Hydraulic Stewart platform is characterized by nonlinearity for driving system in essence,severe load coupling among the legs,which bring a great difficulty for controller design and performance improvement.Afore cont...Hydraulic Stewart platform is characterized by nonlinearity for driving system in essence,severe load coupling among the legs,which bring a great difficulty for controller design and performance improvement.Afore controller research is either low in tracking performance and movement smoothness when it ignores the nonlinearity and dynamics coupling,or complex in algorithm and has the need of acceleration feedback or observer when the dynamics coupling and nonlinearity is included.To solve the dilemma,a new controller,backstepping adaptive control of hydraulic Stewart platform using dynamic surface is put forward based on the complete dynamics including the upper platform dynamics and hydraulic nonlinearity in driving system.Asymptotic stability of the whole system is proved by Lyapunov method.The proposed algorithm is simple by avoiding the use of acceleration.The simulation results indicate that the control algorithm performs better than the normal PID controller in control precision,dynamic response and depression of the cross coupling.展开更多
In order to solve the problem of difficult modeling and identification caused by time-variable parameters,multiple inputs and outputs and unstable open loop,a subsystem model-based close-loop grey-box identification m...In order to solve the problem of difficult modeling and identification caused by time-variable parameters,multiple inputs and outputs and unstable open loop,a subsystem model-based close-loop grey-box identification method was put forward when consider the main coupling effects of hydraulic Stewart platform.Firstly,the whole system is divided into three TITO(Two Input Two Output) subsystems according to the characteristics of the pseudo-mass matrix,hence transfer function matrix model of the subsystem can also be found.Secondly,since the Stewart platform is unstable,the close-loop transfer model of the subsystem is derived under the proportional controllers.The inverse M serial is adopted as the identification signal to get the experimental data.All parameters of the subsystem are determined in close-loop indirect identification by PEM(Prediction Error Method).Finally,a case study validates the correctness and effectiveness of the subsystem model-based close-loop grey-box identification method for hydraulic Stewart platform.展开更多
文摘Hydraulic Stewart platform is characterized by nonlinearity for driving system in essence,severe load coupling among the legs,which bring a great difficulty for controller design and performance improvement.Afore controller research is either low in tracking performance and movement smoothness when it ignores the nonlinearity and dynamics coupling,or complex in algorithm and has the need of acceleration feedback or observer when the dynamics coupling and nonlinearity is included.To solve the dilemma,a new controller,backstepping adaptive control of hydraulic Stewart platform using dynamic surface is put forward based on the complete dynamics including the upper platform dynamics and hydraulic nonlinearity in driving system.Asymptotic stability of the whole system is proved by Lyapunov method.The proposed algorithm is simple by avoiding the use of acceleration.The simulation results indicate that the control algorithm performs better than the normal PID controller in control precision,dynamic response and depression of the cross coupling.
文摘In order to solve the problem of difficult modeling and identification caused by time-variable parameters,multiple inputs and outputs and unstable open loop,a subsystem model-based close-loop grey-box identification method was put forward when consider the main coupling effects of hydraulic Stewart platform.Firstly,the whole system is divided into three TITO(Two Input Two Output) subsystems according to the characteristics of the pseudo-mass matrix,hence transfer function matrix model of the subsystem can also be found.Secondly,since the Stewart platform is unstable,the close-loop transfer model of the subsystem is derived under the proportional controllers.The inverse M serial is adopted as the identification signal to get the experimental data.All parameters of the subsystem are determined in close-loop indirect identification by PEM(Prediction Error Method).Finally,a case study validates the correctness and effectiveness of the subsystem model-based close-loop grey-box identification method for hydraulic Stewart platform.