期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Review of the Configuration and Transient Stability of Large-scale Renewable Energy Generation through Hybrid DC Transmission
1
作者 Xinshou Tian Yongning Chi +1 位作者 Longxue Li Hongzhi Liu 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期115-126,共12页
Based on the complementary advantages of Line Commutated Converter(LCC)and Modular Multilevel Converter(MMC)in power grid applications,there are two types of hybrid DC system topologies:one is the parallel connection ... Based on the complementary advantages of Line Commutated Converter(LCC)and Modular Multilevel Converter(MMC)in power grid applications,there are two types of hybrid DC system topologies:one is the parallel connection of LCC converter stations and MMC converter stations,and the other is the series connection of LCC and MMC converter stations within a single station.The hybrid DC transmission system faces broad application prospects and development potential in large-scale clean energy integration across regions and the construction of a new power system dominated by new energy sources in China.This paper first analyzes the system forms and topological characteristics of hybrid DC transmission,introducing the forms and topological characteristics of converter-level hybrid DC transmission systems and system-level hybrid DC transmission systems.Next,it analyzes the operating characteristics of LCC and MMC inverter-level hybrid DC transmission systems,provides insights into the transient stability of hybrid DC transmission systems,and typical fault ride-through control strategies.Finally,it summarizes the networking characteristics of the LCC-MMC series within the converter station hybrid DC transmission system,studies the transient characteristics and fault ridethrough control strategies under different fault types for the LCC-MMC series in the receiving-end converter station,and investigates the transient characteristics and fault ride-through control strategies under different fault types for the LCC-MMC series in the sending-end converter station. 展开更多
关键词 hybrid DC transmission Transient stability CONFIGURATION Control system
下载PDF
Systematic Synthesis of Dedicated Hybrid Transmission 被引量:3
2
作者 Lin Li Haijun Chen Ferit Küçükay 《Automotive Innovation》 EI CSCD 2019年第3期231-239,共9页
The great diversity of dedicated hybrid transmissions(DHTs)requires a method to identify solutions among all potential concepts involved in each structure.Therefore,a DHT synthesis tool is developed on the basis of ge... The great diversity of dedicated hybrid transmissions(DHTs)requires a method to identify solutions among all potential concepts involved in each structure.Therefore,a DHT synthesis tool is developed on the basis of general transmission synthesis.In the first synthesis step,transmission structures are generated with only conventional functions such as driving with only the internal combustion engine.Electric machines are then installed in the transmissions to achieve further hybrid functions,including boosting,eCVT and electric driving modes.The number of generated transmission concepts increases exponentially with each synthesis step.Various evaluations are carried out successively to identify the most suitable DHT concepts among the many possible solutions.The generated DHT concepts are evaluated in terms of structural feasibility,driving modes,drivability and load factors on transmission components.An example of DHT synthesis involving planetary gear sets is explained in detail.The best five DHT structures are identified out of more than 120 billion solutions. 展开更多
关键词 Dedicated hybrid transmission transmission design SYNTHESIS Structural evaluation
原文传递
Energy control strategy for parallel hydrostatic transmission hybrid vehicles 被引量:1
3
作者 孙辉 姜继海 王昕 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2009年第4期475-480,共6页
Aimed at the relatively lower energy density and complicated coordinating operation between two power sources,a special energy control strategy is required to maximize the fuel saving potential.Then a new type of conf... Aimed at the relatively lower energy density and complicated coordinating operation between two power sources,a special energy control strategy is required to maximize the fuel saving potential.Then a new type of configuration for hydrostatic transmission hybrid vehicles(PHHV) and the selection criterion for important components are proposed.Based on the optimization of planet gear transmission ratio and the analysis of optimal energy distribution for the proposed PHHV on a representative urban driving cycle,a fuzzy torque control strategy and a braking energy regeneration strategy are designed and developed to realize the real-time control of energy for the proposed PHHV.Simulation results demonstrate that the energy control strategy effectively improves the fuel economy of PHHV. 展开更多
关键词 hybrid vehicle with hydrostatic transmission energy control strategy parameters optimization hy-draulic pump/motor
下载PDF
OPTIMAL TORQUE CONTROL STRATEGY FOR PARALLEL HYBRID ELECTRIC VEHICLE WITH AUTOMATIC MECHANICAL TRANSMISSION 被引量:12
4
作者 GU Yanchun YIN Chengliang ZHANG Jianwu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第1期16-20,共5页
