期刊文献+
共找到200篇文章
< 1 2 10 >
每页显示 20 50 100
Mechanical Properties of Layered Steel Fiber and Hybrid Fiber Reinforced Concrete 被引量:5
1
作者 卢哲安 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2008年第5期733-736,共4页
To explore a new structure form of fiber reinforced concrete, namely, the layered steel fiber and layered hybrid fiber reinforced concrete (LSFRC and LHFRC), the mechanical properties of LSFRC and LHFRC, such as com... To explore a new structure form of fiber reinforced concrete, namely, the layered steel fiber and layered hybrid fiber reinforced concrete (LSFRC and LHFRC), the mechanical properties of LSFRC and LHFRC, such as compressive strength, tensile strength, flexural strength, fatigue and durability were focused on. The experimental results show that LSFRC and LHFRC can improve the flexural strength of concrete by 20%-50%. In the aspect of improving the flexural strength of concrete, adulterant rate has more obvious effect than length/diameter ratio. Double logarithmic fatigue equation considered liveability was founded. The impermeability of LHFRC is superior to LSFRC and plain concrete (C). However, the porosity of LHFRC is lower than LSFRC and C. The shrinkage of LHFRC at every age is obviously lower than C. The antifreeze durability of LHFRC is also better than C. 展开更多
关键词 layered steel fiber reinforced concrete mechanical properties layer hybrid fiber reinforced concrete
下载PDF
Mechanical Properties of Layered Hybrid Fiber Reinforced Concrete 被引量:3
2
作者 袁海庆 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2003年第2期68-70,共3页
To improve the mechanical properties of concrete,Layered Hybrid Fiber Reinforced Concrete (LHFRC) was developed in this paper.Through comparative tests,the effects of layered hybrid fibers on a series of mechanical pr... To improve the mechanical properties of concrete,Layered Hybrid Fiber Reinforced Concrete (LHFRC) was developed in this paper.Through comparative tests,the effects of layered hybrid fibers on a series of mechanical properties of concrete were discussed.The mechanical properties include compressive strength,tensile strength,flexural strength,compressive stress-strain relationship,flexural toughness and cracking resistance of concrete.The testing results and analysis demonstrate that layered hybrid fibers can significantly improve the flexural strength,toughness and cracking resistance of concrete while the cost of concrete increases slightly. 展开更多
