,提出一种以燃料电池为主动力源的轻量化级联H桥(cascadedH-bridge,CHB)型混合动力中压电机调速系统。所提系统由燃料电池/蓄电池/超级电容的混合动力源供电,基于四有源桥(quad activebridge,QAB)与CH... 针对氢燃料电池大功率电机驱动系统,提出一种以燃料电池为主动力源的轻量化级联H桥(cascadedH-bridge,CHB)型混合动力中压电机调速系统。所提系统由燃料电池/蓄电池/超级电容的混合动力源供电,基于四有源桥(quad activebridge,QAB)与CHB子模块互联的两级变换器(cascaded H-bridges with quad active bridge,CHB-QAB)作为调速变换器。CHB-QAB通过四绕组高频变压器将各子模块进行内部互联,采用单边同步双边移相调制的策略,使得所有子模块呈现开关电容特性,在不依赖复杂控制的前提下,减小子模块电容的容值,提升系统的功率密度。针对三类动力源,采用基于低通滤波(lowpassfilter,LPF)的能量管理策略,保证电机实际运行过程中的有效功率分配,解决燃料电池对电机动态响应缓慢和燃料饥饿现象等问题。最后通过仿真与实验对所提轻量化电机调速系统进行验证。 展开更多
关键词 混合动力源 级联H桥 低通滤波 电机调速 轻量化
下载PDF
补偿不平衡负载的HC-SVG相间电压平衡控制与直流电压取值分析
20
作者 杜少通 何金泽 +2 位作者 原亚雷 朱军 李威 《电力系统保护与控制》 EI CSCD 北大核心 2024年第12期33-44,共12页
针对由中点钳位型(neutral-point clamped,NPC)功率单元和H桥级联型(cascade H-bridge,CHB)功率单元构成的混合级联型静止无功发生器(hybrid cascade static var generator,HC-SVG)在补偿不平衡负载时产生的CHB功率单元相间电压失衡问题... 针对由中点钳位型(neutral-point clamped,NPC)功率单元和H桥级联型(cascade H-bridge,CHB)功率单元构成的混合级联型静止无功发生器(hybrid cascade static var generator,HC-SVG)在补偿不平衡负载时产生的CHB功率单元相间电压失衡问题,提出一种基于零序电压前馈的CHB功率单元相间电压平衡控制方法,并对零序电压注入后HC-SVG直流侧电压取值进行分析。首先,分析CHB功率单元承担基波电压分量与HC-SVG输出基波电压的关系。推导HC-SVG补偿不平衡负载时CHB功率单元相间电压平衡所需的零序电压,建立零序电压前馈控制。其次,基于零序电压与补偿电流的解析关系,讨论补偿电流不平衡度与HC-SVG直流侧电压取值之间的约束关系。以6 kV/3 Mvar装置为算例,进行直流侧电压的取值分析。并与星接CHB-SVG进行对比,揭示补偿不平衡负载时HC-SVG所需直流电压低的特点。仿真验证了相间电压平衡控制与直流电压取值分析的有效性。 展开更多
关键词 混合级联 静止无功发生器 不平衡负载 零序电压 直流侧电压取值
下载PDF
上一页 1 2 15 下一页 到第
使用帮助 返回顶部