In parallel hybrid electrical vehicle (PHEV) equipped with automatic mechanical transmission (AMT), the driving smoothness and the clutch abrasion are the primary considerations for powertrain control during gears... In parallel hybrid electrical vehicle (PHEV) equipped with automatic mechanical transmission (AMT), the driving smoothness and the clutch abrasion are the primary considerations for powertrain control during gearshift and clutch operation. To improve these performance indexes of PHEV, a coordinated control system is proposed through the analyzing of HEV powertrain dynamic characteristics. Using the method of minimum principle, the input torque of transmission is optimized to improve the driving smoothness of vehicle. Using the methods of fuzzy logic and fuzzy-PID, the engaging speed of clutch and the throttle opening of engine are manipulated to ensure the smoothness of clutch engagement and reduce the abrasion of clutch friction plates. The motor provides the difference between the required input torque of transmission and the torque transmitted through clutch plates. Results of simulation and experiments show that the proposed control strategy performs better than the contrastive control system, the smoothness of driving and the abrasion of clutch can be improved simultaneously. 展开更多
关键词 Parallel hybrid electric vehicle (PHEV) Automatic mechanical transmission (AMT) Driving smoothness Clutch abrasion Optimal control Fuzzy logic control
下载PDF
Characteristics of Bi-2223 HTS Tapes Under Short-Circuit Current Impacts in Hybrid Energy Transmission Pipelines
5
作者 Yuguang Sun Chao Yin +2 位作者 Weizhen Li Xinyang Li Xiaohua Jiang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期736-745,共10页
A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power ca... A hybrid energy transmission pipeline is proposed with the aim of long-distance cooperative transmission of electricity and chemical fuels, which is composed of an inner high-temperature superconducting (HTS) power cable and outer liquefied natural gas (LNG) pipeline. The flowing LNG could maintain the operating temperature of the inner HTS power cable within the range of 85 K-90 K, thus the Bi-2223 superconductors in the HTS power cable produce little Joule loss with the transmission current below the critical current. Owing to the advantages of high power density, low transmission losses and economical manufacturing costs, the hybrid energy transmission pipeline is expected to be widely utilized in the near future. In order to ensure the safety of the HTS power cable and explosive LNG in case of short-circuit faults, this paper tests and analyzes the characteristics of Bi-2223 HTS tapes of the Type HT-CA, Type HT-SS and Type H models under short-circuit current impacts at the LNG cooling temperature (85 K-90 K). An experimental platform is designed and established for the ampacity tests of HTS tapes above LN2 cooling temperature (77 K). The AC over-current impact tests at 85 K-90 K are carried out on each sample of Bi-2223 tapes respectively, and the experimental results are analyzed and compared to evaluate their performances under different operating conditions. The results indicate that the Type HT-CA tape can withstand 50 Hz short-circuit current impact with the amplitude of 1108 A (10 times of critical current Ic ) for 100 ms at 90 K, and its resistance is the smallest of the three tested samples under similar current impacts. Therefore, the Type HT-CA Bi-2223 tape is the optimal superconductor of the HTS power cable in the hybrid energy transmission pipeline. 展开更多
关键词 Bi-2223 high-temperature superconducting(HTS)tape critical current hybrid energy transmission pipeline liquefied natural gas(LNG)cooling temperature short-circuit current impact characteristics
原文传递
Traveling Wave Characteristics Based Pilot Protection Scheme for Hybrid Cascaded HVDC Transmission Line
6
作者 Dalin Mu Sheng Lin Xiaopeng Li 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第3期971-980,共10页
The hybrid cascaded high-voltage direct current(HVDC)transmission system has various operation modes,and some operation modes have sharply increasing requirements for protection rapidity,while the traditional pilot di... The hybrid cascaded high-voltage direct current(HVDC)transmission system has various operation modes,and some operation modes have sharply increasing requirements for protection rapidity,while the traditional pilot differential protection(PDP)has poor rapidity,and even refuses to operate when faults occur on the DC line.Therefore,a novel pilot protection scheme based on traveling wave characteristics is proposed.First,the adaptability of the traditional PDP applied in engineering is analyzed for different operation modes.Then,the expressions of the forward traveling wave(FTW)and backward traveling wave(BTW)on the rectifier side and the inverter side are derived for different fault locations.From the theoretical derivation,the difference between the BTW and FTW on the rectifier side is less than zero,and the same is true on the inverter side.However,in the event of an external fault of DC line,the difference between the BTW and FTW at nearfault terminal protection installation point is greater than zero.Therefore,by summing over the product of the difference between BTW and FTW of the rectifier side and that of the inverter side,the fault identification criterion is constructed.The simulation results show that the proposed pilot protection scheme can quickly and reliably identify the short-circuit faults of DC line in different operation modes. 展开更多
关键词 hybrid cascaded high-voltage direct current(HVDC)transmission system DC line operation mode pilot protection
原文传递
A Double-Ended Protection Principle for an LCC-VSC-MTDC System with Strong Anti-Interference Ability
7
