We propose a novel all fiber Mach-Zehnder interferometer(MZI) based on photonic crystal fiber(PCF) filled with liquid crystal(LC). The interference between the core mode and the cladding modes of a PCF is utiliz...We propose a novel all fiber Mach-Zehnder interferometer(MZI) based on photonic crystal fiber(PCF) filled with liquid crystal(LC). The interference between the core mode and the cladding modes of a PCF is utilized.To excite the cladding modes, a region is formed using fiber fusion splicer. Due to the fact that varying effective index difference between the core region and the LC-filled cladding region can cause different transmission spectra,we mainly study the MZIs with different LC-filled structures and different lengths of LC filling. The measured results demonstrate that quite clear interference spectra can be obtained. Through analysis spatial frequency spectrum and temperature spectrum of two MZIs with different LC-filled structures, we can obtain that the MZI with adjacent two LC-filled holes has clearer interference spectrum and higher temperature sensitivity. Thus we choose this MZI to measure the temperature sensitivity with different lengths of LC filling. When the length of LC filling is 2 cm, the temperature sensitivities can be enlarged to 1.59 nm/C. The interferometer shows a good temperature tunability and sensitivity, which can be a good candidate for a highly tunable optical filtering and temperature sensing applications.展开更多
A detailed theoretical analysis of determining the sum of flexoelectric coefficients in nematic liquid crystals using the capacitance method is given. In the strong anchoring parallel aligned nematic (PAN) and hybri...A detailed theoretical analysis of determining the sum of flexoelectric coefficients in nematic liquid crystals using the capacitance method is given. In the strong anchoring parallel aligned nematic (PAN) and hybrid aligned nematic (HAN) cells, the dependences of the capacitance on the sum of flexoelectric coefficients and the applied voltage are obtained by numerical simulations, and the distributions of the director and the electric potential for different applied voltages and flexoelectric coefficients are also given. Based on this theoretical analysis, we propose an experimental design for measuring the capacitance of a liquid crystal cell using the improved precision LCR meter E4980A (Agilent). Through comparing the experimental data with the simulated results, the sum of flexoeletric coefficients can be determined.展开更多
基金Supported by the National Natural Science Foundation of China under Grant Nos U1531102,61107059,61308052 and U1331114the 111 Project to the Harbin Engineering University under Grant No B13015the Fundamental Research Funds for the Central Universities
文摘We propose a novel all fiber Mach-Zehnder interferometer(MZI) based on photonic crystal fiber(PCF) filled with liquid crystal(LC). The interference between the core mode and the cladding modes of a PCF is utilized.To excite the cladding modes, a region is formed using fiber fusion splicer. Due to the fact that varying effective index difference between the core region and the LC-filled cladding region can cause different transmission spectra,we mainly study the MZIs with different LC-filled structures and different lengths of LC filling. The measured results demonstrate that quite clear interference spectra can be obtained. Through analysis spatial frequency spectrum and temperature spectrum of two MZIs with different LC-filled structures, we can obtain that the MZI with adjacent two LC-filled holes has clearer interference spectrum and higher temperature sensitivity. Thus we choose this MZI to measure the temperature sensitivity with different lengths of LC filling. When the length of LC filling is 2 cm, the temperature sensitivities can be enlarged to 1.59 nm/C. The interferometer shows a good temperature tunability and sensitivity, which can be a good candidate for a highly tunable optical filtering and temperature sensing applications.
基金supported by the National Natural Science Foundation of China(Grant Nos.11274088,11374087,and 11304074)the Natural Science Foundation of Hebei Province,China(Grant No.A2014202123)+2 种基金the Research Project of Hebei Education Department,China(Grant Nos.Z2012061 and QN2014130)the Science and Technology Plan Project of Hebei Province,China(Grant No.134576260)the Key Subject Construction Project of Hebei Province University,China
文摘A detailed theoretical analysis of determining the sum of flexoelectric coefficients in nematic liquid crystals using the capacitance method is given. In the strong anchoring parallel aligned nematic (PAN) and hybrid aligned nematic (HAN) cells, the dependences of the capacitance on the sum of flexoelectric coefficients and the applied voltage are obtained by numerical simulations, and the distributions of the director and the electric potential for different applied voltages and flexoelectric coefficients are also given. Based on this theoretical analysis, we propose an experimental design for measuring the capacitance of a liquid crystal cell using the improved precision LCR meter E4980A (Agilent). Through comparing the experimental data with the simulated results, the sum of flexoeletric coefficients can be determined.