Objective To examine the effect of hydraulic residence time (HRT) on the performance and stability, to treat dilute wastewater at different operational temperatures in a carrier anaerobic baffled reactor (CABR), a...Objective To examine the effect of hydraulic residence time (HRT) on the performance and stability, to treat dilute wastewater at different operational temperatures in a carrier anaerobic baffled reactor (CABR), and hence to gain a deeper insight into microbial responses to hydraulic shocks on the base of the relationships among macroscopic performance, catabolic intermediate, and microcosmic alternation. Methods COD, VFAs, and microbial activity were detected with constant feed strength (300 mg/L) at different HRTs (9-18 h) and temperatures (10℃-28℃) in a CABR. Results The removal efficiencies declined with the decreases of HRTs and temperatures. However, the COD removal load was still higher at short HRT than at long HRT. Devastating reactor performance happened at temperature of 10℃ and at HRT of 9 h. HRTs had effect on the VFAs in the reactor slightly both at high and low temperatures, but the reasons differed from each other. Microbial activity was sensitive to indicate changes of environmental and operational parameters in the reactor. Conclusion The CABR offers to certain extent an application to treat dilute wastewater under a hydraulic-shock at temperatures from 10℃to 28℃.展开更多
The optimal operation conditions in an anoxic sulfide oxidizing (ASO) bioreactor were investigated. The maximal removal rates for sulfide and nitrate were found to be 4.18 kg/(m3·d) and 1.73 kg/(m3·d), respe...The optimal operation conditions in an anoxic sulfide oxidizing (ASO) bioreactor were investigated. The maximal removal rates for sulfide and nitrate were found to be 4.18 kg/(m3·d) and 1.73 kg/(m3·d), respectively. The volumetrical volumetric loading rates (LRs) observed through decreasing hydraulic retention time (HRT) at fixed substrate concentration are higher than those by increasing substrate concentration at fixed HRT. The sulfide oxidation in ASO reactor was partially producing both sulfate and sulfur; but the amount of sulfate produced was approximately one third that of sulfur. The process was able to tolerate high sulfide concentration, as the sulfide removal percentage always remained near 99% when influent concentration was up to 580 mg/L. It tolerated relatively lower nitrate concentration because the removal percentage dropped to 85% when influent con- centration was increased above 110 mg/L. The process can tolerate shorter HRT but careful operation is needed. Nitrate conversion was more sensitive to HRT than sulfide conversion since the process performance deteriorated abruptly when HRT was decreased from 3.12 h to 2.88 h. In order to avoid nitrite accumulation in the reactor, the influent sulfide and nitrate concentrations should be kept at 280 mg/L and 67.5 mg/L respectively. Present biotechnology is useful for removing sulfides from sewers and crude oil.展开更多
With rural population expansion and improvement of the socio-economic standard of living, treatment of rural domestic wastewater has rapidly become a major aspect of environmental concern. Selection of a suitable meth...With rural population expansion and improvement of the socio-economic standard of living, treatment of rural domestic wastewater has rapidly become a major aspect of environmental concern. Selection of a suitable method for treatment of rural domestic wastewater depends on its efficiency, simplicity, and cost-effectiveness. This study investigated the effects of hydraulic retention time (HRT), temperature, and effluent recycling on the treatment efficiency of an anaerobic filter (AF) reactor. The first round of experimental operations was run for three months with HRTs of one, two, and three days, temperatures of 18℃, 21℃, and 24℃, and no effluent recycling. The second round of experimental operations was conducted for another three months with HRTs of three and four days; temperatures of 30.67℃, 30.57℃, and 26.91 ℃ ; and three effluent recycling ratios of 1:1, 1:2, and 2:1. The first round of operations showed removal rates of 32% to 44% for COD, 30% to 35% for TN, 32% to 36% for NH4-N, 19% to 23% for NO3-N, and 12% to 22% for TE In the second round of operations, the removal rates varied from 75% to 81% for COD, 35% to 41% for TN, 31% to 39% for NH4-N, 30% to 34% for NO3-N, and 41% to 48% for TP. The average gas production rates were 6.72 L/d and 7.26 L/d for the first and second rounds of operations, respectively. The gas production rate increased in the second round of operations as a result of applied effluent recycling. The best removal efficiency was obtained for an optimum HRT of three days, a temperature of 30℃, and an effluent recycling ratio of 2:1. The results show that the removal efficiency of the AF reactor was affected by HRT, temperature, and effluent recycling.展开更多