作者 ChuanjianWu Dahai Zhang Jinghan He 《Energy Engineering》 EI 2023年第2期299-316,共18页
The DC grid technology of multi-power supply and multi-drop-point power reception is an effective solution for large-scale renewable energy integration into the power grid.Line-commutated converter-Voltage source conv... The DC grid technology of multi-power supply and multi-drop-point power reception is an effective solution for large-scale renewable energy integration into the power grid.Line-commutated converter-Voltage source converter(LCC-VSC)power grids are one of the more important developmental directions of the future power grid that have occured in recent years.But the multi-terminal high voltage direct current system has the problems of inconsistent boundary characteristics,inconsistent control,and fault response characteristics,which puts higher requirements on the protection scheme.Thus,a completely new protection principle is proposed in this paper.Firstly,the fault characteristics of distributed capacitance current are analyzed.The reactive power calculated by the distribution parameters of different frequencies is different.Subsequently,the fault characteristics of DC reactive power are analyzed,and a DC reactive power extraction algorithm is proposed.The polarity of the multi-band DC reactive power is used to construct the protection scheme.Finally,the LCC-VSC power grid model verifies the correctness and superiority of the proposed protection scheme.The proposed scheme uses DC reactive power instead of fault current to solve the long delay problem caused by distributed capacitance.Compared with the prior art,the proposed solution is not affected by distributed capacitance and has a stronger anti-interference ability(600Ω+10 dB+1 ms). 展开更多
关键词 hybrid DC transmission double-ended protection S transform Hilbert transform
下载PDF
A Single-Ended Protection Principle for LCC-VSC-MTDC System with High Resistance Fault Tolerance
8
作者 Dahai Zhang Chuanjian Wu Jinghan He 《Energy Engineering》 EI 2023年第1期1-21,共21页
Line-commutated converter-voltage source converter(LCC-VSC)power transmission technology does not have the problem of communication failure very usually.It therefore can support the long-distance,long-capacity transmi... Line-commutated converter-voltage source converter(LCC-VSC)power transmission technology does not have the problem of communication failure very usually.It therefore can support the long-distance,long-capacity transmission of electric energy.However,factors such as topology,control strategy,and short-circuit capacities make the traditional protection principles not fully applicable to LCC-VSC hybrid transmission systems.To enhance the reliability of hybrid DC systems,a single-ended principle based on transmission coefficients is proposed and produced.First,the equivalent circuit of the LCC-VSC hybrid DC system is analyzed and the expression of the first traveling wave is deduced accordingly.Then,the concept of multi-frequency transmission coefficients is proposed by analyzing the amplitude-frequency,and the characteristics of each element.Finally,the LCC-VSCDC system model is built to verify the reliability and superiority of the principle itself.Theoretical analysis and experimental verification show that the principle has strong interference resistance. 展开更多
关键词 hybrid DC transmission single-ended protection principle multi-frequency transmission coefficient
下载PDF
交直流混合输电线路空间电场分析(英文) 被引量:6
9
作者 李倩 刘俊翔 +1 位作者 李华 林福昌 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2866-2872,共7页
As the transmission line corridors become more and more rare in China,it is now inevitable for people to construct HVAC-HVDC hybrid transmission lines.The research on the electric field around the transmission lines p... As the transmission line corridors become more and more rare in China,it is now inevitable for people to construct HVAC-HVDC hybrid transmission lines.The research on the electric field around the transmission lines plays an important role in evaluating the electromagnetic environment nearby.However,few existing research now considered the mutual effect of HVAC-HVDC hybrid transmission lines.Thus,this research designed a program based on windows,which calculated the surface voltage gradient on the transmission lines and the electric field at ground level respectively.This research calculated the surface voltage gradient on the transmission lines by applying the improved method of successive images.For the electric field at ground level under AC transmission line,simulation charge method is used,while for the electric field at the ground level under DC transmission lines,deutsch assumption method is used.Comparing the results generated by the calculation with those in published literature,the program is reliable.Taking 500 kV transmission lines as an example,when considering the mutual effect of the HVAC-HVDC lines,the amplitude of the surface voltage gradient will increase by about 10%and the amplitude of the electric field at ground level will increase by about 8%,making the mutual effect of the AC and DC lines unneglectable. Larger part of the electric field at ground level under hybrid lines is produced by the DC line.Thus,in order to control the electric field at ground level under hybrid lines,it should pay more attention on that produced by the DC line. 展开更多
关键词 hybrid transmission lines method of successive images simulation charge method deutsch assumption method conductor surface gradient the ionized field
下载PDF