关键词 layered hybrid fiber reinforced concrete STRENGTH flexural toughness
下载PDF
Flexural Fatigue Behavior of Layered Hybrid Fiber Reinforced Concrete 被引量:1
3
作者 王佶 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2007年第3期560-563,共4页
In order to obtain the fatigue life of layered hybrid fiber reinforced concrete (LHFRC) at different stress levels, flexural fatigue tests were carried out on specimens. The relation between fatigue lives and stress... In order to obtain the fatigue life of layered hybrid fiber reinforced concrete (LHFRC) at different stress levels, flexural fatigue tests were carried out on specimens. The relation between fatigue lives and stress levels was simulated using the two-parameter Weibull distribution. Furthermore, both single- logarithmic and double-logarithmic regressive equations of various reliabilities were derived. It is evident that LHFRC gets the advantage of longer fatigue life over common concrete. 展开更多
关键词 layered hybrid fiber reinforced concrete(Lhfrc flexural intensity fatigue test fatigue equationion
下载PDF
Experimental Investigation on the Mechanical Properties of Natural Fiber Reinforced Concrete 被引量:2
4
作者 Ismail Shah Jing Li +2 位作者 Shengyuan Yang Yubo Zhang Aftab Anwar 《Journal of Renewable Materials》 SCIE EI 2022年第5期1307-1320,共14页
Recently,addition of various natural fibers to high strength concrete has aroused great interest in the field of building materials.This is because natural fibers are much cheaper and locally available,as compare to s... Recently,addition of various natural fibers to high strength concrete has aroused great interest in the field of building materials.This is because natural fibers are much cheaper and locally available,as compare to synthetic fibers.Keeping in view,this current research conducted mainly focuses on the static properties of hybridized(sisal/coir),sisal and coir fiber-reinforced concrete.Two types of natural fibers sisal and coir were used in the