Pre-treatment of pyridine wastewater by new cathodic–anodic-electrolysis packing 被引量:6
1
作者 Yang Jin Qinyan Yue +4 位作者 Kunlun Yang Suqing Wu Shengjie Li Baoyu Gao Yuan Gao 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第1期43-49,共7页
A novel cathodic–anodic-electrolysis packing(CAEP) used in the treatment of pyridine wastewater was researched, which mainly consisted of 4,4′-diamino-2,2′-disulfonic acid(DSD acid) industrial iron sludge. The ... A novel cathodic–anodic-electrolysis packing(CAEP) used in the treatment of pyridine wastewater was researched, which mainly consisted of 4,4′-diamino-2,2′-disulfonic acid(DSD acid) industrial iron sludge. The physical properties and morphology of the packing were studied. The CAEP was used in a column reactor during the pretreatment of pyridine wastewater. The influence of p H, hydraulic retention time(HRT), the air–liquid ratio(A/L)and the initial concentration of pyridine were investigated by measuring the removal of total organic carbon(TOC) and pyridine. The characterization results showed that the bulk density, grain density, water absorption percentage and specific surface area were 921 kg/m3,1086 kg/m3, 25% and 29.89 m^2/g, respectively; the removal of TOC and pyridine could reach50% and 58% at the optimal experimental conditions(p H = 3, HRT = 8 hr, A/L = 2). Notably,the surface of the packing was renewed constantly during the running of the filter, and the handling capacity was stable after running for three months. 展开更多
关键词 Cathodic-anodic-electrolysis packing Pyridine wastewater pH hydraulic retention time Air-liquid ratio Initial concentration