Morphological and phylogenetic diversity of magnetotactic bacteria and multicellular magnetotactic prokaryotes from a mangrove ecosystem in the Sanya River,South China 被引量:1
10
作者 Haitao CHEN Jinhua LI +1 位作者 Long-Fei WU Wei-Jia ZHANG 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2021年第6期2015-2026,共12页
Magnetotactic bacteria(MTB)are morphologically and phylogenetically diverse prokaryotes commonly able to produce magnetic nanocrystals within intracellular membrane-bound organelles(i.e.,magnetosomes)and to swim along... Magnetotactic bacteria(MTB)are morphologically and phylogenetically diverse prokaryotes commonly able to produce magnetic nanocrystals within intracellular membrane-bound organelles(i.e.,magnetosomes)and to swim along geomagnetic field lines.We studied the diversity of MTB in the samples collected from a mangrove area in the Sanya River,Hainan,South China,using microscopic and microbial phylogenetic methods.Results of microanalysis and observation in microscopy and energy dispersive X-ray spectroscopy(EDXS)reveal a highly morphological diversity of MTB including unicellular cocci,vibrios,rod-shaped bacteria,and three morphotypes of multicellular magnetotactic prokaryotes(MMPs).In addition,analysis of the 16S rRNA gene showed that these MTB were clustered into 16 operational taxonomic units affi liated to the Alpha-,Delta-,and Gamma-proteobacteria classes within the Proteobacteria phylum.Meanwhile,by using the coupled fluorescence and transmission electron microscopy analysis,rodshaped bacteria,vibrio,and cocci were phylogenetically and structurally identified at the single-cell level.This study demonstrated highly diverse MTB communities in the mangrove ecosystem and provide a new insight into the overall diversity of MTB. 展开更多
关键词 magnetotactic bacteria diversity MAGNETOSOME phylogenetic analysis coordinated fl uorescence in-situ hybridization transmission electron microscopy(FISH-TEM) MANGROVE
下载PDF
Progress in Automotive Transmission Technology 被引量:12
11
作者 Xiangyang Xu Peng Dong +1 位作者 Yanfang Liu Hui Zhang 《Automotive Innovation》 EI 2018年第3期187-210,共24页
Much progress has been made in the development of automotive transmissions over the past 20 years,e.g.,an increased speed number,expanded ratio spread and improved efficiency and shift quality.Automotive transmissions... Much progress has been made in the development of automotive transmissions over the past 20 years,e.g.,an increased speed number,expanded ratio spread and improved efficiency and shift quality.Automotive transmissions are moving toward electrification in response to stringent legislation on emissions and the pressing demand for better fuel economy.This paper reviews progress in automotive transmission technology.Assisted by computer-aided programs,new transmission schemes are constantly being developed.We therefore first introduce the synthesis of the transmission scheme and parameter optimization.We then discuss the progress in the transmission technology of a conventional internal combustion engine vehicle in terms of new layouts;improved efficiency;noise,vibration and harshness technology;and the shifting strategy and control technology.As the major development trend,transmission electrification is subsequently discussed;this discussion includes the configuration design,energy management strategy,hybrid mode shifting control,single-speed and multi-speed electric vehicle transmission and distributed electric drive.Finally,a summary and outlook are presented for conventional automotive transmissions,hybrid transmissions and electric vehicle transmissions. 展开更多
关键词 Automotive transmission hybrid transmission Electric vehicle transmission Distributed electric drive Scheme synthesis ELECTRIFICATION
原文传递
Study of Series-Parallel and Power-Split DHT for Hybrid Powertrains 被引量:2
12
作者 Haijun Chen Lin Li Ferit Kucukay 《Automotive Innovation》 CSCD 2021年第1期23-33,共11页
Dedicated hybrid transmission(DHT)is the developing trend of hybrid transmissions.This paper studies different types of DHTs regarding the structure,function,and performance.Firstly,the structure and function of diffe... Dedicated hybrid transmission(DHT)is the developing trend of hybrid transmissions.This paper studies different types of DHTs regarding the structure,function,and performance.Firstly,the structure and function of different well-known DHTs in the market are discussed and analyzed.Through the analysis,the reasonability and necessity of the different modes and the electric motor power requirements that lie behind different DHTs are derived.Secondly,the dynamics of different DHTs are further compared with the driving areas in different modes under different driving conditions.Then,the basic or minimum dynamic requirements are defined and taken into consideration before the economic comparison.To ensure the effectiveness of the comparison,the optimization of the configurations for each kind of DHT is carried out with the modular simulation model.The economic comparison is conducted under the premise of excluding the influences of the configurations in the results.Finally,the sensitivity and influence of different engine characteristics for different DHTs are studied to find out the sensibilities of the two kinds of DHTs with engine technology.Through these studies,the essential differences and features of different DHTs can be derived to help better understand the decision in choosing the technical route for the original equipment manufacturers. 展开更多
关键词 Dedicated hybrid transmission Series-parallel DHT Power-split DHT Mechanical complexity Electrical complexity
原文传递