experiment with different lengths of 10,20 and 30 mm and various natural fiber concentrations of 0.5%,1.0%,and 1.5%by mass of cement,to investigate the static properties of sisal fiber reinforced concrete(SFRC),coir fiber reinforced concrete(CFRC)and hybrid fiber reinforced concrete(HFRC).The results indicate that HFRC has increased the compressive strength up to 35.98%with the length of 20 mm and with 0.5%concentration,while the CFRC and SFRC with the length of 10 mm and with 1%concentration have increased the compressive strength up to 33.94%and 24.86%,respectively.On another hand,the split tensile strength was increased by HFRC with the length of 20 mm and with 1%concentration,CFRC with the length of 10 mm and with 1.5%concentration,and SFRC with the length of 30 mm and with 1%concentration have increased up to 25.48%,24.56%and 11.80%,respectively,while the HFRC with the length of 20 mm and with 0.5%concentration has increased the compressive strength of concrete but has decreased the split tensile strength up to 2.28%compared to PC.Overall,using the HFRC with the length of 20 mm and with 1%concentration provide the maximum output in terms of split tensile strength. 展开更多
关键词 Sisal fiber reinforced concrete coir fiber reinforced concrete hybrid fibers compressive and tensile strength
下载PDF
Numerical simulation and experimental study on electrothermal properties of carbon/glass fiber hybrid textile reinforced concrete 被引量:8
5
作者 XU ShiLang YU WenTing SONG ShiDe 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第9期2421-2428,共8页
Carbon/glass fiber hybrid textile reinforced concrete is a relatively new composite material with good mechanical capacity and excellent electrical conductivity.Both small-scale slab heating experiments and numerical ... Carbon/glass fiber hybrid textile reinforced concrete is a relatively new composite material with good mechanical capacity and excellent electrical conductivity.Both small-scale slab heating experiments and numerical simulation are presented in this paper.Temperature variation curves obtained during heating indicate the effects of environmental temperature,heat-conducting layer thickness and electric heating power.Comparison