Systems that have big transmission line may have problem on changes of pressure in the distribution system. Because the increase in water age is dependent on the difference between the production and consumption rates...Systems that have big transmission line may have problem on changes of pressure in the distribution system. Because the increase in water age is dependent on the difference between the production and consumption rates, high residence time in pipes and storage duration in water tanks. The goal of this study is to analyze the effects residence time to water quality in large water distribution systems. According to the results in Ahwaz, bacterial growth (HPC) has a direct relationship with water age, and changing rate of the bacterial growth (HPC) and the distance travelled and residence time have been caused to increase water age, bacterial growth (HPC), chlorine consumption and hydraulic change. So bacterial growth (HPC) doesn’t have any relationship with THMs and Tol Coli form, but has a reversed relationship with residual chlorine nearly.展开更多
A subsurface flow wetland(SSFW)was simulated using a commercial computational fluid dynamic(CFD)code.The constructed media was simulated using porous media and the liquid resident time distribution(RTD)in the SSFW was...A subsurface flow wetland(SSFW)was simulated using a commercial computational fluid dynamic(CFD)code.The constructed media was simulated using porous media and the liquid resident time distribution(RTD)in the SSFW was obtained using the particle trajectory model.The effect of wetland configuration and operating conditions on the hydraulic performance of the SSFW were investigated.The results indicated that the hydraulic performance of the SSFW was predominantly affected by the wetland configuration.The hydr...展开更多
A swimming pool can be considered as a chemical reactor with specific hydraulic and macro-mixing characteristics. The nature of flow into the pool depends on various characteristics, such as water inlets and outlets (...A swimming pool can be considered as a chemical reactor with specific hydraulic and macro-mixing characteristics. The nature of flow into the pool depends on various characteristics, such as water inlets and outlets (number and position), pool geometry, and flow rate. This study investigates how swimming pool design affects hydraulic behavior based on experimental and computational fluid dynamics studies (CFD). This paper does not describe the hydraulic behavior of all existing swimming pools, however the cases studied here are representative of pool designs widely used in Europe and the United States. The model developed, based on the principle of a stirred reactor, could be used as a first approach in describing the hydraulic behavior of regular pools. This model is suitable for the study of physical and chemical phenomena with long characteristic times. Other, more advanced, models were shown to be more suitable to the case of fast chemical processes.展开更多
基金project supported by the Science and Technology Department of Zhejiang Province (2005C13003).
文摘Objective To examine the effect of hydraulic residence time (HRT) on the performance and stability, to treat dilute wastewater at different operational temperatures in a carrier anaerobic baffled reactor (CABR), and hence to gain a deeper insight into microbial responses to hydraulic shocks on the base of the relationships among macroscopic performance, catabolic intermediate, and microcosmic alternation. Methods COD, VFAs, and microbial activity were detected with constant feed strength (300 mg/L) at different HRTs (9-18 h) and temperatures (10℃-28℃) in a CABR. Results The removal efficiencies declined with the decreases of HRTs and temperatures. However, the COD removal load was still higher at short HRT than at long HRT. Devastating reactor performance happened at temperature of 10℃ and at HRT of 9 h. HRTs had effect on the VFAs in the reactor slightly both at high and low temperatures, but the reasons differed from each other. Microbial activity was sensitive to indicate changes of environmental and operational parameters in the reactor. Conclusion The CABR offers to certain extent an application to treat dilute wastewater under a hydraulic-shock at temperatures from 10℃to 28℃.
基金Project supported by the National Natural Science Foundation of China (No. 30070017)the Science and Technology Foundation for Key Project of Zhejiang Province (No. 2003C13005), China
文摘The optimal operation conditions in an anoxic sulfide oxidizing (ASO) bioreactor were investigated. The maximal removal rates for sulfide and nitrate were found to be 4.18 kg/(m3·d) and 1.73 kg/(m3·d), respectively. The volumetrical volumetric loading rates (LRs) observed through decreasing hydraulic retention time (HRT) at fixed substrate concentration are higher than those by increasing substrate concentration at fixed HRT. The sulfide oxidation in ASO reactor was partially producing both sulfate and sulfur; but the amount of sulfate produced was approximately one third that of sulfur. The process was able to tolerate high sulfide concentration, as the sulfide removal percentage always remained near 99% when influent concentration was up to 580 mg/L. It tolerated relatively lower nitrate concentration because the removal percentage dropped to 85% when influent con- centration was increased above 110 mg/L. The process can tolerate shorter HRT but careful operation is needed. Nitrate conversion was more sensitive to HRT than sulfide conversion since the process performance deteriorated abruptly when HRT was decreased from 3.12 h to 2.88 h. In order to avoid nitrite accumulation in the reactor, the influent sulfide and nitrate concentrations should be kept at 280 mg/L and 67.5 mg/L respectively. Present biotechnology is useful for removing sulfides from sewers and crude oil.
