期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
A novel oil spill detection method from synthetic aperture radar imageries via a bidimensional empirical mode decomposition 被引量:2
1
作者 YANG Yonghu LI Ying ZHU Xueyuan 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第7期86-94,共9页
Oil spills pose a major threat to ocean ecosystems and their health. Synthetic aperture radar(SAR) sensors can detect oil spills on the sea surface. These oil spills appear as dark spots in SAR images. However, dark... Oil spills pose a major threat to ocean ecosystems and their health. Synthetic aperture radar(SAR) sensors can detect oil spills on the sea surface. These oil spills appear as dark spots in SAR images. However, dark formations can be caused by a number of phenomena. It is aimed to distinguishing oil spills or look-alike objects. A novel method based on a bidimensional empirical mode decomposition is proposed. The selected dark formations are first decomposed into several bidimensional intrinsic mode functions and the residue. Subsequently, 64 dimension feature sets are calculated using the Hilbert spectral analysis and five new features are extracted with a relief algorithm. Mahalanobis distances are then used for classification. Three data sets containing oil spills or look-alikes are used to test the accuracy rate of the method. The accuracy rate is more than 90%. The experimental results demonstrate that the novel method can detect oil spills validly and accurately. 展开更多
关键词 bidimensional empirical mode decomposition synthetic aperture radar image detection of oil spill hilbert spectral analysis
下载PDF
Eurovet Unveils the New Image of Hong Kong Mode Lingerie 2010 March 30-31, at the Hong Kong Convention and Exhibition Centre
2
《China Textile》 2010年第2期20-21,共2页
Organized by Eurovet, the world’s leading lingerie and beachwear trade show organizer and supported by Hong
关键词 2010 Eurovet Unveils the New image of Hong Kong mode Lingerie 2010 March 30-31 at the Hong Kong Convention and Exhibition Centre
下载PDF
Investigation and Application of High Megavoltage X-Ray Imaging Mode in Radiotherapy
3
作者 Quanshi Zhang Xiwen Wang +5 位作者 Qiyin Sun Yuehui Jin Yun Li Ziyu Li Tao Sun Liang Wang 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第1期42-50,共9页
After drawbacks and shortages of using conventional kV or MV imaging mode were analyzed, this study proposes a new position verification mode with using the energy larger than 15 MeV or nominal accelerating potential ... After drawbacks and shortages of using conventional kV or MV imaging mode were analyzed, this study proposes a new position verification mode with using the energy larger than 15 MeV or nominal accelerating potential greater than 25 MV X-Ray. The new position verification mode is named HMV imaging mode. Along with the comparison of theoretical analyses, phantom experiments and clinical results to the original imaging modes, this report is going to demonstrate the HMV imaging mode is superior to traditional kV and MV imaging modes. This report first theoretically analyzed three main effects of X-ray interacting with medium by numerous equations and compared their mass attenuation coefficient with different types of tissue. X-ray irradiated on a “Catphan 500” cylinder phantom with different energies to verify these theoretical results. Furthermore, based on phantom experiments’ results, we have done numerous clinical trials and comparisons with patient’s clinical results. The theoretical and experimental results illustrate that the scanned images from HMV mode have a good quality and have ability to identify different tissue components clearly. HMV imaging mode overcomes drawbacks of position verification from both kV and MV level imaging mode as well as keeping advantages of kV and MV imaging mode. The result indicates that HMV is a good position verification mode in radiotherapy. 展开更多
关键词 High Energy X-Ray X-Ray Imaging mode Position Verification Reaction Cross-Section
下载PDF
Colonic mucosa-associated lymphoid tissue lymphoma identified by chromoendoscopy 被引量:2
4
作者 Sang-Wook Seo Seung-Hwa Lee +4 位作者 Duck-Joo Lee Kwang-Min Kim Joon-Koo Kang Do-Wan Kim Jeong-Hun Lee 《World Journal of Gastroenterology》 SCIE CAS 2014年第48期18487-18494,共8页
Colonic mucosa-associated lymphoid tissue (MALT) lymphomas are a rare occurrence and the definitive treatment has not been established. Solitary or multiple, elevated or polypoid lesions are the usual appearances of M... Colonic mucosa-associated lymphoid tissue (MALT) lymphomas are a rare occurrence and the definitive treatment has not been established. Solitary or multiple, elevated or polypoid lesions are the usual appearances of MALT lymphoma in the large intestine and sometimes the surface may reveal abnormal vascularity. Herein, we report a case of MALT lymphoma and review the relevant literature. Upon colonoscopy, a suspected pathologic lesion was observed in the proximal transverse colon. The lesion could be distinguished more prominently after using narrow-band imaging mode and indigo carmine-dye spraying chromoendoscopy. Histopathologic examination of this biopsy specimen revealed lymphoepithelial lesions with diffuse proliferation of atypical lymphoid cells effacing the glandular architecture and centrocyte-like cells infiltrating the lamina propria. Immunohistochemical analyses showed that tumor cells were positive for CD20 and Bcl-2e, and negative for CD10, CD23, and Bcl-6. According to Ann-Arbor staging system, the patient had stage II<sub>E</sub>. A partial colectomy with dissection of the paracolic lymph nodes was performed. Until now, there is no recurrence of lymphoma at follow-up. 展开更多
关键词 CHROMOENDOSCOPY LYMPHOMA Mucosa-associated lymphoid tissue Narrow-band imaging mode
下载PDF
Measurement, modelling, and closed-loop control of crystal shape distribution: Literature review and future perspectives 被引量:1
5
作者 Cai Y. Ma Jing J. Liu Xue Z. Wang 《Particuology》 SCIE EI CAS CSCD 2016年第3期1-18,共18页
Crystal morphology is known to be of great importance to the end-use properties of crystal products, and to affect down-stream processing such as filtration and drying. However, it has been previously regarded as too ... Crystal morphology is known to be of great importance to the end-use properties of crystal products, and to affect down-stream processing such as filtration and drying. However, it has been previously regarded as too challenging to achieve automatic closed-loop control. Previous work has focused on controlling the crystal size distribution, where the size of a crystal is often defined as the diameter of a sphere that has the same volume as the crystal. This paper reviews the new advances in morphological population balance models for modelling and simulating the crystal shape distribution (CShD), measuring and estimating crystal facet growth kinetics, and two- and three-dimensional imaging for on-line characterisation of the crystal morphology and CShD. A framework is presented that integrates the various components to achieve the ultimate objective of model-based closed-loop control of the CShD. The knowledge gaps and challenges that require further research are also identified. 展开更多
关键词 Crystal morphology Crystal shape distribution Morphological population balance mode3D process imaging Closed-loop control of crystal shapeCrystal facet growth kinetics
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部