of temperature rising between the situations with and without thermal isolation layer is given as well.The results indicate that the textile can form a good conductive heating network and generate enough heat to raise the temperature in the concrete when connected to a power supply,while the resistance of the slab remains stable during the heating.Numerical results are in good accordance with the experiments.Real time snow-melting experiment was conducted to verify the feasibility of deicing.The electrothermal properties of textile can be utilized for deicing and snow melting in a safe,environmentally friendly and efficient way. 展开更多
关键词 钢筋混凝土 加热实验 数值模拟 电热性能 玻璃纤维 碳纤维 纺织 混合
原文传递
An artificial neural network model on tensile behavior of hybrid steel-PVA fiber reinforced concrete containing fly ash and slag power 被引量:1
6
作者 Fangvu LIU Wenqi DING +1 位作者 Yafei QIAO Linbing WANG 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2020年第6期1299-1315,共17页
The tensile behavior of hybrid fiber reinforced concrete(HFRC)is important to the design of HFRC and HFRC structure.This study used an artificial neural network(ANN)model to describe the tensile behavior of HFRC.This ... The tensile behavior of hybrid fiber reinforced concrete(HFRC)is important to the design of HFRC and HFRC structure.This study used an artificial neural network(ANN)model to describe the tensile behavior of HFRC.This ANN model can describe well the tensile stress-strain curve of HFRC with the consideration of 23 features of HFRC.In the model,three methods to process output features(no-processed,mid-processed,and processed)are discussed and the mid-processed method is recommended to achieve a better reproduction of the experimental data.This means the strain should be normalized while the stress doesn’t need normalization.To prepare the database of the model,both many direct tensile test results and the relevant literature data are collected.Moreover,a traditional equation-based model is also established and compared with the ANN model.The results show that the ANN model has a better prediction than the equation-based model in terms of the tensile stress-strain curve,tensile strength,and strain corresponding