基金supported by the National Natural Science Foundation of China(Grant No.51078074)the Key Project of the Chinese Ministry of Education(Grant No.308010)
文摘With rural population expansion and improvement of the socio-economic standard of living, treatment of rural domestic wastewater has rapidly become a major aspect of environmental concern. Selection of a suitable method for treatment of rural domestic wastewater depends on its efficiency, simplicity, and cost-effectiveness. This study investigated the effects of hydraulic retention time (HRT), temperature, and effluent recycling on the treatment efficiency of an anaerobic filter (AF) reactor. The first round of experimental operations was run for three months with HRTs of one, two, and three days, temperatures of 18℃, 21℃, and 24℃, and no effluent recycling. The second round of experimental operations was conducted for another three months with HRTs of three and four days; temperatures of 30.67℃, 30.57℃, and 26.91 ℃ ; and three effluent recycling ratios of 1:1, 1:2, and 2:1. The first round of operations showed removal rates of 32% to 44% for COD, 30% to 35% for TN, 32% to 36% for NH4-N, 19% to 23% for NO3-N, and 12% to 22% for TE In the second round of operations, the removal rates varied from 75% to 81% for COD, 35% to 41% for TN, 31% to 39% for NH4-N, 30% to 34% for NO3-N, and 41% to 48% for TP. The average gas production rates were 6.72 L/d and 7.26 L/d for the first and second rounds of operations, respectively. The gas production rate increased in the second round of operations as a result of applied effluent recycling. The best removal efficiency was obtained for an optimum HRT of three days, a temperature of 30℃, and an effluent recycling ratio of 2:1. The results show that the removal efficiency of the AF reactor was affected by HRT, temperature, and effluent recycling.
文摘Systems that have big transmission line may have problem on changes of pressure in the distribution system. Because the increase in water age is dependent on the difference between the production and consumption rates, high residence time in pipes and storage duration in water tanks. The goal of this study is to analyze the effects residence time to water quality in large water distribution systems. According to the results in Ahwaz, bacterial growth (HPC) has a direct relationship with water age, and changing rate of the bacterial growth (HPC) and the distance travelled and residence time have been caused to increase water age, bacterial growth (HPC), chlorine consumption and hydraulic change. So bacterial growth (HPC) doesn’t have any relationship with THMs and Tol Coli form, but has a reversed relationship with residual chlorine nearly.
基金The authors are grateful to"Chemical Grid Project"of Beijing University of Chemical Technology for providingthe computer facilities.
文摘A subsurface flow wetland(SSFW)was simulated using a commercial computational fluid dynamic(CFD)code.The constructed media was simulated using porous media and the liquid resident time distribution(RTD)in the SSFW was obtained using the particle trajectory model.The effect of wetland configuration and operating conditions on the hydraulic performance of the SSFW were investigated.The results indicated that the hydraulic performance of the SSFW was predominantly affected by the wetland configuration.The hydr...
文摘A swimming pool can be considered as a chemical reactor with specific hydraulic and macro-mixing characteristics. The nature of flow into the pool depends on various characteristics, such as water inlets and outlets (number and position), pool geometry, and flow rate. This study investigates how swimming pool design affects hydraulic behavior based on experimental and computational fluid dynamics studies (CFD). This paper does not describe the hydraulic behavior of all existing swimming pools, however the cases studied here are representative of pool designs widely used in Europe and the United States. The model developed, based on the principle of a stirred reactor, could be used as a first approach in describing the hydraulic behavior of regular pools. This model is suitable for the study of physical and chemical phenomena with long characteristic times. Other, more advanced, models were shown to be more suitable to the case of fast chemical processes.
文摘污水厂尾水回用作为水源时,其ρ(TN)较高是亟待解决的问题.在调研污水厂尾水水质的基础上,利用MBBR(移动床生物膜反应器)对其进行深度脱氮,并考察HRT(水力停留时间)对不同填料(聚乙烯和陶粒)的MBBR运行效果的影响.结果表明,NO3--N是尾水中氮的主要形态,其质量浓度约占ρ(TN)的80.8%±8.4%.HRT分别为12、8和4 h时,对NO3--N去除率影响不大,均能达到90%以上,但反硝化能力随着HRT的缩短而成倍增加;HRT为4 h时各反应器的反硝化能力最大,聚乙烯和陶粒MBBR中分别为(28.4±14.5)和(27.4±14.3)mg(L·d)(以NO3--N计).随着HRT的减少,CODCr去除率呈降低趋势.三维荧光分析表明,进、出水中均含有类富里酸和类蛋白质等DOM物质.HRT为8 h时MBBR对DOM的去除率最高,聚乙烯填料MBBR对有机污染物的去除效果略优于陶粒填料.综合考虑氮和有机污染物去除效能,聚乙烯和陶粒填料MBBR优化HRT均为8 h.