期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Hybrid Power Bank Deployment Model for Energy Supply Coverage Optimization in Industrial Wireless Sensor Network
1
作者 Hang Yang Xunbo Li Witold Pedrycz 《Intelligent Automation & Soft Computing》 SCIE 2023年第8期1531-1551,共21页
Energy supply is one of the most critical challenges of wireless sensor networks(WSNs)and industrial wireless sensor networks(IWSNs).While research on coverage optimization problem(COP)centers on the network’s monito... Energy supply is one of the most critical challenges of wireless sensor networks(WSNs)and industrial wireless sensor networks(IWSNs).While research on coverage optimization problem(COP)centers on the network’s monitoring coverage,this research focuses on the power banks’energy supply coverage.The study of 2-D and 3-D spaces is typical in IWSN,with the realistic environment being more complex with obstacles(i.e.,machines).A 3-D surface is the field of interest(FOI)in this work with the established hybrid power bank deployment model for the energy supply COP optimization of IWSN.The hybrid power bank deployment model is highly adaptive and flexible for new or existing plants already using the IWSN system.The model improves the power supply to a more considerable extent with the least number of power bank deployments.The main innovation in this work is the utilization of a more practical surface model with obstacles and training while improving the convergence speed and quality of the heuristic algorithm.An overall probabilistic coverage rate analysis of every point on the FOI is provided,not limiting the scope to target points or areas.Bresenham’s algorithm is extended from 2-D to 3-D surface to enhance the probabilistic covering model for coverage measurement.A dynamic search strategy(DSS)is proposed to modify the artificial bee colony(ABC)and balance the exploration and exploitation ability for better convergence toward eliminating NP-hard deployment problems.Further,the cellular automata(CA)is utilized to enhance the convergence speed.The case study based on two typical FOI in the IWSN shows that the CA scheme effectively speeds up the optimization process.Comparative experiments are conducted on four benchmark functions to validate the effectiveness of the proposed method.The experimental results show that the proposed algorithm outperforms the ABC and gbest-guided ABC(GABC)algorithms.The results show that the proposed energy coverage optimization method based on the hybrid power bank deployment model generates more accurate results than the results obtained by similar algorithms(i.e.,ABC,GABC).The proposed model is,therefore,effective and efficient for optimization in the IWSN. 展开更多
关键词 Industrial wireless sensor network hybrid power bank deployment model:energy supply coverage optimization artificial bee colony algorithm radio frequency numerical function optimization
下载PDF
Design and Analysis of Sustainable Green Data Center with Hybrid Energy Sources
2
作者 Akibur Rahaman Kazi Nusrat Noor +2 位作者 Tanjin Adnan Abir Sohel Rana Masum Ali 《Journal of Power and Energy Engineering》 2021年第7期76-88,共13页
<span style="font-family:Verdana;">Develop</span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;&qu... <span style="font-family:Verdana;">Develop</span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">ment</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> of renewable energy (RE) and mitigation of carbon dioxide, as the two largest climate action initiatives are the most challenging factors for new generation green data center (GDC). Reduction of conventional electricity consumption as well as cost of electricity (COE) with preferred quality</span></span></span><span><span><span style="font-family:;" "=""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">of service (QoS) has been recognized as the interesting research topic in Information and Communication Technology (ICT) sector. Moreover, it becomes challenging to design a large-scale sustainable GDC with standalone RE supply. This paper gives spotlight on hybrid energy supply solution for the GDC to reduce grid electricity usage and minimum net system cost. The proposed framework includes RE source such as solar photovoltaic, wind turbine and non-renewable energy sources as Disel Generator (DG) and Battery. A hybrid optimization model is designed using HOMER software for cost assessment and energy evaluation to validate the effectiveness of the suggested scheme focusing on eco-friendly implication.</span></span></span> 展开更多
关键词 Green Data Center Renewable Energy SUSTAINABILITY hybrid power supply power Usage Effectiveness
下载PDF
A Smart Charging Algorithm Based on a Fast Charging Station Without Energy Storage System 被引量:2
3
作者 Qifu Cheng Lei Chen +3 位作者 Qiuye Sun Rui Wang Dazhong Ma Dehao Qin 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第4期850-861,共12页
With the growing popularity of electric vehicles(EV),there is an urgent demand to solve the stress placed on grids caused by the irregular and frequent access of EVs.The traditional direct current(DC)fast charging sta... With the growing popularity of electric vehicles(EV),there is an urgent demand to solve the stress placed on grids caused by the irregular and frequent access of EVs.The traditional direct current(DC)fast charging station(FCS)based on a photovoltaic(PV)system can effectively alleviate the stress of the grid and carbon emission,but the high cost of the energy storage system(ESS)and the under utilization of the grid-connected interlinking converters(GIC)are not very well addressed.In this paper,the DC FCS architecture based on a PV system and ESS-free is first proposed and employed to reduce the cost.Moreover,the proposed smart charging algorithm(SCA)can fully coordinate the source/load properties of the grid and EVs to achieve the maximum power output of the PV system and high utilization rate of GICs in the absence of ESS support for FCS.SCA contains a self-regulated algorithm(SRA)for EVs and a grid-regulated algorithm(GRA)for GICs.While the DC bus voltage change caused by power fluctuations does not exceed the set threshold,SRA readjusts the charging power of each EV through the status of the charging(SOC)feedback of the EV,which can ensure the power rebalancing of the FCS.The GRA would participate in the adjustment process once the DC bus voltage is beyond the set threshold range.Under the condition of ensuring the charging power of all EVs,a GRA based on adaptive droop control can improve the utilization rate of GICs.At last,the simulation and experimental results are provided to verify the effectiveness of the proposed SCA. 展开更多
关键词 Energy storage system-free fast charging station hybrid power supply system multiple operation mode smart charging algorithm