to tensile strength of HFRC.Finally,the sensitivity analysis of the ANN model is also performed to analyze the contribution of each input feature to the tensile strength and strain corresponding to tensile strength.The mechanical properties of plain concrete make the main contribution to the tensile strength and strain corresponding to tensile strength,while steel fibers tend to make more contributions to these two items than PVA fibers. 展开更多
关键词 artificial neural network hybrid fiber reinforced concrete tensile behavior sensitivity analysis STRESS-STRAIN
原文传递
钢-PVA纤维混凝土预制连梁抗震性能试验研究
7
作者 于婧 贾会芳 张辉 《西安建筑科技大学学报(自然科学版)》 北大核心 2024年第1期57-64,共8页
为研究钢-聚乙烯醇混杂纤维混凝土(Steel-Polyvinyl Alcohol Hybird Fiber Concrete,简称SPHFC)预制连梁的抗震性能,对1个普通混凝土(RC)预制连梁试件和3个SPHFC预制连梁试件进行低周往复加载试验,分析预制连梁的破坏过程、破坏形态、... 为研究钢-聚乙烯醇混杂纤维混凝土(Steel-Polyvinyl Alcohol Hybird Fiber Concrete,简称SPHFC)预制连梁的抗震性能,对1个普通混凝土(RC)预制连梁试件和3个SPHFC预制连梁试件进行低周往复加载试验,分析预制连梁的破坏过程、破坏形态、滞回性能、刚度及耗能能力等抗震指标,研究连梁基体材料和截面宽度对其抗震性能的影响,阐明了SPHFC预制连梁的破坏机理.结果表明:RC预制连梁破坏时混凝土剥落现象严重,最终表现为剪切型破坏;SPHFC预制连梁破坏时几乎无混凝土剥落现象,充分发挥了纤维混凝土多裂缝开展的特点,最终发生弯剪型破坏;SPHFC预制连梁的承载力、延性、刚度和耗能能力均远高于RC预制连梁;分别增大SPHFC预制连梁基体强度或截面宽度,连梁承载力提高,延性和耗能能力略有降低.本文提出的新型SPHFC预制连梁各项抗震指标均显著优于普通RC预制连梁,且制作简便,轻质高强,便于预制吊装,可在装配式结构中推广应用. 展开更多
关键词 钢-PVA混杂纤维混凝土(SPHFC) 拟静力试验 小跨高比预制连梁 抗震性能
下载PDF
火灾后RC及HFRC隧道管片破坏试验研究 被引量:9
8
作者 沈奕 闫治国 沈安迪 《地下空间与工程学报》 CSCD 北大核心 2017年第2期531-537,共7页
为研究火灾后盾构隧道管片的破坏模式,借助火灾试验手段,对钢筋混凝土(RC)及混杂纤维混凝土(HFRC)两种类型的管片在不同工况下的破坏模式进行了研究。根据试验结果,受正弯矩单向加载的钢筋混凝土管片的极限承载力和变形性能均大于混杂... 为研究火灾后盾构隧道管片的破坏模式,借助火灾试验手段,对钢筋混凝土(RC)及混杂纤维混凝土(HFRC)两种类型的管片在不同工况下的破坏模式进行了研究。根据试验结果,受正弯矩单向加载的钢筋混凝土管片的极限承载力和变形性能均大于混杂纤维混凝土管片。在该工况下,钢筋混凝土管片的破坏模式为弯曲破坏,混杂纤维混凝土管片的破坏模式则为弯曲剪切破坏。而在受负弯矩双向加载的工况下,钢筋混凝土管片为剪切破坏模式,而混杂纤维混凝土管片为受弯破坏模式。由于破坏模式的差别,导致混杂纤维混凝土管片的变形发挥要优于钢筋混凝土管片。基于以上结论,笔者对盾构隧道管片的抗火设计提出了一些相关建议。 展开更多
关键词 隧道火灾 钢筋混凝土 混杂纤维混凝土 盾构隧道管片
下载PDF
冻融疲劳作用下LHFRC损伤演变规律 被引量:4
9
作者 贺东青 卢哲安 +1 位作者 任志刚 张宇 《武汉理工大学学报》 EI CAS CSCD 北大核心 2007年第7期92-94,129,共4页
为了研究层布式混杂纤维混凝土(LHFRC)在冻融疲劳作用下的损伤演变规律,提出了混凝土抗冻劣化的损伤演变数学模型,同时进行了普通混凝土(OC)与层布式混杂纤维混凝土的冻融试验,并在试验的基础上,回归出它们的冻融损伤演变方程。结果表明... 为了研究层布式混杂纤维混凝土(LHFRC)在冻融疲劳作用下的损伤演变规律,提出了混凝土抗冻劣化的损伤演变数学模型,同时进行了普通混凝土(OC)与层布式混杂纤维混凝土的冻融试验,并在试验的基础上,回归出它们的冻融损伤演变方程。结果表明,LHFRC和OC的初劣点值相同,且在劣化初始阶段具体相同的损伤演变方程;在劣化扩展阶段,LHFRC和OC均具有幂函数形式的损伤演变方程,但LHFRF损伤变量小于同期的OC,钢纤维和聚丙烯纤维有效地抑制了其内部损伤发展。 展开更多
