On-Cam Operation of Counter-Rotating Type Hydroelectric Unit 被引量:1
1
作者 Toshiaki Suzuki Toshiaki Kanemoto 《Journal of Energy and Power Engineering》 2013年第10期1966-1973,共8页
The counter-rotating type hydroelectric unit, which is composed of the axial flow type tandem runners and the peculiar generator with double rotational armatures, has been proposed. In the unit, the front and the rear... The counter-rotating type hydroelectric unit, which is composed of the axial flow type tandem runners and the peculiar generator with double rotational armatures, has been proposed. In the unit, the front and the rear runners counter-drive the inner and the outer armatures of the generator, respectively. Besides, the flow direction at the rear runner outlet must coincide with the direction at the front runner inlet, because the angular momentum change through the rear runner must coincides with that through the front runner. In this paper, the tandem runners work at on-cam conditions in keeping the induced frequency constant, to provide the hydroelectric unit for the power grid system. The output and the hydraulic efficiency are affected by the adjusting angles of the front and the rear blades. Both optimum angles giving the maximum output or efficiency were presented at the various discharge/head circumstances, accompanying with the turbine performances. 展开更多
关键词 hydroelectric unit counter rotation tandem runners double rotational armatures on-cam.
下载PDF
FAULT CAUSED BY WATER PRESSURE IN THE HEAD-COVER CHAMBER
2
作者 PEI Hai-lin QI Xue-yi +2 位作者 LI Hui LI Jian-hui PEI Ze-yu 《Journal of Hydrodynamics》 SCIE EI CSCD 2006年第3期280-286,共7页
Owing to the high temperature of the thrust beating pads, the No.l unit wasn't performed in the upgrading test at Liujiaxia Hydropower Plant. Through the experimental and theoretical analysis, it has been confirmed t... Owing to the high temperature of the thrust beating pads, the No.l unit wasn't performed in the upgrading test at Liujiaxia Hydropower Plant. Through the experimental and theoretical analysis, it has been confirmed that the fault unit was caused by the high water pressure in the head-cover chamber. This type of the fault is out-of-the-way. After the suitable measure wags against the fault were taken, the No. 1 unit can stably operate. The conclusions and the methodology are of the certain reference value to the fault-diagnosis of the hydroelectric unit. 展开更多
关键词 hydroelectric unit PERTURBATION vibration fault diagnosis
原文传递