A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are...A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are introduced in detail. The photon counting imaging detector comprises a micro-channel plate (MCP) stack, and a wedge and strip anode (WSA). The resolution mask pattern in front of the MCP can be reconstructed after data processing in the FPGA. For high count rates, the rejection design can effectively reduce the impact of the pulse pile-up on the image. The resolution can reach up to 140μm. The pulse pile-up rejection design can also be applied to high-energy physics and particle detection.展开更多
The focal hepatic lesion caused by local injection of absolute alcohol in rats was evaluated with ultrasonic contrast agent and pathologic examination. Twenty adult Wistar rats weighing about 200 g were injected with ...The focal hepatic lesion caused by local injection of absolute alcohol in rats was evaluated with ultrasonic contrast agent and pathologic examination. Twenty adult Wistar rats weighing about 200 g were injected with absolute alcohol (0. 05-0. 1 mL each one) on the exterior left lobe of the liver under the monitoring of ultrasound. Pulse inversion harmonic imaging was used to evaluate the focal lesion after bolus injection of ultrasonic contrast agent (0. 05 mL/200 g) through caudal vein. Seven days later, the focal lesion was studied again as before. The exterior left lobe of liver with focal lesion was incised and underwent pathologic examination. The results showed that all of the focal lesions could be defined clearly after bolus injection of the ultrasonic contrast agent under the mode of pulse inversion harmonic imaging. There was good correlation between the size of the focal lesion measured by ultrasound on the 7th day after the "ablation" under the mode of pulse inversion harmonic imaging and that gotten by pathologic examination (P=0.39). The focus size measured by ultrasound right after the ablation was larger than that gotten by pathologic examination (P=0. 002). It was concluded that ultrasonic contrast agent plus pulse inversion harmonic imaging could be used to assess the size of the focal hepatic lesion caused by local injection of absolute alcohol in rats.展开更多
Aiming at the problem of resource allocation for digital array radar( DAR),a dwell scheduling algorithm is proposed in this paper. Firstly,the integrated priority of different radar tasks is designed,which ensures t...Aiming at the problem of resource allocation for digital array radar( DAR),a dwell scheduling algorithm is proposed in this paper. Firstly,the integrated priority of different radar tasks is designed,which ensures that the imaging tasks are scheduled without affecting the search and tracking tasks; Then,the optimal scheduling model of radar resource is established according to the constraints of pulse interleaving; Finally,a heuristic algorithm is used to solve the problem and a sparse-aperture cognitive ISAR imaging method is used to achieve partial precision tracking target imaging. Simulation results demonstrate that the proposed algorithm can both improve the performance of the radar system,and generate satisfactory imaging results.展开更多
基金Supported by the National Natural Science Foundation of China under Grant No 11375179
文摘A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are introduced in detail. The photon counting imaging detector comprises a micro-channel plate (MCP) stack, and a wedge and strip anode (WSA). The resolution mask pattern in front of the MCP can be reconstructed after data processing in the FPGA. For high count rates, the rejection design can effectively reduce the impact of the pulse pile-up on the image. The resolution can reach up to 140μm. The pulse pile-up rejection design can also be applied to high-energy physics and particle detection.
文摘The focal hepatic lesion caused by local injection of absolute alcohol in rats was evaluated with ultrasonic contrast agent and pathologic examination. Twenty adult Wistar rats weighing about 200 g were injected with absolute alcohol (0. 05-0. 1 mL each one) on the exterior left lobe of the liver under the monitoring of ultrasound. Pulse inversion harmonic imaging was used to evaluate the focal lesion after bolus injection of ultrasonic contrast agent (0. 05 mL/200 g) through caudal vein. Seven days later, the focal lesion was studied again as before. The exterior left lobe of liver with focal lesion was incised and underwent pathologic examination. The results showed that all of the focal lesions could be defined clearly after bolus injection of the ultrasonic contrast agent under the mode of pulse inversion harmonic imaging. There was good correlation between the size of the focal lesion measured by ultrasound on the 7th day after the "ablation" under the mode of pulse inversion harmonic imaging and that gotten by pathologic examination (P=0.39). The focus size measured by ultrasound right after the ablation was larger than that gotten by pathologic examination (P=0. 002). It was concluded that ultrasonic contrast agent plus pulse inversion harmonic imaging could be used to assess the size of the focal hepatic lesion caused by local injection of absolute alcohol in rats.
基金Supported by the National Natural Science Foundation of China(61471386)
文摘Aiming at the problem of resource allocation for digital array radar( DAR),a dwell scheduling algorithm is proposed in this paper. Firstly,the integrated priority of different radar tasks is designed,which ensures that the imaging tasks are scheduled without affecting the search and tracking tasks; Then,the optimal scheduling model of radar resource is established according to the constraints of pulse interleaving; Finally,a heuristic algorithm is used to solve the problem and a sparse-aperture cognitive ISAR imaging method is used to achieve partial precision tracking target imaging. Simulation results demonstrate that the proposed algorithm can both improve the performance of the radar system,and generate satisfactory imaging results.