关键词 损伤演变 层布式混杂纤维混凝土 冻融试验
下载PDF
GFRP筋混杂纤维混凝土隧道管片力学性能研究
10
作者 陈晟晟 周春恒 章子华 《工程力学》 EI CSCD 北大核心 2024年第S01期238-244,252,共8页
为研究GFRP筋混杂纤维混凝土隧道管片的力学性能,进行了三个不同GFRP筋配筋率的钢-聚丙烯纤维混凝土管片静力受弯试验,获得了试件的破坏形态、承载力及裂缝扩展模式。考虑GFRP筋与混杂纤维混凝土的界面黏结,采用ABAQUS建立了GFRP筋混杂... 为研究GFRP筋混杂纤维混凝土隧道管片的力学性能,进行了三个不同GFRP筋配筋率的钢-聚丙烯纤维混凝土管片静力受弯试验,获得了试件的破坏形态、承载力及裂缝扩展模式。考虑GFRP筋与混杂纤维混凝土的界面黏结,采用ABAQUS建立了GFRP筋混杂纤维混凝土管片的有限元模型,分析了不同混杂纤维掺量和配筋率对管片受弯承载力的影响。研究结果表明:GFRP筋混杂纤维混凝土管片的破坏主要是由跨中主裂缝贯穿和GFRP筋材断裂导致;在纤维体积掺量不变的情况下,提高纵向受拉GFRP筋的配筋率,可以有效提高管片的受弯承载力;在数值计算中,考虑GFRP筋与混杂纤维混凝土的界面黏结滑移的有限元模型能更准确地模拟试件的开裂荷载、极限荷载和弯曲刚度;在承载力不变的情况下,增加混杂纤维的体积分数能有效减少管片的配筋率,并且提高管片的抗变形能力;通过回归分析,提出了纤维掺量与配筋率关系的计算式,理论计算结果与数值结果符合较好。 展开更多
关键词 GFRP筋 混杂纤维混凝土 配筋率 静力受弯试验 界面黏结 有限元模型
下载PDF
足尺寸GFRP筋HFRC柱的轴压性能与理论研究 被引量:1
11
作者 邓宗才 贾鹏星 《北京工业大学学报》 CAS CSCD 北大核心 2016年第12期1873-1879,共7页
为了研究玻璃纤维增强聚合物(glass fiber reinforced polymer,GFRP)筋混杂纤维混凝土(hybrid fiber reinforced concrete,HFRC)柱的轴压性能,进行了5个GFRP筋HFRC柱和1个未配筋HFRC柱的轴压试验,分析了GFRP箍筋间距和纵筋配筋率对GFRP... 为了研究玻璃纤维增强聚合物(glass fiber reinforced polymer,GFRP)筋混杂纤维混凝土(hybrid fiber reinforced concrete,HFRC)柱的轴压性能,进行了5个GFRP筋HFRC柱和1个未配筋HFRC柱的轴压试验,分析了GFRP箍筋间距和纵筋配筋率对GFRP筋HFRC柱轴压性能的影响规律.结果表明:提高GFRP纵筋配筋率可以提高试件的承载力,箍筋间距小的试件的延性明显高于箍筋间距大的试件.根据试验数据回归出了GFRP筋HFRC柱峰值应力、峰值应变以及承载力的计算公式. 展开更多
关键词 GFRP筋 混杂纤维混凝土 轴压性能 承载力 变形
下载PDF
非晶合金纤维和钢纤维单/混掺增强混凝土开裂及断裂性能研究
12
作者 乔险涛 喻鹏 +3 位作者 陈喜健 周佳乐 张连杰 李健朋 《硅酸盐通报》 CAS 北大核心 2024年第6期2137-2148,共12页
为探索纤维混凝土抗裂性能,本文研究了不同类型纤维(平直型钢纤维、平直型非晶合金纤维、钢纤维+非晶合金纤维)和不同纤维体积掺量(1.0%,1.5%和2.0%)混凝土的早期开裂性能和硬化后的断裂性能。首先通过平板法试验并借助数字图像对混凝... 为探索纤维混凝土抗裂性能,本文研究了不同类型纤维(平直型钢纤维、平直型非晶合金纤维、钢纤维+非晶合金纤维)和不同纤维体积掺量(1.0%,1.5%和2.0%)混凝土的早期开裂性能和硬化后的断裂性能。首先通过平板法试验并借助数字图像对混凝土的早期裂缝特征进行量化分析,评估了纤维混凝土的早期开裂性能;再通过带切口棱柱体试件的三点弯曲试验,基于双K断裂参数,分析并评估了混凝土硬化后的断裂性能。结果表明,钢纤维单掺和混掺纤维混凝土的早期抗裂性能最好;纤维掺量由1.0%增加至2.0%时,钢纤维、合金纤维和混掺纤维混凝土失稳韧度分别增加了58.9%、44.3%和55.5%,且掺量为2.0%的混掺混凝土断裂能是普通混凝土的11.8倍。钢纤维和非晶合金纤维可在混凝土硬化过程的不同时期发挥协同作用,两种纤维混掺不仅能阻止混凝土早期的塑性开裂,还可有效控制硬化后受拉裂缝的形成和发展,达到分阶段抗裂的目的。综合考虑混凝土的早期开裂性能、硬化后受拉性能以及断裂性能,体积掺量相同情况下混掺纤维混凝土整体性能更优。 展开更多
关键词 纤维混凝土 非晶合金纤维 钢纤维 开裂性能 断裂性能 混掺效应
下载PDF
钢-聚丙烯混杂纤维混凝土冻融损伤试验研究
13
作者 夏冬桃 李天云 +2 位作者 李欣怡 徐乐 任康宁 《混凝土》 CAS 北大核心 2024年第3期136-139,共4页
