The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refri...The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refrigeration cycle operating with a hydrocarbon refrigerant. The hydrocarbon refrigerants considered are propane(R290), butane(R600), isobutane(R600a), and propylene(R1270). A computer program written in FORTRAN is developed to compute parameters for characteristic points of the cycles and the system's performance, which is determined and analyzed using numerical solutions for the refrigerant condensation temperature, temperature in tank, and temperature difference in the cascade condenser. Results show that R600 a gives the best performance, followed by(in order) R600, R290, and R1270. Furthermore, it is found that an increase in tank temperature improves system performance but that an increase in refrigerant condensation temperature causes deterioration. In addition, it is found that running the system at a low temperature difference in the cascade condenser is advantageous.展开更多
Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines...Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines. This research presents the thermodynamic analysis on cascade refrigeration system (CRS) with several refrigerant pairs which are R32/R170, R123/R170, R134a/R170, R404A/R170, R407c/R170, R410/R170, and the hydrocarbon (HC) refrigerant pair Propane/Ethane, namely R290/R170. Besides, the results of R22/R170 pair, which is not recommended to be used due to phase out of R22 as per Montréal Protocol, are included as base case to compare the novel hydrocarbon pairs in CRS and the old trend of refrigerant pairs. Thermodynamic properties of all these pairs were investigated and compared under different intermediate temperature used in CRS heat exchanger, which thermally connected both the Low and High temperature cycles (LTC) and (HTC). By applying the first law of thermodynamics, the coefficients of performance (COPs) and the specific power consumptions (SPC) in kW/TR are presented and compared. In addition, by applying the second law of thermodynamics the exergetic efficiencies were estimated. The results reveal the promising opportunity of using the HC pair (R290/R170). The minimum SPC in kW/TR is recorded for the pair R123/R170. One the other hand, the highest exegetic efficiency values are observed to be 40%, 38%, and 35% for the pairs R123/R170, R290/R170, and R134/R170, respectively. This research concludes that the HC pair (R290/R170) is highly recommended for CRS applications either to transport the COVID-19 or store it in cold storage rooms in hospitals and clinics. All precautionary measures should be carefully applied in design and operation of HC pair (R290/R170) due to its flammability hazard.展开更多
文摘The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refrigeration cycle operating with a hydrocarbon refrigerant. The hydrocarbon refrigerants considered are propane(R290), butane(R600), isobutane(R600a), and propylene(R1270). A computer program written in FORTRAN is developed to compute parameters for characteristic points of the cycles and the system's performance, which is determined and analyzed using numerical solutions for the refrigerant condensation temperature, temperature in tank, and temperature difference in the cascade condenser. Results show that R600 a gives the best performance, followed by(in order) R600, R290, and R1270. Furthermore, it is found that an increase in tank temperature improves system performance but that an increase in refrigerant condensation temperature causes deterioration. In addition, it is found that running the system at a low temperature difference in the cascade condenser is advantageous.
文摘Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines. This research presents the thermodynamic analysis on cascade refrigeration system (CRS) with several refrigerant pairs which are R32/R170, R123/R170, R134a/R170, R404A/R170, R407c/R170, R410/R170, and the hydrocarbon (HC) refrigerant pair Propane/Ethane, namely R290/R170. Besides, the results of R22/R170 pair, which is not recommended to be used due to phase out of R22 as per Montréal Protocol, are included as base case to compare the novel hydrocarbon pairs in CRS and the old trend of refrigerant pairs. Thermodynamic properties of all these pairs were investigated and compared under different intermediate temperature used in CRS heat exchanger, which thermally connected both the Low and High temperature cycles (LTC) and (HTC). By applying the first law of thermodynamics, the coefficients of performance (COPs) and the specific power consumptions (SPC) in kW/TR are presented and compared. In addition, by applying the second law of thermodynamics the exergetic efficiencies were estimated. The results reveal the promising opportunity of using the HC pair (R290/R170). The minimum SPC in kW/TR is recorded for the pair R123/R170. One the other hand, the highest exegetic efficiency values are observed to be 40%, 38%, and 35% for the pairs R123/R170, R290/R170, and R134/R170, respectively. This research concludes that the HC pair (R290/R170) is highly recommended for CRS applications either to transport the COVID-19 or store it in cold storage rooms in hospitals and clinics. All precautionary measures should be carefully applied in design and operation of HC pair (R290/R170) due to its flammability hazard.