为研究混杂纤维对高性能混凝土抗冻性能的改善效果,对普通素混凝土、钢纤维混凝土、聚丙烯纤维混凝土和钢-聚丙烯混杂纤维混凝土开展快速冻融循环试验,对冻融作用下试样的各项强度指标进行了检测,并对其质量损失率及相对动弹性模量的变... 为研究混杂纤维对高性能混凝土抗冻性能的改善效果,对普通素混凝土、钢纤维混凝土、聚丙烯纤维混凝土和钢-聚丙烯混杂纤维混凝土开展快速冻融循环试验,对冻融作用下试样的各项强度指标进行了检测,并对其质量损失率及相对动弹性模量的变化规律进行了分析。研究结果表明:掺加纤维有利于改善高性能混凝土的抗冻性能,钢-聚丙烯混杂纤维混凝土的抗冻性能最好,经过200次冻融循环,其质量损失率,相对动弹性模量损失率和强度损失均最低;基于三次多项式建立的纤维混凝土冻融损伤模型比基于指数函数建立的纤维混凝土冻融损伤模型精确度更高,在描述纤维混凝土的冻融损伤程度上适用性较强。 展开更多
关键词 混杂纤维混凝土 冻融损伤机理 损伤变量 冻融损伤模型
下载PDF
富水砂卵石地层水工隧洞衬砌用纤维混凝土性能评价
14
作者 刘贺 《当代化工》 CAS 2024年第5期1068-1072,共5页
为了提高富水地段含砂卵石地层水工隧洞衬砌施工用混凝土材料的耐久性能,将钢纤维和聚丙烯纤维混合作为混杂纤维,分别评价了单一纤维和混杂纤维掺入时对水工隧洞衬砌用混凝土材料的力学性能和抗渗性能的影响。结果表明:在相同的配合比... 为了提高富水地段含砂卵石地层水工隧洞衬砌施工用混凝土材料的耐久性能,将钢纤维和聚丙烯纤维混合作为混杂纤维,分别评价了单一纤维和混杂纤维掺入时对水工隧洞衬砌用混凝土材料的力学性能和抗渗性能的影响。结果表明:在相同的配合比条件下,钢纤维和聚丙烯纤维的掺量越大,混凝土试件的抗折强度相对就越大,抗渗性能越强,而抗压强度则先升高后降低。混杂纤维的掺入能够更好地提升水工隧洞衬砌用混凝土的力学性能和抗渗性能,协同增效作用明显。综合考虑目标工程用混凝土的抗压强度、抗折强度和抗渗性能,推荐混杂纤维中钢纤维的最佳掺量为40 kg·m^(-3),而聚丙烯纤维的最佳掺量为4 kg·m^(-3)。研究结果认为钢纤维和聚丙烯纤维的掺入能够有效改善富水地段含砂卵石地层水工隧洞衬砌用混凝土结构的力学性能和抗渗性能,进而提高水工隧洞工程建设的质量。 展开更多
关键词 富水地段 水工隧洞衬砌 混杂纤维混凝土 力学性能 抗渗性能 团聚 复合材料
下载PDF
单轴循环受拉条件下SP-HFRC力学性能试验研究 被引量:6
15
作者 李建闯 池寅 +1 位作者 李彪 时豫川 《水利与建筑工程学报》 2019年第6期137-145,共9页
通过对21个钢-聚丙烯混杂纤维混凝土(SP-HFRC)试件进行单轴循环受拉试验,研究SP-HFRC在循环受拉条件下的力学行为变化规律。重点分析混杂纤维体积掺量及长径比对应力-应变全曲线、累积塑性应变、刚度退化、应力退化的影响。结果表明:混... 通过对21个钢-聚丙烯混杂纤维混凝土(SP-HFRC)试件进行单轴循环受拉试验,研究SP-HFRC在循环受拉条件下的力学行为变化规律。重点分析混杂纤维体积掺量及长径比对应力-应变全曲线、累积塑性应变、刚度退化、应力退化的影响。结果表明:混杂纤维具有逐级阻裂作用使得SP-HFRC试件呈现明显延性破坏特征;应力-应变全曲线卸载点应变与塑性应变呈线性关系;SP-HFRC刚度退化过程随钢纤维体积掺量和长径比增加而减缓,受聚丙烯纤维体积掺量的影响不明显;纤维对应力退化率的影响不明显。在试验结果和相关文献试验数据的基础上,建立了SP-HFRC单轴循环受拉应力-应变全曲线方程,可用于结构非线性和滞回性能等的分析。 展开更多
关键词 钢-聚丙烯混杂纤维混凝土 循环受拉 应力-应变关系 全曲线方程
下载PDF
玄武岩-聚丙烯纤维混凝土孔隙结构分形维数及力学性能研究 被引量:3
16
作者 赵静 李晓峰 郭力 《复合材料科学与工程》 CAS 北大核心 2023年第8期78-84,共7页
本文基于试验探讨了玄武岩-聚丙烯纤维对混凝土抗压强度和劈裂抗拉强度的影响,并利用光学方法的分形模型计算混凝土孔隙结构的分形维数。试验结果表明:混杂纤维能够提高混凝土的抗压强度和劈裂抗拉强度,当玄武岩纤维(BF)和聚丙烯纤维(PF... 本文基于试验探讨了玄武岩-聚丙烯纤维对混凝土抗压强度和劈裂抗拉强度的影响,并利用光学方法的分形模型计算混凝土孔隙结构的分形维数。试验结果表明:混杂纤维能够提高混凝土的抗压强度和劈裂抗拉强度,当玄武岩纤维(BF)和聚丙烯纤维(PF)含量各为0.05%时,混杂纤维的协同效应最强,抗压强度和劈裂抗拉强度的最大增量分别为5.97%和8.46%,然而当纤维含量过高时,混杂纤维会对试件力学性能产生不利影响。玄武岩-聚丙烯纤维增强混凝土(BPFRC)的孔隙结构表现出明显的分形特征,其分形维数在2.297~2.482范围之间。分形维数与孔隙率和间距系数具有很强的相关性,随着孔隙率的增加而显著降低,随着间距系数的增加而增加。分形维数还与抗压强度和劈裂抗拉强度具有正相关关系。因此,孔隙结构的分形维数可用于评价混凝土的微观孔隙结构,也可以反映孔隙结构的复杂性对混凝土宏观力学性能的影响。 展开更多
关键词 玄武岩纤维 聚丙烯纤维 混杂纤维增强混凝土 力学性能 孔隙结构 分形维数 复合材料
下载PDF
纤维混凝土与旧混凝土黏结劈拉性能
17
作者 童伟光 范银波 《混凝土》 CAS 北大核心 2023年第11期17-19,共3页
在实际工程中,有时候需要对既有混凝土构件进行加固,劈拉强度试验是研究新旧混凝土黏结力学性能的主要试验之一。采用钢纤维混凝土和混杂纤维混凝土与既有混凝土黏结形成标准立方体试件,通过劈拉强度试验,探讨纤维类型、纤维掺量对新旧... 在实际工程中,有时候需要对既有混凝土构件进行加固,劈拉强度试验是研究新旧混凝土黏结力学性能的主要试验之一。采用钢纤维混凝土和混杂纤维混凝土与既有混凝土黏结形成标准立方体试件,通过劈拉强度试验,探讨纤维类型、纤维掺量对新旧混凝土黏结劈拉性能的影响规律。试验结果表明:与普通混凝土相比,采用钢纤维混凝土、钢纤维-合成纤维混杂纤维混凝土加固可显著增加混凝土的劈裂抗拉强度,并且单掺钢纤维混凝土的加固效果优于混杂纤维混凝土。 展开更多
关键词 钢纤维混凝土 混杂纤维混凝土 劈拉强度 既有混凝土加固
下载PDF
基于数字图像相关技术的混杂纤维混凝土动态抗拉性能试验研究
18
作者 杨国梁 毕京九 +3 位作者 董智文 刘依 韩子默 李旭光 《材料导报》 CSCD 北大核心 2023年第21期293-301,共9页
为研究不同纤维混杂比例下的钢-聚丙烯纤维混凝土(SPFRC)的动态抗拉性能,对六组不同纤维混杂比例的混凝土试件进行动态巴西劈裂试验,借助高速摄像仪和数字图像相关技术(DIC)对各组试样动态拉伸断裂过程进行记录和分析。研究表明:试件的... 为研究不同纤维混杂比例下的钢-聚丙烯纤维混凝土(SPFRC)的动态抗拉性能,对六组不同纤维混杂比例的混凝土试件进行动态巴西劈裂试验,借助高速摄像仪和数字图像相关技术(DIC)对各组试样动态拉伸断裂过程进行记录和分析。研究表明:试件的应力时程曲线可以划分为缓速增长、快速增长、稳定、衰减和二次增长五个阶段,相较于素水泥砂浆试件,纤维混凝土试件在应力率二次增长后出现显著的稳定波动平台,纤维混凝土试件的动态拉伸破坏过程具有显著的延性特征;在总纤维掺量保持2%不变的条件下,混杂1%钢纤维与1%聚丙烯纤维的试件具有较优的动态抗拉强度和耗能能力;添加纤维可以减弱试件中心处的拉应变集中现象,混杂1.5%聚丙烯纤维和0.5%钢纤维的试件具有较优的开裂控制能力,平均开裂应变较素水泥砂浆试件提高了2.94倍。 展开更多
关键词 分离式霍普金森杆 数字图像相关技术 动态巴西劈裂试验 混杂纤维混凝土
下载PDF
冲击荷载作用下混杂纤维混凝土能量耗散与破碎分形研究 被引量:4
19
作者 杨露 张文清 《工程爆破》 CSCD 北大核心 2023年第2期25-32,41,共9页
为了研究聚丙烯纤维含量和长径比对混凝土劈裂强度以及分形维数的影响,首先通过在含钢混凝土中添加不同含量和长径比的聚丙烯纤维制作混杂纤维混凝土试样,再利用分离式霍普金森压杆对试样进行高应变率动态劈裂力学试验。实验以相同冲击... 为了研究聚丙烯纤维含量和长径比对混凝土劈裂强度以及分形维数的影响,首先通过在含钢混凝土中添加不同含量和长径比的聚丙烯纤维制作混杂纤维混凝土试样,再利用分离式霍普金森压杆对试样进行高应变率动态劈裂力学试验。实验以相同冲击气压(0.2 MPa)对直径65 mm,高35 mm的10组试件进行测试。研究结果表明:聚丙烯纤维体积掺量为0.05%、0.1%时,长径比在3 000~9 000区间,混杂纤维混凝土的动态劈裂强度与能耗随掺量和长径比的增加有明显上升;在掺量为0.15%时,混杂纤维混凝土的动态劈裂强度与能耗均有所降低。各实验组中混杂纤维混凝土的分形维数均在2.3~2.6之间且小于普通混凝土,说明混杂纤维的添加可使混凝土的韧性、阻裂性能提升。 展开更多
关键词 劈裂强度 分形维数 混杂纤维混凝土 分离式霍普金森压杆
下载PDF
混杂纤维混凝土高温后性能劣化分析与强度预测 被引量:1
20
作者 张劲竹 刘华新 +2 位作者 王家贺 柳根金 王学志 《硅酸盐通报》 CAS 北大核心 2023年第4期1260-1269,共10页
为研究高温对混杂纤维混凝土(HFRC)残余强度与微观结构演变规律的影响,测试了HFRC在不同温度作用后的基本力学性能,借助扫描电子显微镜研究了纤维-水泥浆体界面的微观结构,并利用BP神经网络对HFRC在不同温度作用后的抗压强度进行了预测... 为研究高温对混杂纤维混凝土(HFRC)残余强度与微观结构演变规律的影响,测试了HFRC在不同温度作用后的基本力学性能,借助扫描电子显微镜研究了纤维-水泥浆体界面的微观结构,并利用BP神经网络对HFRC在不同温度作用后的抗压强度进行了预测。结果表明:纤维的混杂效应显著改善了混凝土的耐高温性能,高温后HFRC的抗压强度和劈裂抗拉强度均高于素混凝土;当纤维素纤维和玄武岩纤维体积掺量均为0.15%时,HFRC的抗压强度和劈裂抗拉强度均达到最大值;HFRC内部结构密实,玄武岩纤维填充在孔隙处且与基体的黏结较好,有效抑制了裂缝的扩展;基于神经网络的预测数据与试验数据吻合,BP神经网络较好地预测了高温后HFRC的抗压强度。 展开更多
关键词 混杂纤维混凝土 玄武岩纤维 纤维素纤维 力学性能 微观结构 BP神经网络 强度预测
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部